make entangle mapping a dict
Change-Id: I38d863a907469674001f0721140f88c17b53635b Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/30911 Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de> Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de> Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
This commit is contained in:
@ -13,14 +13,14 @@ Mod('automatik',
|
||||
'\n'
|
||||
'selects between off, regulate on p1 or regulate on p2 sensor',
|
||||
tangodevice = 'tango://localhost:10000/box/plc/_automatik',
|
||||
mapping="{'Off':0,'p1':1,'p2':2}",
|
||||
mapping={'Off':0,'p1':1,'p2':2},
|
||||
)
|
||||
|
||||
Mod('compressor',
|
||||
'frappy_mlz.entangle.NamedDigitalOutput',
|
||||
'control the compressor (on/off)',
|
||||
tangodevice = 'tango://localhost:10000/box/plc/_cooler_onoff',
|
||||
mapping="{'Off':0,'On':1}",
|
||||
mapping={'Off':0,'On':1},
|
||||
)
|
||||
|
||||
Mod('gas',
|
||||
@ -31,7 +31,7 @@ Mod('gas',
|
||||
'note: activation de-activates the vacuum inlet\n'
|
||||
'note: if the pressure regulation is active, it enslave this device',
|
||||
tangodevice = 'tango://localhost:10000/box/plc/_gas_onoff',
|
||||
mapping="{'Off':0,'On':1}",
|
||||
mapping={'Off':0,'On':1},
|
||||
)
|
||||
|
||||
Mod('vacuum',
|
||||
@ -41,7 +41,7 @@ Mod('vacuum',
|
||||
'note: activation de-activates the gas inlet\n'
|
||||
'note: if the pressure regulation is active, it enslave this device',
|
||||
tangodevice = 'tango://localhost:10000/box/plc/_vacuum_onoff',
|
||||
mapping="{'Off':0,'On':1}",
|
||||
mapping={'Off':0,'On':1},
|
||||
)
|
||||
|
||||
Mod('p1',
|
||||
@ -63,14 +63,14 @@ Mod('curve_p2',
|
||||
'calibration curve for pressure sensor 2',
|
||||
tangodevice = 'tango://localhost:10000/box/plc/_curve',
|
||||
value = 0,
|
||||
mapping = "{'0-10V':0, '0-1000mbar':1, '1-9V to 0-1 mbar':2, \
|
||||
'DI200':3, 'DI2000':4, 'TTR100':7, 'PTR90':8, \
|
||||
'PTR225/237':9, 'ITR90':10, 'ITR100-D':11, \
|
||||
'ITR100-2':12, 'ITR100-3':13, 'ITR100-4':14, \
|
||||
'ITR100-5':15, 'ITR100-6':16, 'ITR100-7':17, \
|
||||
'ITR100-8':18, 'ITR100-9':19, 'ITR100-A':20, \
|
||||
'CMR361':21, 'CMR362':22, 'CMR363':23, \
|
||||
'CMR364':24, 'CMR365':25}",
|
||||
mapping = {'0-10V':0, '0-1000mbar':1, '1-9V to 0-1 mbar':2,
|
||||
'DI200':3, 'DI2000':4, 'TTR100':7, 'PTR90':8,
|
||||
'PTR225/237':9, 'ITR90':10, 'ITR100-D':11,
|
||||
'ITR100-2':12, 'ITR100-3':13, 'ITR100-4':14,
|
||||
'ITR100-5':15, 'ITR100-6':16, 'ITR100-7':17,
|
||||
'ITR100-8':18, 'ITR100-9':19, 'ITR100-A':20,
|
||||
'CMR361':21, 'CMR362':22, 'CMR363':23,
|
||||
'CMR364':24, 'CMR365':25},
|
||||
)
|
||||
|
||||
Mod('T_tube_regulation',
|
||||
@ -137,12 +137,12 @@ Mod('T_tube_regulation_heaterrange',
|
||||
'frappy_mlz.entangle.NamedDigitalOutput',
|
||||
'heaterrange for tube regulation',
|
||||
tangodevice = 'tango://localhost:10000/box/tube/range1',
|
||||
mapping="{'Off':0,'Low':1,'Medium':2, 'High':3}",
|
||||
mapping={'Off':0,'Low':1,'Medium':2, 'High':3},
|
||||
)
|
||||
|
||||
Mod('T_stick_regulation_heaterrange',
|
||||
'frappy_mlz.entangle.NamedDigitalOutput',
|
||||
'heaterrange for stick regulation',
|
||||
tangodevice = 'tango://localhost:10000/box/stick/range2',
|
||||
mapping="{'Off':0,'Low':1,'Medium':2, 'High':3}",
|
||||
mapping={'Off':0,'Low':1,'Medium':2, 'High':3},
|
||||
)
|
||||
|
Reference in New Issue