15 Commits

Author SHA1 Message Date
e6d6179925 init generalConfig.defaults only in secop-server
generalConfig.defaults must not be set on import, as this
depends on import order

Change-Id: I00395b40b4281ddc044c196713f6512068011380
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27985
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
2022-03-22 07:56:38 +01:00
b423235c5d new poll mechanism
- remove secop.poller and basic poller
- regular polls for 'important' parameters done by method doPoll
- all other parameters are polled slower (slowInterval) and
  with lower priority (only one at a time when main poll is due)
- nopoll decorator for read_* to disable poll
- enablePoll attribute (default True) for disabling polling a module
- fast polls may be implemented by means of a statemachine
- configurable slow poll interval
+ allow a Parameter to override a Property (parameter
  Readable.pollinterval overrides Module.pollinterval)

Change-Id: Ib1b3453041a233678b7c4b4add22ac399670e447
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27832
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
2022-03-04 09:58:15 +01:00
c1307cdd03 unify name and module on Attached property
- setting the attribute using the name of an attached module
- getting the attribute results in the module object

+ change names iodev to io, iodevClass to ioClass,
  sendRecv to communicate, HasIodev to HasIO

Change-Id: I200b63a5a7dc1453bf6ac998782b065645201900
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27575
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
2022-01-31 10:57:49 +01:00
b911bc1838 check for problematic value range
A common problematic practice is, to declare the value parameter
with the same FloatRange than the target. Because of measurement
errors, a value might be near, but outside the limit.
In order to avoid this, we force the programmer to declare a
bigger range for the value than for the target, or to
explicitly disable this check on a module property.
It is also fine to declare the value without limits.

This behavior may be disabled via command line option or in the
general config file. For simplicity, FloatRanges inside data
structures are not considered.

+ above command line option is also used to disable the error
  handling on a string to float conversion
+ log appropriate error message for string to float conversion

Change-Id: Ib78ea1fb7c821442bf5847030573c8c27822dea5
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27574
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
2022-01-31 09:12:39 +01:00
f3450375ce enhance logging
- bin/secop-server options -v and -q applied to console logger only
- level for logfile taken from general config
- option for automatic deletion of old logfiles
- added 'comlog' level (between debug and info)

This allows to run the servers by default with 'comlog' level on
the logfiles, which helps a lot for analyzing very rare communication
errors in retrospect.

to avoid spamming of the normal log files, comlog data is stored
separately, one file per communicator

+ redesign of remote logging (no more need of LoggerAdapter)

Change-Id: Ie156a202b1e7304e50bbe830901bc75872f6ffe2
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27427
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
2022-01-17 10:19:55 +01:00
f13e29aad2 introduce general config file
+ redesign general config
+ remove obsolete secop/paths.py

Change-Id: Ice08ec37c54b1a6e2e2e6e29fdaaf0bd2dd725dc
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27362
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
2022-01-05 09:05:00 +01:00
bd56481276 support for multiple secop servers
- server port can be given as cmd line argument
- multiple cfg files may be merged on one server

needed for the way how frappy is planned to be used at PSI

+ add --test option in bin/secop-server

Change-Id: I1e77f65891b15a70b191cbac8168e69715ace3dc
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22947
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
2020-04-23 09:48:08 +02:00
c1164568ae further fixes of py3 issues
complaints by pylint are mainly related to
- remove object from base list in class definitions
- unnecessary else/elif after return/raise

Change-Id: I13d15449149cc8bba0562338d0c9c42e97163bdf
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21325
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
2019-09-26 14:15:48 +02:00
Enrico Faulhaber
70a9c42a7a Remove py2 support
Change-Id: Ieeaeb3b8efcae004e94aea6c1d2703c9782a8650
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21320
Tested-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
2019-09-26 10:32:01 +02:00
Alexander Lenz
449bdcd48b Fix path detection.
Change-Id: If76969e6c753596fff885fdb021ba53b1537c945
2017-09-07 11:08:10 +02:00
Enrico Faulhaber
c0fd2e9907 Use mlzlog for better logging
Change-Id: Ic82ca0d7b43a906cb9c7d3f1350287e7082afc45
2017-05-16 18:17:43 +02:00
Enrico Faulhaber
78bb3b5f96 Pep8 improvements + cleanup
Change-Id: I9052e703b58e93b639c027521b47f693ae853f6e
2016-12-16 14:21:42 +01:00
Enrico Faulhaber
b6af55c358 reworking messages
1) start 'bin/secop-server test'
2) connect to localhost port 10767
3) enter help<enter>
4) enjoy

Change-Id: I488d5f9cdca8c91c583691ab23f541a4a8759f4e
2016-12-08 13:46:32 +01:00
Enrico Faulhaber
8c825a93ed Implement a variant of the Demo protocol from Markus
include LOTs of bugfixes as well

todo: documentation!

Change-Id: I52252ade34966d24990afd9672f38049882c3199
2016-08-31 08:28:51 +02:00
Alexander Lenz
2dae7649be Fix/Improve startup/init.
Change-Id: Ia4b90c75a8cf89f4069bd8984a0e0c88f9ffa832
2016-08-08 13:39:50 +02:00