includes a use case:
- a software calibration, to be applied to any Readable.
- calibration could be changed on the fly
+ refactored a little bit update events mechanism
Change-Id: Ifa340770caa9eb2185fe7e912c51bd9ddb411ece
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/23093
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
if a write_<parameter> function is defined and <parameter> has an
iohandler, the handlers write function is not called automatically.
It has to be called explicitly in the write_<param> function, if
needed.
reasons:
- the previous logic when a wrapped write function is already present, and a
handler is defined on the specialized class, did not work, and is not
easy to solve properly
- it is probably anyway better to call the handlers write function explicitly
instead of automatically depending on the return value
Change-Id: I04f0849b6cc3fb9979c0f5ac8245a6ab4bf23072
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22565
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- code for calling write_<param> before write function from handler
is moved to the metaclass
- moved some methods from IOBaseHandler to IOHandler
Change-Id: I733c7fe8d3d59d9013e7b5a33e170c4b3e386921
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22098
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
the name commandhandler might be misleading, as it has nothing to do
with SECoP commands
Change-Id: I31bbe1cefd49927fc591619dc7f41f332cca2c14
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22084
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>