@@ -66,6 +66,7 @@ $\langle$scandata {\footnotesize ?}$\rangle\equiv$
\mbox{}\verb@ SConnection *pCon;@\\
\mbox{}\verb@ char pRecover[1024];@\\
\mbox{}\verb@ char pHeaderFile[1024];@\\
\mbox{}\verb@ int (*PrepareScan)(pScanData self);@\\
\mbox{}\verb@ int (*WriteHeader)(pScanData self);@\\
\mbox{}\verb@ int (*WriteScanPoints)@\\
\mbox{}\verb@ (pScanData self, @\\
@@ -140,6 +141,9 @@ line is permitted.
finding data.
\item[pCon] The connection object to use for error reporting during scan
execution.
\item[PrepareScan] checks limits of scan variables and memorizes
important scan information. Sometimes this is not wanted, that is why
it is parametrized here.
\item[WriteHeader] is a pointer to a function which writes the header part
of the scan file. Replace this function if another data format is needed.
\item[WriteScanPoints] is a pointer to a function which will be called after
@@ -158,18 +162,18 @@ scheme is required especiallay for polarising scans.
counter to use and is initialized at creation of the scan data structure.
\item[pCountername] is the name of the counter used.
\item[iChannel] is the channel to use for counting. 0 is the main counter,
everything baove one of the monitors.
everything above one of the monitors.
\item[pCount, iCounts] is a dynamic array containing iCounts sets of
counting infomation. For each scan point this array holds the counts
measured. iCounts is also the current scan position.
\item[iWindow] the width of the window used for peak integration. See
integrate.w,c for more details.
\item[pCommand] It turned out that a way is needed to define user defined
speciality scans. This is implemented by setting the channel number to -10
and then have the scan command execute a Tcl script for each scan point.
This Tcl script has to return a Tcl list containing the values to enter for
counter and monitor for the scan point. pCommand now is the name of the
Tcl procedure to invoke.
speciality scans, especially for those magnetic polarized guys. The way
it is done is that scan has to be configured user. In this mode, ScanCount
will call a script which does everything necessary at the scan point,
including adding data to the data file. pCommand now holds the name of
the script to invoke.
\item[pSpecial] Usually NULL. A entry which allows customized scans to keep
some additional data in the scan data structure.
\end{description}
@@ -221,7 +225,23 @@ $\langle$scaninter {\footnotesize ?}$\rangle\equiv$
\mbox{}\verb@ /*@\\
\mbox{}\verb@ resets the configurable scan functions to their default values.@\\
\mbox{}\verb@ */@\\
\mbox{}\verb@@\\
\mbox{}\verb@ int NonCheckPrepare(pScanData self);@\\
\mbox{}\verb@ /*@\\
\mbox{}\verb@ a function for the PrepareScan field in the scan data structure@\\
\mbox{}\verb@ which does not check the boundaries of the scan as the default@\\
\mbox{}\verb@ PrepareScan does.@\\
\mbox{}\verb@ */@\\
\mbox{}\verb@ int AppendScanLine(pScanData self, char *line);@\\
\mbox{}\verb@ /*@\\
\mbox{}\verb@ AppendScanLine appends a line to the scan data file. When finished@\\
\mbox{}\verb@ it updates the position pointer in the file to point behind the@\\
\mbox{}\verb@ added line. @\\
\mbox{}\verb@ */@\\
\mbox{}\verb@ int StoreScanCounts(pScanData self, char *data);@\\
\mbox{}\verb@ /*@\\
\mbox{}\verb@ parses the numbers in data and stores them as the count and@\\
\mbox{}\verb@ monitor data for the current scan point.@\\
\mbox{}\verb@ */ @\\
\mbox{}\verb@/*------------------------ Interpreter Interface --------------------------*/@\\
\mbox{}\verb@ int ScanFactory(SConnection *pCon, SicsInterp *pSics, void *pData,@\\
\mbox{}\verb@ int argc, char *argv[]);@\\
@@ -279,6 +299,17 @@ summed counts and the variance. See the section on integrate for more
details.
\item[ResetScanFunctions] reinstalls the default functions for scan
processing into the ScanData structure.
\item[NonCheckPrepare] Before a scan is started, various data
structures in the scan object are initialized. Thereby the scan
boundaries are checked against the motor limits. For some scans this
is not feasible. This version omits this check and must be entered as
the PrepareScan function field in the scan data structure by code
using the scan module.
\item[AppendScanLine] appends a line to the scan file. This is useful
for user configured scans, for instance in polarisation mode.
\item[StoreScanCounts] parses the data given in data and stores the
numbers as count values as the count data for the current scan point.
Another feature for supporting user configurable scans.
\item[SimScan] creates a simulated gaussian peak with the given
parameters. Used for debugging several things.
\item[ScanFactory] is the SICS interpreter object creation function