Commit Graph

501 Commits

Author SHA1 Message Date
Ferdi Franceschini
2afcb043c3 Generate TCL code for syringe and mvp wrappers. 2014-10-17 16:42:51 +11:00
Ferdi Franceschini
73181a43d9 Wrapper templates to load syringe pump and mvp valve via sics_config.ini. 2014-10-17 16:42:50 +11:00
Douglas Clowes
0cd3e85607 Add a driver for the 3He Polariser/Analyser (rudimentary) 2014-10-16 15:52:30 +11:00
Ferdi Franceschini
d8f5030a8d SICS-795 Bring GIT up to date with changes made on ics1-wombat. 2014-10-08 20:29:23 +11:00
Ferdi Franceschini
9720f1d0f0 SICS-788 Guard against integer division. 2014-10-08 19:59:22 +11:00
Ferdi Franceschini
3a475196a0 SICS-788: Some divisions in Tcl macros will be truncated if the values are integers.
An integer division was caused here by the fix to SICS-785
2014-10-08 19:56:59 +11:00
Ferdi Franceschini
3b35308bf2 SICS-786 SICS locked up while counting on Taipan
An in-situ hack that was done on Wombat was accidentally committed.
2014-10-08 19:44:29 +11:00
Douglas Clowes
b0e4c3a85b Better checks and state machine for Knauer pump 2014-10-07 15:03:52 +11:00
Douglas Clowes
91b7c0b6eb Reasonably working Knauer pump driver 2014-10-07 15:03:48 +11:00
Douglas Clowes
5ba5af5db8 Reworking the Knauer 2014-10-07 15:03:43 +11:00
Douglas Clowes
a51ce71999 Major revision of the Knauer pump driver 2014-10-07 15:03:28 +11:00
Douglas Clowes
591c602da2 Regen SCT drivers 2014-10-03 10:17:46 +10:00
Douglas Clowes
c6abb1fabd Slight change to the way we do PID in SCT files 2014-09-30 17:24:58 +10:00
Douglas Clowes
98b5a89225 There is no mkdriver_args 2014-09-26 15:30:25 +10:00
Douglas Clowes
cf77588861 Add some more checking and fix drive end bug 2014-09-22 13:48:49 +10:00
Ferdi Franceschini
cf386ec3ef SICS-781 lakeshore 370 driver does not save data. 2014-09-19 12:16:31 +10:00
Douglas Clowes
b3d8f1bdae Regenerate knauer_pump.sct 2014-09-19 12:08:13 +10:00
Douglas Clowes
522865f264 Restructure knauer_pump.sct 2014-09-19 12:07:51 +10:00
Douglas Clowes
1a15aa5de6 Generated Knauer driver 2014-09-18 17:07:30 +10:00
Douglas Clowes
12d4e7dce5 First pass driver for the Knauer BlueShadow Pump 40P 2014-09-18 17:07:00 +10:00
Douglas Clowes
e8ec81ad5d SICS-776 Close the anti-collider file 2014-09-12 10:40:56 +10:00
Douglas Clowes
0cb3f4f91c Regenerated drivers 2014-09-11 13:29:52 +10:00
Douglas Clowes
a9a20b4855 Regenerate the ls218, nhq200 and sr630 drivers 2014-09-10 14:27:11 +10:00
Douglas Clowes
c6d2245941 Move ls218, nhq200, sr630 from environment to detector 2014-09-10 14:26:16 +10:00
Douglas Clowes
0867f5a315 Update "Decimal" processing for 4100/6100 2014-09-10 14:22:50 +10:00
Douglas Clowes
b127f49b33 Pullback change from Quokka 2014-09-09 2014-09-09 16:56:29 +10:00
Douglas Clowes
6738a0844d Add the Robots (Robbie and Rosie) for Echidna 2014-09-08 15:56:20 +10:00
Douglas Clowes
e6925423e3 Regenerate the SR630 driver with 600 second polls 2014-09-08 13:45:40 +10:00
Douglas Clowes
55a0055bd3 West 6100 driver 2014-09-05 16:09:36 +10:00
Douglas Clowes
24c8792467 SR630 reduce to 8 channels and 600 second polls, change driver name 2014-09-04 09:26:03 +10:00
Douglas Clowes
8af9116667 Update the Stanford SR630 SCT file for ten channels 2014-09-03 13:01:35 +10:00
Douglas Clowes
6070706571 Stanford Research Systems Model SR630 Thermocouple Monitor 2014-09-02 12:01:47 +10:00
Douglas Clowes
a93819572a Regenerate template drivers 2014-08-19 11:43:45 +10:00
Douglas Clowes
6f5892f07d Change SCT wrappers to use ip_address and tcp_port 2014-08-19 11:27:43 +10:00
Douglas Clowes
288be8f1c2 Generate the green magnet wrapper TCL code 2014-08-18 12:48:01 +10:00
Douglas Clowes
273c26cc22 Add a wrapper for the green magnet 2014-08-18 12:46:48 +10:00
Douglas Clowes
6f5f2b69cf Make Agilent use mkWrapper 2014-08-18 12:42:35 +10:00
Douglas Clowes
8541f7cd90 Remove extra makesctcontroller from Agilent 2014-08-15 12:21:36 +10:00
Ferdi Franceschini
13003126a6 Use configured magnet name in OxfordSet commands.
Also T3 is really pressure.
2014-08-08 11:52:04 +10:00
Ferdi Franceschini
944902c9d4 Added sct wrapper to load legacy sct_oxford_labview.tcl driver. 2014-08-08 11:51:49 +10:00
Ferdi Franceschini
639e4dc3c8 Generated sct tcl drivers from sct templates. 2014-08-06 11:20:46 +10:00
Ferdi Franceschini
2c753a3f18 Make sample stages configurable and add Oxford magnet sample stick motor as an option. 2014-08-06 10:08:12 +10:00
Ferdi Franceschini
6b8d9d88fa The default interval of five seconds seems to be working for everyone so let it be. 2014-08-06 10:08:11 +10:00
Douglas Clowes
a761136b48 Regenerate modified drivers 2014-08-05 12:23:33 +10:00
Douglas Clowes
17315b15c7 Remove hand-coded config for generated in Oxford ITC-500 2014-08-04 15:46:16 +10:00
Douglas Clowes
39519d8c1c Don't register poll/write when simulating in LS-3xx drivers 2014-08-04 15:45:59 +10:00
Douglas Clowes
5112af83fd SICS-697 Decorate LS-370 with permlink 2014-08-04 15:42:08 +10:00
Douglas Clowes
dda4a0f8f6 Fix erroneous filenames that match other files 2014-07-23 16:20:34 +10:00
Douglas Clowes
ab3d7c5adf Remove explicit test debug_threshold from SCT files and regenerate 2014-07-21 10:58:01 +10:00
Ferdi Franceschini
0becbe914a Use the sct_pulser sctcontroller generated from the agilent_33220A.sct wrapper. 2014-07-18 15:54:59 +10:00