[12tmagnet_setup] cascade = B1:12tmagnet_oxford,sample_stage:12tmagnet_sample_insert,T1:mercury_scpi_01 enabled = False [CF3] cascade = T1:ls340_pelican,sample_stage:normal_sample_stage enabled = False [CF8] cascade = T1:ls336_01,T2:ls340_11,sample_stage:normal_sample_stage enabled = False [Default] cascade = sample_stage:normal_sample_stage,T1:ls340_pelican enabled = True [OC1] cascade = T1:OC1_ls340,sample_stage:normal_sample_stage enabled = False [B1] datype = B enabled = False id = 1 implementation = none name = magnet1 optype = magnetic_field [Function_Generator] datype = V enabled = False id = 1 implementation = none name = pulser optype = function_generator [I1] datype = I enabled = False id = 1 implementation = none name = curr1 optype = multimeter [I2] datype = I enabled = False id = 2 implementation = none name = curr2 optype = multimeter [T1] datype = T enabled = True id = 1 implementation = ls340_pelican name = tc1 optype = temperature [T2] datype = T enabled = False id = 2 implementation = none name = tc2 optype = temperature [T3] datype = T enabled = False id = 3 implementation = none name = tc3 optype = temperature [T4] datype = T enabled = False id = 4 implementation = none name = tc4 optype = temperature [V1] datype = V enabled = False id = 1 implementation = none name = volts1 optype = multimeter [V2] datype = V enabled = False id = 2 implementation = none name = volts2 optype = multimeter [ls218] enabled = Always implementation = ls218-01 name = ls218 optype = lakeshore_218 [sample_stage] enabled = Always implementation = normal_sample_stage name = sample_stage optype = motion_axis [12tmagnet_oxford] asyncqueue = sct desc = "12 Tesla Oxford Magnet" driver = "oxford12tlv" imptype = magnetic_field interval = 5 ip = 10.157.205.3 port = 55001 [12tmagnet_sample_insert] desc = "scor will be redefined as the magnet sample insert rotation." imptype = motion_axis [OC1_ls340] asyncqueue = sct desc = "Lakeshore 340 temperature controller" driver = "ls340" imptype = temperature ip = 10.157.205.41 port = 4001 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [agilent_33220A] asyncqueue = sct desc = "Function Generator" driver = agilent_33220A imptype = function_generator ip = 10.157.205.16 port = 5025 [ls218-01] desc = "Lakeshore 218 Temperature Monitor" driver = "lakeshore_218" imptype = lakeshore_218 ip = ca2-pelican port = 4002 [ls336_01] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.28 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_02] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.29 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_04] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.30 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_05] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 137.157.201.21 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_06] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 137.157.201.21 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_11] desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.27 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_12] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.31 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls340_01] asyncqueue = sct desc = "Lakeshore 340 temperature controller" driver = "ls340" imptype = temperature ip = 137.157.201.86 port = 4001 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls340_02] asyncqueue = sct desc = "Lakeshore 340 temperature controller" driver = "ls340" imptype = temperature ip = 137.157.201.86 port = 4002 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls340_11] desc = "Lakeshore 340 temperature controller" driver = "ls340" imptype = temperature ip = 137.157.201.86 port = 4001 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls340_pelican] desc = "Lakeshore 340 temperature controller" driver = "ls340" imptype = temperature ip = 137.157.202.214 port = 4001 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [mercury_scpi_01] desc = "Oxford Mercury temperature controller with three temperature loops." driver = "mercury_base" imptype = temperature ip = 10.157.205.5 permlink = LT port = 7020 terminator = \r\n tol = 1.0 valve_tol = 2 [mercury_scpi_02] desc = "Oxford Mercury temperature controller with four temperature loops and needle valve control" driver = "mercury_scpi" imptype = temperature ip = 10.157.205.47 permlink = LT port = 7020 terminator = \r\n tol = 1.0 valve_tol = 2 [normal_sample_stage] desc = "This is the default sample stage configuration" imptype = motion_axis [protek_01] asyncqueue = sct desc = "Protek Multimeter" driver = "protekmm" imptype = multimeter ip = 10.157.205.36 port = 4001 [protek_02] asyncqueue = sct desc = "Protek Multimeter" driver = "protekmm" imptype = multimeter ip = 10.157.205.37 port = 4001 [west4100] desc = "Blue furnace temperature controller" dev_id = 1 driver = "west4100" imptype = temperature ip = 10.157.205.19