ultrasound: change control roi0 to a Readable
+ remove cfg/PEUS.py + fix equipment_id of PEUS
This commit is contained in:
@ -85,14 +85,15 @@ class Roi(Readable):
|
||||
|
||||
class ControlRoi(Roi, Writable):
|
||||
freq = Attached()
|
||||
target = Parameter(datatype=Roi.value.datatype)
|
||||
# target is not releavnt -> always moving to I to zero
|
||||
target = Parameter(datatype=Roi.value.datatype, export=False)
|
||||
maxstep = Parameter('max frequency step', FloatRange(unit='Hz'), readonly=False,
|
||||
default=10000)
|
||||
minstep = Parameter('min frequency step for slope calculation', FloatRange(unit='Hz'),
|
||||
readonly=False, default=4000)
|
||||
slope = Parameter('inphase/frequency slope', FloatRange(), readonly=False,
|
||||
default=1e6)
|
||||
control_active = Parameter('are we controlling?', BoolType(), readonly=False)
|
||||
control_active = Parameter('are we controlling?', BoolType(), readonly=False, default=0)
|
||||
|
||||
_freq_target = None
|
||||
_skipctrl = 2
|
||||
@ -263,7 +264,6 @@ class PulseEcho(Base, Readable):
|
||||
value = Parameter(default=0)
|
||||
nr = Parameter('number of records', datatype=IntRange(1, 9999), default=500)
|
||||
bw = Parameter('bandwidth lowpassfilter', datatype=FloatRange(unit='Hz'), default=10E6)
|
||||
control = Parameter('control loop on?', BoolType(), readonly=False, default=True)
|
||||
time = Parameter('pulse start time', FloatRange(unit='nsec'),
|
||||
readonly=False)
|
||||
size = Parameter('pulse length (starting from time)', FloatRange(unit='nsec'),
|
||||
|
Reference in New Issue