Add a new custom module property 'original_id' indicating
the equipment_id the modules originally belongs to.
This property is only given, when distinct from the equipment_id
of the SEC node.
It happens when multiple config files are given, for all modules
but the ones given in the first file, and for routed modules,
when multiple nodes are routed or own modules are given.
+ fix an issue in router: additional modules were ignore in case
of a single node.
+ small cosmetic changes in config.py reducing IDE complains
Change-Id: If846c47a06158629cef807d22b91f69e4f416563
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35396
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- fix a bug then TcpServer can not start dye to address in use
- report errors when restarting interfaces
- increase timeout. the timeout for waiting all interfaces
starting up must be higher than a potential successful
startup of TcpServer, which is currently ~ 10 sec
(might be reduced, but at both places)
Change-Id: I88b967c4baff79fdf94f4c849dd713d2cba6fabc
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/33985
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Transported values in a change must be converted first.
As this is only relevant for the exotic "scaled" and "blob"
datatypes, this was not detected yet.
- add tests
- suppress warning PytestUnhandledThreadExceptionWarning in tests
+ change import_value methods to raise no other exceptions than
WrongTypeError and RangeError
+ simplify Command.do: as import_value already raises the
appropriate error, no more try/except is needed
Change-Id: I299e511468dc0fcecff4c20cf8a917da38b70786
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32743
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Split module handling code from the dispatcher.
The new class for managing Modules is called SecNode.
* change logging to no longer need a reference to modobj
* modules get a reference to the secnode obj instead of the
dispatcher
* intermediate usage fixes for frappy_psi/sea
Change-Id: Ifee4bb47aa7a4508bb4a47c9a5873b7e2d5faf67
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32249
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
An attached property may be defined with mandatory=False.
In this case, when no value or an empty string is given,
<modobj>.<attached_mod> must return None after initialisation.
+ remove 'dispatcher' level from the logger hierarchy on modules
Change-Id: Icee3ae3f9142cd7a910c579ae1ffaa35f93cee03
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32187
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
add module which scans a connection and registers new devices depending
on the answer.
* change module initialization to demand-based
* move code from server to dispatcher
- remove intermediate step in Attached __get__
TODO:
factor out dispatcher (regards to playground)
discuss factoring out of module creation code from server AND
dispatcher
Change-Id: I7af959b99a84c291c526aac067a4e2bf3cd741d4
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31470
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Georg Brandl <g.brandl@fz-juelich.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
%d accepts floats and other things, so manual fixes are needed after
conversion.
After flynt -ll 2000 --aggressive, each was manually checked if the
casts with int() are needed.
Two statements are still missing in ls370res
Change-Id: I2651ddbe60695aa19582882a97d0f71bcb05c1ef
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/30901
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
- include all secop errors from spec
- add doc strings
- make conversion to and from error report nicer
- move all error classes to frappy.errors
- rename errors clashing with built-in errors
Change-Id: I4d882173b020cd4baf862c5891375b691e67e24a
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/30721
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
'Done' was introduced in order to suppress unneccessary
duplicate updates. However, since super calls on access methods are
allowed, it is not nice when such a method returns Done, as this
is not automagically replaced by the current parameter value.
As a consequence:
- using Done is discouraged, but not (yet) removed in all code
- the 'omit_unchanged_within' property is moved from Module to an
internal Parameter property 'update_unchanged'
- its default is moved from a SEC node property to generalConfig
- the 'update_unchanged' parameter property may be set to
'never' for parameters where duplicate updates make no sense
- this property might be set to 'always', for measurements, where
even unchanged values taken from HW should be transmitted
Change-Id: I2847c983ca09c2c4098e402edd08d0c96c3913f4
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/30672
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- fixed this for 'read', 'change' and 'do' message
+ fix an error in frappy.client.SecopClient closing the connection
when the identifier is None
fixes: #4672
Change-Id: Iaba0f9ed86b6eb6ef7588403ba640ded552dded6
- use Datatype.validate for converting and checking limits
(used also in properties)
- Datatype.__call__ converts and validates, but without checking
limits (used in setter)
- Datatype.validate may be used to add missing optional struct elements
from previous value (used in Dispatcher._setParameterValue)
- remove problematic range check
+ use shorter formula for converting float to int in ScaledInteger
(leftover from python2 compatibility)
+ improve error messages (strip very long repr(value))
Change-Id: Ib85736fe558ec3370ebce4e1c43f957e3bb0497c
- Change Configuration format to be python-based.
- move config logic to frappy/config.py
- Add first py-config: cryo_cfg.py
- Adapt test to new expected config format
Change-Id: Iaec484e0e1e21ebbb1e5c74b53be6231329ddf71