Split module handling code from the dispatcher.
The new class for managing Modules is called SecNode.
* change logging to no longer need a reference to modobj
* modules get a reference to the secnode obj instead of the
dispatcher
* intermediate usage fixes for frappy_psi/sea
Change-Id: Ifee4bb47aa7a4508bb4a47c9a5873b7e2d5faf67
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32249
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
'Done' was introduced in order to suppress unneccessary
duplicate updates. However, since super calls on access methods are
allowed, it is not nice when such a method returns Done, as this
is not automagically replaced by the current parameter value.
As a consequence:
- using Done is discouraged, but not (yet) removed in all code
- the 'omit_unchanged_within' property is moved from Module to an
internal Parameter property 'update_unchanged'
- its default is moved from a SEC node property to generalConfig
- the 'update_unchanged' parameter property may be set to
'never' for parameters where duplicate updates make no sense
- this property might be set to 'always', for measurements, where
even unchanged values taken from HW should be transmitted
Change-Id: I2847c983ca09c2c4098e402edd08d0c96c3913f4
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/30672
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- make 'value' a Parameter property instead of an attribute
- use 'value' instead of 'default' property for setting
the initial value in the config file
- removal of initwrite parameter property
this change is the basis of a better implementation
for change 30041 (PersistentParam property 'override_cfg')
Change-Id: I2b82bdd54c2dacb87dcd2b3472004d2f0a730cf0
When several poller threads are using the same io, the resposivity
of client requests is reduced, as every thread first finishes
its pending communication requests, before it is the turn of the
request thread. This is solved by using one common poller thread
for all modules sharing the same communicator.
+ fix an issue with overriding a property with a parameter, as
this is the case for pollperiod (cfg was applied to property
instead of overriding parameter)
+ separate setFastPoll arguments into flag and fast interval
+ fix missing announceUpdate call when read function fails
+ fix mechanism for triggering polls after an io connection
reconnected again.
Change-Id: I1115a61fae3de80d18416e61f40b52a0eebb637c
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28021
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- remove secop.poller and basic poller
- regular polls for 'important' parameters done by method doPoll
- all other parameters are polled slower (slowInterval) and
with lower priority (only one at a time when main poll is due)
- nopoll decorator for read_* to disable poll
- enablePoll attribute (default True) for disabling polling a module
- fast polls may be implemented by means of a statemachine
- configurable slow poll interval
+ allow a Parameter to override a Property (parameter
Readable.pollinterval overrides Module.pollinterval)
Change-Id: Ib1b3453041a233678b7c4b4add22ac399670e447
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27832
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
with handlers, a parameter from the cfg file which is not the
first of parameters with the same handler were not written.
fix: write_<param> method is called for all parameters in
<module>.writeDict even if there is no poll entry.
with this fix, when a parameter has the property initwrite=True,
the write_<param> method is called even when <param>
is not polled and even when <module>.pollerClass is None
Change-Id: I9b397deb5b20709fc4fa7c860c85b251a204c7f6
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/23995
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
writable parameters with a configured value should call write_<param>
on initialization.
+ introduced 'initwrite' parameter property for more fine control over this
+ minor improvements in metaclass.py, param.py, commandhandler.py
+ rearranged test_modules.py
Change-Id: I2eec45da40947a73d9c180f0f146eb62efbda2b3
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21986
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
in the current implementation, in case polling results in an error,
an error_update is generated. But on activate, for this parameter
a normal update will be generated, indicating that this value is ok.
With this change, parameters have an additonal attribue 'readerror',
which save the error generated on the last read, or None, if the
read was successful.
In addition, subsequent repeated errors are only reported the first
time.
Change-Id: I39f18d17debadd8aa5b904e59998d2172f3f11b9
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21974
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
the poller is now a separate (python-)module
- 3 categories of polled parameters:
- regular
- dynamic: accelerated when module is busy
- slow: less frequent, with lower priority
- several modules might share a poller. this makes sense, when a
they share a common communicator
- modules using the new poller must define pollerClass
- pollerClass may be define even an other poller implementation
- the old simple poller is still used on Readables without pollerClass
- the poller can not be configured in the config file only, as the
poll attributes have special values for this poller
Change-Id: Ifd811beeb45733bcbf801608ade877a3a601c24a
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21066
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>