@ -41,7 +41,11 @@ This means the log file has been started at August, 8, 2001 at 00:01:01.
There is a new log file daily. Load appropriate files into the editor and
look what really happened.
</p>
<p>
Another good ideas is to use the unix command grep on assorted log
files. A grep for the strings ERROR or WARNING will more ofteh then
not give an indication for the nature of the problem.
</p>
<p>
The log files show you all commands given and all the responses of the system.
Additionally there are hourly time stamps in the file which allow to narrow
@ -63,12 +67,8 @@ The log files show you all commands given and all the responses of the system.
<dt>EL737__BAD_BSY
<dd>A counting operation was aborted while the beam was off. Unfortunately,
the counter box does not respond to commands in this state and ignores the
stop command sent to it during the abort operation. This can be resolved by
the command:
<pre>
counter stop
</pre>
when the beam is on again.
stop command sent to it during the abort operation. This can be
safely ignored, SICS fixes this condition.
</dl>