sens=ruoxben1k unit=Ohm ! sensor format (mV,V,Ohm), log formats are choosen automatical$ !tlim=2 ! setpoint limit (automatic if omitted) type=Special ! sensor type (Special,Si,GaAlAs,Pt250,Pt500,Pt2500,RhFe,C,Cern$ form=loglog curv ! curve (sensor,temp/K) follows, must be ordered, but can be in$ 1009 310 1010 273 1020 125 1040 57 1060 36 1080 26 1101 20 1105 19 1107 18.5 1110 18 1112 17.5 1115 17 1118 16.5 1121 16 1124 15.5 1127 15 1131 14.5 1135 14 1139 13.5 1143 13 1148 12.5 1153 12 1159 11.5 1165 11 1171 10.5 1178 10 1186 9.5 1195 9 1205 8.5 1216 8 1229 7.5 1243 7 1259 6.5 1277 6 1299 5.5 1325 5 1356 4.5 1395 4 1444 3.5 1508 3 1595 2.5 1723 2 1928 1.5 2327 1 2390 0.95 2459 0.9 2537 0.85 2624 0.8 2722 0.75 2843 0.7 2963 0.65 3114 0.6 3291 0.55 3503 0.5 3762 0.45 4085 0.4 4500 0.35 5053 0.3 5827 0.25 6996 0.2 8974 0.15 13115 0.1 19500 0.07000000 29073 0.05 46000 0.03500000 100000 0.02000000