Merge branch 'RELEASE-3_1'

Conflicts:
	sics/site_ansto/instrument/config/environment/hiden_xcs_sct.tcl
	sics/site_ansto/instrument/config/environment/temperature/sct_lakeshore_m370.tcl
	sics/site_ansto/instrument/hipd/wombat_configuration.tcl
	sics/site_ansto/instrument/kookaburra/kookaburra_configuration.tcl
	sics/site_ansto/instrument/pelican/pelican_configuration.tcl
	sics/site_ansto/instrument/reflectometer/platypus_configuration.tcl
	sics/site_ansto/instrument/util/gen_sct.py
This commit is contained in:
Douglas Clowes
2014-11-06 14:13:20 +11:00
52 changed files with 4133 additions and 3116 deletions

View File

@@ -10,7 +10,10 @@ foreach {var lname type priv units klass} {
wavelength wavelength float user Angstrom crystal
dOmega dOmega float user degrees crystal
gDQv gDQv float user none crystal
gDQh gDQh float user none crystal
scan_variable scan_variable text user none crystal
MainDeadTime MainDeadTime float user s detector
TransBackground TransBackground int user none detector
TransDeadTime TransDeadTime float user s detector
TransmissionTube TransmissionTube int user none detector
bkgLevel bkgLevel float user 1 experiment

View File

@@ -23,7 +23,28 @@ fileeval $cfPath(motors)/motor_configuration.tcl
#fileeval $cfPath(motors)/extraconfig.tcl
fileeval $cfPath(plc)/plc.tcl
fileeval $cfPath(counter)/counter.tcl
#fileeval $cfPath(environment)/temperature/lakeshore_218_sct.tcl
fileeval $cfPath(environment)/agilent_33220A_sct.tcl
fileeval $cfPath(environment)/isotech_ps_sct.tcl
fileeval $cfPath(environment)/temperature/sct_eurotherm_2000.tcl
fileeval $cfPath(environment)/temperature/eurotherm_m2000_sct.tcl
fileeval $cfPath(environment)/sct_keithley_2700.tcl
fileeval $cfPath(environment)/keithley_m2700_sct.tcl
fileeval $cfPath(environment)/temperature/lakeshore_218_sct.tcl
fileeval $cfPath(environment)/temperature/sct_lakeshore_336.tcl
fileeval $cfPath(environment)/temperature/ls336_sct.tcl
fileeval $cfPath(environment)/temperature/sct_lakeshore_340.tcl
fileeval $cfPath(environment)/temperature/ls340_sct.tcl
fileeval $cfPath(environment)/temperature/sct_lakeshore_370.tcl
fileeval $cfPath(environment)/temperature/lakeshore_m370_sct.tcl
fileeval $cfPath(environment)/temperature/mercury_base_sct.tcl
fileeval $cfPath(environment)/temperature/mercury_level_sct.tcl
fileeval $cfPath(environment)/temperature/mercury_pres_sct.tcl
fileeval $cfPath(environment)/temperature/mercury_scpi_sct.tcl
fileeval $cfPath(environment)/temperature/mercury_temp_sct.tcl
fileeval $cfPath(environment)/temperature/mercury_valve_sct.tcl
fileeval $cfPath(environment)/sct_protek_common.tcl
fileeval $cfPath(environment)/protekmm_sct.tcl
fileeval $cfPath(environment)/temperature/julabo_lh45_gen_sct.tcl
fileeval $cfPath(counter)/sct_bm.tcl
fileeval $cfPath(hmm)/hmm_configuration.tcl
fileeval $cfPath(nexus)/nxscripts.tcl

View File

@@ -0,0 +1,217 @@
[Default]
cascade = sample_stage:normal_sample_stage
enabled = True
[B1]
datype = B
enabled = False
id = 1
implementation = none
name = magnet1
optype = magnetic_field
[Function_Generator]
datype = V
enabled = False
id = 1
implementation = none
name = pulser
optype = function_generator
[High_Voltage]
datype = V
enabled = False
id = 1
implementation = none
name = hv_val
optype = multimeter
[I1]
datype = I
enabled = False
id = 1
implementation = none
name = curr1
optype = multimeter
[I2]
datype = I
enabled = False
id = 2
implementation = none
name = curr2
optype = multimeter
[Power Supply]
datype = V
enabled = False
id = 1
implementation = none
name = power_supply
optype = power_supply
[T1]
datype = T
enabled = False
id = 1
implementation = none
name = tc1
optype = temperature
[T2]
datype = T
enabled = False
id = 2
implementation = none
name = tc2
optype = temperature
[T3]
datype = T
enabled = False
id = 3
implementation = none
name = tc3
optype = temperature
[T4]
datype = T
enabled = False
id = 4
implementation = none
name = tc4
optype = temperature
[T5]
datype = T
enabled = False
id = 5
implementation = none
name = tc5
optype = temperature
[T6]
datype = T
enabled = False
id = 6
implementation = none
name = tc6
optype = temperature
[V1]
datype = V
enabled = False
id = 1
implementation = none
name = volts1
optype = multimeter
[V2]
datype = V
enabled = False
id = 2
implementation = none
name = volts2
optype = multimeter
[sample_stage]
enabled = Always
implementation = normal_sample_stage
name = sample_stage
optype = motion_axis
[agilent_33220A]
asyncqueue = sct
desc = "Function Generator"
driver = agilent_33220A
imptype = function_generator
ip = 10.157.205.16
port = 5025
[isotech_ps]
desc = "Isotech Power Supply:Baud=2400,Data=8,Stop=1,Parity=None,Flow=None"
driver = "isotech_ps"
imptype = power_supply
ip = 137.157.202.79
port = 4001
[julabo_lh45]
ctrl_sensor = "bath"
desc = "Julabo temperature controller"
driver = "julabo_lh45"
imptype = temperature
ip = 10.157.205.39
port = 4001
tol = 5.0
type = T
[ls336_01]
asyncqueue = sct
desc = "Lakeshore 336 temperature controller"
driver = "ls336"
imptype = temperature
ip = 10.157.205.28
port = 7777
terminator = \r\n
tol1 = 1.0
tol2 = 1.0
[ls336_02]
asyncqueue = sct
desc = "Lakeshore 336 temperature controller"
driver = "ls336"
imptype = temperature
ip = 10.157.205.29
port = 7777
terminator = \r\n
tol1 = 1.0
tol2 = 1.0
[ls336_04]
asyncqueue = sct
desc = "Lakeshore 336 temperature controller"
driver = "ls336"
imptype = temperature
ip = 10.157.205.30
port = 7777
terminator = \r\n
tol1 = 1.0
tol2 = 1.0
[ls336_12]
asyncqueue = sct
desc = "Lakeshore 336 temperature controller"
driver = "ls336"
imptype = temperature
ip = 10.157.205.31
port = 7777
terminator = \r\n
tol1 = 1.0
tol2 = 1.0
[mercury_scpi_01]
desc = "Oxford Mercury temperature controller in Mercury mode"
driver = "mercury_scpi"
imptype = temperature
ip = 10.157.205.5
permlink = LT
port = 7020
terminator = \r\n
tol = 1.0
valve_tol = 2
[mercury_scpi_02]
desc = "Oxford Mercury temperature controller in Mercury mode"
driver = "mercury_scpi"
imptype = temperature
ip = 10.157.205.47
permlink = LT
port = 7020
terminator = \r\n
tol = 1.0
valve_tol = 2
[normal_sample_stage]
desc = "This is the default sample stage configuration xyz translation omega rotation but no tilt axes"
imptype = motion_axis
[protek_01]
asyncqueue = sct
desc = "Protek Multimeter"
driver = "protekmm"
imptype = multimeter
ip = 10.157.205.36
port = 4001
[protek_02]
asyncqueue = sct
desc = "Protek Multimeter"
driver = "protekmm"
imptype = multimeter
ip = 10.157.205.37
port = 4001