add comment "do not use mb11stick"

This commit is contained in:
2022-10-18 16:41:04 +02:00
parent 971c1dcfee
commit 0c93ca8c75

View File

@ -1,16 +1,19 @@
[NODE] # DO NOT USE
description = MB11 standard sample stick # use 'mb11std' instead of 'mb11', 'mb11stick'
id = mb11.stick.sea.psi.ch # as the communication proxy for itc does not work yet
[NODE]
description = MB11 standard sample stick (do not use)
id = mb11.stick.sea.psi.ch
[INTERFACE] [INTERFACE]
uri = tcp://5000 uri = tcp://5000
[itc] #[itc]
class = secop.proxy.Proxy #class = secop.proxy.Proxy
remote_class = secop_psi.mercury.IO #remote_class = secop_psi.mercury.IO
description = connection to MB11 mercury #description = connection to MB11 mercury
module = itc1 #module = itc1
#uri = mb11-ts:3001 #uri = mb11-ts:3001
#timeout = 5 #timeout = 5
@ -25,19 +28,17 @@ module = itc1
#calib = /home/l_samenv/sea/tcl/calcurves/X70197.340 #calib = /home/l_samenv/sea/tcl/calcurves/X70197.340
#svalue.unit = K #svalue.unit = K
#[ts]
#class = secop.proxy.Proxy
#remote_class = secop_psi.mercury.TemperatureLoop
#description = sample temperature
#module = T_sample
#io = itc1
#[htr_ts]
#class = secop.proxy.Proxy
#remote_class = secop_psi.mercury.HeaterOutput
#description = sample stick heater power
#module = htr_sample
#io = itc1
[ts]
class = secop_psi.mercury.TemperatureLoop
description = sample temperature
output_module = htr_ts
slot = MB1.T1
io = itc
tolerance = 1
[htr_ts]
class = secop_psi.mercury.HeaterOutput
description = sample stick heater power
slot = MB0.H1
io = itc