set sim_mode [SplitReply [hmm_simulation]] if {$sim_mode == "true"} { MakeHM hmm SIM; namespace eval histogram_memory { proc hmc {_start _preset _mode _pause} { bm mode $_mode; bm preset $_preset; hmm countblock; } } } else { MakeHM hmm anstohttp; MakeHMControl_ANSTO hmc bm hmm; } source $cfPath(hmm)/hmm_configuration_common_1.tcl if {$sim_mode == "true"} { proc ::histogram_memory::hmm_initialize {} { hmm configure hmaddress http://das1-[SplitReply [instrument]]:8080; hmm configure username spy; hmm configure password 007; hmm configure hmDataPath ../HMData; } } # Configure to upload a complete configuration to the histogram server. # In this case it's the main config file plus the FAT, BAT and OAT files # in the same direcory as the SICS executable (for this example). # Alternatives: # - A partial config could be uploaded instead - e.g. just the main config file, # in that case the main config file points to a set of FAT, BAT OAT files # located on the server. # - The histogram server could configure itself from a config file set # kept on the local file system (not automated presently, manual control only) # - Or, no configuration at all could be uploaded, the # histogram server can configure itself using its default config files. proc ::histogram_memory::setmode {mode} { hmm_mode $mode; set sim_mode [SplitReply [hmm_simulation]]; switch $mode { pulser { if {$sim_mode == "true"} { hmm configure oat_nyc_eff 1024; hmm configure oat_nxc_eff 64; hmm configure oat_ntc_eff 1; } _hmm_hor_channel_name tube_pair_number _hmm_hor_axis tube_pair_number _hmm_hor_axis_alias dcolindex _hmm_vert_axis vertical_channel_number _hmm_vert_axis_alias drowindex hmm configure hmconfigscript "returnconfigfile [SplitReply [hmm_user_configpath]]/anstohm_full_MESYTEC_PULSER.xml" } calibration { if {$sim_mode == "true"} { hmm configure oat_nyc_eff 1024; hmm configure oat_nxc_eff 64; hmm configure oat_ntc_eff 1; } _hmm_hor_channel_name tube_pair_number _hmm_hor_axis tube_pair_number _hmm_hor_axis_alias dcolindex _hmm_vert_axis vertical_channel_number _hmm_vert_axis_alias drowindex hmm configure hmconfigscript "returnconfigfile [SplitReply [hmm_user_configpath]]/anstohm_full_nofolding.xml" } normal - default { if {$sim_mode == "true"} { hmm configure oat_nyc_eff 512; hmm configure oat_nxc_eff 128; hmm configure oat_ntc_eff 1; } _hmm_hor_channel_name horizontal_channel_number _hmm_hor_axis polar_angle _hmm_hor_axis_alias dtheta _hmm_vert_axis vertical_channel_number _hmm_vert_axis_alias drowindex OAT_TABLE X {-210.5 -209.5} Y {-110.5 -109.5} T {0 20000} NTC 5 ::histogram_memory::configure_server Filler_defaults FASTCOMTEC } } }