From 50fa769d508ea0a067b4bd8987628df9187ea7b2 Mon Sep 17 00:00:00 2001 From: Edward Wall Date: Wed, 5 Aug 2026 08:30:36 +0200 Subject: [PATCH] WAIT_HW having never been set shouldn't modify the system status --- db/daq_common.db | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) diff --git a/db/daq_common.db b/db/daq_common.db index 677a9af..b5e8bde 100644 --- a/db/daq_common.db +++ b/db/daq_common.db @@ -10,8 +10,8 @@ # PV Control Flow # --------------- # -# ┌───────────────────────────────────────────────────────────────────────────────────────┐ -# │ │ +# PVs with arrows starting with a ┌───────────────────────────────────────────────────────────────────────────────────────┐ +# 'o' can be directly written to │ │ # │ START │ # │ │ │ # │ ▼ │ @@ -267,7 +267,7 @@ record(calc, "$(INSTR)$(NAME):MAP_STATUS") field(INPD, "$(INSTR)$(NAME):COUNTING_PRESET PP MS") field(INPE, "$(INSTR)$(NAME):IS_LOWRATE PP MS") field(INPF, "$(INSTR)$(NAME):IS_PAUSED PP MS") - field(INPG, "$(INSTR)$(NAME):WAIT_HW NPP MS") + field(INPG, "$(INSTR)$(NAME):WAIT_HW NPP") field(CALC, "(A=1||B=1)?4:(F=1)?3:(C=0&&D=0&&G<=0)?0:(E=1)?2:1") field(FLNK, "$(INSTR)$(NAME):STATUS") }