Change leftover %-logging calls to lazy
Change-Id: I0bee8d02ac364ab93f77919cae78afa386b85c85 Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/30899 Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de> Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
This commit is contained in:
@@ -237,8 +237,8 @@ class Cryostat(CryoBase):
|
||||
heater = self.heater
|
||||
|
||||
heatflow = self.__heatLink(regulation, sample)
|
||||
self.log.debug('sample = %.5f, regulation = %.5f, heatflow = %.5g'
|
||||
% (sample, regulation, heatflow))
|
||||
self.log.debug('sample = %.5f, regulation = %.5f, heatflow = %.5g',
|
||||
sample, regulation, heatflow)
|
||||
newsample = max(0, sample + (self.__sampleLeak(sample) - heatflow)
|
||||
/ self.__sampleCP(sample) * h)
|
||||
# avoid instabilities due to too small CP
|
||||
@@ -293,7 +293,7 @@ class Cryostat(CryoBase):
|
||||
lastD = _D
|
||||
|
||||
self.log.debug('PID: P = %.2f, I = %.2f, D = %.2f, '
|
||||
'heater = %.2f' % (_P, _I, _D, heater))
|
||||
'heater = %.2f', _P, _I, _D, heater)
|
||||
|
||||
# check for turn-around points to detect oscillations ->
|
||||
# increase damper
|
||||
@@ -321,8 +321,8 @@ class Cryostat(CryoBase):
|
||||
try:
|
||||
self.setpoint = round(self.setpoint + clamp(
|
||||
self.target - self.setpoint, -maxdelta, maxdelta), 3)
|
||||
self.log.debug('setpoint changes to %r (target %r)' %
|
||||
(self.setpoint, self.target))
|
||||
self.log.debug('setpoint changes to %r (target %r)',
|
||||
self.setpoint, self.target)
|
||||
except (TypeError, ValueError):
|
||||
# self.target might be None
|
||||
pass
|
||||
|
||||
@@ -169,12 +169,12 @@ class MagneticField(Drivable):
|
||||
if self._state == self._state.enum.switch_on:
|
||||
# wait until switch is on
|
||||
if self._heatswitch.read_value() == 'on':
|
||||
self.log.debug('heatswitch is on -> ramp to %.3f' %
|
||||
self.log.debug('heatswitch is on -> ramp to %.3f',
|
||||
self.target)
|
||||
self._state = self._state.enum.ramp
|
||||
if self._state == self._state.enum.ramp:
|
||||
if self.target == self.value:
|
||||
self.log.debug('at field! mode is %r' % self.mode)
|
||||
self.log.debug('at field! mode is %r', self.mode)
|
||||
if self.mode:
|
||||
self.log.debug('at field -> switching heater off')
|
||||
self._state = self._state.enum.switch_off
|
||||
@@ -190,7 +190,7 @@ class MagneticField(Drivable):
|
||||
if self._state == self._state.enum.switch_off:
|
||||
# wait until switch is off
|
||||
if self._heatswitch.read_value() == 'off':
|
||||
self.log.debug('heatswitch is off at %.3f' % self.value)
|
||||
self.log.debug('heatswitch is off at %.3f', self.value)
|
||||
self._state = self._state.enum.idle
|
||||
self.read_status() # update async
|
||||
time.sleep(max(0.01, ts + loopdelay - time.time()))
|
||||
|
||||
Reference in New Issue