[sample_stage] enabled = Always implementation = normal_sample_stage name = sample_stage optype = motion_axis [12tmagnet_oxford] desc = "12 Tesla Oxford Magnet" driver = "oxford_labview" imptype = magnetic_field ip = 10.157.205.3 port = 55001 [bruker_bec1] desc = "Bruker Magnet" driver = "bruker_bec1" type = B imptype = magnetic_field ip = XXXX port = XXXX [rhqc_setup] cascade = sample_stage:normal_sample_stage,T1:ls340_01,T2:ls340_02 enabled = False [bruker_setup] cascade = B1:bruker_bec1,sample_stage:normal_sample_stage,T1:julabo_lh45 enabled = False [12Tmagnet_setup] cascade = B1:12tmagnet_oxford,sample_stage:Oxford_12tmagnet_sample_insert,T1:mercury_scpi_01 enabled = False [10_position_setup] cascade = T1:watlow_rm,sample_stage:10_pos_sample_stage enabled = False [20_position_setup] cascade = T1:julabo_lh45,sample_stage:20_pos_sample_stage enabled = False [B1] enabled = False id = 1 implementation = none name = magnet1 optype = magnetic_field [CF1] cascade = T1:CF1_ls340,sample_stage:normal_sample_stage enabled = False [CF1_ls340] desc = "cf1: Bottom loading cryofurnace" driver = "lakeshore_340" imptype = temperature ip = 10.157.205.43 port = 4001 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [Default] cascade = sample_stage:normal_sample_stage enabled = True [I1] datype = I enabled = False id = 1 implementation = none name = curr1 optype = multimeter [I2] datype = I enabled = False id = 2 implementation = none name = curr2 optype = multimeter [Oxford_12tmagnet_sample_insert] desc = "som will be redefined as the magnet sample insert rotation. Sample stage will be renamed to somss" imptype = motion_axis [T1] enabled = False id = 1 implementation = none name = tc1 optype = temperature [T2] enabled = False id = 2 implementation = none name = tc2 optype = temperature [T3] enabled = False id = 3 implementation = none name = tc3 optype = temperature [T4] enabled = False id = 4 implementation = none name = tc4 optype = temperature [T5] enabled = False id = 5 implementation = none name = tc5 optype = temperature [V1] datype = V enabled = False id = 1 implementation = none name = volts1 optype = multimeter [V2] datype = V enabled = False id = 2 implementation = none name = volts2 optype = multimeter [ls336_01] desc = "tc1: Lakeshore 336 temperature controller" driver = "lakeshore_336" imptype = temperature ip = 10.157.205.28 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_02] desc = "tc2: Lakeshore 336 temperature controller" driver = "lakeshore_336" imptype = temperature ip = 10.157.205.29 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_04] desc = "tc3: Lakeshore 336 temperature controller" driver = "lakeshore_336" imptype = temperature ip = 10.157.205.30 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_05] desc = "tc4: Lakeshore 336 temperature controller" driver = "lakeshore_336" imptype = temperature ip = 137.157.201.21 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_06] desc = "tc5: Lakeshore 336 temperature controller" driver = "lakeshore_336" imptype = temperature ip = 137.157.201.21 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_12] desc = "tc6: Lakeshore 336 temperature controller" driver = "lakeshore_336" imptype = temperature ip = 10.157.205.31 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls340_01] desc = "tc7: Lakeshore 340 temperature controller" driver = "lakeshore_340" id = 2 imptype = temperature ip = 137.157.201.86 port = 4001 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls340_02] desc = "tc8: Lakeshore 340 temperature controller" driver = "lakeshore_340" imptype = temperature ip = 137.157.201.86 port = 4002 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [mercury_scpi_01] desc = "Oxford Mercury temperature controller in Mercury mode" driver = "mercury_scpi" imptype = temperature ip = 10.157.205.5 permlink = LT port = 7020 terminator = \r\n tol = 1.0 valve_tol = 2 [mercury_scpi_02] desc = "Oxford Mercury temperature controller in Mercury mode" driver = "mercury_scpi" imptype = temperature ip = 10.157.205.47 permlink = LT port = 7020 terminator = \r\n tol = 1.0 valve_tol = 2 [normal_sample_stage] desc = "This is the default sample stage configuration xyz translation omega rotation but no tilt axes" imptype = motion_axis [10_pos_sample_stage] desc = "Load the ten position sample changer configuration" imptype = motion_axis [20_pos_sample_stage] desc = "Load the twenty position sample changer configuration" imptype = motion_axis [protek_01] desc = "Protek Multimeter" driver = "protek" imptype = multimeter ip = 10.157.205.36 port = 4001 [protek_02] desc = "Protek Multimeter" driver = "protek" imptype = multimeter ip = 10.157.205.37 port = 4001 [sample_stage] enabled = Always implementation = normal_sample_stage name = sample_stage optype = motion_axis [west4100] desc = "Blue furnace temperature controller" driver = "west4100" imptype = temperature ip = 10.157.205.19 [julabo_lh45] desc = "Julabo temperature controller" driver = "julabo_lh45" imptype = temperature ip = ca4-quokka port = 4003 terminator = \r\n tol = 0.5 [watlow_rm] desc = "Watlow RM temperature controller" driver = "watlow_rm" imptype = temperature ip = 10.157.205.6 terminator = \r\n tol = 0.5 type = T