a read method should not reply on the automatic conversion
of the return value from string to a number.
- transitional solution with generalConfig.lazy_numer_validation
+ changing slighly generalInit mechanism: for above feature
generalConfig.init is not required to be called (i.e. when
used on the client side)
Change-Id: Ibecce1a45669273c105932acdc0908de55bfd1b9
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27516
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
modules with a couple of parameters with similar read_* or
write_* methods may handle them by generic methods wrapped
with decorators ReadHandler / WriteHandler
The trinamic driver is included in this change for demonstrating
how it works.
In a further step, the special handling for the iohandler stuff can
be moved away from secop.server and secop.params, using this feature.
+ fix problem on startup of trinamic driver (needs MultiEvent.queue)
+ some other small fixes
+ apply recommended functools.wraps for wrapping
Change-Id: Ibfeff9209f53c47194628463466cee28366e17ac
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27460
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- bin/secop-server options -v and -q applied to console logger only
- level for logfile taken from general config
- option for automatic deletion of old logfiles
- added 'comlog' level (between debug and info)
This allows to run the servers by default with 'comlog' level on
the logfiles, which helps a lot for analyzing very rare communication
errors in retrospect.
to avoid spamming of the normal log files, comlog data is stored
separately, one file per communicator
+ redesign of remote logging (no more need of LoggerAdapter)
Change-Id: Ie156a202b1e7304e50bbe830901bc75872f6ffe2
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27427
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- fix CommandType.__repr__
- secop/modules.py: command properties are allowed to be configured:
- section 2: remove comment and rename
- section 3: all accessible properties should be checked
- command description should be inherited also when taken from docstring
- move test for command inheritance to test_modules.py
- added tests to check for valid properties of commands
Change-Id: Ic7795e305048625558e415ece099e6824df6e2c4
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27135
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Correct inheritance has to follow the MRO, not only consider
the direct base classes.
Patchset 3: changed only tests, indicating that we need to change the code
Following patchsets include a major change in params.py and
modules.py. The parameter properties for inheritance, corresponding
mainly to the constructor arguments have to be stored separately
from the property values including inherited stuff.
Change-Id: Ibcbccb6abcc22e7e2d91df8f70ef64226684d8cc
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/26805
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
- nodestatechange callback must appear after the online attribute
is changed
- IntRange: move range validation outside of try except
- fixes on some error names
- well defined error message 'no such class' in secop.lib.get_class
- try again 4 times when starting Tcp Server on EADDRINUSE
- fix error handling
Change-Id: I4eee9b79ea8173936b9f5193b87e006ac8fca827
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/26171
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Config errors are collected first, and raised after processing
all modules. This is more user friendly.
+ remove redundant check for predefined accessibles in modules.py
+ fixed error handling for exporting parameters in params.py
+ fixed handling of bare attributes overwriting properties
+ fixed race condition in writeInitParams
Change-Id: I894bda291ab85ccec3d771c4903393c808af0a2a
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/25128
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- a new wrapper for a read function is not only to be created when
the a new read method is in the class dict, but also when
it is inherited, but not yet wrapped
- a handler must not be ignored, when a write method is inherited
- a proxy class must not call checkProperties
+ remove trailing spaces in tutorial_helevel.rst
Change-Id: I16024c14232ea200db91a1bc07ec23326219ab68
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/25093
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- removed secop/metaclass.py
- moved code from ModuleMeta to modules.HasAccessibles.__init_subclass__
- reworked properties:
assignment obj.property = value now always allowed
- reworked Parameters and Command to be true descriptors
- Command must now be solely used as decorator
- renamed 'usercommand' to 'Command'
- command methods no longer start with 'do_'
- reworked mechanism to determine accessible order:
the attribute paramOrder, if given, determines order of accessibles
+ fixed some issues makeing the IDE more happy
+ simplified code for StatusType and added a test for it
Change-Id: I8045cf38ee6f4d4862428272df0b12a7c8abaca7
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/25049
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- flatten hierarchy (some links do not work when using folders)
- add a tutorial for programming a simple driver
- clean description using inspect.cleandoc
+ fix a bug with 'unit' pseudo property in a Parameter used as override
Change-Id: I31ddba5d516d1ee5e785e28fbd79fca44ed23f5e
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/25000
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
New Syntax:
- define properties and parameters as class attributes directly
instead of items in class attribute dicts
- define commands with decorator @usercommand(...)
- old syntax is still supported for now
still to do (with decreasing priority):
- turn parameters into descriptors (vs. creating getters/setters)
- migrate all existing code to new syntax
- get rid of or reduce code in metaclasses using __set_name__ and
__init_subclass__ instead, including a fix for allowing py < 3.6
Change-Id: Id47e0f89c506f50c40fa518b01822c6e5bbf4e98
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/24991
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- when applying overrides with reorder=True, take ctr from Override,
else copy from the cloned Accesible. This did not work properly
- reworked:
- replaced CountedObj class by object_counter
- accessibles created by a copy or by applying Overrides
do not need fresh counted values
- adjusted tests
Change-Id: Id2fcf1ab1295aa1ea80ea81ae8cd02d36f86e969
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/24926
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
with handlers, a parameter from the cfg file which is not the
first of parameters with the same handler were not written.
fix: write_<param> method is called for all parameters in
<module>.writeDict even if there is no poll entry.
with this fix, when a parameter has the property initwrite=True,
the write_<param> method is called even when <param>
is not polled and even when <module>.pollerClass is None
Change-Id: I9b397deb5b20709fc4fa7c860c85b251a204c7f6
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/23995
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>