View File

@ -54,37 +54,41 @@ Siehe auch diskussion im HZB-wiki hierzu....
verwirrend....
vorerst folgende Festlegung:
{"equipment_id": "cryo_7",
"firmware": "The SECoP playground",
"modules": ["cryo", {"commands": ["stop", {"resulttype": "None",
"arguments": "[]",
"description": "Testing command implementation\\n\\nwait a second"
},
"start", {"resulttype": "None",
"arguments": "[]",
"description": "normally does nothing,\\n\\nbut there may be modules which _start_ the action here\\n"
}
],
"group": "very important/stuff",
"implementation": "secop.devices.cryo.Cryostat",
"interfaces": ["Drivable", "Readable", "Device"],
"parameters": ["status", {"readonly": true,
"datatype": ["tuple", ["enum", {"unknown":-1,"idle":100, "warn":200, "unstable":250, "busy":300,"error":400}], "string"],
"description": "current status of the device"
},
"value", {"readonly": true,
"datatype": ["double",0,null],
"description": "regulation temperature",
"unit": "K"
},
"target", {"readonly": false,
"datatype": ["double",0,null],
"description": "target temperature",
"unit": "K"
}
]
}
],
"version": "2017.01"
}
.. code-block:: json
{"equipment_id": "cryo_7",
"firmware": "The SECoP playground",
"modules": ["cryo", {"commands": ["stop", {"resulttype": "None",
"arguments": "[]",
"description": "Testing command implementation\\n\\nwait a second"
},
"start", {"resulttype": "None",
"arguments": "[]",
"description": "normally does nothing,\\n\\nbut there may be modules which _start_ the action here\\n"
}
],
"group": "very important/stuff",
"implementation": "secop.devices.cryo.Cryostat",
"interfaces": ["Drivable", "Readable", "Device"],
"parameters": ["status", {"readonly": true,
"datatype": ["tuple", ["enum", {"unknown":-1,"idle":100, "warn":200, "unstable":250, "busy":300,"error":400}], "string"],
"description": "current status of the device"
},
"value", {"readonly": true,
"datatype": ["double",0,null],
"description": "regulation temperature",
"unit": "K"
},
"target", {"readonly": false,
"datatype": ["double",0,null],
"description": "target temperature",
"unit": "K"
}
]
}
],
"version": "2017.01"
}