diff --git a/addons/ah2700leiden_cfg.py b/addons/ah2700leiden_cfg.py
new file mode 100644
index 0000000..fba5a73
--- /dev/null
+++ b/addons/ah2700leiden_cfg.py
@@ -0,0 +1,20 @@
+Node('ah2700.frappy.psi.ch',
+ 'Andeen Hagerlin 2700 Capacitance Bridge',
+)
+
+Mod('cap_io',
+ 'frappy_psi.ah2700.Ah2700IO',
+ '',
+ uri='linse-leiden-ts:3002',
+ timeout=60,
+)
+
+# this creates also cap_freq and cap_loss
+Mod('cap',
+ 'frappy_psi.ah2700.Capacitance',
+ 'capacitance',
+ io = 'cap_io',
+ loss_name='loss',
+ freq_name='freq',
+)
+
diff --git a/addons/ahtwo_cfg.py b/addons/ahtwo_cfg.py
new file mode 100644
index 0000000..d3c40cb
--- /dev/null
+++ b/addons/ahtwo_cfg.py
@@ -0,0 +1,39 @@
+Node('ahtwo.frappy.psi.ch',
+ 'Andeen Hagerlin 2700 and 2550 Capacitance Bridges',
+)
+
+# TODO: adapt names (cap, cap2) to your experiment
+
+Mod('cap_io',
+ 'frappy_psi.ahcapbridge.IO', '',
+ uri='linse-leiden-ts:3002'
+)
+
+Mod('cap',
+ 'frappy_psi.ahcapbridge.AH2700',
+ 'capacitance',
+ acquisition_key='averexp',
+ io='cap_io',
+ loss_module = 'loss',
+ freq_module = 'freq',
+)
+
+Mod('capvolt',
+ 'frappy_psi.ahcapbridge.Voltage',
+ 'excitation voltage',
+ cap = 'cap',
+)
+
+Mod('cap2_io',
+ 'frappy_psi.ahcapbridge.IO', '',
+ uri='linse-leiden-ts:3001'
+)
+
+Mod('cap2',
+ 'frappy_psi.ahcapbridge.AH2550',
+ 'capacitance',
+ acquisition_key='averexp',
+ io='cap2_io',
+ loss_module = 'loss2',
+)
+
diff --git a/addons/flamesample2_cfg.py b/addons/flamesample2_cfg.py
new file mode 100644
index 0000000..63317c0
--- /dev/null
+++ b/addons/flamesample2_cfg.py
@@ -0,0 +1,55 @@
+Node('flamesample2.psi.ch',
+ 'flame sample low and high thermometers and heater',
+ interface = 'tcp://5000',
+)
+
+Mod('lscio',
+ 'frappy_psi.ls372.StringIO',
+ 'sample channels LS372 io',
+ uri = 'flamedil-ls.psi.ch:7777',
+)
+
+Mod('lsc_channel',
+ 'frappy_psi.ls372.Switcher',
+ 'channel switcher sample ls372',
+ io='lscio',
+ value = 3,
+)
+
+Mod('ts_low',
+ 'frappy_psi.ls372.TemperatureLoop',
+ 'sample RuOX',
+ channel = 3,
+ switcher = 'lsc_channel',
+ minrange=13,
+ range=22,
+ tolerance = 0.1,
+ vexc = 3,
+ htrrng=4,
+)
+
+Mod('ts_high',
+ 'frappy_psi.ls372.TemperatureLoop',
+ 'sample Cernox',
+ channel = 1,
+ switcher = 'lsc_channel',
+ minrange=11,
+ vexc = 5,
+ range=22,
+ tolerance = 0.1,
+ htrrng=5,
+ minheater=5e-4,
+)
+
+Mod('ts',
+ 'frappy_psi.parmod.SwitchDriv',
+ 'automatically switching between ts_low and ts_high',
+ value=Param(unit='K'),
+ low='ts_low',
+ high='ts_high',
+ #min_high=0.6035,
+ #max_low=1.6965,
+ min_high=0.6,
+ max_low=1.7,
+ tolerance=0.1,
+)
diff --git a/addons/haake_add_cfg.py b/addons/haake_add_cfg.py
new file mode 100644
index 0000000..c18905f
--- /dev/null
+++ b/addons/haake_add_cfg.py
@@ -0,0 +1,15 @@
+Node('haake.frappy.psi.ch',
+ 'additional haake waterbath',
+)
+
+Mod('haake_io',
+ 'frappy_psi.haake.HaakeIO',
+ '',
+ uri='sans-sample-ts:3006',
+)
+
+Mod('T2',
+ 'frappy_psi.haake.TemperatureLoop',
+ 'second haake',
+ io = 'haake_io',
+)
diff --git a/addons/laser_cfg.py b/addons/laser_cfg.py
new file mode 100644
index 0000000..e6af042
--- /dev/null
+++ b/addons/laser_cfg.py
@@ -0,0 +1,22 @@
+Node('pdld_laser.psi.ch',
+ 'PDLD laser',
+ interface = 'tcp://5000',
+)
+
+Mod('laser_io',
+ 'frappy_psi.pdld.IO',
+ 'laser IO',
+ uri='serial:///dev/ttyUSB0?baudrate=9600',
+)
+
+Mod('laser',
+ 'frappy_psi.pdld.Laser',
+ 'laser switch',
+ io='laser_io',
+)
+
+Mod('laser_power',
+ 'frappy_psi.pdld.LaserPower',
+ 'laser power',
+ io='laser_io',
+)
diff --git a/addons/leidenexp_cfg.py b/addons/leidenexp_cfg.py
new file mode 100644
index 0000000..e479c42
--- /dev/null
+++ b/addons/leidenexp_cfg.py
@@ -0,0 +1,244 @@
+Node('leidenexp.psi.ch',
+ '''Leiden Dilution''',
+)
+
+#ah2550_uri = 'linse-leiden-ts:3001' # capacitance bridge AH 2550
+ah2700_uri = 'linse-leiden-ts:3002' # capacitance bridge AH 2700
+sourcemeter_uri = 'linse-leiden-ts:3001' # k2601b used for HC experiment as heater
+srbridge_uri = 'linse-leiden-ts:3008' # Stanford Research Resistance Bridge
+calib_uri = 'linse-leiden-ts:3006'
+# ls370 on port 3004: see ~/sea/tcl/leiden.config
+
+sea_cfg = 'leidenexp.addon'
+
+Mod('sea_main',
+ 'frappy_psi.sea.SeaClient',
+ 'main sea connection for leiden.config',
+ config = 'leiden.config',
+ service = 'main',
+)
+
+for name in ['T3K', 'Tstill', 'T50mK', 'Tmxhigh',
+ 'Tpt50', 'Tpt3high', 'Tpt3low']:
+ mname = name.replace('T','T_')
+ kwds = {}
+ if name == 'Tmxlow':
+ kwds['meaning'] = ['temperature', 20]
+ Mod(mname,
+ 'frappy_psi.sea.SeaReadable', '',
+ io='sea_main',
+ sea_object='tt',
+ rel_paths=[name],
+ value=Param(unit='K'),
+ extra_modules = ['raw'],
+ **kwds
+ )
+ Mod(name.replace('T', 'R_'),
+ 'frappy_psi.sea.SeaReadable', '',
+ io='sea_main',
+ value=Param(unit='Ohm'),
+ single_module=f'{mname}.raw'
+ )
+
+# "if not
" means disabled, "if " means enabled
+
+if 'calibsetup':
+ IO('io_cal', leiden_uri)
+
+ Mod('V_cmn',
+ 'frappy_psi.lakeshore340.RawSensor',
+ 'voltage for cmn',
+ io = 'io_cal',
+ value = Param(unit='V'),
+ channel = 'B'
+ )
+
+ Mod('T_cmn',
+ 'frappy_psi.softcal.Function',
+ '',
+ value=Param(unit='K'),
+ rawsensor='V_cmn'
+ formula='0.85e-3 + 16.33005 / (1000 * x - 60.83)'
+ )
+
+ Mod('V_fixp',
+ 'frappy_psi.lakeshore340.RawSensor',
+ 'voltage for fixp',
+ io = 'io_cal',
+ value = Param(unit='V'),
+ channel = 'A'
+ )
+
+ Mod('io_mixhtr',
+ 'frappy.core.Proxy',
+ 'proxy to main frappy server',
+ remote_class = 'frappy_psi.dilhtr.IO',
+ uri = f'tcp://localhost:15118',
+ module='io_htr',
+ )
+
+ Mod('mix_htr4cmn',
+ 'frappy_psi.dilhtr.WrappedHeater',
+ 'mix heater',
+ io='io_mixhtr',
+ )
+
+ Mod('drive_cmn',
+ 'frappy_psi.picontrol.PIctrl',
+ 'controlled cmn temperature',
+ input_module = 'T_cmn',
+ output_module = 'mix_htr4cmn',
+ output_min = 0,
+ output_max = 3e-2,
+ p = 2,
+ itime = 120,
+ )
+
+ #Mod('drive_fixp',
+ # 'frappy_psi.picontrol.PI',
+ # 'controlled fixpoint voltage',
+ # value=Param(unit='V'),
+ # input_module = 'V_fixp',
+ # output_module = 'drive_mix',
+ # output_min = 0.0,
+ # output_max = 0.01,
+ # p = 1,
+ # itime = 120,
+ #)
+
+if 'sr_bridge':
+ IO('io_sr', srbridge_uri)
+
+ Mod('res1',
+ 'frappy_psi.bridge.Resistance',
+ 'please add description',
+ io='io_sr',
+ port=1,
+ )
+
+ Mod('T_res1',
+ 'frappy_psi.softcal.Sensor',
+ '',
+ rawsensor='res1',
+ calcurve='RCW575a',
+ )
+
+ Mod('res2',
+ 'frappy_psi.bridge.Resistance',
+ 'please add description',
+ io='io_sr',
+ port=3,
+ )
+
+ Mod('T_res2',
+ 'frappy_psi.softcal.Sensor',
+ '',
+ rawsensor='res2',
+ calcurve='RC550a',
+ )
+
+ Mod('phase1',
+ 'frappy_psi.bridge.Phase',
+ 'please add description',
+ resistance='res1',
+ )
+
+ Mod('phase2',
+ 'frappy_psi.bridge.Phase',
+ 'please add description',
+ resistance='res2',
+ )
+
+ Mod('dev1',
+ 'frappy_psi.bridge.Deviation',
+ 'please add description',
+ resistance='res1',
+ )
+
+ Mod('dev2',
+ 'frappy_psi.bridge.Deviation',
+ 'please add description',
+ resistance='res2',
+ )
+
+
+if 'keihley 2601b':
+ IO('io_sm', sourcemeter_uri)
+
+ Mod('source',
+ 'frappy_psi.k2601b.SourceMeter'
+ '',
+ description = "keithley sourcemeter",
+ mode = 2,
+ vlimit = 0.5,
+ ilimit = .0005,
+ io = 'io_sm',
+ )
+
+ Mod('hvolt',
+ 'frappy_psi.k2601b.Voltage'
+ '',
+ description = "Heater Voltage",
+ active = False,
+ limit = 1.0,
+ target = 0.0,
+ sourcemeter = 'source',
+ io = 'io_sm',
+ )
+
+ Mod('hcur',
+ 'frappy_psi.k2601b.Current'
+ '',
+ description = "Heater Current Source",
+ active = True,
+ limit = 0.0001,
+ target = 0.0,
+ sourcemeter = 'source',
+ io = 'io_sm',
+ )
+
+ Mod('hres',
+ 'frappy_psi.k2601b.Resistivity'
+ '',
+ description = "Heater Resistance",
+ io = 'io_sm',
+ )
+
+ Mod('hpow',
+ 'frappy_psi.k2601b.Power'
+ '',
+ description = "Heater Power",
+ io = 'io_sm',
+ )
+
+
+if 'cap ah2700':
+ # TODO: adapt names (cap...) to your experiment
+
+ IO('io_ah2700', ah2700_uri)
+
+ Mod('cap',
+ 'frappy_psi.ahcapbridge.AH2700',
+ 'capacitance',
+ acquisition_key='averexp',
+ io='io_ah2700',
+ loss_module = 'loss',
+ freq_module = 'freq',
+ )
+
+ Mod('capvolt',
+ 'frappy_psi.ahcapbridge.Voltage',
+ 'excitation voltage',
+ cap = 'cap',
+ )
+
+if not 'cap_ah2550':
+ IO('io_ah2550', ah2550_uri)
+
+ Mod('cap2',
+ 'frappy_psi.ahcapbridge.AH2550',
+ 'capacitance',
+ acquisition_key='averexp',
+ io='io_ah2550',
+ loss_module = 'loss2',
+ )
diff --git a/main/leiden_cfg.py b/main/leiden_cfg.py
new file mode 100644
index 0000000..16dc0d4
--- /dev/null
+++ b/main/leiden_cfg.py
@@ -0,0 +1,135 @@
+Node('leiden.psi.ch',
+ 'Leiden Dilution, basic config',
+ 'tcp://5000',
+ secondary = ['ws://8051']
+)
+
+IO('io_tcs', 'linse-leiden-ts:3005')
+IO('io_htr', 'linse-leiden-ts:3007')
+IO('io_ghs', 'linse-521e-ts:3001')
+IO('io_pfeiffer', 'linse-521e-ts:3002')
+IO('io_ccr', 'linse-521e-ts:3003')
+
+# ah2700: linse-leiden-ts:3002, see leidenexp_cfg.py)
+# ls370: 'linse-leiden-ts:3004, see ~/sea/tcl/leiden.config
+# nanovolt: linse-leiden-ts:3006, see ~/sea/tcl/leiden.config
+# k2601b: linse-leiden-ts:3006, see leidenexp_cfg.py ( used for HC experiment as heater)
+# SR bridge: linse-leiden-ts:3008, see leidenexp_cfg.py
+
+Mod('sea_conn', # do not use sea_main, as this is used in addons/leidenexp_cfg.py
+ 'frappy_psi.sea.SeaClient',
+ 'main sea connection for leiden.config',
+ config = 'leiden.config',
+ service = 'main',
+ uri = 'localhost:8648', # for prep8. TODO: check why this is not taken automatically
+)
+
+Mod('T_mix',
+ 'frappy_psi.sea.SeaReadable', '',
+ io='sea_conn',
+ sea_object='tt',
+ rel_paths=['Tmix'],
+ value=Param(unit='K'),
+ extra_modules = ['raw'],
+ meaning = ['temperature', 20],
+)
+
+Mod('R_mix',
+ 'frappy_psi.sea.SeaReadable', '',
+ io='sea_conn',
+ value=Param(unit='Ohm'),
+ single_module='T_mix.raw'
+)
+
+Mod('still_htr',
+ 'frappy_psi.tcs.Heater',
+ 'still heater',
+ io='io_tcs',
+ channel=2,
+ )
+
+Mod('mix_htr',
+ 'frappy_psi.dilhtr.WrappedHeater',
+ 'mixing chamber heater',
+ io='io_htr',
+ )
+
+Mod('drive_mix',
+ 'frappy_psi.picontrol.PIctrl',
+ 'controlled mix ch. temperature',
+ input_module = 'T_mix',
+ output_module = 'mix_htr',
+ output_min = 0,
+ output_max = 0.02,
+ p = 5,
+ itime = 60,
+ )
+
+for name in [
+ 'A0', 'A1', 'A10', 'A2', 'A3', 'A4', 'A5', 'A6', 'A7', 'A8', 'A9',
+ 'AUX1', 'He3', 'He4', 'S1', 'S2', 'S3', 'S4', 'S5',
+ 'V0', 'V1', 'V2', 'V3', 'V4', 'V5', 'V6', 'V7', 'V8', 'V9',
+ 'V10', 'V11', 'V12', 'V13', 'V14', 'V15', 'V16', 'V17',
+ 'auto', 'bypass', 'circulation', 'gate18', 'ledtest', 'mixcompr', 'recovery', 'reset', 'start']:
+ Mod(name,
+ 'frappy_psi.leidenghs.Valve',
+ f'switch or valve {name}',
+ io='io_ghs',
+ key=name,
+ )
+
+Mod('p0',
+ 'frappy_psi.leidenghs.Pressure',
+ 'test pressure p0',
+ io='io_ghs',
+ addr='p0',
+ scale=2**12 / 1e4,
+ )
+
+for pname in ['p2', 'p3', 'p4', 'p5']:
+ Mod(pname,
+ 'frappy_psi.leidenghs.Pressure',
+ 'pressure {pname}',
+ io='io_ghs',
+ addr=pname,
+ )
+
+Mod('p6',
+ 'frappy_psi.leidenghs.PressureLimit',
+ 'test pressure with limits p6',
+ io='io_ghs',
+ addr='p6',
+ offset=0,
+ )
+
+Mod('p7',
+ 'frappy_psi.leidenghs.PressureLimit',
+ 'test pressure with limits p7',
+ io='io_ghs',
+ addr='p7',
+ offset=0,
+ )
+
+Mod('flow',
+ 'frappy_psi.leidenghs.PressureLimit',
+ 'condense flow',
+ io='io_ghs',
+ addr='flow',
+ offset=0,
+ value=Param(unit='ln/min'),
+ scale = 2**15 / 1e2,
+ )
+
+for pname, addr in [('p8', 4), ('p9', 3), ('p10', 2)]:
+ Mod(pname,
+ 'frappy_psi.pfeiffer.Pressure',
+ f'pressure reading {pname}',
+ io = 'io_pfeiffer',
+ channel = addr,
+ )
+
+#Mod('ccr_compressor',
+# 'frappy_psi.cp2800.CP2800',
+# 'cryocooler compressor',
+# io='io_ccr',
+#)
diff --git a/main/leidenghs_cfg.py b/main/leidenghs_cfg.py
new file mode 100644
index 0000000..2ea9e17
--- /dev/null
+++ b/main/leidenghs_cfg.py
@@ -0,0 +1,85 @@
+Node('leidenghs_test.test',
+ 'test leiden GHS driver',
+ 'tcp://5000',
+ )
+
+Mod('io',
+ 'frappy_psi.leidenghs.IO',
+ 'leiden GHS communication',
+ uri='linse-521e-ts:3001',
+ )
+
+for valve in {'mix': 1, # mixture compressor
+ 'bypass': 2,
+ '15': 3,
+ '16': 4,
+ 'gate18': 6,
+ '4': 7,
+ '5': 9,
+ 'reset': 10,
+ '9': 12,
+ '14': 13,
+ '13': 15,
+ 'ledtest': 16,
+ '12': 18,
+ '10': 19,
+ '11': 21,
+ 'A0': 22,
+ '7': 24,
+ 'S3': 25,
+ '6': 27,
+ '17': 28,
+ '8': 30,
+ '1': 31,
+ 'S2': 33,
+ '3': 34,
+ '2': 36,
+ '0': 37,
+ 'S1': 39,
+ 'A9': 40,
+ 'A8': 42,
+ 'A2': 43,
+ 'S5': 45,
+ 'A10': 46,
+ 'start': 48,
+ 'A5': 49,
+ 'A7': 51,
+ 'auto': 54,
+ 'A4': 55,
+ 'A6': 57,
+ 'S4': 58,
+ 'A3': 60,
+ 'He3': 61, # condense He3
+ 'He4': 62, # condense He4
+ 'circulation': 63, # normal circulation
+ 'recovery': 64,
+ }:
+ name = 'n' + valve if valve.isdecimal() else valve
+ Mod(name,
+ 'frappy_psi.leidenghs.Valve',
+ f'test valve {valve}',
+ io='io',
+ key=valve,
+ )
+
+Mod('P1',
+ 'frappy_psi.leidenghs.Pressure',
+ 'test pressure P1',
+ io='io',
+ addr='P1',
+ )
+
+Mod('P2',
+ 'frappy_psi.leidenghs.Pressure',
+ 'test pressure P2',
+ io='io',
+ addr='P2',
+ )
+
+Mod('P6',
+ 'frappy_psi.leidenghs.PressureLimit',
+ 'test pressure with limits P6',
+ io='io',
+ addr='P6',
+ offset=0,
+ )
diff --git a/main/tfa_cfg.py b/main/tfa_cfg.py
new file mode 100644
index 0000000..236d6c7
--- /dev/null
+++ b/main/tfa_cfg.py
@@ -0,0 +1,20 @@
+Node('TFA10.psi.ch',
+ 'thermofisher water bath',
+ 'tcp://5000',
+ )
+
+Mod('io',
+ 'frappy_psi.thermofisher.ThermFishIO',
+ 'connection for ThermoFisher A10',
+ uri='tcp://ldm-fi-ts:3002',
+ )
+
+Mod('T',
+ 'frappy_psi.thermofisher.TemperatureLoopA10',
+ 'holder temperature',
+ io='io',
+ meaning=['temperature', 20],
+ target=Param(max=100),
+ tolerance=0.5,
+ settling_time=20,
+ )
diff --git a/sea/cp1000_cfg.py b/sea/cp1000_cfg.py
new file mode 100644
index 0000000..610331c
--- /dev/null
+++ b/sea/cp1000_cfg.py
@@ -0,0 +1,14 @@
+Node('cp1000.addon.sea.psi.ch',
+ '''dry system''',
+)
+Mod('sea_addons',
+ 'frappy_psi.sea.SeaClient',
+ 'addons sea connection for cp1000.addon',
+ config = 'cp1000.addon',
+ service = 'addons',
+)
+Mod('cp2800',
+ 'frappy_psi.sea.SeaWritable', '',
+ io = 'sea_addons',
+ sea_object = 'cp2800',
+)
diff --git a/stick/fibrestick_cfg.py b/stick/fibrestick_cfg.py
new file mode 100644
index 0000000..598c55e
--- /dev/null
+++ b/stick/fibrestick_cfg.py
@@ -0,0 +1,37 @@
+Node('fibrestick.psi.ch',
+ 'stick with laser fibre',
+)
+
+Mod('sea_stick',
+ 'frappy_psi.sea.SeaClient',
+ 'SEA stick connection',
+ config='fibre.stick',
+ service='stick',
+)
+
+Mod('ts',
+ 'frappy_psi.sea.SeaReadable', '',
+ meaning=['temperature', 30],
+ io='sea_stick',
+ sea_object='tt',
+ json_file='ma11.config.json',
+ rel_paths=['ts'],
+)
+
+Mod('laser_io',
+ 'frappy_psi.pdld.IO',
+ 'laser IO',
+ uri='serial:///dev/serial/by-path/pci-0000:00:14.0-usb-0:4.4.4.2:1.0-port0?baudrate=9600',
+)
+
+Mod('laser',
+ 'frappy_psi.pdld.Laser',
+ 'laser switch',
+ io='laser_io',
+)
+
+Mod('laser_power',
+ 'frappy_psi.pdld.LaserPower',
+ 'laser power',
+ io='laser_io',
+)
diff --git a/stick/msparestick_cfg.py b/stick/msparestick_cfg.py
new file mode 100644
index 0000000..4e2a3d2
--- /dev/null
+++ b/stick/msparestick_cfg.py
@@ -0,0 +1,34 @@
+Node('mspare.stick.sea.psi.ch',
+ 'MA generic sample stick',
+)
+
+Mod('sea_stick',
+ 'frappy_psi.sea.SeaClient',
+ 'SEA stick connection',
+ config='mspare.stick',
+ service='stick',
+)
+
+Mod('ts',
+ 'frappy_psi.sea.SeaReadable',
+ 'sample stick temperature',
+ io='sea_stick',
+ json_file='ma6.config.json',
+ sea_object='tt',
+ rel_paths=['ts', 'setsamp'],
+ meaning=['temperature', 30],
+)
+
+
+"""
+Mod('ts',
+ 'frappy_psi.parmod.Converging',
+ 'drivable stick T using setsamp',
+ meaning=['temperature', 25],
+ unit='K',
+ read='tsam.value',
+ write='tsam.setsamp',
+ settling_time=20,
+ tolerance=1,
+)
+"""