the poller is now a separate (python-)module
- 3 categories of polled parameters:
- regular
- dynamic: accelerated when module is busy
- slow: less frequent, with lower priority
- several modules might share a poller. this makes sense, when a
they share a common communicator
- modules using the new poller must define pollerClass
- pollerClass may be define even an other poller implementation
- the old simple poller is still used on Readables without pollerClass
- the poller can not be configured in the config file only, as the
poll attributes have special values for this poller
Change-Id: Ifd811beeb45733bcbf801608ade877a3a601c24a
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21066
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
- modules and accessibles are changed back to a JSON object
- datatype is changed from a JSON array with 2 elements to
a JSON object with one element, with the basic type as key
- the client side is kept compatible with the old syntax
Change-Id: Icd640bbcdec26a895c96720e107e874529340a73
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21032
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- Enum.__call__(self, value) should raise BadValueError when
value is not hashable
- added TextType.copy (DataType.copy will not work here)
Change-Id: I6c460991fa1e6595a939fb0814f490d2188c97b4
Reviewed-on: https://forge.frm2.tum.de/review/21015
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
messages might get lost after activate, when the number of parameters
exceeds maxlen of the output queue, as a limited deque silently overwrites
messages.
first try: use an infinite deque, but slow down appending thread when deque
gets too big
-> does not work because the appending thread is the same
second try: increase maximum a lot, on overflow log an error message and
close connection
Change-Id: I20376f7e08240dabe43269fa63c596f07e59ddf6
Reviewed-on: https://forge.frm2.tum.de/review/20982
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
baseclient.py:
- select was not used properly, creating a busy loop
- added stop function in TCPConnection
mainwindow.py:
- fixed behaviour when a connection is broken:
a message is shown, and the node is removed from the tree
Change-Id: I7223dfd9ea027681aff089f2fa16e134a16a7b84
Reviewed-on: https://forge.frm2.tum.de/review/20922
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
+ DataType validators are shifted to __call__
+ as_json is moved to export_datatape()
+ new HasProperties Base Mixin for Modules/DataTypes
+ accessibles can be accessed via iterator of a module
+ properties are properly 'derived' and checked, are set with .setPropertyValue
remember: parameters only have properties, so use getPropertyValue()
Change-Id: Iae0273f971aacb00fe6bf05e6a4d24a6d1be881a
Reviewed-on: https://forge.frm2.tum.de/review/20635
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
as for most datatypes as_json had to be converted to properties
and as_json was only not used outside datatypes.py except in
the test, we implement export_datatypes instead
Change-Id: I4beaba9dbd5a350c230e72b571364bf8ee2901b6
Reviewed-on: https://forge.frm2.tum.de/review/20345
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
as Datatype got mutable, it has to be copied when inherited.
Params.copy must call the introduced method Datatype.copy.
in addition:
- fixed bugs in ScaledInteger.__repr__ and datatypes.DATATYPES['struct']
- do not export unit from Parameters
Change-Id: Id552c33843b1b2bedffc68d1bd909705dcfb5605
Reviewed-on: https://forge.frm2.tum.de/review/20324
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
as the unit property may be set in the config file, the datatype
might change after creation.
This proposed implementation changes the internal name of *_precision
to its full name, as this is easier for the way it is done.
IntRange is not yet modified, as anyway 'unit' (and 'fmtstr') should
not be applied to it, this is not forseen in the standard.
Questions for further work:
- should we also allow to configure 'fmtstr'?
- should it be allowed to change min, max from configuration?
- if yes, what is the proper way to do it?
Change-Id: I1fda7e8274109fdcca3c792c0a6e3dc6664cc45e
Reviewed-on: https://forge.frm2.tum.de/review/20304
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- <module>.parameters should contain live parameters on the instance level, not on the class level
- simplified code in Module.__init__, as self.parameters are available
- accessibles on instance level must be OrderedDict, as this is used by describe
Change-Id: Idf507cde5a8f755317e566107214b9a92f3534f7
Reviewed-on: https://forge.frm2.tum.de/review/20302
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
for easier distinction:
- camelCase or singleword: framework method
- snake_case: driver method
(driver) parameters are lowercase, single word framework variables may
have to start with uppercase letters to distinguish...
Change-Id: I76536b6390324625b242c4f190553014c2ca61d6
Reviewed-on: https://forge.frm2.tum.de/review/20295
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>