as historywriter currently could be used at psi only
secop_psi is a better place for it
+ add comment about a general config file
Change-Id: I9b0e74d3da83ac485bd4bcc13475695c3140822c
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/25077
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- removed secop/metaclass.py
- moved code from ModuleMeta to modules.HasAccessibles.__init_subclass__
- reworked properties:
assignment obj.property = value now always allowed
- reworked Parameters and Command to be true descriptors
- Command must now be solely used as decorator
- renamed 'usercommand' to 'Command'
- command methods no longer start with 'do_'
- reworked mechanism to determine accessible order:
the attribute paramOrder, if given, determines order of accessibles
+ fixed some issues makeing the IDE more happy
+ simplified code for StatusType and added a test for it
Change-Id: I8045cf38ee6f4d4862428272df0b12a7c8abaca7
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/25049
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- flatten hierarchy (some links do not work when using folders)
- add a tutorial for programming a simple driver
- clean description using inspect.cleandoc
+ fix a bug with 'unit' pseudo property in a Parameter used as override
Change-Id: I31ddba5d516d1ee5e785e28fbd79fca44ed23f5e
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/25000
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- bugfix: stop searching for file on the first match
- allow to ignore the sign on input by abs (bool) parameter
Change-Id: I0e5544d7645f124d4c4ac720174b0f5bde7e71a6
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/24928
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
The main value of main module is the selected channel, it is 0
when pausing during scanning, and the status is busy.
+ cosmetics to make IDE more happy
Change-Id: I11d8f08ea67d25fb00f7492080b4a55efc124bfb
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/24927
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- includes all changes up to 'fix inheritance order' from git_mlz
6a32ecf34224c559ae558efd7c0d20078d09463b
Change-Id: Ie3ceee3dbd0a9284b47b1d5b5dbe262eebe8f283
- flatten hierarchy (some links do not work when using folders)
+ fix a bug with the redorder flag in Override
+ allow removal of parameters
+ clean description using inspect.cleandoc
Change-Id: I3dde4f4cb29c46e8a21014f1fad7aa3ad610a1bf
the value is the current channel, when the target (=channel) is changed,
the value changes to 0, until the switching has finished, including pause time
- PPMS: improved machanism for 10 K waiting
- LS370: fixed an issue with auto range
+ LS370: show test for all status bits
Change-Id: Ia6454141917893f0e5c6c4351df3a864942bb629
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/23495
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- PPMS: improved machanism for 10 K waiting
- LS370: fixed an issue with auto range
+ LS370: show test for all status bits
Change-Id: Ia6454141917893f0e5c6c4351df3a864942bb629
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/23495
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- treat unknown status values similar to status 0
- wait at 10 K when cooling below
- better error message
Change-Id: Ic07826e31f36abc72ee5d72da001fb1f3d2fe8aa
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/23121
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
includes a use case:
- a software calibration, to be applied to any Readable.
- calibration could be changed on the fly
+ refactored a little bit update events mechanism
Change-Id: Ifa340770caa9eb2185fe7e912c51bd9ddb411ece
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/23093
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
in order to prevent modifying parameters without automatically
trigger updates, all datatypes must be immutable.
TupleOf and ArrayOf: change from list to tuple
StructOf: use ImmutableDict
most existing code should work properly, the only thing to consider are
equality comparisons with lists, which will result to False all the time
the changes in secop_psi/ppms.py (using tuples instead of lists for status values)
are not really necessary, but lead to less confusing code
Change-Id: I181f412b5cd55af296b2e5120af82449beb03f54
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22972
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
use limited float on some parameters
Change-Id: Ic1ec823344a36a1cbcf551fadc8f87073e7b3dac
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22889
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
+ remove unneccessary x mode for some py files
Change-Id: Iaca31fc35ef57805e68e0404c1c7d3240a15f11a
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22571
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
if a write_<parameter> function is defined and <parameter> has an
iohandler, the handlers write function is not called automatically.
It has to be called explicitly in the write_<param> function, if
needed.
reasons:
- the previous logic when a wrapped write function is already present, and a
handler is defined on the specialized class, did not work, and is not
easy to solve properly
- it is probably anyway better to call the handlers write function explicitly
instead of automatically depending on the return value
Change-Id: I04f0849b6cc3fb9979c0f5ac8245a6ab4bf23072
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22565
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Actually, only property values set in the configuration can
be exported, as values equal to the default are not exported.
For this, the mechanism of overwriting properties by class attributes
has to be modified.
Change-Id: I4388d1fbb36393e863556fbbc8df800dd4800c87
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22161
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- make sure new target created by the stop command is between
old and new target
- fixed bad behaviour of level reading
Change-Id: I484c0902c694c0edb81e2d9238985c05f92e04f4
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22100
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
forgot to put the write_* methods in the first change
Change-Id: I4a68d259f6f8f9674b72d88f184efe2b1b15819a
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22099
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
the name commandhandler might be misleading, as it has nothing to do
with SECoP commands
Change-Id: I31bbe1cefd49927fc591619dc7f41f332cca2c14
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22084
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
AH2700: Andeen Hagerling capacitance bridge
This is a use case for 'return Done' in read_<parameter>
K2601b: Keithley source meter
Current and Source are two dependend SECoP modules: only
one of them might be active. Writing to target is allowed only
when active, but both values are always readable.
A common SourceMeter bare Module is present for common functionality.
Change-Id: I6f1875298ef928bcc2d60b89560b837139160775
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22071
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>