[node stressihtf2] description = [sim] Stressihtf2 box of MLZ Sample environment group . Controls an High Temperature Furnace with an Eurotherm and an PLC controlling some valves and checking cooling water. meaning={'T_regulation':{'T':100}, 'T_sample':{'T_sample':100}} [interface tcp] type=tcp bindto=0.0.0.0 bindport=10767 [module T] class=secop.simulation.SimDrivable .description=Main temperature control node of Stressihtf2. value.unit='degC' value.default=20 target.datatype=["double", 0, 2000] target.default=20 target.unit='degC' .extra_params=ramp,regulationmode,abslimits,userlimits ramp.datatype=["double",0,600] ramp.description=target ramping speed in K/min. ramp.default=60 ramp.unit=K/min abslimits.datatype=["tuple",[["double"],["double"]]] abslimits.default=[0,2000] abslimits.description=currently active absolute limits for the setpoint. abslimits.unit='degC' abslimits.readonly=True userlimits.datatype=["tuple",[["double"],["double"]]] userlimits.default=[0,300] userlimits.description=current user set limits for the setpoint. must be inside or coincide with abslimits. userlimits.unit='degC' [module T_sample] class=secop.simulation.SimReadable .description=(optional) Sample temperature sensor. .visibility=expert value.default=300 value.unit='degC' [module N2] class=secop.simulation.SimWritable .description=Switches the N2 gas inlet on or off. .visibility=expert value.default='off' value.datatype=["enum", {'off':0,'on':1}] target.datatype=["enum", {'off':0,'on':1}] target.default='off' [module He] class=secop.simulation.SimWritable .description=Switches the He gas inlet on or off. .visibility=expert value.default='off' value.datatype=["enum", {'off':0,'on':1}] target.datatype=["enum", {'off':0,'on':1}] target.default='off' [module lamps] class=secop.simulation.SimWritable .description=Switches the heating lamps on or off. .visibility=expert value.default='on' value.datatype=["enum", {'off':0,'on':1}] target.datatype=["enum", {'off':0,'on':1}] target.default='on' [module water_ok] class=secop.simulation.SimReadable .description=Readout of the cooling water state. .visibility=expert value.default='ok' value.datatype=["enum", {'failed':0,'ok':1}]