for the use case where a parameter is a selection of discrete
float parameters
declaring a parameter as FloatEnumParam will create effectively
two parameters, one with datatype FloatRange and another with
datatype Enum, influencing each other automatically.
in a later change StructParam should be moved from
frappy/structparam.py to frappy/extparams.py
Change-Id: Ica3fd8dcaf6e9439e8178390f220dec15e52cc86
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32975
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
missing f for f string
Change-Id: Ie67384e5b7e514728041a72bd08c850abb31639e
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32786
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
as f-strings are heavily used now, compatibility to py35
can be removed
Change-Id: I1ae4912ad4cbde8419b74845217943bd061053f3
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32754
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
as modules are now stored on secnode instead of dispatcher
Change-Id: Iccda3d97269693a893c06a4e094a9c1dbcf7df0b
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32746
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
when get_module_instance is called a second time after
it failed, the 'cls' element in opts is missing:
move opts dict copy from create_modules to get_module_instance
Change-Id: Ie046f133a8fdbbb1c39643ca16dc5447a9d2d065
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32745
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Transported values in a change must be converted first.
As this is only relevant for the exotic "scaled" and "blob"
datatypes, this was not detected yet.
- add tests
- suppress warning PytestUnhandledThreadExceptionWarning in tests
+ change import_value methods to raise no other exceptions than
WrongTypeError and RangeError
+ simplify Command.do: as import_value already raises the
appropriate error, no more try/except is needed
Change-Id: I299e511468dc0fcecff4c20cf8a917da38b70786
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32743
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
more descriptive error when trying to export OrType, NoneOr, ValueType
and DataTypeType
Change-Id: If13815e9d2b177042b24a1bb62b1ad1d1d88b502
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32737
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
* check argument of do
* automatically set optional struct members from function signature
Change-Id: I95684f1826c1318ea92fad2bd4c9681d85ea72f5
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32501
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
- StringIO.writeline sends a command and does not expect a reply
- StringIO.multicomm and BytesIO.multicomm is improved in order
to insert individual delays in between lines and individual
noreply flags
+ fix a bug in tutorial_t_control
+ improve readability of frappy.lib.classdoc.indent_description
Change-Id: I9dea113e19147684ec41aca5267a79816bbf202c
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32267
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Split module handling code from the dispatcher.
The new class for managing Modules is called SecNode.
* change logging to no longer need a reference to modobj
* modules get a reference to the secnode obj instead of the
dispatcher
* intermediate usage fixes for frappy_psi/sea
Change-Id: Ifee4bb47aa7a4508bb4a47c9a5873b7e2d5faf67
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32249
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
the previous version failed when timestamp was missing
Change-Id: I77e1fb81b19fb4ee2749d731bafacbac46132f8e
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32404
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Looked at this code again, and wondered why the default is not True.
It is far more probable that the programmer just forgets to set
this property to True than it would harm to do so.
Change-Id: I439aedbdfc9c2b12737e3ce1694e90550ddf0e78
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32270
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
bugfix: return only value of execCommand result, not qualifiers
Change-Id: Iff14779050daa9886e9f7d0396317c5a41695cd1
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32235
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
in SecopClient.disconnect joinng the reconnect thread may take
up to 10 s, because of the time.sleep(10) call in the reconnect
thread.
change the _shutdown attribute from bool to an Event, and
use Event.wait instead of time.sleep
Change-Id: Icea6a14ad73df0b3d26ef45806f4c05e6bf18492
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32137
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
in the previous version FloatRange(max=100) was neither working
properly nor complaining, because the maxval=None default was
overriding the value for max.
possible fixes:
- raise an error when min/max used as argument (confusing for
the programmer, as it is a property)
- allow both versions minval/maxval and min/max (more code)
- use min/max and a pylint directive here (the only thing to
take care is not to use the min/max builtin in __init__)
this change uses the last option for the fix
Change-Id: Iff0e0c4d0d7b165003bdeffa67a93a1cd7f29eea
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31982
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
using super() in SimBase.__new__ fixes the problem
Change-Id: I18d0ba6ac476c2edb0d973090bcb09508a983d6a
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32136
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- get_module is to be called when io is autocreated
- register_module is missing in playground
Change-Id: I28884575b71320667107c494473b0fc5d4363a50
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32123
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
on shutdown, time.sleep(10) is blocking the reconnect thread.
change the _shutdown attribute from bool to an Event, and
use Event.wait instead of time.sleep
Change-Id: Icea6a14ad73df0b3d26ef45806f4c05e6bf18492
assumptions about dispatcher in playground.py are no longer
valid.
- let Dispatcher class in playground inherit from real dispatcher
+ improve log messages
Change-Id: I2a9a9d532dabadc590543660c445c021dd2f2891
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31967
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- when driving a module with <module>(<target>),
keyboard interrupt should send stop()
- make sure keyboard interrupt does not only stop
the current driving, but also skips other code
on the same command line
Change-Id: Ib4d2c4111dc0f23bf07385065766fb9b4a611454
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31926
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Dispatcher.get_module_instance returns None on failure.
If that is the case, the dispatcher should not try to register the
None value as a module.
Change-Id: Ie33b8debc2a829d480d56cafc1eb0ab610181d67
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31713
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Some logging calls should not have landed as log.info in the dynamic
modules patch. This fixes that.
Change-Id: I666fc7c9b5c65ddbed1c26ea456becce7870e744
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31707
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
restarting the phytron motor without prior stop leads
to funny behaviour.
- send stop before restart
- stop motor when moving but status not busy
- restart when motor drives the wrong way
+ better status text when stopping
Change-Id: I82cd59297b3c79a354a4eeb5ba03fc65bedf755f
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31929
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
for host name without port, None was used for the port
leading to a confusing error message
- do not call parse_host_port with None as defaultport argument
- improve error message when connection fails
+ fix an error in last line of parse_ipv6_host_and_port
+ fix some issues breaking PEP 8 rules
Change-Id: I437360be96449c164f0080e3c60f1685825d4780
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31911
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
adds a generic solution for creating parameters with struct datatype
with their members linked to individual parameters.
main use case: ctrlpars
read_*/write_* methods are either created for the main (structed)
parameter based on the corresponding methods of the individual
parameters or the methods for the individual parameters are created
based on the methods of the main parameter
+ disable pylint use-dict-literal
Change-Id: I7f1d9fb3d3b2226b548c2999bbfebe2ba5ac285e
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31405
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
add module which scans a connection and registers new devices depending
on the answer.
* change module initialization to demand-based
* move code from server to dispatcher
- remove intermediate step in Attached __get__
TODO:
factor out dispatcher (regards to playground)
discuss factoring out of module creation code from server AND
dispatcher
Change-Id: I7af959b99a84c291c526aac067a4e2bf3cd741d4
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31470
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Georg Brandl <g.brandl@fz-juelich.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
inital reads from HW should be done in the thread started by
startModule, not in startModule itself.
- add a hook method 'initialReads' for this
+ add doc for init methods
+ fix some errors in doc
Change-Id: I914e3b7ee05050eea1ee8aff3461030adf08a461
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31374
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
followup fix: no error was raised ever for the first identification
message.
Change-Id: I80f0f431add6dfd7b37d750b9fc661174aa8f217
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31318
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Georg Brandl <g.brandl@fz-juelich.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>