frappy/secop_psi/magfield.py
l_samenv 766f15beee improvements in magfield
- use HasTargetLimits instead of HasLimits
- move ramp_tmo parameter to SompleMagfield
- add last_target method
- fix progress check in SimpleMagfield.ramp_to_target
- better mechanism for setting to persistent mode after restart
- fix switching mode
- fix on_error
- fix condition for shortcut start_field_change -> check_switch_off
- remove direct status updates
- move check for manual switch heater operations to ips_mercury
2022-12-21 10:57:41 +01:00

382 lines
14 KiB
Python

# -*- coding: utf-8 -*-
# *****************************************************************************
# This program is free software; you can redistribute it and/or modify it under
# the terms of the GNU General Public License as published by the Free Software
# Foundation; either version 2 of the License, or (at your option) any later
# version.
#
# This program is distributed in the hope that it will be useful, but WITHOUT
# ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS
# FOR A PARTICULAR PURPOSE. See the GNU General Public License for more
# details.
#
# You should have received a copy of the GNU General Public License along with
# this program; if not, write to the Free Software Foundation, Inc.,
# 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA
#
# Module authors:
# Markus Zolliker <markus.zolliker@psi.ch>
# *****************************************************************************
"""generic persistent magnet driver"""
import time
from secop.core import Drivable, Parameter, Done, IDLE, BUSY, ERROR
from secop.datatypes import FloatRange, EnumType, ArrayOf, TupleOf, StatusType
from secop.features import HasTargetLimits
from secop.errors import ConfigError, ProgrammingError, HardwareError, BadValueError
from secop.lib.enum import Enum
from secop.states import Retry, HasStates, status_code, Start
UNLIMITED = FloatRange()
Mode = Enum(
DISABLED=0,
PERSISTENT=30,
DRIVEN=50,
)
Status = Enum(
Drivable.Status,
PREPARED=150,
PREPARING=340,
RAMPING=370,
STABILIZING=380,
FINALIZING=390,
)
OFF = 0
ON = 1
class SimpleMagfield(HasStates, HasTargetLimits, Drivable):
value = Parameter('magnetic field', datatype=FloatRange(unit='T'))
ramp = Parameter(
'wanted ramp rate for field', FloatRange(unit='$/min'), readonly=False)
# export only when different from ramp:
workingramp = Parameter(
'effective ramp rate for field', FloatRange(unit='$/min'), export=False)
tolerance = Parameter(
'tolerance', FloatRange(0, unit='$'), readonly=False, default=0.0002)
trained = Parameter(
'trained field (positive)',
TupleOf(FloatRange(-99, 0, unit='$'), FloatRange(0, unit='$')),
readonly=False, default=(0, 0))
wait_stable_field = Parameter(
'wait time to ensure field is stable', FloatRange(0, unit='s'), readonly=False, default=31)
ramp_tmo = Parameter(
'timeout for field ramp progress',
FloatRange(0, unit='s'), readonly=False, default=30)
_last_target = None
def checkProperties(self):
dt = self.parameters['target'].datatype
max_ = dt.max
if max_ == UNLIMITED.max:
raise ConfigError('target.max not configured')
if dt.min == UNLIMITED.min: # not given: assume bipolar symmetric
dt.min = -max_
super().checkProperties()
def stop(self):
"""keep field at current value"""
# let the state machine do the needed steps to finish
self.write_target(self.value)
def last_target(self):
"""get best known last target
as long as the guessed last target is within tolerance
with repsect to the main value, it is used, as in general
it has better precision
"""
last = self._last_target
if last is None:
try:
last = self.setpoint # get read back from HW, if available
except Exception:
pass
if last is None or abs(last - self.value) > self.tolerance:
return self.value
return last
def write_target(self, target):
self.check_limits(target)
self.start_machine(self.start_field_change, target=target)
return target
def init_progress(self, sm, value):
sm.prev_point = sm.now, value
def get_progress(self, sm, value):
"""return the time passed for at least one tolerance step"""
t, v = sm.prev_point
dif = abs(v - value)
tdif = sm.now - t
if dif > self.tolerance:
sm.prev_point = sm.now, value
return tdif
@status_code(BUSY, 'start ramp to target')
def start_field_change(self, sm):
self.setFastPoll(True, 1.0)
return self.start_ramp_to_target
@status_code(BUSY, 'ramping field')
def ramp_to_target(self, sm):
if sm.init:
self.init_progress(sm, self.value)
# Remarks: assume there is a ramp limiting feature
if abs(self.value - sm.target) > self.tolerance:
if self.get_progress(sm, self.value) > self.ramp_tmo:
raise HardwareError('no progress')
sm.stabilize_start = None # force reset
return Retry
sm.stabilize_start = time.time()
return self.stabilize_field
@status_code(BUSY, 'stabilizing field')
def stabilize_field(self, sm):
if sm.now - sm.stabilize_start < self.wait_stable_field:
return Retry
return self.final_status()
def read_workingramp(self):
return self.ramp
class Magfield(SimpleMagfield):
status = Parameter(datatype=StatusType(Status))
mode = Parameter(
'persistent mode', EnumType(Mode), readonly=False, initwrite=False, default=Mode.PERSISTENT)
switch_heater = Parameter('switch heater', EnumType(off=OFF, on=ON),
readonly=False, default=0)
current = Parameter(
'leads current (in units of field)', FloatRange(unit='$'))
# TODO: time_to_target
# profile = Parameter(
# 'ramp limit table', ArrayOf(TupleOf(FloatRange(unit='$'), FloatRange(unit='$/min'))),
# readonly=False)
# profile_training = Parameter(
# 'ramp limit table when in training',
# ArrayOf(TupleOf(FloatRange(unit='$'), FloatRange(unit='$/min'))), readonly=False)
# TODO: the following parameters should be changed into properties after tests
wait_switch_on = Parameter(
'wait time to ensure switch is on', FloatRange(0, unit='s'), readonly=False, default=61)
wait_switch_off = Parameter(
'wait time to ensure switch is off', FloatRange(0, unit='s'), readonly=False, default=61)
wait_stable_leads = Parameter(
'wait time to ensure current is stable', FloatRange(0, unit='s'), readonly=False, default=6)
persistent_limit = Parameter(
'above this limit, lead currents are not driven to 0',
FloatRange(0, unit='$'), readonly=False, default=99)
leads_ramp_tmo = Parameter(
'timeout for leads ramp progress',
FloatRange(0, unit='s'), readonly=False, default=30)
init_persistency = True
switch_on_time = None
switch_off_time = None
def doPoll(self):
if self.init_persistency:
if self.read_switch_heater() and self.mode != Mode.DRIVEN:
self.start_machine(self.go_persistent_soon, mode=self.mode)
self.init_persistency = False
super().doPoll()
def initModule(self):
super().initModule()
self.registerCallbacks(self) # for update_switch_heater
def write_mode(self, value):
self.init_persistency = False
target = self.last_target()
func = self.start_field_change
if value == Mode.DISABLED:
target = 0
if abs(self.value) < self.tolerance:
func = self.start_switch_off
elif value == Mode.PERSISTENT:
func = self.start_switch_off
self.target = target
self.start_machine(func, target=target, mode=value)
return value
def write_target(self, target):
self.init_persistency = False
if self.mode == Mode.DISABLED:
if target == 0:
return 0
self.log.info('raise error %r', target)
raise BadValueError('disabled')
self.check_limits(target)
self.start_machine(self.start_field_change, target=target, mode=self.mode)
return target
def on_error(self, sm): # sm is short for statemachine
if self.switch_heater == ON:
self.read_value()
if sm.mode != Mode.DRIVEN:
self.log.warning('turn switch heater off')
self.write_switch_heater(OFF)
return super().on_error(sm)
@status_code(Status.WARN)
def go_persistent_soon(self, sm):
if sm.delta(60):
self.target = sm.target = self.last_target()
return self.start_field_change
return Retry
@status_code(Status.PREPARING)
def start_field_change(self, sm):
self.setFastPoll(True, 1.0)
if (sm.target == self.last_target() and
abs(sm.target - self.value) <= self.tolerance and
abs(self.current - self.value) < self.tolerance and
(self.mode != Mode.DRIVEN or self.switch_heater == ON)): # short cut
return self.check_switch_off
if self.switch_heater == ON:
return self.start_switch_on
return self.start_ramp_to_field
@status_code(Status.PREPARING)
def start_ramp_to_field(self, sm):
"""start ramping current to persistent field
initiate ramp to persistent field (with corresponding ramp rate)
the implementation should return ramp_to_field
"""
raise NotImplementedError
@status_code(Status.PREPARING, 'ramp leads to match field')
def ramp_to_field(self, sm):
if sm.init:
sm.stabilize_start = 0 # in case current is already at field
self.init_progress(sm, self.current)
dif = abs(self.current - self.value)
if dif > self.tolerance:
tdif = self.get_progress(sm, self.current)
if tdif > self.leads_ramp_tmo:
raise HardwareError('no progress')
sm.stabilize_start = None # force reset
return Retry
if sm.stabilize_start is None:
sm.stabilize_start = sm.now
return self.stabilize_current
@status_code(Status.PREPARING)
def stabilize_current(self, sm):
if sm.now - sm.stabilize_start < self.wait_stable_leads:
return Retry
return self.start_switch_on
def update_switch_heater(self, value):
"""is called whenever switch heater was changed"""
if value == 0:
if self.switch_off_time is None:
self.log.info('restart switch_off_time')
self.switch_off_time = time.time()
self.switch_on_time = None
else:
if self.switch_on_time is None:
self.log.info('restart switch_on_time')
self.switch_on_time = time.time()
self.switch_off_time = None
@status_code(Status.PREPARING)
def start_switch_on(self, sm):
if (sm.target == self.last_target() and
abs(sm.target - self.value) <= self.tolerance): # short cut
return self.check_switch_off
if self.read_switch_heater() == OFF:
try:
self.write_switch_heater(ON)
except Exception as e:
self.log.warning('write_switch_heater %r', e)
return Retry
return self.wait_for_switch_on
@status_code(Status.PREPARING)
def wait_for_switch_on(self, sm):
if sm.now - self.switch_on_time < self.wait_switch_on:
if sm.delta(10):
self.log.info('waited for %g sec', sm.now - self.switch_on_time)
return Retry
self._last_target = sm.target
return self.start_ramp_to_target
@status_code(Status.RAMPING)
def start_ramp_to_target(self, sm):
"""start ramping current to target field
initiate ramp to target
the implementation should return ramp_to_target
"""
raise NotImplementedError
@status_code(Status.RAMPING)
def ramp_to_target(self, sm):
dif = abs(self.value - sm.target)
if sm.init:
sm.stabilize_start = 0 # in case current is already at target
self.init_progress(sm, self.value)
if dif > self.tolerance:
sm.stabilize_start = sm.now
tdif = self.get_progress(sm, self.value)
if tdif > self.workingramp / self.tolerance * 60 + self.ramp_tmo:
self.log.warn('no progress')
raise HardwareError('no progress')
sm.stabilize_start = None
return Retry
if sm.stabilize_start is None:
sm.stabilize_start = sm.now
return self.stabilize_field
@status_code(Status.STABILIZING)
def stabilize_field(self, sm):
if sm.now < sm.stabilize_start + self.wait_stable_field:
return Retry
return self.check_switch_off
def check_switch_off(self, sm):
if sm.mode == Mode.DRIVEN:
return self.final_status(Status.PREPARED, 'driven')
return self.start_switch_off
@status_code(Status.FINALIZING)
def start_switch_off(self, sm):
if self.switch_heater == ON:
self.write_switch_heater(OFF)
return self.wait_for_switch_off
@status_code(Status.FINALIZING)
def wait_for_switch_off(self, sm):
if sm.now - self.switch_off_time < self.wait_switch_off:
return Retry
if abs(self.value) > self.persistent_limit:
return self.final_status(Status.IDLE, 'leads current at field, switch off')
return self.start_ramp_to_zero
@status_code(Status.FINALIZING)
def start_ramp_to_zero(self, sm):
"""start ramping current to zero
initiate ramp to zero (with corresponding ramp rate)
the implementation should return ramp_to_zero
"""
raise NotImplementedError
@status_code(Status.FINALIZING)
def ramp_to_zero(self, sm):
"""ramp field to zero"""
if sm.init:
self.init_progress(sm, self.current)
if abs(self.current) > self.tolerance:
if self.get_progress(sm, self.value) > self.leads_ramp_tmo:
raise HardwareError('no progress')
return Retry
if sm.mode == Mode.DISABLED and abs(self.value) < self.tolerance:
return self.final_status(Status.DISABLED, 'disabled')
return self.final_status(Status.IDLE, 'persistent mode')