make sure module methods are not called after shutdownModule
+ fix: when mod.enablePoll is False, pollInfo is None
therefore we have to check before access
Change-Id: I83b28607b25996376939175be8abf0c5b27bcac1
The Parameter Properties 'value', 'default' and 'constant'
have ValueType, so they are not checked in the setProperty call.
We have to do this explicitly in Module._add_accessible.
Change-Id: I1e35adf2fe539411b4aebacd813adb07497de95b
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35797
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
The test for method names 'read_<param>' and 'write_<param>'
without a defined parameter is simplified. We do not check
anymore method names from base classes. Base classes
inheriting from HasAccessible are checked anyway at the
place they are defined.
+ add a test for it
+ move some tests to a new file test_all_modules.py, as
test_modules.py is getting too long
+ fix missing doc string (frappy.simulation.SimDrivable.stop)
Change-Id: Id8a9afe5c977ae3b1371bd40c6da52be2fc79eb9
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35503
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
This is meant to replace change 33375.
Optional commands and parameters may be declared with the argument
optional=True. In principle, optional commands are not really needed
to be declared, but doing so is nice for documentation reasons
and for inherited accessible properties.
Optional parameters and commands can not be used and are not
exported als long as they are not overridden in subclasses.
- add a test for this
+ fix an issue with checking for methods like read_<param> without
<param> being a parameter
Change-Id: Ide5021127a02778e7f2f7162555ec8826f1471cb
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35495
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Add a new custom module property 'original_id' indicating
the equipment_id the modules originally belongs to.
This property is only given, when distinct from the equipment_id
of the SEC node.
It happens when multiple config files are given, for all modules
but the ones given in the first file, and for routed modules,
when multiple nodes are routed or own modules are given.
+ fix an issue in router: additional modules were ignore in case
of a single node.
+ small cosmetic changes in config.py reducing IDE complains
Change-Id: If846c47a06158629cef807d22b91f69e4f416563
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35396
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
slight change to make it compatible with py 3.6/3.7, where
reversed(<dict>) was not allowed.
Change-Id: Id440870b5523a866b3afb470ba5db9cd6a9bb0ec
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35002
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- predefined parameters/commands appear first, in the order
defined in frappy.params.PREDEFINED_ACCESSIBLES
- other (custom) parameters by inheritance order
- remove paramOrder attribute (not used currently)
Change-Id: If4c43189e4837dba057dc0a430ac6c3d1ae10829
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/34904
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
installing a custom logger was not possible, since the RemoteLogHandler
was not installed.
Additionally, search for the RemoteLogHandler recursively upwards, since
not all loggers copy their Hanlders to their children.
Change-Id: If3e19966d9289cacd926648582e9718b7eab279c
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/34288
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
triggerPoll must be set on attached io
Change-Id: If3fa1016efa6047371380790f60db246d87b3628
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/33269
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- fix inheritance of command description
- when no stop method is given, then the description should indicate
that stop is a no-op -> add missing doc strings to stop methods
- add test to make sure stop command doc strings are given
when implemented
Change-Id: If891359350e8dcdec39a706841d61d4f8ec8926f
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/33266
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
on Module, use one single callback list 'paramsCallback' instead of
'valueCallbacks', 'errorCallbacks'. Redesign the mechanism to
avoid most of the closures.
Change-Id: Ie7f68f6bf97ab3f3cd961faa20b0e77730e5b37d
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/33118
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
- for the case when the remote module name does not match,
'read', 'change' and 'do' does not work
- a proxy to an IO class has enablePoll == False, but it needs
a triggerPoll for modules relying on it to work
- a proxy on a communicator module has a status even when the
remote does not - this needs 2 fixes
Change-Id: Icd44da4c2984f27ce7147dec633739f9176012ec
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/33168
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
as f-strings are heavily used now, compatibility to py35
can be removed
Change-Id: I1ae4912ad4cbde8419b74845217943bd061053f3
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32754
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Split module handling code from the dispatcher.
The new class for managing Modules is called SecNode.
* change logging to no longer need a reference to modobj
* modules get a reference to the secnode obj instead of the
dispatcher
* intermediate usage fixes for frappy_psi/sea
Change-Id: Ifee4bb47aa7a4508bb4a47c9a5873b7e2d5faf67
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32249
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>