- allow (description and) datatype being positional args in Override
- disallow ctr and unit being a positional arg in Parameter
- disallow reorder being a positional arg in Override
Change-Id: Ic5711d091af11d5843943b0b2b31567127f8ed8c
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/24934
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- when applying overrides with reorder=True, take ctr from Override,
else copy from the cloned Accesible. This did not work properly
- reworked:
- replaced CountedObj class by object_counter
- accessibles created by a copy or by applying Overrides
do not need fresh counted values
- adjusted tests
Change-Id: Id2fcf1ab1295aa1ea80ea81ae8cd02d36f86e969
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/24926
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
with handlers, a parameter from the cfg file which is not the
first of parameters with the same handler were not written.
fix: write_<param> method is called for all parameters in
<module>.writeDict even if there is no poll entry.
with this fix, when a parameter has the property initwrite=True,
the write_<param> method is called even when <param>
is not polled and even when <module>.pollerClass is None
Change-Id: I9b397deb5b20709fc4fa7c860c85b251a204c7f6
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/23995
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
A proxy module is a module with a known structure, but
accessed over a SECoP connection.
For the configuration, a Frappy module class has to be given.
The proxy class is created from this, but does not inherit from it.
However, the class of the returned object will be subclass of the
SECoP base classes (Readable, Drivable etc.).
A possible extension might be, that instead of the Frappy class,
the JSON module description can be given, as a separate file
or directly in the config file.
Or we might offer a tool to convert the JSON description to
a python class.
Change-Id: I9212d9f3fe82ec56dfc08611d0e1efc0b0112271
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22386
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
This change allows compilation under python 3.4. In addition:
- spec file added for pyinstaller with required hidden imports
- changed default pathes for compiled exe file
- added requirements for ppms under windows compilation
Change-Id: I63d805a984d6a2c045df527303f46c8440994aad
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22170
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Reviewed-by: Petr Cermak <cermak@mag.mff.cuni.cz>
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Tested-by: Petr Cermak <cermak@mag.mff.cuni.cz>
writable parameters with a configured value should call write_<param>
on initialization.
+ introduced 'initwrite' parameter property for more fine control over this
+ minor improvements in metaclass.py, param.py, commandhandler.py
+ rearranged test_modules.py
Change-Id: I2eec45da40947a73d9c180f0f146eb62efbda2b3
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21986
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
in the current implementation, in case polling results in an error,
an error_update is generated. But on activate, for this parameter
a normal update will be generated, indicating that this value is ok.
With this change, parameters have an additonal attribue 'readerror',
which save the error generated on the last read, or None, if the
read was successful.
In addition, subsequent repeated errors are only reported the first
time.
Change-Id: I39f18d17debadd8aa5b904e59998d2172f3f11b9
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21974
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
parameters with a common commandhandler need only one poller item
Change-Id: Ie2e20cf7bcebc67ca96d58455323f01f528b25ab
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21951
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
A command handler can be used to deal with parameters which have a common
command for querying and writing to the hardware. Support for parsing
and formatting commands is included.
Change-Id: I79a1b6c9daf3af3be2e1875875ced41ec1a1829d
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21946
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
but still optional with default True for frappy Parameter
Change-Id: I416c835af324ec3875aaa785cd0aefb28f9bfaa3
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21457
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Before the introduction of the Property, the default of the poll
property was False. I feel that this is a better default, as the
programmer should think about which parameters really need to be
polled.
+ change comment about poll property (meaning depends on Poller)
+ change name of Status datatype to StatusType (avoid name conflicts
with Status enum type)
Change-Id: Ie405b10ce8dfe85b235dbe78c910b5b5ee22cbb1
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21407
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
this change is triggered by the fact, that assigining a unit
in the config file did no longer work.
this change has several implications:
1) secop.properties must not import secop.datatypes:
- as ValueType can not be imported, the default behaviour with
'mandatory' and 'default' arguments was slightly changed
- instead of checking for DataType when exporting, a try/except
was used
2) the datatype of datatype properties is sometimes not yet defined.
a stub is used in this cases instead, which is later replaced by
the proper datatype. The number of stubs may be reduced, but this
should be done in a later change, as the diff will be much less
readable.
3) in config files, datatype properties can be changed like parameter
properties. HasProperties.setProperties/checkProperties/getProperties
are overridden for this.
the config editor seems still to work, an issue (probably py3) had
to be fixed there
Change-Id: I1efddf51f2c760510e913dbcaa099e8a89c9cab5
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21399
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
some u"" (double quotes) were not found in change before
Change-Id: I85912892bbe7b57afee758c69d1aa7073557adc0
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21326
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Bjoern Pedersen <bjoern.pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
complaints by pylint are mainly related to
- remove object from base list in class definitions
- unnecessary else/elif after return/raise
Change-Id: I13d15449149cc8bba0562338d0c9c42e97163bdf
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21325
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- according to SECoP v1.0
- internally the name 'datatype' is kept
Change-Id: I0298a45f2db529ced3a07e2e9b344c91cfb7bb88
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21300
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
predefined parameters must be in the 'exported' dict of Parameters
else they are not exported
Change-Id: Ic23dc0477c135b5160fe3e0fb39069e0c5e5cca1
Reviewed-on: https://forge.frm2.tum.de/review/20981
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
+ DataType validators are shifted to __call__
+ as_json is moved to export_datatape()
+ new HasProperties Base Mixin for Modules/DataTypes
+ accessibles can be accessed via iterator of a module
+ properties are properly 'derived' and checked, are set with .setPropertyValue
remember: parameters only have properties, so use getPropertyValue()
Change-Id: Iae0273f971aacb00fe6bf05e6a4d24a6d1be881a
Reviewed-on: https://forge.frm2.tum.de/review/20635
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
as Datatype got mutable, it has to be copied when inherited.
Params.copy must call the introduced method Datatype.copy.
in addition:
- fixed bugs in ScaledInteger.__repr__ and datatypes.DATATYPES['struct']
- do not export unit from Parameters
Change-Id: Id552c33843b1b2bedffc68d1bd909705dcfb5605
Reviewed-on: https://forge.frm2.tum.de/review/20324
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
for easier distinction:
- camelCase or singleword: framework method
- snake_case: driver method
(driver) parameters are lowercase, single word framework variables may
have to start with uppercase letters to distinguish...
Change-Id: I76536b6390324625b242c4f190553014c2ca61d6
Reviewed-on: https://forge.frm2.tum.de/review/20295
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
needs a bigger rework, since READREPLY and EVENTREPLY are now different....
Also the format of the error-reply got changed :(
Change-Id: I1760743238227730ee49aaf92b54e0ff5f25423b
Reviewed-on: https://forge.frm2.tum.de/review/20246
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
except when explicitely mentioned with reorder=True
improved test_modules for unique accessibles, as this
was related with Accessible.ctr
Change-Id: I61877de9300bb0297c88a6c44bb265c634937856
Reviewed-on: https://forge.frm2.tum.de/review/19693
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
the export argument of an accessible allows now to specify an other
external name than the attribute used internally.
export=True (default, use defined name, or prefix with '_' when
name not in predefined list)
export=False (do not export)
export=<any string> (special cases only)
Change-Id: I6c6669cd502d9d6fd3aa40091673e5554fd961bd
Reviewed-on: https://forge.frm2.tum.de/review/19664
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
- custom properties: to be declared at startup calling the
classmethods Parameter.add_property or Command.add_property
Probably the call should be placed in secop_<facility>/__init__.py
- valid properties are listed in Parameter.valid_properties /
Command.valid_properties. New properties without relation to code
in the SECnode like fmtstr, group, visibility can be added at one
place in code only
Change-Id: I8c550eba955473665d246ddef3815b23c68be4f7
Reviewed-on: https://forge.frm2.tum.de/review/19611
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
modified cryo.py for using Override correctly, here the description of the stop command is overridden
Change-Id: I060a2802226239f3af3dc1e573b7148d863b938c
Reviewed-on: https://forge.frm2.tum.de/review/19607
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
- for now, the definition also accepts the old syntax
(to be changed later)
- Commands have datatype CommandType
- do not need keyword for the decription parameter of Override
- issue a Warning when a Parameter is overwritten without Overrride
(this should be turned into an error message)
-
Change-Id: Ib2c0f520abb5b4d7e6aed4d77a0d2b8bc470a85a
Reviewed-on: https://forge.frm2.tum.de/review/18251
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>