- remove secop.poller and basic poller
- regular polls for 'important' parameters done by method doPoll
- all other parameters are polled slower (slowInterval) and
with lower priority (only one at a time when main poll is due)
- nopoll decorator for read_* to disable poll
- enablePoll attribute (default True) for disabling polling a module
- fast polls may be implemented by means of a statemachine
- configurable slow poll interval
+ allow a Parameter to override a Property (parameter
Readable.pollinterval overrides Module.pollinterval)
Change-Id: Ib1b3453041a233678b7c4b4add22ac399670e447
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27832
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
- setting the attribute using the name of an attached module
- getting the attribute results in the module object
+ change names iodev to io, iodevClass to ioClass,
sendRecv to communicate, HasIodev to HasIO
Change-Id: I200b63a5a7dc1453bf6ac998782b065645201900
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27575
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- removed secop/metaclass.py
- moved code from ModuleMeta to modules.HasAccessibles.__init_subclass__
- reworked properties:
assignment obj.property = value now always allowed
- reworked Parameters and Command to be true descriptors
- Command must now be solely used as decorator
- renamed 'usercommand' to 'Command'
- command methods no longer start with 'do_'
- reworked mechanism to determine accessible order:
the attribute paramOrder, if given, determines order of accessibles
+ fixed some issues makeing the IDE more happy
+ simplified code for StatusType and added a test for it
Change-Id: I8045cf38ee6f4d4862428272df0b12a7c8abaca7
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/25049
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
+ remove unneccessary x mode for some py files
Change-Id: Iaca31fc35ef57805e68e0404c1c7d3240a15f11a
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22571
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
forgot to put the write_* methods in the first change
Change-Id: I4a68d259f6f8f9674b72d88f184efe2b1b15819a
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22099
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
AH2700: Andeen Hagerling capacitance bridge
This is a use case for 'return Done' in read_<parameter>
K2601b: Keithley source meter
Current and Source are two dependend SECoP modules: only
one of them might be active. Writing to target is allowed only
when active, but both values are always readable.
A common SourceMeter bare Module is present for common functionality.
Change-Id: I6f1875298ef928bcc2d60b89560b837139160775
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22071
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>