namespace eval hepump {
|
||||
}
|
||||
|
||||
proc stdConfig::hepump {{motname hemot}} {
|
||||
variable name
|
||||
|
||||
controller syncedprot
|
||||
prop write stdSct::complete
|
||||
pollperiod 1 1
|
||||
|
||||
obj HePump -int wr
|
||||
default 0
|
||||
prop enum xds35_auto,xds35_manual,sv65,other,no=-1
|
||||
prop help "xds35: scroll pump, sv65: leybold"
|
||||
prop read hepump::read
|
||||
prop write hepump::set_type
|
||||
prop @motname $motname
|
||||
prop health_cnt 0
|
||||
|
||||
kids "He pump ([silent xds35_auto result instconfig he_pump_type])" {
|
||||
node running -int wr
|
||||
prop enum 1
|
||||
prop check hepump::chk_running
|
||||
prop read hepump::get_running
|
||||
|
||||
node eco -int wr
|
||||
prop enum 1
|
||||
prop check hepump::set_eco
|
||||
prop read hepump::get_eco
|
||||
prop nonewline 1
|
||||
|
||||
node auto -int wr
|
||||
default 1
|
||||
prop enum 1
|
||||
prop check hepump::set_auto
|
||||
prop read hepump::get_auto
|
||||
prop nonewline 1
|
||||
|
||||
node valve -int wr
|
||||
prop enum closed,closing,opening,opened,undefined
|
||||
prop check hepump::check_valve
|
||||
prop write hepump::set_valve
|
||||
prop read hepump::get_valve
|
||||
prop buttontitle "operate valve"
|
||||
prop buttons open/2/2,3:close/1/0,1
|
||||
prop try 0
|
||||
|
||||
node eco_t_lim par 3
|
||||
prop help "switch off eco mode when T_set < eco_t_lim and T < eco_t_lim * 2"
|
||||
|
||||
node calib par 1
|
||||
|
||||
node health upd
|
||||
}
|
||||
}
|
||||
|
||||
proc hepump::set_type {} {
|
||||
sct update [sct target]
|
||||
return hepump::set_calib
|
||||
}
|
||||
|
||||
proc hepump::visible {pumpcode} {
|
||||
if {$pumpcode == 0} {
|
||||
set v true
|
||||
if {[silent 0 result instconfig he_pump_type] eq "other_pump_with_valve"} {
|
||||
set rv false
|
||||
} else {
|
||||
set rv true
|
||||
}
|
||||
} else {
|
||||
set v false
|
||||
set rv false
|
||||
}
|
||||
|
||||
foreach node "valve [sct @motname]" {
|
||||
if {[silent true hgetpropval [sct]/$node visible] ne $v} {
|
||||
hsetprop [sct]/$node visible $v
|
||||
}
|
||||
}
|
||||
foreach node "running eco auto eco_t_lim" {
|
||||
if {[silent true hgetpropval [sct]/$node visible] ne $rv} {
|
||||
hsetprop [sct]/$node visible $rv
|
||||
}
|
||||
}
|
||||
if {$pumpcode == 3} {
|
||||
set v true
|
||||
} else {
|
||||
set v false
|
||||
}
|
||||
if {[silent true hgetpropval [sct]/calib visible] ne $v} {
|
||||
hsetprop [sct]/calib visible $v
|
||||
}
|
||||
}
|
||||
|
||||
proc hepump::set_calib {} {
|
||||
set pumpcode [hvali [sct]]
|
||||
sct update $pumpcode
|
||||
if {$pumpcode < 0} { # no pump
|
||||
_[sct @motname] disconnect
|
||||
ignore_msg _[sct @motname] disconnected
|
||||
hepump::visible $pumpcode
|
||||
hsetprop [sct]/[sct @motname] group 0
|
||||
return idle
|
||||
} elseif {$pumpcode == 2} { # sv65
|
||||
set f 0.9
|
||||
hsetprop [sct]/[sct @motname] group 0
|
||||
} elseif {$pumpcode == 1} { # xds35_manual
|
||||
set f 0.6
|
||||
hsetprop [sct]/[sct @motname] group 0
|
||||
} elseif {$pumpcode == 0} { # xds35_auto
|
||||
set status [string trim [_[sct @motname] status]]
|
||||
if {$status eq "disconnected" || $status eq "offline"} {
|
||||
# clientput [_[sct @motname] hostport]
|
||||
_[sct @motname] reconnect
|
||||
}
|
||||
if {$status eq "no response"} {
|
||||
set pumpcode 1 ;# treat as manual
|
||||
hsetprop [sct]/[sct @motname] group "hepump valve motor (not connected)"
|
||||
} else {
|
||||
hsetprop [sct]/[sct @motname] group "hepump valve motor"
|
||||
}
|
||||
set eco [sctval [sct]/[sct @motname]/output1]
|
||||
if {$eco == 1} {
|
||||
set f 0.6 ;# this was 0.4
|
||||
} else {
|
||||
set f 0.6 ;# 0.95 at 30 mbar
|
||||
}
|
||||
} elseif {$pumpcode == 3} { # other
|
||||
hsetprop [sct]/[sct @motname] group "hepump valve motor"
|
||||
set f [hval [sct]/calib]
|
||||
} else { # other: should not happen
|
||||
error "illegal pump code"
|
||||
}
|
||||
hepump::visible $pumpcode
|
||||
if {$f != [silent $f hval /nv/calib/ln_per_min_per_mbar]} {
|
||||
nv calib/ln_per_min_per_mbar $f
|
||||
hsetprop /nv off_until [expr [DoubleTime] + 20]
|
||||
hsetprop /nv off_reason "pump mode changed"
|
||||
sct print "pump mode change: suspend needle valve control for 20 sec."
|
||||
}
|
||||
return idle
|
||||
}
|
||||
|
||||
proc hepump::read {} {
|
||||
set p [silent 0 result cc f]
|
||||
set f [silent 0 result nvflow]
|
||||
if {[hvali [sct]/eco] == 0 && $p > 1 && $f > 0.5 && $f < 25} {
|
||||
set health [expr 100 * $f / ($p * 0.5 - 0.5)]
|
||||
set health [expr [silent $health sct health] * 0.95 + 0.05 * $health]
|
||||
sct health $health
|
||||
if {abs($health - [silent 0 hval [sct]/health]) > 1} {
|
||||
sct health_cnt 0
|
||||
hupdate [sct]/health [format %.1f $health]
|
||||
} else {
|
||||
sct health_cnt [expr [sct health_cnt] + 1]
|
||||
if {[sct health_cnt] == 10} {
|
||||
if {$health > 100} {set health 100}
|
||||
catch {prep0 / "pump_health_update [result instrument] [format %.0f $health]"} msg
|
||||
}
|
||||
}
|
||||
} else {
|
||||
# reset filter
|
||||
hdelprop [sct] health
|
||||
}
|
||||
return [hepump::set_calib]
|
||||
}
|
||||
|
||||
proc hepump::set_valve_status {new} {
|
||||
set old [silent "" sct valvestatus]
|
||||
set path [sct objectPath]/status
|
||||
set status [hvali $path]
|
||||
if {$new ne "" || $old eq $status} {
|
||||
hupdate $path $new
|
||||
}
|
||||
sct valvestatus $new
|
||||
}
|
||||
|
||||
proc hepump::check_valve {} {
|
||||
set_valve_status ""
|
||||
sct try 5
|
||||
sct slowspeed 50
|
||||
}
|
||||
|
||||
proc hepump::set_valve {} {
|
||||
if {[sctval [sct parent]] != 0} return
|
||||
set val [hvali [sct]]
|
||||
if {[sct target] < 2} {
|
||||
if {[hvali [sct parent]/[sct @motname]/encoder] > 20} {
|
||||
[sct @motname] maxspeed 200
|
||||
sctsync {
|
||||
run [sct @motname] 15
|
||||
}
|
||||
}
|
||||
set val 1
|
||||
catch {
|
||||
# fix n.v.
|
||||
hsetprop /nv off_until [expr [DoubleTime] + 10]
|
||||
hsetprop /nv off_reason "pump valve closed"
|
||||
}
|
||||
sct update 1
|
||||
return hepump::slow_close
|
||||
} elseif {[sct target] < 4} {
|
||||
[sct @motname] maxspeed 200
|
||||
hset [sct parent]/[sct @motname] [hval [sct parent]/[sct @motname]/upperlimit]
|
||||
set val 2
|
||||
}
|
||||
sct update $val
|
||||
return idle
|
||||
}
|
||||
|
||||
proc hepump::slow_close {} {
|
||||
[sct @motname] maxspeed [sct slowspeed]
|
||||
sct slowspeed [expr max(10,[sct slowspeed] - 10)]
|
||||
run [sct @motname] [hval [sct parent]/[sct @motname]/lowerlimit]
|
||||
return idle
|
||||
}
|
||||
|
||||
proc hepump::get_valve {} {
|
||||
if {[sctval [sct parent]] != 0} {return idle}
|
||||
set p [sct parent]/[sct @motname]
|
||||
set stat [hgetpropval $p status]
|
||||
set pos [hvali $p/encoder]
|
||||
if {$pos < [hval $p/lowerlimit] - 15 ||
|
||||
$pos > [hval $p/upperlimit] + 15} {
|
||||
hsetprop $p/encoder adjust_zero 1
|
||||
return idle
|
||||
}
|
||||
set dir [string map {0 close 1 close 2 open 3 open 4 undefined} [silent 4 sct target]]
|
||||
if {[sct try] == 0} {
|
||||
set dir undefined
|
||||
}
|
||||
if {$stat eq "run"} {
|
||||
if {[hgetpropval $p target] > $pos} {
|
||||
sct update 2
|
||||
} else {
|
||||
sct update 1
|
||||
}
|
||||
} elseif {$pos < 2 && $dir ne "open"} {
|
||||
sct update 0 ;# closed
|
||||
sct try 0
|
||||
set_valve_status ""
|
||||
} elseif {$pos > 30 && $dir ne "close"} {
|
||||
sct update 3 ;# opened
|
||||
sct try 0
|
||||
set_valve_status ""
|
||||
} else {
|
||||
if {[sct try] > 1 && $dir ne "undefined"} {
|
||||
set try [sct try]
|
||||
incr try -1
|
||||
if {$try <= 3} {
|
||||
clientput "[sct] try again to $dir ($try)"
|
||||
}
|
||||
hset [sct] [sct target]
|
||||
sct try $try
|
||||
} else {
|
||||
sct try 0
|
||||
if {$dir ne "undefined"} {
|
||||
set txt "cannot $dir valve at He pump. Please do it manually"
|
||||
clientput "ERROR: $txt"
|
||||
set_valve_status $txt
|
||||
sct target 4
|
||||
}
|
||||
sct update 4 ;# undefined
|
||||
}
|
||||
}
|
||||
if {[hvali [sct]] != 3} {
|
||||
# not open - fix n.v.
|
||||
catch {
|
||||
hsetprop /nv off_until [expr [DoubleTime] + 10]
|
||||
hsetprop /nv off_reason "pump valve closed"
|
||||
}
|
||||
}
|
||||
return idle
|
||||
}
|
||||
|
||||
proc hepump::chk_running {} {
|
||||
if {[sctval [sct parent]] != 0} return
|
||||
if {[sct target]} {
|
||||
hset [sct parent]/[sct @motname]/output0 1
|
||||
} else { # off
|
||||
if {[silent 0 result instconfig he_pump_type] ne "other_pump_with_valve"} {
|
||||
# fix n.v.
|
||||
catch {
|
||||
hsetprop /nv off_until [expr [DoubleTime] + 10]
|
||||
hsetprop /nv off_reason "He pump not running"
|
||||
}
|
||||
hset [sct parent]/[sct @motname]/output0 0
|
||||
}
|
||||
}
|
||||
hsetprop [sct parent]/[sct @motname]/output0 trigger_path [sct parent]/[sct @motname]/input3
|
||||
sct update [sct target]
|
||||
}
|
||||
|
||||
proc hepump::get_running {} {
|
||||
# only for xds35
|
||||
if {[sctval [sct parent]] != 0} {return idle}
|
||||
|
||||
set running [sctval [sct parent]/[sct @motname]/output0]
|
||||
set pumpoff [silent 1 hval [sct parent]/[sct @motname]/input3]
|
||||
set now [DoubleTime]
|
||||
if {$running != [silent 0 sct last_running]} {
|
||||
sct last_running $running
|
||||
# leave early (status should be checked later, when input3 is read again)
|
||||
return idle
|
||||
}
|
||||
sct update $running
|
||||
if {$now < [silent 0 sct last_ok] + 30} {
|
||||
return idle
|
||||
}
|
||||
set old [hvali [sct parent]/status]
|
||||
set new ""
|
||||
if {$running} {
|
||||
if {$pumpoff} {
|
||||
if {[silent 0 result instconfig he_pump_type] ne "other_pump_with_valve"} {
|
||||
set new "He pump remote cable is not connected"
|
||||
catch {hsetprop /nv off_until [expr $now + 10]}
|
||||
}
|
||||
} else {
|
||||
sct last_ok [DoubleTime]
|
||||
}
|
||||
} else {
|
||||
if {!$pumpoff} {
|
||||
set new "He pump is still running - manual power must be switched off"
|
||||
} else {
|
||||
sct last_ok [DoubleTime]
|
||||
}
|
||||
catch {
|
||||
hsetprop /nv off_until [expr $now + 10]
|
||||
hsetprop /nv off_reason "He pump not running"
|
||||
}
|
||||
}
|
||||
if {$new ne $old} {
|
||||
if {$new ne ""} {
|
||||
clientput "ERROR: $new"
|
||||
}
|
||||
hupdate [sct parent]/status $new
|
||||
}
|
||||
return idle
|
||||
}
|
||||
|
||||
proc hepump::set_eco {} {
|
||||
if {[sctval [sct parent]] != 0} {return idle}
|
||||
if {[sct target] != [hvali [sct]]} {
|
||||
hset [sct parent]/auto 0
|
||||
}
|
||||
if {[sct target]} {
|
||||
hset [sct parent]/[sct @motname]/output1 1
|
||||
} else { # eco off
|
||||
hset [sct parent]/[sct @motname]/output1 0
|
||||
}
|
||||
hepump::get_eco
|
||||
}
|
||||
|
||||
proc hepump::get_eco {} {
|
||||
if {[sctval [sct parent]] != 0} {return idle}
|
||||
set eco [sctval [sct parent]/[sct @motname]/output1]
|
||||
sct update $eco
|
||||
[sct controller] queue [sct parent] write hepump::set_calib
|
||||
return idle
|
||||
}
|
||||
|
||||
proc hepump::set_auto {} {
|
||||
if {[sctval [sct parent]] != 0} {return idle}
|
||||
sct update [sct target]
|
||||
}
|
||||
|
||||
proc hepump::get_auto {} {
|
||||
if {[sctval [sct parent]] != 0} {return idle}
|
||||
set auto [hvali [sct]]
|
||||
set oldeco [sctval [sct parent]/eco]
|
||||
if {$auto && $oldeco != 2} {
|
||||
set eco [sctval [sct parent]/eco]
|
||||
set lim [sctval [sct parent]/eco_t_lim 7]
|
||||
if {[silent 10 hval /tt/target] < $lim && [silent 10 hval /tt] < 2 * $lim} {
|
||||
set ecoset 0
|
||||
} elseif {[silent 10 hval /tt/target] > $lim || [silent 10 hval /tt] > 3 * $lim} {
|
||||
set ecoset 1
|
||||
} else {
|
||||
set ecoset $eco
|
||||
}
|
||||
if {$oldeco != $ecoset} {
|
||||
hset [sct parent]/eco $ecoset
|
||||
}
|
||||
}
|
||||
sct update $auto
|
||||
return idle
|
||||
}
|
||||
|
Reference in New Issue