sans/config/hmm/detector.tcl
Use dns-name for voltage controller address.
sans/config/motors/motor_configuration.tcl
Set det home position.
SICS-122 Added FastShutter variable and configured det motor with an action object to set the FastShutter variable.
SICS-248 Replaced beamstop motor objects with beamstop action objects.
action.[ch]
The action object factory will eventuall be defined here.
SICS-122 Currently there is just a funcion which sets the FastShutter variable
beamstopaction.c
Added motion control enabled check.
Added "list" subcommand.
Makefile
Compile action.c
motor_dmc2280.c
The status check command now always checks the TI1 and TI0 interrupts.
Added action-object configuration parameter. Call AO_istatus with TI1
if configured with an action object.
r2674 | ffr | 2008-08-13 14:16:30 +1000 (Wed, 13 Aug 2008) | 26 lines
You can now run the oscillating collimator for a specified number of cycles.
A MOTEND event is now sent when the oscillator stops.
Also temporarily set status to eEager to allow changing the motor accesscode parameter while something else is running, (eg a counter)
motor.c
finishDriving is no longer static so we can call it from the oscilator and generate a MOTEND event.
west4100.c
Return 'success' from wrapper on "controlsensor" and "sensorlist" queries so we can test and capture their values in scripts.
Makefile
Compile the quokka beamstopaction object
site_ansto.c
Add the MakeActionObject command. Currently only makes the hardcoded beamstopaction object
obpar.c
Report object name and parameter on an illegal attempt to set a parameter
hmm_configuration_common_1.tcl
Add oscillating collimator control flag for Wombat. If true we use hmm to start the histogram server instead of hmc. TODO remove hmc and always use hmm.
hipd/config/motors/motor_configuration.tcl
Don't load anticollider config twice. Fix oct limits
wombat_configuration.tcl
Environment configuration must be loaded before running server_init.
hrpd/config/hmm/hmm_configuration.tcl
Fix default time-bin to match 10Hz frame frequency
hrpd/config/motors/motor_configuration.tcl
Added dummy motor for testing.
reflectometer/config/hmm/detector.tcl
Fill in dhv1 configuration parameters.
sans/config/hmm/detector.tcl
Enable detector voltage control
sans/config/hmm/hmm_configuration.tcl
SICS-227 set default resolution to 192x192
sans/config/motors/motor_configuration.tcl
Added dummy motor for testing
quokka parameters.tcl
Fix L2mm calculation, Fix SICS-228 users cannot set rotapdeg
beamstopaction.[ch]
NEW: Implements an action command to drive the quokka beamstops up and down.
r2670 | ffr | 2008-08-07 13:17:29 +1000 (Thu, 07 Aug 2008) | 53 lines
Status is now updated on demand.
A status request returns a ready status message for the chopper as well as updating the chopper parameters.
We don't compensate for MW CMW on choppers 2 and 3.
PHASETOL=0.2
You can read the frequency from chopper one.
r2193 | ffr | 2007-10-23 12:58:13 +1000 (Tue, 23 Oct 2007) | 8 lines