enhance logging
- bin/secop-server options -v and -q applied to console logger only - level for logfile taken from general config - option for automatic deletion of old logfiles - added 'comlog' level (between debug and info) This allows to run the servers by default with 'comlog' level on the logfiles, which helps a lot for analyzing very rare communication errors in retrospect. to avoid spamming of the normal log files, comlog data is stored separately, one file per communicator + redesign of remote logging (no more need of LoggerAdapter) Change-Id: Ie156a202b1e7304e50bbe830901bc75872f6ffe2 Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27427 Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de> Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
This commit is contained in:
@ -71,6 +71,7 @@ class Main(HasIodev, Drivable):
|
||||
_channels = None # dict <channel no> of <module object>
|
||||
|
||||
def earlyInit(self):
|
||||
super().earlyInit()
|
||||
self._channels = {}
|
||||
|
||||
def register_channel(self, modobj):
|
||||
@ -166,6 +167,7 @@ class ResChannel(HasIodev, Readable):
|
||||
_trigger_read = False
|
||||
|
||||
def initModule(self):
|
||||
super().initModule()
|
||||
self._main = self.DISPATCHER.get_module(self.main)
|
||||
self._main.register_channel(self)
|
||||
|
||||
@ -228,7 +230,7 @@ class ResChannel(HasIodev, Readable):
|
||||
if autorange:
|
||||
result['autorange'] = 'hard'
|
||||
# else: do not change autorange
|
||||
self.log.info('%s range %r %r %r' % (self.name, rng, autorange, self.autorange))
|
||||
self.log.debug('%s range %r %r %r' % (self.name, rng, autorange, self.autorange))
|
||||
if excoff:
|
||||
result.update(iexc=0, vexc=0)
|
||||
elif iscur:
|
||||
|
Reference in New Issue