deviceDesc = dry system
|
|
|
|
if {"[sicsdescriptor t]" != "notfound"} {
|
|
clientput [listexe]
|
|
stopexe t
|
|
clientput success
|
|
success
|
|
clientput "removeobject t"
|
|
removeobject t
|
|
}
|
|
|
|
# --- configuration script
|
|
config listen 1
|
|
|
|
# create the device
|
|
# change X77456 for X154360 when calibration exists
|
|
|
|
## Configuration for attocube testing:
|
|
#makenv tt -driver [lsdriver] {
|
|
# lsc_sensor tm A -sensor X71741 -sensorname top
|
|
# lsc_sensor ts B -sensor X68433 -sensorname bottom
|
|
# lsc_sensor tc C -sensor X154360 -sensorname middle
|
|
# lsc_loop set -loop 1 -channel B -maxheater 25W -resist 25Ohm
|
|
#}
|
|
|
|
# Configuration for braid thermal conductivity measurements:
|
|
makenv tt -driver [lsdriver] {
|
|
lsc_sensor CR2 A -sensor X148903 -sensorname CR2
|
|
#lsc_sensor ts B -sensor X68433 -sensorname platform
|
|
lsc_sensor SR2 C -sensor X148906 -sensorname SR2
|
|
lsc_sensor CZ2 D -sensor X142474 -sensorname CZ2
|
|
lsc_loop set -loop 1 -channel C -maxheater 25W -loopname braid -resist 81Ohm
|
|
}
|
|
|
|
tt set/limit 315
|
|
tt set/prop 15
|
|
tt set/integ 10
|
|
catch {
|
|
enableTable 0
|
|
}
|
|
|
|
# Add second LakeShore (LS336)
|
|
makenv ttb -driver 336_lsc -port lollypop-ls:7777 {
|
|
# Choose which brad is connecter and change the corresponding thermomemter calibration (copy from the top LakeShore 340)
|
|
lsc_sensor PLAT A -sensor X68433 -sensorname platform
|
|
lsc_loop set -loop 1 -channel A -maxheater 25W -resist 25Ohm -loopname platform -color green
|
|
}
|
|
|
|
ttb set/prop 25
|
|
ttb set/integ 20
|
|
ttb dblctrl/int2 100
|
|
|
|
|
|
|
|
if {0} {
|
|
|
|
# lakeshore 370
|
|
|
|
makenv tx -driver 370_lsc {
|
|
lsc_sensor Exhaust 1 pt1000e
|
|
# lsc_sensor Shield1top 2 pt1000e
|
|
lsc_sensor Shield1bot 3 pt1000e
|
|
lsc_sensor VTI 4 x68433
|
|
lsc_sensor Sample 7 x75610
|
|
#please set sample Thermpmeter to the real calib
|
|
GraphAdd tx.Exhaust K Stage2PT yellow
|
|
# GraphAdd tx.Shield1top K Shield1_top orange
|
|
GraphAdd tx.Shield1bot K Shield1_bot cyan
|
|
GraphAdd tx.VTI K VTI_HX orange
|
|
GraphAdd tx.Sample K Sample_T black
|
|
}
|
|
|
|
}
|
|
#debug tx
|
|
|
|
|
|
# --- compressor ---
|
|
makenv cp2800 cp2800
|
|
|
|
GraphAdd cp2800.inp_water_t C InpWater_C red
|
|
GraphAdd cp2800.out_water_t C OutWater_C blue
|
|
GraphAdd cp2800.oil_t C Oil_C green
|
|
GraphAdd cp2800.helium_t C Helium_C magenta
|
|
|
|
GraphAdd cp2800.high_side_p_min psi High_psi_min red
|
|
GraphAdd cp2800.high_side_p_max psi High_psi_max orange
|
|
GraphAdd cp2800.low_side_p_min psi Low_psi_min green
|
|
GraphAdd cp2800.low_side_p_max psi Low_psi_max dark_green
|
|
|
|
if {0} {
|
|
#---- Pressure gauge ---
|
|
|
|
makenv p pinp
|
|
GraphAdd p.a2 mbar P_pot yellow
|
|
GraphAdd p.a3 mbar P_VTI green
|
|
GraphAdd p.a4 mbar P_dump blue
|
|
GraphAdd p.a5 mbar Compress red
|
|
GraphAdd p.a6 mbar P3 cyan
|
|
GraphAdd p.a7 mbar P4 magenta
|
|
#GraphAdd p.gnd mV1 gnd blue
|
|
#GraphAdd p.max mV2 max red
|
|
|
|
|
|
#--- flow meter ---
|
|
|
|
makenv flow bronkhorst
|
|
|
|
appendVars flow/ff/flow flow.counter/float/counter flow.ff/ff/ff flow.fi/fi/fi
|
|
|
|
#--- cold trap ---
|
|
#makenv n2 n2_ccu ccu
|
|
#appendVars n2.upper/K2/N2_Upper n2.lower/K2/N2_Lower
|
|
|
|
#---pressure in front of pump---
|
|
#makenv nv nv_ccu ccu
|
|
#appendVars nv.flow/mbar/nv_Flow nv.autoflow.flowset/mbar/nv_Set
|
|
|
|
#GraphAdd nv.flow mbar pfront_flow 4
|
|
|
|
|
|
#--solenoid valve unit ---
|
|
|
|
#makenv mv svuold
|
|
makenv mv -driver svu {needle 1 bypass 2}
|
|
|
|
#--ACM Levelmeter---
|
|
makenv He acm
|
|
|
|
#GraphAdd He pF Helium_level 4
|
|
}
|