Rename from secop to frappy
debian/ is still missing, will follow in next commit. Fixes: #4626 Change-Id: Ia87c28c1c75b8402eedbfca47f888585a7881f44
This commit is contained in:
committed by
Enrico Faulhaber
parent
c1eb764b09
commit
7f166a5b8c
@@ -11,7 +11,7 @@ bindto=0.0.0.0
|
||||
bindport=10767
|
||||
|
||||
[module T_ccidu1]
|
||||
class=secop.simulation.SimDrivable
|
||||
class=frappy.simulation.SimDrivable
|
||||
.description=Main temperature control node of ccidu1.
|
||||
.
|
||||
Controls the regulation loop of the ls372.
|
||||
@@ -26,7 +26,7 @@ ramp.default=60
|
||||
.meaning=["temperature_regulation",40]
|
||||
|
||||
[module T_ccidu1_A]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=mixing chamber temperature sensor. Also used for the regulation.
|
||||
.visibility=expert
|
||||
value.default=300
|
||||
@@ -34,7 +34,7 @@ value.datatype={"type":"double", "unit":"K"}
|
||||
.meaning=["temperature",38]
|
||||
|
||||
[module T_ccidu1_B]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=(optional) sample temperature sensor close to sample.
|
||||
.visibility=user
|
||||
value.default=300
|
||||
@@ -42,49 +42,49 @@ value.datatype={"type":"double", "unit":"K"}
|
||||
.meaning=["temperature",39]
|
||||
|
||||
[module ccidu1_pstill]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=Pressure at the still/turbo pump inlet.
|
||||
.visibility=expert
|
||||
value.default=999
|
||||
value.datatype={"type":"double", "unit":"mbar"}
|
||||
|
||||
[module ccidu1_pinlet]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=Pressure at forepump inlet/turbo pump outlet.
|
||||
.visibility=expert
|
||||
value.default=999
|
||||
value.datatype={"type":"double", "unit":"mbar"}
|
||||
|
||||
[module ccidu1_poutlet]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=Pressure at forepump outlet/compressor inlet.
|
||||
.visibility=expert
|
||||
value.default=999
|
||||
value.datatype={"type":"double", "unit":"mbar"}
|
||||
|
||||
[module ccidu1_pkond]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=Pressure at condensing line/compressor outlet.
|
||||
.visibility=expert
|
||||
value.default=999
|
||||
value.datatype={"type":"double", "unit":"mbar"}
|
||||
|
||||
[module ccidu1_ptank]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=Pressure in dump tank.
|
||||
.visibility=expert
|
||||
value.default=999
|
||||
value.datatype={"type":"double", "unit":"mbar"}
|
||||
|
||||
[module ccidu1_pvac]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=Pressure in the vacuum dewar (ivc).
|
||||
.visibility=expert
|
||||
value.default=999
|
||||
value.datatype={"type":"double", "unit":"mbar"}
|
||||
|
||||
[module ccidu1_flow]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=Gas Flow (condensing line).
|
||||
.visibility=expert
|
||||
value.default=999
|
||||
@@ -92,14 +92,14 @@ value.datatype={"type":"double", "unit":"mbar"}
|
||||
|
||||
# note: all valves and switches are missing: use VNC to control them
|
||||
[module ccidu1_V6]
|
||||
class=secop.simulation.SimDrivable
|
||||
class=frappy.simulation.SimDrivable
|
||||
.description=Needle valve
|
||||
.visibility=expert
|
||||
value.default=99
|
||||
value.datatype={"type":"double", "min":0, "max":100, "unit":"%%"}
|
||||
|
||||
[module ccidu1_V3]
|
||||
class=secop.simulation.SimWritable
|
||||
class=frappy.simulation.SimWritable
|
||||
.description=Dump Valve
|
||||
.visibility=expert
|
||||
value.default="OFF"
|
||||
|
||||