[12tmagnet_setup] cascade = B1:12tmagnet_oxford,sample_stage:12tmagnet_sample_insert,m2s2:normal_m2s2,T1:mercury_01 enabled = False [3He_setup] cascade = HE3:he3_both,sample_stage:normal_sample_stage,m2s2:extended_m2s2 enabled = False [CF1] cascade = T1:CF1_ls340,sample_stage:normal_sample_stage,m2s2:normal_m2s2 enabled = False [CF4] cascade = T1:CF4_ls340,sample_stage:normal_sample_stage,m2s2:normal_m2s2 enabled = False [CF7] cascade = T1:ls336_08,T2:ls336_05,sample_stage:normal_sample_stage enabled = False [Default] cascade = sample_stage:normal_sample_stage,m2s2:normal_m2s2 enabled = True [OC1] cascade = T1:OC1_ls340,sample_stage:normal_sample_stage,m2s2:normal_m2s2 enabled = False [B1] datype = B enabled = False id = 1 implementation = none name = magnet1 optype = magnetic_field [Function_Generator] datype = V enabled = False id = 1 implementation = none name = pulser optype = function_generator [HE3] datype = X enabled = False id = 1 implementation = none name = he3 optype = polariser [I1] datype = I enabled = False id = 1 implementation = none name = curr1 optype = multimeter [I2] datype = I enabled = False id = 2 implementation = none name = curr2 optype = multimeter [P1] datype = P enabled = False id = 1 implementation = none name = pressure1 optype = pressure [T1] datype = T enabled = False id = 1 implementation = none name = tc1 optype = temperature [T2] datype = T enabled = False id = 2 implementation = none name = tc2 optype = temperature [T3] datype = T enabled = False id = 3 implementation = none name = tc3 optype = temperature [T4] datype = T enabled = False id = 4 implementation = none name = tc4 optype = temperature [V1] datype = V enabled = False id = 1 implementation = none name = volts1 optype = multimeter [V2] datype = V enabled = False id = 2 implementation = none name = volts2 optype = multimeter [m2s2] enabled = Always implementation = normal_m2s2 name = m2s2 optype = m2s2_axes [sample_stage] enabled = Always implementation = normal_sample_stage name = sample_stage optype = motion_axis [12tmagnet_oxford] asyncqueue = sct desc = "12 Tesla Oxford Magnet" driver = "oxford12tlv" imptype = magnetic_field interval = 5 ip = 10.157.205.3 port = 55001 [12tmagnet_sample_insert] desc = "s1 will be redefined as the magnet sample insert rotation." imptype = motion_axis [CF1_ls340] desc = "cf1: Bottom loading cryofurnace" driver = "ls340" imptype = temperature ip = 10.157.205.43 port = 4001 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [CF4_ls340] desc = "cf4: cryofurnace" driver = "ls340" imptype = temperature ip = 137.157.203.137 port = 4001 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [OC1_ls340] desc = "cf1: Orange Cryostat" driver = "ls340" imptype = temperature ip = 10.157.205.41 port = 4001 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [agilent_33220A] asyncqueue = sct desc = "Function Generator" driver = agilent_33220A imptype = function_generator ip = 10.157.205.16 name = pulser port = 5025 [anv_west6100] asyncprotocol = modbus_ap desc = "Needle valve West 6100 temperature controller" dev_id = 1 driver = "west_6100" imptype = pressure ip = 10.157.205.56 port = 502 timeout = 2000 [e3200_01] asyncprotocol = modbus_ap datype = T desc = "Eurotherm 3200 (modbus/sct)" dev_id = 21 driver = "eurotherm_3200" imptype = temperature ip = 10.157.205.58 port = 502 tol = 5 [eulerian_cradle] desc = "Load the Eulerian cradle configuration" imptype = motion_axis [extended_m2s2] desc = "This sets lower speeds and accelerations when the m2 and s2 axes are extended" imptype = m2s2_axes [he3_analyser] desc = "3He Analyser" driver = "he3_polanal" has_anal = true has_pol = false imptype = polariser ip = 10.157.205.2 port = 55013 terminator = \r\n [he3_both] desc = "3He Pol+Anal" driver = "he3_polanal" has_anal = true has_pol = true imptype = polariser ip = 10.157.205.2 port = 55013 terminator = \r\n [he3_polariser] desc = "3He Polariser" driver = "he3_polanal" has_anal = false has_pol = true imptype = polariser ip = 10.157.205.2 port = 55013 terminator = \r\n [ls336_01] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.28 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_02] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.29 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_04] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.30 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_05] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.54 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_06] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.61 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_08] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.55 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_11] desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.27 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_12] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.31 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls340_01] asyncqueue = sct desc = "Lakeshore 340 temperature controller" driver = "ls340" imptype = temperature ip = 137.157.201.86 port = 4001 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls340_02] asyncqueue = sct desc = "Lakeshore 340 temperature controller" driver = "ls340" imptype = temperature ip = 137.157.201.86 port = 4002 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls340_11] desc = "Lakeshore 340 temperature controller" driver = "ls340" imptype = temperature ip = 137.157.201.86 port = 4001 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls370_1] desc = "Lakeshore 370 Resistance Bridge" driver = "lakeshore_m370" imptype = temperature ip = 10.157.205.42 port = 4001 tol = 1.0 [mercury_01] assoc = 00000124 cards = HHHVLTTP desc = "Oxford Mercury temperature controller (12T)" driver = "oxford_mercury" imptype = temperature ip = 10.157.205.5 port = 7020 ptol = 5 terminator = \n ttol = 1.0 vtol = 5 timeout = 2000 [mercury_02] assoc = 00000124 cards = HHTVTTTP desc = "Oxford Mercury temperature controller (CF10)" driver = "oxford_mercury" imptype = temperature ip = 10.157.205.46 port = 7020 ptol = 5 terminator = \n ttol = 1.0 vtol = 5 timeout = 2000 [mercury_03] assoc = 00000123 cards = HHHNNTTT desc = "Oxford Mercury temperature controller ()" driver = "oxford_mercury" imptype = temperature ip = 10.157.205.47 port = 7020 ptol = 5 terminator = \n ttol = 1.0 vtol = 5 timeout = 2000 [normal_m2s2] desc = "This sets speed and acceleration for the default extension of the m2 and s2 axes" imptype = m2s2_axes [normal_sample_stage] desc = "This is the default sample stage configuration" imptype = motion_axis [protek_01] asyncqueue = sct desc = "Protek Multimeter" driver = "protekmm" imptype = multimeter ip = 10.157.205.36 port = 4001 [protek_02] asyncqueue = sct desc = "Protek Multimeter" driver = "protekmm" imptype = multimeter ip = 10.157.205.37 port = 4001 [vf1_west6100] asyncprotocol = modbus_ap desc = "VF1 Blue furnace 6100 temperature controller" dev_id = 1 driver = "west_6100" imptype = temperature ip = 10.157.205.24 port = 502 timeout = 2000 [vf2_west6100] asyncprotocol = modbus_ap desc = "VF2 Blue furnace 6100 temperature controller" dev_id = 1 driver = "west_6100" imptype = temperature ip = 10.157.205.25 port = 502 timeout = 2000