Rename from secop to frappy
debian/ is still missing, will follow in next commit. Fixes: #4626 Change-Id: Ia87c28c1c75b8402eedbfca47f888585a7881f44
This commit is contained in:

committed by
Enrico Faulhaber

parent
c1eb764b09
commit
7f166a5b8c
@ -11,7 +11,7 @@ bindto=0.0.0.0
|
||||
bindport=10767
|
||||
|
||||
[module T_cci3he1]
|
||||
class=secop.simulation.SimDrivable
|
||||
class=frappy.simulation.SimDrivable
|
||||
.description=Main temperature control node of cci3he1.
|
||||
.
|
||||
Controls the regulation loop of the ls370.
|
||||
@ -26,7 +26,7 @@ ramp.default=60
|
||||
.meaning=["temperature_regulation",40]
|
||||
|
||||
[module T_cci3he1_A]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=3He pot temperature sensor. Also used for the regulation.
|
||||
.visibility=expert
|
||||
value.default=300
|
||||
@ -34,7 +34,7 @@ value.datatype={"type":"double","unit":"K"}
|
||||
.meaning=["temperature",38]
|
||||
|
||||
[module T_cci3he1_B]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=(optional) sample temperature sensor close to sample.
|
||||
.visibility=user
|
||||
value.default=300
|
||||
@ -42,49 +42,49 @@ value.datatype={"type":"double","unit":"K"}
|
||||
.meaning=["temperature",39]
|
||||
|
||||
[module cci3he1_p1]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=Pressure at turbo pump inlet.
|
||||
.visibility=expert
|
||||
value.default=2e-3
|
||||
value.datatype={"type":"double","unit":"mbar"}
|
||||
|
||||
[module cci3he1_p2]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=Pressure at turbo pump outlet.
|
||||
.visibility=expert
|
||||
value.default=9.87
|
||||
value.datatype={"type":"double","unit":"mbar"}
|
||||
|
||||
[module cci3he1_p3]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=Pressure at compressor inlet.
|
||||
.visibility=expert
|
||||
value.default=19.99
|
||||
value.datatype={"type":"double","unit":"mbar"}
|
||||
|
||||
[module cci3he1_p4]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=Pressure at compressor outlet.
|
||||
.visibility=expert
|
||||
value.default=999
|
||||
value.datatype={"type":"double","unit":"mbar"}
|
||||
|
||||
[module cci3he1_p5]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=Pressure in dump tank.
|
||||
.visibility=expert
|
||||
value.default=567
|
||||
value.datatype={"type":"double","unit":"mbar"}
|
||||
|
||||
[module cci3he1_p6]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=Pressure in the vacuum dewar (ivc).
|
||||
.visibility=expert
|
||||
value.default=1e-3
|
||||
value.datatype={"type":"double","unit":"mbar"}
|
||||
|
||||
[module cci3he1_flow]
|
||||
class=secop.simulation.SimReadable
|
||||
class=frappy.simulation.SimReadable
|
||||
.description=Gas Flow (condensing line).
|
||||
.visibility=expert
|
||||
value.default=12.34
|
||||
|
Reference in New Issue