[Default] cascade = sample_stage:normal_sample_stage enabled = True [B1] datype = B enabled = False id = 1 implementation = none name = magnet1 optype = magnetic_field [Function_Generator] datype = V enabled = False id = 1 implementation = none name = pulser optype = function_generator [High_Voltage] datype = V enabled = False id = 1 implementation = none name = hv_val optype = multimeter [I1] datype = I enabled = False id = 1 implementation = none name = curr1 optype = multimeter [I2] datype = I enabled = False id = 2 implementation = none name = curr2 optype = multimeter [Power Supply] datype = V enabled = False id = 1 implementation = none name = power_supply optype = power_supply [T1] datype = T enabled = False id = 1 implementation = none name = tc1 optype = temperature [T2] datype = T enabled = False id = 2 implementation = none name = tc2 optype = temperature [T3] datype = T enabled = False id = 3 implementation = none name = tc3 optype = temperature [T4] datype = T enabled = False id = 4 implementation = none name = tc4 optype = temperature [T5] datype = T enabled = False id = 5 implementation = none name = tc5 optype = temperature [T6] datype = T enabled = False id = 6 implementation = none name = tc6 optype = temperature [V1] datype = V enabled = False id = 1 implementation = none name = volts1 optype = multimeter [V2] datype = V enabled = False id = 2 implementation = none name = volts2 optype = multimeter [sample_stage] enabled = Always implementation = normal_sample_stage name = sample_stage optype = motion_axis [agilent_33220A] asyncqueue = sct desc = "Function Generator" driver = agilent_33220A imptype = function_generator ip = 10.157.205.16 port = 5025 [isotech_ps] desc = "Isotech Power Supply:Baud=2400,Data=8,Stop=1,Parity=None,Flow=None" driver = "isotech_ps" imptype = power_supply ip = 137.157.202.79 port = 4001 [julabo_lh45] ctrl_sensor = "bath" desc = "Julabo temperature controller" driver = "julabo_lh45" imptype = temperature ip = 10.157.205.39 port = 4001 tol = 5.0 type = T [ls336_01] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.28 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_02] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.29 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_04] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.30 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [ls336_12] asyncqueue = sct desc = "Lakeshore 336 temperature controller" driver = "ls336" imptype = temperature ip = 10.157.205.31 port = 7777 terminator = \r\n tol1 = 1.0 tol2 = 1.0 [mercury_01] assoc = 00000124 cards = HHHVLTTP desc = "Oxford Mercury temperature controller (12T)" driver = "oxford_mercury" imptype = temperature ip = 10.157.205.5 port = 7020 ptol = 5 terminator = \n timeout = 2000 ttol = 1.0 vtol = 5 [mercury_02] assoc = 00000124 cards = HHTVTTTP desc = "Oxford Mercury temperature controller (CF10)" driver = "oxford_mercury" imptype = temperature ip = 10.157.205.46 port = 7020 ptol = 5 terminator = \n timeout = 2000 ttol = 1.0 vtol = 5 [mercury_03] assoc = 00000123 cards = HHHNNTTT desc = "Oxford Mercury temperature controller ()" driver = "oxford_mercury" imptype = temperature ip = 10.157.205.47 port = 7020 ptol = 5 terminator = \n timeout = 2000 ttol = 1.0 vtol = 5 [normal_sample_stage] desc = "This is the default sample stage configuration xyz translation omega rotation but no tilt axes" imptype = motion_axis [protek_01] asyncqueue = sct desc = "Protek Multimeter" driver = "protekmm" imptype = multimeter ip = 10.157.205.36 port = 4001 [protek_02] asyncqueue = sct desc = "Protek Multimeter" driver = "protekmm" imptype = multimeter ip = 10.157.205.37 port = 4001