[10_position_setup] cascade = T1:watlow_rm,sample_stage:10_pos_sample_stage enabled = False [12Tmagnet_setup] cascade = B1:12tmagnet_oxford,sample_stage:Oxford_12tmagnet_sample_insert,T1:mercury_01 enabled = False [20_position_pulser] cascade = T1:julabo_lh45,Function_Generator:agilent_33220A,High_Voltage:protek_02,sample_stage:20_pos_sample_stage enabled = False [20_position_setup] cascade = T1:julabo_lh45,sample_stage:20_pos_sample_stage enabled = False [CF1] cascade = T1:CF1_ls340,sample_stage:normal_sample_stage enabled = False [Default] cascade = sample_stage:normal_sample_stage enabled = True [Differential_Scanning_Calorimetry] cascade = DSC:protek_01,sample_stage:normal_sample_stage enabled = False [HV_control] cascade = Function_Generator:agilent_33220A,High_Voltage:protek_01,sample_stage:normal_sample_stage enabled = False [Rheometer_APMCR500_setup] cascade = rhSpeed:protek_01,rhTorque:protek_02,Rheometry:antonparr_MCR500 enabled = False [bruker_setup] cascade = B1:bruker_bec1,sample_stage:normal_sample_stage,T1:julabo_lh45 enabled = False [rhqc_setup] cascade = sample_stage:normal_sample_stage,T1:ls340_01,T2:ls340_02 enabled = False [B1] datype = B enabled = False id = 1 implementation = none name = magnet1 optype = magnetic_field [DSC] datype = V enabled = False id = 1 implementation = none name = dsc_val optype = multimeter [Flow Control] datype = FC enabled = False id = 1 implementation = none name = fc1 optype = flowcontrol [Function_Generator] datype = V enabled = False id = 1 implementation = none name = pulser optype = function_generator [High_Voltage] datype = V enabled = False id = 1 implementation = none name = hv_val optype = multimeter [I1] datype = I enabled = False id = 1 implementation = none name = curr1 optype = multimeter [I2] datype = I enabled = False id = 2 implementation = none name = curr2 optype = multimeter [Power Supply] datype = V enabled = False id = 1 implementation = none name = isops optype = power_supply [Rheometry] enabled = False implementation = none optype = rheometry [T1] datype = T enabled = False id = 1 implementation = none name = tc1 optype = temperature [T2] datype = T enabled = False id = 2 implementation = none name = tc2 optype = temperature [T3] datype = T enabled = False id = 3 implementation = none name = tc3 optype = temperature [T4] datype = T enabled = False id = 4 implementation = none name = tc4 optype = temperature [T5] datype = T enabled = False id = 5 implementation = none name = tc5 optype = temperature [T6] datype = T enabled = False id = 6 implementation = none name = tc6 optype = temperature [V1] datype = V enabled = False id = 1 implementation = none name = volts1 optype = multimeter [V2] datype = V enabled = False id = 2 implementation = none name = volts2 optype = multimeter [Viscosity] enabled = False id = 1 implementation = none name = visc optype = viscosity [rhSpeed] enabled = False implementation = none name = rhSpeed optype = rheometry [rhTorque] enabled = False implementation = none name = rhTorque optype = rheometry [sample_stage] enabled = Always implementation = normal_sample_stage name = sample_stage optype = motion_axis [10_pos_sample_stage] desc = "Load the ten position sample changer configuration" imptype = motion_axis [11tmagnet_oxford] desc = "11/10 Tesla Oxford Magnet" driver = "oxford_labview" imptype = magnetic_field interval = 5 ip = 10.157.205.44 port = 55001 [12tmagnet_oxford] desc = "12 Tesla Oxford Magnet" driver = "oxford_labview" imptype = magnetic_field interval = 5 ip = 10.157.205.3 port = 55001 [20_pos_sample_stage] desc = "Load the twenty position sample changer configuration" imptype = motion_axis [5Tmagnet] desc = "The New Zealand magnet" driver = tsi_smc imptype = magnetic_field ip = 137.157.202.79 port = 4004 timeout = 2000 [CF1_ls340] desc = "cf1: Bottom loading cryofurnace" driver = "ls340" imptype = temperature ip = 10.157.205.43 port = 4001 terminator = \r\n tol1 = 0.2 tol2 = 0.2 [Oxford_12tmagnet_sample_insert] desc = "som will be redefined as the magnet sample insert rotation. Sample stage will be renamed to somss" imptype = motion_axis [agilent_33220A] asyncqueue = sct desc = "Function Generator" driver = agilent_33220A imptype = function_generator ip = 10.157.205.16 port = 5025 [antonparr_MCR500] cbfunc = "rhCallback /sics/$rhControl" desc = "Anton Parr MRC500 Rheometer" driver = "antonparr_MCR500" imptype = rheometry ip = noip port = noport settle = 5.0 speed_name = rhSpeed tol = 0.01 torque_name = rhTorque [bruker_bec1] desc = "Bruker Magnet" driver = "bruker_bec1" imptype = magnetic_field ip = 10.157.205.13 port = 4444 type = B [hiden_xcs] desc = "Hiden XCS Relative Humidity Flow Control" driver = "hiden_xcs" imptype = flowcontrol ip = 137.157.202.79 port = 4001 [isotech_ps] desc = "Isotech Power Supply:Baud=2400,Data=8,Stop=1,Parity=None,Flow=None" driver = "isotech_ps" imptype = power_supply ip = 137.157.202.79 port = 4001 [julabo_lh45] ctrl_sensor = "bath" desc = "Julabo temperature controller" driver = "julabo_lh45" imptype = temperature ip = 10.157.205.39 port = 4001 tol = 5.0 type = T [ls336_01] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.28 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_02] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.29 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_04] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.30 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_05] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 137.157.201.21 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_06] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.61 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_12] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.31 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls340_01] asyncqueue = sct desc = "Lakeshore 340 temperature controller" driver = "ls340" imptype = temperature ip = 137.157.201.86 port = 4001 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls340_02] asyncqueue = sct desc = "Lakeshore 340 temperature controller" driver = "ls340" imptype = temperature ip = 137.157.201.86 port = 4002 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls340_09] desc = "Lakeshore 340 temperature controller" driver = "ls340" imptype = temperature ip = 137.157.202.79 port = 4002 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls340_11] desc = "Lakeshore 340 temperature controller" driver = "ls340" imptype = temperature ip = 137.157.201.86 port = 4001 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [mercury_01] assoc = 00000124 cards = HHHVLTTP desc = "Oxford Mercury temperature controller (12T)" driver = "oxford_mercury" imptype = temperature ip = 10.157.205.5 port = 7020 ptol = 5 terminator = \n timeout = 2000 ttol = 1.0 vtol = 5 [mercury_02] assoc = 00000124 cards = HHTVTTTP desc = "Oxford Mercury temperature controller (CF10)" driver = "oxford_mercury" imptype = temperature ip = 10.157.205.46 port = 7020 ptol = 5 terminator = \n timeout = 2000 ttol = 1.0 vtol = 5 [mercury_03] assoc = 00000123 cards = HHHNNTTT desc = "Oxford Mercury temperature controller ()" driver = "oxford_mercury" imptype = temperature ip = 10.157.205.47 port = 7020 ptol = 5 terminator = \n timeout = 2000 ttol = 1.0 vtol = 5 [newport_rva] desc = "Newport Rapid Visco-Analyser" driver = "nprvasm2" imptype = viscosity ip = 137.157.202.91 port = 4001 tol = 1 [normal_sample_stage] desc = "This is the default sample stage configuration xyz translation omega rotation but no tilt axes" imptype = motion_axis [protek_01] asyncqueue = sct desc = "Protek Multimeter" driver = "protekmm" imptype = multimeter ip = 10.157.205.36 port = 4001 [protek_02] asyncqueue = sct desc = "Protek Multimeter" driver = "protekmm" imptype = multimeter ip = 10.157.205.37 port = 4001 [watlow_rm] desc = "Watlow RM temperature controller" driver = "watlow_mrm" imptype = temperature ip = 10.157.205.6 terminator = \r\n tol = 0.5 type = T [vf1_west6100] asyncprotocol = modbus_ap desc = "VF1 Blue furnace temperature controller" dev_id = 1 driver = "west_6100" imptype = temperature ip = 10.157.205.24 port = 502 [vf2_west6100] asyncprotocol = modbus_ap desc = "VF2 Blue furnace temperature controller" dev_id = 1 driver = "west_6100" imptype = temperature ip = 10.157.205.25 port = 502