#----- IPS magnet power supply ------
proc mfLayout args {
Group mf "magnetic field control"
}
proc makeIps args {
scanargs $args var -limit 0 -startRamp 0.5 -startScript 0 -port 0 -args
if {$limit == 0} {
error "limit argument required"
}
makenv mf ips -port $port
mf limit $limit
mf ramp $startRamp
mf startScript $startScript
Layout mf
appendVars mf.current/Tesla/Current mf/Tesla/Mag_Field
if {$startScript != 0} {
clientput "INIT ${startScript}_init $args"
${startScript}_init $args
}
}
proc mfAdvancedGroup {} {
Label "before changing the field limit look at the web page of [result device name] for the restrictions on [result Instrument]"
Tip max. limit [result mf maxlimit] \[Tesla\]
Input "field limit" "mf limit"
Tip "delay for auto persistent mode"
Input "pers. mode delay" "mf persdelay"
Tip "for fields higher than this value, slow ramp is used"
Input "trained up to" "mf trainedTo"
Newline
Label "Workaround for persistent switch problems:"
Newline
Tip "current \[in Tesla\] to go first in persistent mode"
Input "persistent current" "mf perscurrent"
Tip "wait time before going to zero \[sec\]"
Input "wait time" "mf perswait"
Tip "when field is below this value \[Tesla\]: normal operation"
Input "do workaround above" "mf perslimit"
}
proc mfGroup {} {
set startscript [result mf startScript]
if {$startscript eq "0"} {
showStatus mf
} else {
${startscript}_showStatus
}
Tip magnetic field set point \[Tesla\]
Input "set field" "run mf/[result mf targetValue]"
Tip do not wait on a drive command
CheckBox "no wait" "mf nowait"
Newline
RadioGroup "mf persmode"
Label "persistent mode:"
NoNewline
Tip "do not go into persistent mode for [result mf persdelay] seconds after any field change"
RadioButton 0 off
NoNewline
Tip "go into persistent mode immediately after changing the field"
RadioButton 1 on
if {[result mf persmode] != 1} {
NoNewline
Tip "go never into persistent mode (not recommended)"
RadioButton 2 "completely off"
}
if {[result mf perswitch] == 1} {
Label "the switch heater is on"
} else {
Label "the switch heater is off"
}
Tip ramp rate \[Tesla/min.\]
Tip the actual rate may be lower
Tip because of magnet limitations
Input "ramp rate" "mf ramp"
Group mfAdvanced "advanced settings"
}
proc checkMA7_init {arglist} {
if {[sicsdescriptor checkMA7_pars] eq "notfound"} {
makeobject checkMA7_pars array logged
checkMA7_pars makeitem mode
checkMA7_pars makeitem status
}
if {"[lindex $arglist 0]" eq ""} {
error "checkMA7_init needs asymmetric limit as argument"
}
checkMA7_pars makeitem asymmetric_limit [lindex $arglist 0]
checkMA7_pars makeitem symmetric_limit [result mf limit]
checkMA7_pars mode unknown
checkMA7_pars status 0
}
proc checkMA7_confirm {{value 0}} {
if {$value == 0} {return 0}
instconfig makeitem checkMA7_expected [result checkMA7_pars mode]
instconfig makeitem checkMA7_last [clock seconds]
checkMA7_pars status 0
mf reconnect
return 0
}
publishLazy checkMA7_confirm
proc checkMA7_restart {{value 0}} {
if {$value == 0} {return 0}
checkMA7_pars status 0
mf restart 1
return 0
}
publishLazy checkMA7_restart
proc checkMA7_showStatus {} {
Newline
set mode [result checkMA7_pars mode]
Label "MA7 in $mode mode"
Newline
set status [result checkMA7_pars status]
if {$status eq "0"} {
showStatus mf
} else {
if {$mode eq "symmetric"} {
set lab SYM
set other asymmetric
set olab ASY
} else {
set lab ASY
set other symmetric
set olab SYM
}
if {$status eq "check"} {
Newline
Style warning
Label "for keeping $mode mode:"
Newline
Label "check that the current cables are connected to COM and $lab"
Newline
Style warning
Label "for changing to $other mode:"
Newline
Label "change IPS parameters S11,S02 and S01 (see MA7 web page)"
Newline
Label "connect the current cables to COM and $olab"
Newline
Style warning
CheckBox "done" "checkMA7_confirm"
Newline
} else {
Newline
Style warning
Label "see the MA7 web page for the correct parameters on the IPS"
Newline
Style warning
Label $status
Style warning
CheckBox "click here when the parameters are correctly set" "checkMA7_restart"
Newline
}
}
}
proc checkMA7 {} {
set expected [silent undefined result instconfig checkMA7_expected]
if {[silent 0 result instconfig checkMA7_last] < [clock seconds] - 3600} {
set expected undefined
}
set ind [result mf inductance]
set rampt [result mf ramp]
set rampa [result mf ampRamp]
set sym [expr abs($rampt - $rampa * 6.8 / 96.636) < 0.001]
set asym [expr abs($rampt - $rampa * 6.2 / 100.657) < 0.001]
checkMA7_pars status 0
mf startScript checkMA7
if {$ind == 112} {
set mode symmetric
if {! $sym} {
checkMA7_pars status "S11 = $ind, S02/S01 do not match"
}
} elseif {$ind == 78.8} {
set mode asymmetric
if {! $asym} {
checkMA7_pars status "S11 = $ind, S02/S01 do not match"
}
} elseif {$ind == 0.0} {
error [result mf status]
} else {
if {$sym && !$asym} {
checkMA7_pars status "S11: $ind, S02: 96.636, S01.2: 6.8"
} elseif {$asym && !$sym} {
checkMA7_pars status "S11: $ind, S02: 100.657, S01.2: 6.2"
} else {
checkMA7_pars status "S11: $ind, S02/S01 bad"
}
}
if {[result checkMA7_pars status] ne "0"} {
error "inconsistent IPS parameters. please open 'magnetic field control'"
}
checkMA7_pars mode $mode
checkMA7_pars status 0
if {$expected ne $mode} {
checkMA7_pars status check
error "please open 'magnetic field control' to check the MA7 mode"
}
mf limit [result checkMA7_pars ${mode}_limit]
return done
}