[equipment MLZ_amagnet(Garfield)]
description=MLZ-Amagnet
.
Water cooled magnet from ANTARES@MLZ.
.
Use module to control the magnetic field.
Don't forget to select symmetry first (can be moved only at zero field!).
.
Monitor T1..T4 (Coil temps), if they get to hot, field will ramp down!
.
In case of Problems, contact the ANTARES people at MLZ.
visibility=expert
foo=bar
[interface tcp]
interface=tcp
bindto=0.0.0.0
bindport=10767
# protocol to use for this interface
framing=eol
encoding=secop
[device enable]
class=secop_mlz.entangle.NamedDigitalOutput
tangodevice='tango://amagnet.antares.frm2:10000/box/plc/_enable'
value.datatype=["enum", {'On':1,'Off':0}]
target.datatype=["enum", {'On':1,'Off':0}]
.description='Enables to Output of the Powersupply'
.visibility='advanced'
[device polarity]
class=secop_mlz.entangle.NamedDigitalOutput
tangodevice=tango://amagnet.antares.frm2:10000/box/plc/_polarity
value.datatype=["enum", {'+1':1,'0':0,'-1':-1}]
target.datatype=["enum", {'+1':1,'0':0,'-1':-1}]
.description=polarity (+/-) switch
.
there is an interlock in the plc:
if there is current, switching polarity is forbidden
if polarity is short, powersupply is disabled
.visibility=advanced
comtries=50
[device symmetry]
class=secop_mlz.entangle.NamedDigitalOutput
tangodevice=tango://amagnet.antares.frm2:10000/box/plc/_symmetric
value.datatype=["enum",{'symmetric':1,'short':0, 'asymmetric':-1}]
target.datatype=["enum",{'symmetric':1,'short':0, 'asymmetric':-1}]
.description=par/ser switch selecting (a)symmetric mode
.
symmetric is ser, asymmetric is par
.visibility=advanced
[device T1]
class=secop_mlz.entangle.AnalogInput
tangodevice=tango://amagnet.antares.frm2:10000/box/plc/_t1
.description=Temperature1 of the coils system
#warnlimits=(0, 50)
value.unit='degC'
[device T2]
class=secop_mlz.entangle.AnalogInput
tangodevice=tango://amagnet.antares.frm2:10000/box/plc/_t2
.description=Temperature2 of the coils system
#warnlimits=(0, 50)
value.unit='degC'
[device T3]
class=secop_mlz.entangle.AnalogInput
tangodevice=tango://amagnet.antares.frm2:10000/box/plc/_t3
.description=Temperature3 of the coils system
#warnlimits=(0, 50)
value.unit='degC'
[device T4]
class=secop_mlz.entangle.AnalogInput
tangodevice=tango://amagnet.antares.frm2:10000/box/plc/_t4
.description=Temperature4 of the coils system
#warnlimits=(0, 50)
value.unit='degC'
[device currentsource]
class=secop_mlz.entangle.PowerSupply
tangodevice=tango://amagnet.antares.frm2:10000/box/lambda/curr
.description=Device for the magnet power supply (current mode)
abslimits=(0,200)
speed=1
ramp=60
precision=0.02
current=0
voltage=10
#unit=A
.visibility=advanced
[device mf]
class=secop_mlz.amagnet.GarfieldMagnet
.description=magnetic field device, handling polarity switching and stuff
subdev_currentsource=currentsource
subdev_enable=enable
subdev_polswitch=polarity
subdev_symmetry=symmetry
target.unit='T'
value.unit='T'
userlimits=(-0.35, 0.35)
calibrationtable={'symmetric':[0.00186517, 0.0431937, -0.185956, 0.0599757, 0.194042],
'short': [0.0, 0.0, 0.0, 0.0, 0.0],
'asymmetric':[0.00136154, 0.027454, -0.120951, 0.0495289, 0.110689]}
.meaning=The magnetic field
.priority=100
.visibility=user
abslimits.default=-0.4,0.4