reading back the target does not work properly, because
a) the readback value might be delayed
b) there is no command to read back the target, SETP?1
is returning the working setpoint, which might be distinct
in case of a ramp
Change-Id: I0da2dbfc1a8ddbecbae6d0456ff64e008bc56336
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31983
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
add module which scans a connection and registers new devices depending
on the answer.
* change module initialization to demand-based
* move code from server to dispatcher
- remove intermediate step in Attached __get__
TODO:
factor out dispatcher (regards to playground)
discuss factoring out of module creation code from server AND
dispatcher
Change-Id: I7af959b99a84c291c526aac067a4e2bf3cd741d4
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31470
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Georg Brandl <g.brandl@fz-juelich.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
- depending whether client or server side, handling of optional is different
- fix issues when struct is used as keyworded command arguments
Change-Id: I72b347b1a96ee3bce1f67dace4862c313c12c7a9
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/30972
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>