- Many fixes to tas code

- fixes to amor writing and status code
- edited ecbcounter to stop at no beam
- updated documentation
- fixed a bug in project code affecting SANS
This commit is contained in:
cvs
2003-05-05 07:49:26 +00:00
parent 4ca2fcff60
commit 4ebf207325
25 changed files with 271 additions and 102 deletions

View File

@ -638,12 +638,13 @@ controller is connected to the computer systems through a GPIB bus and
controller. A A1931 temperature controller is configured into SICS
through the command:
<BLOCKQUOTE>
evfactory new temperature-name a1931 gpib-controller-name
evfactory new temperature-name a1931 gpib-controller-name gpibaddress
</BLOCKQUOTE>
This creates a new command temperature-name. gpib-controller-name is
the name of a GPIB controller within SICS. A GPIB controller is
configured into SICS with the command MakeGPIB as described in the
SICS managers documentation.
SICS managers documentation. gpibaddress is the address of the A1931 on the
GPIB bus.
</p>
<p>
A A1931 temperature device understands a couple of additional commands