The TASMAD program (hereafter referred to as MAD) is used to control all spectrometer activity on triple-axis instruments. It includes motor movement, scans in Q-E space and, where appropriate, control of power supplies, flippers, temperature, etc.
sc a1=0 da1=1 np=6indicates that everything between the s and 6, inclusive, is to be typed by the user.
There are a few rules : - An input line must always begin with a command. - A command MUST always be abbreviated to its first TWO relevant letters, e.g. CO is equivalent to COU or COUNT but for SetZero type SZ or SZERO and so on. - A command must be separated from information which follows on the same line by at least one space. - Only one command may be given per line of input. However this does not exclude using, for example, the DRIVE command to drive several or even all motors. - All command lines are terminated by a carriage return <CR>. So do not forget to put one <CR> ( or more) at the end of your jobfile. Most commands are followed either by: Syntax type (A) (A) a sequence of variable names e.g. DM,DA,SS (carry out command given on variables DM, DA, SS) Note : that for this type of syntax (type A) the only acceptable variable separators are ' ' (i.e. a space), ',' and '-' (' ' and ',' are equivalent). Syntax type (B) (B) a sequence of variable names and values e.g. AS=3.24,CC=90 (AS is set to value 3.24 and CC to 90) e.g. QH=1,0,2.0 (variable QH takes the value 1 and the following variables in storage [QK, QL] take the values 0 and 2 ) e.g. QH=1,0,2.0,AS=3.24,CC=90 (a combination of the above) In commands involving this construction type (B) the program echoes the variable names and values it has understood. Possible separators are ',' and ' ' ('space') There is a third type of commands which requires no parameters. These commands are:- AUTO, EXIT, HELP, LIST, LL, LE, LL, LM, LS, LT, LZ, LD, PAL, SAVE and SWITCH.
CL CLear : Unfixes one or more motors or power supplies. CO COunt : Counts for given preset TIme or MoNitor. DO DO : Runs a jobfile without testing the syntax first. DR DRive : Changes a variable and drives spectrometer to its new position. FI FIx : Fixes a given motor or power supply, FIx without argument will give a list of fixed motors and power supplies. FM FindMax : As FindZero but SetZero is not performed, the spectrometer is only driven to the maximum. FZ FindZero : Scans a simple variable, finds maximum, drives to maximum and performs a SetZero with the given value. LI LIst : Listing of variables and parameters. LE ListEnergies Energies, k and Q values. LL ListLimits Limits and zeros. Same as lz. LZ ListZero Limits and zeros. Same as ll. LM ListMach Machine parameters. LS ListSample Sample parameters. LT ListTargets Targets and positions. LO LOg : Controls terminal logging. OF OFf : Turns flipper off. ON ON : Turns flipper on. OU OUtput : Defines output variables. PA Pol.An. : Defines a polarization analysis file (default file ext'n is .PAL). PR PRint : Prints one ore more variables or parameters. SC SCan : Scans a variable with given or previously defined increment, number of points and time interval or monitor count. SE SEt : Sets a parameter value. FS ScanFast : Scans a variable quickly. SW SWitch : Sets some switches. SZ SetZero : Sets the zero point offset of a variable.
CL(EAR) : The CLEAR command un-fixes a previously fixed motor or power supplies. Issued alone it un-fixes all previously fixed motors and power supplies. CLEAR is a command with type A syntax. In all cases the motors or supplies which have been cleared are listed by THE Program. e.g. CL I3,RA,I4<CR> CL<CR>
CO(UNT) : Counts for a given preset TIme or MoNitor. This is a command of type B syntax. If the command is issued alone, the preset used will be that most recently set. However, the preset may also be specified on the same line as the COUNT command. (For use of COnt in a P.A. file, see SCan and PA). e.g. CO TI=10<CR> (count for 10 seconds) CO MN=100<CR> (count for 100 M1 counts) CO<CR>
DO : Runs a jobfile without testing the syntax. The jobfile system enables a series of commands to be executed in sequence without the operator being present. The DO command is identical to the RUN command except that the 'dry run', i.e. the syntax and limit violation check, is not performed. Those who like forests prefer the DO command to RUN e.g. DO MYJOB<CR> The DO command is also used to change monochromators automatically , respectively to change zeroes and d-spacing after a (manual!) change of the analyzer. For each type of monochromator or analyzer available there is a .JOB file. After changing the monochromator (analyzer), do not forget to drive the incident (final) wavevector to the required value as this is not done in the .JOB file. For analysers, do not forget to SEt SA (sense of diffusion on the analyser) to the required value as it may have been changed by the job file in order to set the proper zero of A5. e.g. DO PG002M<CR> for graphite 002 monochromator DO HEUSLA<CR> for heusler analyzer A list of available analyzers and monochromators can be found in the userguide, or be obtained by typing on any terminal connected to the instrument computer "DIR/PROT .JOB".
DR(IVE) : Changes variables which describe the spectrometer configuration in some way. These variables have always a current position (actual value) and a target value. Under normal circumstances, targets and positions are equal within a small error. Definition of wavevectors : Ki, Q, and Kf are defined by the current values of the Two-Theta angles , A2, A4, A6 respectively. Therefore, it is possible (after an abort or an explicit motor drive) that the spectrometer is not really at the given position in Q-energy space, but every unperturbed drive of Q-energy will restore the correct position in Q-energy space: that means that all the four variables Qh, Qk, Ql and EN will be driven (explicitly or implicitly) to their target values if (at least) one of them is explicitly driven or scanned. Motor angles, wavevectors, energies, temperature, power-supply and Helmholtz-field values must all be driven. DRIVE is a command of type B syntax. The spectrometer is driven to its new position and the appropriate variable is altered in the memory. A DRIVE command will fail (non destructively) if: - a motor or power supply is protected or fixed - a software or hard limit is exceeded; the soft limits may be changed if necessary using the SET command provided the value desired is within the allowed range. - there is ambiguity among the driven variables. e.g. DR KI=2.662,A2=40<CR> sets two different targets for A2 and fails. Examples of valid DRive commands: DR A1=10,A2=20<CR> move A1 to 10 and A2 to 20 degs DR EI=14<CR> moves A1 and A2 to give an incident energy of 14 whichever unit was chosen at start-up. DR QH=1,0,0,0<CR> moves the spectrometer at fixed KI or KF depending on the value of FX - so that QH=1,QK=0, QL=0 and EN=0 If one of QH, QK, QL and EN is driven, ALL the others are taken into consideration. e.g. DR EN=5<CR> uses the value of EN specified and the existing target values of QH, QK and QL and makes the appropriate spectrometer movements taking account of the value of FX. It is thus a good habit to specify all four variables (QH, QK, QL & EN) each time one or several of them is to be changed.
FI(X) : Fixes a simple variable (i.e. a variable that is directly connected with the position of a spectrometer motor , or the value of a current) The variable is fixed at its current value so that subsequent attempts to change the value will fail unless a CLEAR command is issued first. FIX is a command of type A syntax. The FIX command issued with no variable name gives a list of motors and supplies which are fixed. e.g. FI A3<CR>
FM : Find Maximum This is the same as FindZero except that the zero of the variable is not changed at the end of the scan. The syntax is the same as for SCAN.
FZ : Find Zero Scans a simple variable, finds the maximum (or minimum) intensity within the scanned region, drives to the maximum and then sets the zero of the scanned variable so that the zero-corrected current position of the variable is zero. More precisely, the command drives to the centre of gravity of the intensity distribution. The routine for finding the extremum is not that good and MAD frequently finds no extremum even when there is obviously one. In that case the variable is left at the last point of the scan. Example: MAD > fz a4 0 da4 0.2 np 7 ti 5 The syntax is as for SCAN.
LI(ST) : LIST gives a listing of all spectrometer variables and parameters. There are "subsidiary" commands LE, LL, LM, LS, LT and LZ as described below. LE : List Energies: Ei,ki,Ef,kf,QH,QK,QL,EN,QM,TT,TRT LL : List Limits. Gives a listing of all motor limits and zeros. For clarity, only non-zero zero-offsetss are displayed. The current motor position is also shown. LM : List Machine. Gives a listing of all machine parameters. LS : List Sample. Gives a listing of all sample parameters. LT : Lists Targets. Gives a listing of all target values (i.e. where the motors ought to be) and actual positions of the motors. If a motor has a zero-offset, this is also listed. The positions of disabled motors are indicated by "-". LD : List Diaphragms: Gives a listing of all diaphragm positions. LZ : Lists Zeros. Equivalent to LL (ListLimits). Note: The target values usually describe the actual spectrometer configuration and should be equal (within a certain tolerance) to the positions. Clear exceptions are for a power supply which has been turned disabled, the abort of a DRive via Interrupt and, for instance, the incident wavevector after a drive of A1 or A2.
LOg start : Starts the logging of the MAD terminal dialogue to file. LOg stop : Stops the logging of the MAD terminal dialogue to file. LOg new : Closes the current log file (if open) and opens a new log file.
ON and OF(F) : Both flippers may be turned ON or OFF. In all cases, the OFF command simply turns off the relevant power supplies. Thus OFF F1<CR> turns off flipper 1 If a flipper is already on, the ON command will have no effect.If it is off, the ON command will cause the most recent target values to be achieved. -For flippers F1 and F2, the OFF command sets the currents in both the vertical and horizontal-field coils of the flipper to zero. The ON command yields the following currents: F1:vertical-field current = IF1V horizontal-field current = KI*IF1H F2:vertical-field current = IF2V horizontal-field current = KF*IF2H The quantities IF1V etc can be changed by the SET command when appropriate values have been determined from calibration scans. Note that MAD Program automatically divides the horizontal current for you by the incident or final wavevector respectively. If the current in one of the supplies connected to a flipper is changed by an explicit DRIVE command of the power supply, the flipper may have the logical value OFF even though the currents in its coils are non-zero.(This is because it no longer behaves as a flipper.) Note that the ON and OFF commands are the only ones which can be used to change F1 and F2. Both ON and OFF are of type A syntax.
OU(TPUT) :Defines extra variables to be output. The teletype and disk-file output produced by a SCAN command usually consists of values of variables which are scanned in addition to values of M1, M2, time and detector counts. The OUTPUT command may be used to force the output of additional variables. The total number of variables which can be output (including those which are scanned and those which are referred to in a .PAL file but excluding monitor, time and detector counts) is ten (10) . Thus setting a variable to be output means that its value will be printed for every point in every scan until disabled. Typing OU with NO following variables will stop the output of ALL variables apart from scanned ones. Type A syntax. A variable that has to be output because it is scanned and has also been selected with the OUT command will only be output once. e.g. OU A3,A4<CR> A3 & A4 will be printed in addition to the scan variables. OU<CR> Stops all extra output
PA (Polarization Analysis): This command allows a polarization analysis loop to be carried out for each point in a scan. The commands for the polarization analysis loop are contained in a file whose default extension is .PAL .Thus the command: PA POLL<CR> causes the commands in file POLL.PAL to be executed for each subsequent scan. If no file name is given after the PA command, MAD Program asks for one. If several scans are to be run from the console with the same polarization analysis loop the 'PA loop retention' switch should be set to ON (see SWITCHES). In a jobfile every SCAN command should always be preceded by its own PA command. A .PAL file may contain ONLY the commands SE, CO, DR, ON and OFF i.e. those commands which refer to flippers, Helmholtz coils and counting. -For example, if POLL.PAL contains: OFF F1,F2 <CR> DR HX=5,0,5 <CR> CO MN=200 <CR> ON F1 <CR> CO MN=20 <CR> DR HX=0 10 0 <CR> OFF F1 <CR> CO MN=500 <CR> ON F1 <CR> CO MN=50 <CR> four counts will be carried out for each scan point: # cnt F1 F2 HX HY HZ MN (i) off off 5 0 5 200 (ii) on off 5 0 5 20 (iii) off off 0 10 0 500 (iv) on off 0 10 0 50 A preset monitor or time given in a .PAL file overrides that given in a SCAN command for which the .PAL file is executed. When the command PA is issued, the contents of the relevant .PAL file is listed at the terminal and its syntax is checked. A .PAL file is cancelled after a scan, except for scans from the terminal if the PA retention switch is set. Therefore, if scans are performed within a job file, the .PAL file required must be specified for each scan. When a .PAL file is executed, the position variables used in the file are included in the scan output at the terminal and in the .SCN file if space permits. Preference is given to variables defined in the SCAN command but .PAL file variables take precedence over variables requested by the OUTPUT command (see OUTPUT). A concatenated version of the .PAL file is written on lines 10 and 11 of the .SCN file. Up to 240 characters can be written in this way (see section VI). When a .PAL file is used, scan point output to the terminal or the .SCN file are labelled 1.1,1.2,1.3....1.n where n is the number of count instructions in the .PAL file. A .PAL file may not contain more than 6 COUNT commands.
PR(INT) : Prints the current value of one or more variables or parameters. PRINT is a command of type A syntax: e.g. PR A1,A5<CR> PR QH-EN,GM<CR>
SC(AN) : Scans a variable. All variables which may be driven may also be scanned. There are three major items to be known about the use of the scan command 1) syntax : 2) data files 3) scan output 1) Syntax : The SCan command is of type B syntax . The scan-increment, preset monitor (MN) (or time, TI) and the number of scan points (NP) may be specified by a SET command (done before the scan), by default (the most recently used values) or on the same line as the SCAN command. Any number (less than 10) of variables may be scanned in a single command. The value of the scanned variable given in the SCAN command is the CENTRAL point of the scan. The maximum number of points per scan is 100. For odd NP this means that the centre is at the middle of the scan; for even NP the centre is the first point after the middle example: SC A1=0,DA1=1,NP=3 --> A1= -1, 0, +1 SC A1=0,DA1=1,NP=6 --> A1=-3, -2, -1, 0, 1, +2 2) data files : All tas####.dat files are copied to the mainframe computer automatically. 3) Scan output : The SCAN command has type B syntax. The values of M1, M2, counting time and detector counts are printed on the teletype for each point as are the scanned variables (i.e. the variables given in the SCan command line). Any additional variables requested (see OUTPUT ) are also printed. When a scan terminates, MAD Program examines the data and tries to find the centre of a peak or dip which may have ocurred in the detector. The method involves moments of the measured count distribution and may not be reliable if the peak/dip is ill-defined or if there is a sloping background. Specially the width is calculated from the first and second moment and is not necessary identical to the FWHM. For information on scans involving polarization analysis loops see the PA command. 4) examples : e.g. SC A2=-40,DA2=0.1,NP=11,TI=10<CR> scans A2, in steps of 0.1, about A2=-40 degrees for 10 seconds per point. SC A3=20.2,A4=40.4,DA3=-0.1,DA4=-0.2<CR> gives a theta-two-theta scan. If NP and TI have not been changed since the example above, there will be 11 points each counted for 10 seconds. SC QH=1,0,0,0,DQH=0,0,0,0.1,NP=31,MN=100<CR> causes a constant-Q scan, with an energy step of 0.1 (meV or THz) depending on the start-up conditions) to be carried out at Q=(1,0,0). There are 31 points each counted for 100 monitor counts. If the user now types SC EN=1.1<CR> The constant-Q scan will be repeated, centered at an energy transfer of 1.1 (meV or THz). As with the DRIVE command, scans in Q-E space are carried out at fixed KI (FX=1) or fixed KF (FX=2). During a scan with Kf fixed (i.e.FX=2) the program will automatically check and adjust A5 and A6; for Ki fixed (FX=1) however, MAD Program will not adjust at check and adjust at every point A1 and A2 because these variables are not likely to move in a Ki-fix scan. SC EI=14,DEI=0.1,NP=9,TI=1<CR> causes a scan of the incident energy to be performed.Such a scan may be carried out independently of the value of FX.
SE(T) : This command is used to change the values of parameters which do not directly alter the spectrometer configuration (variables which do alter the spectrometer configuration must be changed with the DRIVE command). The parameters which may be changed using SET are given in section V; in general these are instrument parameterssuch as monochromator and analyzer d-spacings, sample parameters, motor limits and zeroes, and steps for scans MAD Program echoes the values which it has understood. SET is a command of type B syntax. e.g. SE DM=3.355,DA=3.355<CR> sets dM and dA to 3.355
ScanFast | Scans a simple variable quickly. The variable is driven from start to end without stopping and measurements are made on the fly. Only one simple parameter may be scanned and it moves at the speed as set up in the parameters in the motor controller. |
The parameters are similar to those for SCAN. The TI parameter sets the period between reads of the neutron counter. Reading stops when the motor stops moving. The values of NP and the motor increment are used merely to calculate the start and end points of the scan. At a later date, the syntax may be improved to allow these values to be specified directly. | |
Example:FS A1=6,DA1=1,NP=13,TI=2 --> A1 = 0 to +12 with readings every 2 secs. | |
All of the data is output to a disk file as with the SCAN command. | |
Any additionally requested variables (see OUTPUT) are also output. |
SZ : (SetZero.) This command sets the zero for a variable such that its current value of the zer point offset is change into the specified value. Obviously this command works only for variables that have a zero. e.g. PR A3 A3 -45.42 SZ A3= 45 Old values for A5 Lower=-182.11 Upper= 125.00 Zero= 25.00 Posn= - 45.42 Target= - 45.40 New values for A5 Lower=-162.11 Upper= 145.00 Zero= 45.00 Posn= - 20.42 Target= - 20.40
SW(ITCHES) : This command allows the user to set the switches described below. In response to the command SW, MAD generates output of the following form: 1 Powder Mode OFF 2 Polarization mode OFF Give Switch Number to change or RETURN to finish > To change a value of one switch, enter the appropriate number (from 1 to 2) and hit <Return>. To make no change, type only <Return>. Please note, that due to a bug in the Macintosh JDK at least two characters have to be entered which can be spaces. To change the value of switches without being prompted, issue a command of the form: sw <sn> <val> <sn> <val> ... where <sn> is a switch number in the range 1 to 2 and <val> is its new value. <val> may be either On, Off or Flip.
Example of phonon scan: SC QH=2.1 3.2 0 12 DQH=0 0 0 .1 NP=11 MN=1000 this means that the scan will be centered at hkl=2.1,3.2,0 and omega=12, with steps of .1 in omega and 11 points with monitor 1000 SC QH=2.1 3.2 0 12 DQH=.02 0 0 0 NP=11 MN=1000 scan centered at same position but scanned in the QH-direction with steps of 0.02 N.B.!!! 1. Always define increments for scanned variables (as DQH,DQK,DQL and DEN in example above) unless you know what you are doing (i.e MAD Program stores the old value of the steps, and will use these by default in a new scan, unless you define new steps). 2. The incoming neutron wavevector is defined in MAD Program by A2 and the monochromator d-spacing, under normal circumstances A1 should have the correct (i.e.half the value of A2) position, if not MAD Program will issue a warning message; the same holds for the definition of the final neutron wavevector by A6 and the position of A5.
Check of a graphite filter : Before aligning a PG-filter it is essential to set up the spectrometer in a configuration where most of the detected neutrons are 2*ki neutrons. This provides for the best count-rate sensitivity to filter misalignments. In practice one may proceed as follows: 1/ DR KI=2.662 SE DA=6.71 DR KF=2.662 This will result in 2*ki neutrons being reflected by PG(002) at the analyser position, while first-order neutrons are not reflected since PG(001) is extinct. 2/ DR QH=0.5,0.5,1.5,0 This will result in 2*Ki neutrons being reflected by a strong Bragg reflection at the sample position. Here it is assumed that the sample is a single crystal with a strong (113) Bragg peak, and no coherent elastic scattering at (0.5 0.5 1.5). One may then proceed with the alignment itself. In general it is sufficient to verify the orientation of the filter in the horizontal plane. Once this is done: 3/ SE DA=3.355 DR KF=2.662 N.B. If one attempts to align a PG-filter using a beam which contains a significant proportion of Ki neutrons, experience shows that one finds a transmission minimum for a filter orientation which is misset by a few degrees from the nominal orientation (c-axis parallel to neutron beam). This position, however, corresponds to a transmission minimum for Ki neutrons.
l : Two-axis mode : If you want to work in TWO-AXIS mode, just SEt SA to 0 ! This will change the zero of A5 by 90 and any following drive of Ki or Kf will drive the detector to zero and the analyser perpendicular to the beam. Due to the change of A5 zero the value of A5 will be ZERO (0!) with a analyser orthogonal to the scatterred beam. l : Constant QM Mode: If you have a powder sample and want to work at a given QM ( modulus of Q that you cannot drive), just SEt the sample lattice parameters (AS, BS, CS ) to 2 PI (6.2832) and lattice angles (AA, BB, CC ) to 90. Any subsequent drive of QH will drive the machine to the correct QM value. Use the powder switch to inhibit the A3 (q) movement. E.G. SE AS=6.2832 6.2832 6.2832 SE AA = 90 90 90 SE AX=1 0 0 0 1 0 FI A3 DR QH=.1 0 0 0 PR QM QM=.1 l : Constant DEN Mode : . An other tricky mode of operation is the constant DEN mode, not constant Ki or Kf mode but a mixture with either aconstant DEN mode or ( more tricky) a mode which keeps the difference between energy transfer and the final energy constant This gives a varying wavelength scan for scanning through a bragg peak or checking a filter transmission or a (fast) varying energy resolution useful on IN1 to have a good energy resolution at small EN [pfor phonons] and broad energy resolution at higher energy transfer [magnons]). For example : E.G. se FX=1 sc QH= 1 0 0 100 DQH=0 0 0 10 DEI=10 l : AUto command: If you have strange or obscure warnings or messages on the teletype, try first the AU(to) command. It will reinitialize all motor modules. This may cure the problem.
Variables are divided into five groups: (i) parameters which define some aspect of the instrument configuration but are not directly related to a motor angle or power supply value. These variables are changed by the SET command. (ii) parameters which relate to the sample.These are also changed by SET. (iii) limits and zeroes for motors and power supplies, also changed by SET. (iv) Variables which are explicitly or implicitly related to a motor position or power supply value. These variables are changed by the DRive command. (v) Increments (steps) for the variables of type (iv); these are changed by SET. The following list gives the variable identifiers and definitions, where the order is as the variables are stored in the program. P.A Variables : Variables marked with an asterisk are not recognized unless THE Program is run in polarization analysis mode(see SWitch).
DM Monochromator d-spacing []. DA Analyzer d-spacing []. SM Scattering sense at Mono (+ve to the left) SS Scattering sense at Sample (+ve to the left) SA Scattering sense at Analyzer (+ve to the left) ALF1 Horizontal collimation before mono [minutes FwHm] ALF2 Horizontal collimation mono to sample [minutes FwHm] ALF3 Horizontal collimation sample to anal. [minutes FwHm] ALF4 Horizontal collimation before detector [minutes FwHm] BET1 Vertical collimation before mono [minutes FwHm] BET2 Vertical collimation mono to sample [minutes FwHm] BET3 Vertical collimation sample to analyzer [minutes FwHm] BET4 Vertical collimation before detector [minutes FwHm] ETAM Monochromator mosaic [minutes FwHm] ETAA Analyzer mosaic [minutes FwHm] FX =1 for constant Ki; =2 for constant Kf NP Number of points in a scan TI Preset time [seconds] for a COunt or SCan MN Preset monitor for a COunt or SCan DTL lower temperature error allowed [Kelvin] DTU upper temperature error allowed [Kelvin] *IF1V IF1V and IF2V are currents [Amps] in the vertical-field *IF2V coils for Flipper 1 and Flipper 2. *IF1H Horizontal-field currents are KI*IF1H for Flipper1 and *IF2H KF*IF2H for F2. *HELM Angle between axis of Helmholtz pair one and KI. remark: ALF1 to ETAA are not used by MAD Program but stored for your own convenience. Please DO NOT FORGET to update ALF1-ALF4 variable after collimator change to avoid confusion when you analyse your data after one or two years!
AS -\ BS +-- Sample unit-cell edges [] CS -/ AA -\ BB +-- Sample unit-cell angles [degrees] CC -/ ETAS Sample mosaic [minutes FwHm] AX -\ AY +-- Components of a recip. lattice vector in scattering plane AZ -/ of the sample. A3 is the angle between KI and (AX,AY,AZ). BX -\ BY +-- Components of a second distinct recip. lattice vector in BZ -/ the sample's scattering plane.
Lower and upper limits and zeros for all variables given in (iv) below. L, U and Z are appended as a prefix to the variable names to indicate Lower limit, Upper limit and Zero. Storage order is the same as for the corresponding variables, i.e. : LA1, UA1, ZA1, LA2, UA2, ZA2, LA3 ... (see (iv) below).
A1 Monochromator angle (Bragg angle in degrees) A2 Scattering angle at mono. (twice Bragg angle in degrees) A3 Sample angle (degs) (A3=0 when (AX,AY,AZ) is along KI) A4 Scattering angle at sample [degrees] A5 Analyzer angle (Bragg angle in deg, TOPSI: not used) A6 Scattering angle at analyzer (twice A5 in deg., TOPSI: not used) SINQ Instruments: MCV Mono curvature vertical SRS Sample table second ring ACH Anal curvature horizontal MTL Mono lower translation MTU Mono upper translation STL Sample lower translation STU Sample upper translation ATL Anal lower translation ATU Anal upper translation MGL Mono lower goniometer (Reserved) SGL Sample lower goniometer SGU Sample upper goniometer AGL Anal lower goniometer (Reserved) SRO Sample sample table ring rotation. D1T D1B D1R D1L Diaphragm 1 (top/bottom/right/left) D2T D2B D2R D2L Diaphragm 2 (top/bottom/right/left) D3T D3B D3R D3L Diaphragm 3 (top/bottom/right/left) ILL Instruments: CH Monochromator changer position [degrees or mm] GM Monochromator goniometer angle [1 unit = 4] RM Monochromator curvature GL Sample goniometer angle; lower arc [1 unit = 4] GU Sample goniometer angle; upper arc [1 unit = 4] TA Analyzer translation [ ? mm] GA Analyzer goniometer angle [ .4degrees] RA Analyzer curvature EI Incident neutron energy [THz or meV] KI Incident neutron wavevector [ -1] EF Final neutron energy [THz or meV] KF Final neutron wavevector [ -1] QH -\ QK +-- Components of Q in Reciprocal Lattice Units [R.L.U.] QL -/ EN Energy transfer; +ve neutron energy loss [THz or meV] QM Length of Q [ -1] TT (T) Temperature of sample thermometer [K] TRT(RT) Temperature of regulation thermometer [K] (can only be printed out)
*I1 -\ *I2 \ *I3 +-- power supply current values [A] . / *I6 -/ *HX -\ Components of Helmholtz fields at sample in Oersteds. *HY +-- HX is parallel to Q and HY is perpendicular to Q in *HZ -/ the scattering plane. *F1 -\ Status of flippers one and two; these variables take the *F2 -/ values ON or OFF.
For all variables A1 through T in the list of type (iv) variables above, the identifier for the step used with a SCan command is obtained by prefixing the variable name with the letter D. Storage order is DA1, DA2, DA3....etc as for type (iv) variables above.