Motor Record and related software
-
-
- Motor Record and related software
-
- Tim Mooney, Joe Sullivan, Ron Sluiter
-
-
-
- Contents
-
+
+
+
+Motor Record and related software
+
+Tim Mooney, Joe Sullivan, Ron Sluiter
+
+
+Contents
+
-
-
- Overview
- This documentation describes version 4.5 of the EPICS motor record, and
-related EPICS software required to build and use it. Version 4.5 of
-the motor record is compatible with EPICS base R3.13.6 and above.
-The motor record is intended to support motors of all kinds, but currently
- supports only the following variety of motor controllers (in addition to
-Soft Channel support):
-
+
+
+Overview
This documentation describes version 5.1 of the EPICS motor
+record, and related EPICS software required to build and use it. Version
+5.1 of the motor record is compatible with EPICS base R3.14.2 and above.
+
+The motor record is intended to support motors of all kinds, but currently
+supports only the following variety of motor controllers (in addition to Soft
+Channel support):
+
+
- - Oregon Micro Systems, Inc. (OMS) models; VME8, VME44, VME58 and VS4.
- - Highland Technologies model V540.
- - Newport models MM3000, MM4000, MM4005 and PM500.
- - Intelligent Motion Systems, Inc. (IMS) model IM483.
- - Advanced Control Systems, Corp. model MCB-4B
- - Mclennan model PM304
-
+ -
+ Oregon Micro Systems, Inc. (OMS) models; VME8, VME44, VME58 and VS4.
+
+ -
+ Highland Technologies model V540.
+
+ -
+ Newport models MM3000, MM4000, MM4005, PM500 and ESP300.
+
+ -
+ Intelligent Motion Systems, Inc. (IMS) model IM483.
+
+ -
+ Advanced Control Systems, Corp. model MCB-4B.
+
+ -
+ Mclennan model PM304 and PM600.
+
- The record maintains two coordinate systems for motor position ("user"
-and "dial" coordinates); displays drive and readback values; enforces limits
-to motor motion and maintains those limits in both coordinate systems; displays
-the states of limit switches; can use a home switch; optionally takes out
-backlash in a user-defined direction; and provides a mechanism by which the
-user and other EPICS records can recalibrate the motor position in either
-coordinate system. The record also supports "tweak", "jog", and "home" motions,
-and supports both absolute and relative motions in user coordinates. Two "stop"
-switches are provided: a simple one for use by other records and by channel-access
-clients, and a more versatile one for interactive use.
-Except where specified otherwise, fields associated with the motor position
- and its derivatives take values in user-specified "engineering units", such
-as degrees; the engineering unit name is contained in the field EGU. Thus,
-generally, speeds are expressed in EGU's per second. Accelerations, however,
-are expressed as the number of seconds taken to accelerate to full speed.
-However, additional fields are provided so that the motor position can be
-specified in steps and the speed in revolutions per second, and so that the
-step size can be set by specifying the number of steps per revolution and
-the number of EGU's per revolution.
-
-The motor record can read motor position from the controller's readback
- register or encoder register, or from any other EPICS record, via an EPICS
- input link. While the motor is moving, the record can trigger an output
-link periodically, to send readback information to other EPICS records. When
-a complete motion (possibly including backlash takeout) is finished, the
-record can trigger a forward link to process other EPICS records.
-
-The motor record can force its drive fields to agree with its readback
- fields, and it does so in a variety of circumstances (e.g., when the user
- tells a motor to stop, and when a limit switch is hit). Therefore, if you
- are driving the motor record's VAL or DVAL field with the output of another
- record, and you want that record always to contain the same value as the
-motor record, you must handle this behavior in the database. One way to do
-this is to forward link the motor record to a soft analog output record,
-and to cause that AO record to grab the motor record's VAL or DVAL field
-and poke it into your record.
-
-The motor record is unlike most other EPICS records in that its processing
- is neither "synchronous" nor "asynchronous", as these terms are used in
-the EPICS Record Reference Manual. Currently, the PACT field is always FALSE
-after record processing has completed, even though a motor motion may be in
-progress. This means the record always responds to channel-access puts, and
-can be stopped or retargeted at any time. The record's forward link is not
-executed until the motor has stopped and no motion requests are pending.
-
-
- Field Descriptions
- In addition to fields common to all record types (see the
- EPICS Record Reference Manual
- for these) the motor record has the fields described below.
+The record maintains two coordinate systems for motor position ("user" and "dial
+" coordinates); displays drive and readback values; enforces limits to motor
+motion and maintains those limits in both coordinate systems; displays the
+states of limit switches; can use a home switch; optionally takes out backlash
+in a user-defined direction; and provides a mechanism by which the user and
+other EPICS records can recalibrate the motor position in either coordinate
+system. The record also supports "tweak", "jog", and "home" motions, and
+supports both absolute and relative motions in user coordinates. Two "stop"
+switches are provided: a simple one for use by other records and by channel-access
+clients, and a more versatile one for interactive use.
+
+Except where specified otherwise, fields associated with the motor position and
+its derivatives take values in user-specified "engineering units", such as
+degrees; the engineering unit name is contained in the field EGU. Thus,
+generally, speeds are expressed in EGU's per second. Accelerations, however, are
+expressed as the number of seconds taken to accelerate to full speed. However,
+additional fields are provided so that the motor position can be specified in
+steps and the speed in revolutions per second, and so that the step size can be
+set by specifying the number of steps per revolution and the number of EGU's per
+revolution.
+
+
+
+The motor record can read motor position from the controller's readback register
+or encoder register, or from any other EPICS record, via an EPICS input link.
+While the motor is moving, the record can trigger an output link periodically,
+to send readback information to other EPICS records. When a complete motion (possibly
+including backlash takeout) is finished, the record can trigger a forward link
+to process other EPICS records.
+
+
+
+The motor record can force its drive fields to agree with its readback fields,
+and it does so in a variety of circumstances (e.g., when the user tells a motor
+to stop, and when a limit switch is hit). Therefore, if you are driving the
+motor record's VAL or DVAL field with the output of another record, and you want
+that record always to contain the same value as the motor record, you must
+handle this behavior in the database. One way to do this is to forward link the
+motor record to a soft analog output record, and to cause that AO record to grab
+the motor record's VAL or DVAL field and poke it into your record.
+
+
+
+The motor record is unlike most other EPICS records in that its processing is
+neither "synchronous" nor "asynchronous", as these terms are used in the EPICS
+Record Reference Manual. Currently, the PACT field is always FALSE after record
+processing has completed, even though a motor motion may be in progress. This
+means the record always responds to channel-access puts, and can be stopped or
+retargeted at any time. The record's forward link is not executed until the
+motor has stopped and no motion requests are pending.
+
+
+Field Descriptions
In addition to fields common to all record types (see
+the EPICS
+Record Reference Manual for these) the motor record has the fields described
+below.
-
-
+
+
-
-
- Alphabetical list of record-specific fields
- NOTE: Hot links in this table take you only to the section in which
- the linked item is described in detail. You'll probably have to scroll down
-to find the actual item.
-
- | Name |
- Access |
- Prompt |
- Data type |
- Comment |
-
-
- | ACCL
- |
- R/W |
- Seconds to Velocity |
- FLOAT |
- acceleration time |
-
-
- | ATHM
- |
- R |
- At HOME |
- SHORT |
- uses the HOME switch |
-
-
- | BACC
- |
- R/W |
- BL Seconds to Veloc. |
- FLOAT |
- backlash acceleration time |
-
-
- | BDST
- |
- R/W |
- BL Distance (EGU) |
- FLOAT |
- backlash distance |
-
-
- | BVEL
- |
- R/W |
- BL Velocity (EGU/s) |
- FLOAT |
- backlash speed |
-
-
- | CARD
- |
- R |
- Card Number |
- SHORT |
- EPICS card # |
-
-
- | CBAK
- |
- None |
- Callback structure |
- NOACCESS |
-
- |
-
-
- CDIR
-
- |
- R
- |
- Command direction
- |
- SHORT
- |
-
- |
-
-
- | CNEN
- |
- R/W |
- Enable control |
- RECCHOICE |
- (0:"Disable", 1:"Enable") |
-
-
- | DCOF
- |
- R/W |
- Derivative Gain |
- FLOAT |
-
- |
-
-
- | DHLM
- |
- R/W* |
- Dial High Limit |
- FLOAT |
-
- |
-
-
- | DIFF
- |
- R |
- Difference dval-drbv |
- DOUBLE |
-
- |
-
-
- | DINP
- |
- R/W |
- DMOV Input Link |
- INLINK |
-
- |
-
-
- | DIR
- |
- R/W* |
- User Direction |
- RECCHOICE |
- (0:"Pos", 1:"Neg") |
-
-
- | DLLM
- |
- R/W* |
- Dial Low Limit |
- FLOAT |
-
- |
-
-
- | DLY
- |
- R/W |
- Readback settle time (s) |
- FLOAT |
-
- |
-
-
- | DMOV
- |
- R |
- Done moving to value |
- SHORT |
- The "done" flag |
-
-
- | DOL
- |
- R |
- Desired Output Loc |
- INLINK |
- only for closed-loop mode |
-
-
- | DRBV
- |
- R |
- Dial Readback Value |
- DOUBLE |
-
- |
-
-
- | DVAL
- |
- R/W* |
- Dial Desired Value |
- DOUBLE |
-
- |
-
-
- | EGU
- |
- R/W |
- Engineering Units |
- STRING |
-
- |
-
-
- | ERES
- |
- R/W* |
- Encoder Step Size (EGU) |
- FLOAT |
-
- |
-
-
- | FOF
- |
- R/W |
- Freeze Offset |
- SHORT |
-
- |
-
-
- | FOFF
- |
- R/W |
- Offset-Freeze Switch |
- RECCHOICE |
- (0:"Variable", 1:"Frozen") |
-
-
- | FRAC
- |
- R/W |
- Move Fraction |
- FLOAT |
-
- |
-
-
- | HHSV
- |
- R/W* |
- Hihi Severity |
- GBLCHOICE |
-
-
- | HIGH
- |
- R/W* |
- High Alarm Limit |
- FLOAT |
-
- |
-
-
- | HIHI
- |
- R/W* |
- Hihi Alarm Limit |
- FLOAT |
-
- |
-
-
- | HLM
- |
- R/W* |
- User High Limit |
- FLOAT |
-
- |
-
-
- | HLS
- |
- R |
- At High Limit Switch |
- SHORT |
-
- |
-
-
- | HLSV
- |
- R/W* |
- HW Lim. Violation Svr |
- GBLCHOICE |
-
- |
-
-
- | HOMF
- |
- R/W* |
- Home Forward |
- SHORT |
-
- |
-
-
- | HOMR
- |
- R/W* |
- Home Reverse |
- SHORT |
-
- |
-
-
- | HOPR
- |
- R/W |
- High Operating Range |
- FLOAT |
-
- |
-
-
- | HSV
- |
- R/W* |
- High Severity |
- GBLCHOICE |
-
- |
-
-
- | ICOF
- |
- R/W |
- Integral Gain |
- FLOAT |
-
- |
-
-
- | INIT
- |
- R/W |
- Startup commands |
- STRING |
-
- |
-
-
- | JAR
- |
- R/W |
- Jog Acceleration (EGU/s^2) |
- FLOAT |
-
- |
-
-
- | JOGF
- |
- R/W* |
- Jog motor Forward |
- SHORT |
- careful! |
-
-
- | JOGR
- |
- R/W* |
- Jog motor Reverse |
- SHORT |
- careful! |
-
-
- | JVEL
- |
- R/W |
- Jog Velocity |
- FLOAT |
-
- |
-
-
- | LDVL
- |
- R |
- Last Dial Des Val |
- DOUBLE |
-
- |
-
-
- | LLM
- |
- R/W* |
- User Low Limit |
- FLOAT |
-
- |
-
-
- | LLS
- |
- R |
- At Low Limit Switch |
- SHORT |
-
- |
-
-
- | LLSV
- |
- R/W* |
- Lolo Severity |
- GBLCHOICE |
-
- |
-
-
- | LOLO
- |
- R/W* |
- Lolo Alarm Limit |
- FLOAT |
-
- |
-
-
- | LOPR
- |
- R/W |
- Low Operating Range |
- FLOAT |
-
- |
-
-
- | LOW
- |
- R/W* |
- Low Alarm Limit |
- FLOAT |
-
- |
-
-
- | LRLV
- |
- R |
- Last Rel Value |
- DOUBLE |
-
- |
-
-
- | LRVL
- |
- R |
- Last Raw Des Val |
- DOUBLE |
-
- |
-
-
- | LSPG
- |
- R |
- Last SPMG |
- RECCHOICE |
- (See SPMG) |
-
-
- | LSV
- |
- R/W* |
- Low Severity |
- GBLCHOICE |
-
- |
-
-
- | LVAL
- |
- R |
- Last User Des Val |
- DOUBLE |
-
- |
-
-
- | LVIO
- |
- R |
- Limit violation |
- SHORT |
-
- |
-
-
- | MIP
- |
- R |
- Motion In Progress |
- SHORT |
-
- |
-
-
- | MISS
- |
- R |
- Ran out of retries |
- SHORT |
-
- |
-
-
- | MMAP
- |
- R |
- Monitor Mask |
- ULONG |
-
- |
-
-
- | MOVN
- |
- R |
- Motor is moving |
- SHORT |
- Don't confuse with DMOV |
-
-
- | MRES
- |
- R/W* |
- Motor Step Size (EGU) |
- FLOAT |
-
- |
-
-
- | MSTA
- |
- R |
- Motor Status |
- ULONG |
-
- |
-
-
- | NMAP
- |
- R |
- Monitor Mask |
- ULONG |
-
- |
-
-
- | OFF
- |
- R/W |
- User Offset (EGU) |
- DOUBLE |
-
- |
-
-
- | OMSL
- |
- R/W |
- Output Mode Select |
- GBLCHOICE |
-
- |
-
-
- | OUT
- |
- R/W |
- Output Specification |
- OUTLINK |
-
- |
-
-
- | PCOF
- |
- R/W |
- Proportional Gain |
- FLOAT |
-
- |
-
-
- | PERL
- |
- R/W |
- Periodic Limits |
- RECCHOICE |
- (0:"No", 1:"Yes") |
-
-
- | POST
- |
- R/W |
- Post-move commands |
- STRING |
-
- |
-
-
- | PP
- |
- R |
- Post process command |
- SHORT |
-
- |
-
-
- | PREC
- |
- R/W |
- Display Precision |
- SHORT |
-
- |
-
-
- | PREM
- |
- R/W |
- Pre-move commands |
- STRING |
-
- |
-
-
- | RBV
- |
- R |
- User Readback Value |
- DOUBLE |
-
- |
-
-
- | RCNT
- |
- R |
- Retry count |
- SHORT |
-
- |
-
-
- | RDBD
- |
- R/W |
- Retry Deadband (EGU) |
- FLOAT |
-
- |
-
-
- | RDBL
- |
- R |
- Readback Location |
- INLINK |
-
- |
-
-
- | RDIF
- |
- R |
- Difference rval-rrbv |
- LONG |
-
- |
-
-
- | REP
- |
- R |
- Raw Encoder Position |
- DOUBLE |
-
- |
-
-
- | RHLS
- |
- R |
- Raw High Limit Switch |
- SHORT |
-
- |
-
-
- | RINP
- |
- R/W |
- RMP Input Link |
- INLINK |
-
- |
-
-
- | RLLS
- |
- R |
- Raw Low Limit Switch |
- SHORT |
-
- |
-
-
- | RLNK
- |
- R |
- Readback OutLink |
- OUTLINK |
-
- |
-
-
- | RLV
- |
- R/W* |
- Relative Value |
- DOUBLE |
-
- |
-
-
- | RMP
- |
- R |
- Raw Motor Position |
- DOUBLE |
-
- |
-
-
- | RRBV
- |
- R |
- Raw Readback Value |
- DOUBLE |
-
- |
-
-
- | RRES
- |
- R/W |
- Readback Step Size (EGU) |
- FLOAT |
-
- |
-
-
- | RTRY
- |
- R/W |
- Max retry count |
- SHORT |
-
- |
-
-
- | RVAL
- |
- R/W* |
- Raw Desired Value |
- DOUBLE |
-
- |
-
-
- | RVEL
- |
- R |
- Raw Velocity |
- LONG |
-
- |
-
-
- | S
- |
- R/W |
- Speed (RPS) |
- FLOAT |
-
- |
-
-
- | SBAK
- |
- R/W |
- BL Speed (RPS) |
- FLOAT |
-
- |
-
-
- | SBAS
- |
- R/W |
- Base Speed (RPS) |
- FLOAT |
-
- |
-
-
- | SET
- |
- R/W |
- Set/Use Switch |
- RECCHOICE |
- (0:"Use", 1:"Set") |
-
-
- | SMAX
- |
- R/W |
- Max Velocity (RPS) |
- FLOAT |
-
- |
-
-
- | SPMG
- |
- R/W* |
- Stop/Pause/Move/Go |
- RECCHOICE |
- (0:"Stop", 1:"Pause", 2:"Move", 3:"Go") |
-
-
- | SREV
- |
- R/W* |
- Steps per Revolution |
- LONG |
-
- |
-
-
- | SSET
- |
- R/W |
- Set SET Mode |
- SHORT |
-
- |
-
-
- | STOO
- |
- R/W |
- STOP OutLink |
- OUTLINK |
-
- |
-
-
- | STOP
- |
- R/W* |
- Stop |
- SHORT |
-
- |
-
-
- | SUSE
- |
- R/W |
- Set USE Mode |
- SHORT |
-
- |
-
-
- | TDIR
- |
- R |
- Direction of Travel |
- SHORT |
-
- |
-
-
- | TWF
- |
- R/W* |
- Tweak motor Forward |
- SHORT |
-
- |
-
-
- | TWR
- |
- R/W* |
- Tweak motor Reverse |
- SHORT |
-
- |
-
-
- | TWV
- |
- R/W* |
- Tweak Step Size (EGU) |
- FLOAT |
-
- |
-
-
- | UEIP
- |
- R/W* |
- Use Encoder If Present |
- RECCHOICE |
- (0:"No", 1:"Yes") |
-
-
- | UREV
- |
- R/W* |
- EGU's per Revolution |
- FLOAT |
-
- |
-
-
- | URIP
- |
- R/W* |
- Use RDBL Link If Present |
- RECCHOICE |
- (0:"No", 1:"Yes") |
-
-
- | VAL
- |
- R/W* |
- User Desired Value |
- DOUBLE |
-
- |
-
-
- | VBAS
- |
- R/W |
- Base Velocity (EGU/s) |
- FLOAT |
-
- |
-
-
- | VELO
- |
- R/W |
- Velocity (EGU/s) |
- FLOAT |
-
- |
-
-
- | VERS
- |
- R |
- Code Version |
- FLOAT |
- e.g., "1.95" |
-
-
- | VMAX
- |
- R/W |
- Max Velocity (EGU/s) |
- FLOAT |
-
- |
-
-
- | VOF
- |
- R/W |
- Variable Offset |
- SHORT |
-
- |
-
-
-
+
+
+
+ Alphabetical list of record-specific fields NOTE: Hot links in this
+ table take you only to the section in which the linked item is described
+ in detail. You'll probably have to scroll down to find the actual item.
+
+ |
+
+
+ | Name |
+ Access |
+ Prompt |
+ Data type |
+ Comment |
+
+
+
+ | ACCL |
+ R/W |
+ Seconds to Velocity |
+ FLOAT |
+ acceleration time |
+
+
+
+ | ATHM |
+ R |
+ At HOME |
+ SHORT |
+ uses the HOME switch |
+
+
+
+ | BACC |
+ R/W |
+ BL Seconds to Veloc. |
+ FLOAT |
+ backlash acceleration time |
+
+
+
+ | BDST |
+ R/W |
+ BL Distance (EGU) |
+ FLOAT |
+ backlash distance |
+
+
+
+ | BVEL |
+ R/W |
+ BL Velocity (EGU/s) |
+ FLOAT |
+ backlash speed |
+
+
+
+ | CARD |
+ R |
+ Card Number |
+ SHORT |
+ EPICS card # |
+
+
+
+ | CBAK |
+ None |
+ Callback structure |
+ NOACCESS |
+
+ |
+
+
+
+ | CDIR |
+ R |
+ Command direction |
+ SHORT |
+
+ |
+
+
+
+ | CNEN |
+ R/W |
+ Enable control |
+ RECCHOICE |
+ (0:"Disable", 1:"Enable") |
+
+
+
+ | DCOF |
+ R/W |
+ Derivative Gain |
+ FLOAT |
+
+ |
+
+
+
+ | DHLM |
+ R/W* |
+ Dial High Limit |
+ FLOAT |
+
+ |
+
+
+
+ | DIFF |
+ R |
+ Difference dval-drbv |
+ DOUBLE |
+
+ |
+
+
+
+ | DINP |
+ R/W |
+ DMOV Input Link |
+ INLINK |
+
+ |
+
+
+
+ | DIR |
+ R/W* |
+ User Direction |
+ RECCHOICE |
+ (0:"Pos", 1:"Neg") |
+
+
+
+ | DLLM |
+ R/W* |
+ Dial Low Limit |
+ FLOAT |
+
+ |
+
+
+
+ | DLY |
+ R/W |
+ Readback settle time (s) |
+ FLOAT |
+
+ |
+
+
+
+ | DMOV |
+ R |
+ Done moving to value |
+ SHORT |
+ The "done" flag |
+
+
+
+ | DOL |
+ R |
+ Desired Output Loc |
+ INLINK |
+ only for closed-loop mode |
+
+
+
+ | DRBV |
+ R |
+ Dial Readback Value |
+ DOUBLE |
+
+ |
+
+
+
+ | DVAL |
+ R/W* |
+ Dial Desired Value |
+ DOUBLE |
+
+ |
+
+
+
+ | EGU |
+ R/W |
+ Engineering Units |
+ STRING |
+
+ |
+
+
+
+ | ERES |
+ R/W* |
+ Encoder Step Size (EGU) |
+ FLOAT |
+
+ |
+
+
+
+ | FOF |
+ R/W |
+ Freeze Offset |
+ SHORT |
+
+ |
+
+
+
+ | FOFF |
+ R/W |
+ Offset-Freeze Switch |
+ RECCHOICE |
+ (0:"Variable", 1:"Frozen") |
+
+
+
+ | FRAC |
+ R/W |
+ Move Fraction |
+ FLOAT |
+
+ |
+
+
+
+ | HHSV |
+ R/W* |
+ Hihi Severity |
+ GBLCHOICE |
+
+ |
+
+
+
+ | HIGH |
+ R/W* |
+ High Alarm Limit |
+ FLOAT |
+
+ |
+
+
+
+ | HIHI |
+ R/W* |
+ Hihi Alarm Limit |
+ FLOAT |
+
+ |
+
+
+
+ | HLM |
+ R/W* |
+ User High Limit |
+ FLOAT |
+
+ |
+
+
+
+ | HLS |
+ R |
+ At High Limit Switch |
+ SHORT |
+
+ |
+
+
+
+ | HLSV |
+ R/W* |
+ HW Lim. Violation Svr |
+ GBLCHOICE |
+
+ |
+
+
+
+ | HOMF |
+ R/W* |
+ Home Forward |
+ SHORT |
+
+ |
+
+
+
+ | HOMR |
+ R/W* |
+ Home Reverse |
+ SHORT |
+
+ |
+
+
+
+ | HOPR |
+ R/W |
+ High Operating Range |
+ FLOAT |
+
+ |
+
+
+
+ | HSV |
+ R/W* |
+ High Severity |
+ GBLCHOICE |
+
+ |
+
+
+
+ | HVEL |
+ R/W* |
+ Home Velocity |
+ FLOAT |
+
+ |
+
+
+
+ | ICOF |
+ R/W |
+ Integral Gain |
+ FLOAT |
+
+ |
+
+
+
+ | INIT |
+ R/W |
+ Startup commands |
+ STRING |
+
+ |
+
+
+
+ | JAR |
+ R/W |
+ Jog Acceleration (EGU/s^2) |
+ FLOAT |
+
+ |
+
+
+
+ | JOGF |
+ R/W* |
+ Jog motor Forward |
+ SHORT |
+ careful! |
+
+
+
+ | JOGR |
+ R/W* |
+ Jog motor Reverse |
+ SHORT |
+ careful! |
+
+
+
+ | JVEL |
+ R/W |
+ Jog Velocity |
+ FLOAT |
+
+ |
+
+
+
+ | LDVL |
+ R |
+ Last Dial Des Val |
+ DOUBLE |
+
+ |
+
+
+
+ | LLM |
+ R/W* |
+ User Low Limit |
+ FLOAT |
+
+ |
+
+
+
+ | LLS |
+ R |
+ At Low Limit Switch |
+ SHORT |
+
+ |
+
+
+
+ | LLSV |
+ R/W* |
+ Lolo Severity |
+ GBLCHOICE |
+
+ |
+
+
+
+ | LOCK |
+ R/W* |
+ Soft Channel Position Lock |
+ RECCHOICE |
+ (0:"No", 1:"Yes") |
+
+
+
+ | LOLO |
+ R/W* |
+ Lolo Alarm Limit |
+ FLOAT |
+
+ |
+
+
+
+ | LOPR |
+ R/W |
+ Low Operating Range |
+ FLOAT |
+
+ |
+
+
+
+ | LOW |
+ R/W* |
+ Low Alarm Limit |
+ FLOAT |
+
+ |
+
+
+
+ | LRLV |
+ R |
+ Last Rel Value |
+ DOUBLE |
+
+ |
+
+
+
+ | LRVL |
+ R |
+ Last Raw Des Val |
+ DOUBLE |
+
+ |
+
+
+
+ | LSPG |
+ R |
+ Last SPMG |
+ RECCHOICE |
+ (See SPMG) |
+
+
+
+ | LSV |
+ R/W* |
+ Low Severity |
+ GBLCHOICE |
+
+ |
+
+
+
+ | LVAL |
+ R |
+ Last User Des Val |
+ DOUBLE |
+
+ |
+
+
+
+ | LVIO |
+ R |
+ Limit violation |
+ SHORT |
+
+ |
+
+
+
+ | MIP |
+ R |
+ Motion In Progress |
+ SHORT |
+
+ |
+
+
+
+ | MISS |
+ R |
+ Ran out of retries |
+ SHORT |
+
+ |
+
+
+
+ | MMAP |
+ R |
+ Monitor Mask |
+ ULONG |
+
+ |
+
+
+
+ | MOVN |
+ R |
+ Motor is moving |
+ SHORT |
+ Don't confuse with DMOV |
+
+
+
+ | MRES |
+ R/W* |
+ Motor Step Size (EGU) |
+ FLOAT |
+
+ |
+
+
+
+ | MSTA |
+ R |
+ Motor Status |
+ ULONG |
+
+ |
+
+
+
+ | NMAP |
+ R |
+ Monitor Mask |
+ ULONG |
+
+ |
+
+
+
+ | NTM |
+ R/W* |
+ New Target Monitor |
+ RECCHOICE |
+ (0:"No", 1:"Yes") |
+
+
+
+ | OFF |
+ R/W |
+ User Offset (EGU) |
+ DOUBLE |
+
+ |
+
+
+
+ | OMSL |
+ R/W |
+ Output Mode Select |
+ GBLCHOICE |
+
+ |
+
+
+
+ | OUT |
+ R/W |
+ Output Specification |
+ OUTLINK |
+
+ |
+
+
+
+ | PCOF |
+ R/W |
+ Proportional Gain |
+ FLOAT |
+
+ |
+
+
+
+ | PERL |
+ R/W |
+ Periodic Limits |
+ RECCHOICE |
+ (0:"No", 1:"Yes") |
+
+
+
+ | POST |
+ R/W |
+ Post-move commands |
+ STRING |
+
+ |
+
+
+
+ | PP |
+ R |
+ Post process command |
+ SHORT |
+
+ |
+
+
+
+ | PREC |
+ R/W |
+ Display Precision |
+ SHORT |
+
+ |
+
+
+
+ | PREM |
+ R/W |
+ Pre-move commands |
+ STRING |
+
+ |
+
+
+
+ | RBV |
+ R |
+ User Readback Value |
+ DOUBLE |
+
+ |
+
+
+
+ | RCNT |
+ R |
+ Retry count |
+ SHORT |
+
+ |
+
+
+
+ | RDBD |
+ R/W |
+ Retry Deadband (EGU) |
+ FLOAT |
+
+ |
+
+
+
+ | RDBL |
+ R |
+ Readback Location |
+ INLINK |
+
+ |
+
+
+
+ | RDIF |
+ R |
+ Difference rval-rrbv |
+ LONG |
+
+ |
+
+
+
+ | REP |
+ R |
+ Raw Encoder Position |
+ DOUBLE |
+
+ |
+
+
+
+ | RHLS |
+ R |
+ Raw High Limit Switch |
+ SHORT |
+
+ |
+
+
+
+ | RINP |
+ R/W |
+ RMP Input Link |
+ INLINK |
+
+ |
+
+
+
+ | RLLS |
+ R |
+ Raw Low Limit Switch |
+ SHORT |
+
+ |
+
+
+
+ | RLNK |
+ R |
+ Readback OutLink |
+ OUTLINK |
+
+ |
+
+
+
+ | RLV |
+ R/W* |
+ Relative Value |
+ DOUBLE |
+
+ |
+
+
+
+ | RMP |
+ R |
+ Raw Motor Position |
+ DOUBLE |
+
+ |
+
+
+
+ | RRBV |
+ R |
+ Raw Readback Value |
+ DOUBLE |
+
+ |
+
+
+
+ | RRES |
+ R/W |
+ Readback Step Size (EGU) |
+ FLOAT |
+
+ |
+
+
+
+ | RTRY |
+ R/W |
+ Max retry count |
+ SHORT |
+
+ |
+
+
+
+ | RVAL |
+ R/W* |
+ Raw Desired Value |
+ DOUBLE |
+
+ |
+
+
+
+ | RVEL |
+ R |
+ Raw Velocity |
+ LONG |
+
+ |
+
+
+
+ | S |
+ R/W |
+ Speed (RPS) |
+ FLOAT |
+
+ |
+
+
+
+ | SBAK |
+ R/W |
+ BL Speed (RPS) |
+ FLOAT |
+
+ |
+
+
+
+ | SBAS |
+ R/W |
+ Base Speed (RPS) |
+ FLOAT |
+
+ |
+
+
+
+ | SET |
+ R/W |
+ Set/Use Switch |
+ RECCHOICE |
+ (0:"Use", 1:"Set") |
+
+
+
+ | SMAX |
+ R/W |
+ Max Velocity (RPS) |
+ FLOAT |
+
+ |
+
+
+
+ | SPMG |
+ R/W* |
+ Stop/Pause/Move/Go |
+ RECCHOICE |
+ (0:"Stop", 1:"Pause", 2:"Move", 3:"Go") |
+
+
+
+ | SREV |
+ R/W* |
+ Steps per Revolution |
+ LONG |
+
+ |
+
+
+
+ | SSET |
+ R/W |
+ Set SET Mode |
+ SHORT |
+
+ |
+
+
+
+ | STOO |
+ R/W |
+ STOP OutLink |
+ OUTLINK |
+
+ |
+
+
+
+ | STOP |
+ R/W* |
+ Stop |
+ SHORT |
+
+ |
+
+
+
+ | SUSE |
+ R/W |
+ Set USE Mode |
+ SHORT |
+
+ |
+
+
+
+ | TDIR |
+ R |
+ Direction of Travel |
+ SHORT |
+
+ |
+
+
+
+ | TWF |
+ R/W* |
+ Tweak motor Forward |
+ SHORT |
+
+ |
+
+
+
+ | TWR |
+ R/W* |
+ Tweak motor Reverse |
+ SHORT |
+
+ |
+
+
+
+ | TWV |
+ R/W* |
+ Tweak Step Size (EGU) |
+ FLOAT |
+
+ |
+
+
+
+ | UEIP |
+ R/W* |
+ Use Encoder If Present |
+ RECCHOICE |
+ (0:"No", 1:"Yes") |
+
+
+
+ | UREV |
+ R/W* |
+ EGU's per Revolution |
+ FLOAT |
+
+ |
+
+
+
+ | URIP |
+ R/W* |
+ Use RDBL Link If Present |
+ RECCHOICE |
+ (0:"No", 1:"Yes") |
+
+
+
+ | VAL |
+ R/W* |
+ User Desired Value |
+ DOUBLE |
+
+ |
+
+
+
+ | VBAS |
+ R/W |
+ Base Velocity (EGU/s) |
+ FLOAT |
+
+ |
+
+
+
+ | VELO |
+ R/W |
+ Velocity (EGU/s) |
+ FLOAT |
+
+ |
+
+
+
+ | VERS |
+ R |
+ Code Version |
+ FLOAT |
+ e.g., "1.95" |
+
+
+
+ | VMAX |
+ R/W |
+ Max Velocity (EGU/s) |
+ FLOAT |
+
+ |
+
+
+
+ | VOF |
+ R/W |
+ Variable Offset |
+ SHORT |
+
+ |
+
+
+
+
-
-
- | Note: In the Access column above: |
-
-
- | R |
- Read only |
-
- |
-
-
- | R/W |
- Read and write are allowed |
-
-
- | R/W* |
- Read and write are allowed; write triggers record processing if the
- record's SCAN field is set to "Passive." |
-
-
- | N |
- No access allowed |
-
-
- | Note: In the Prompt column above: |
-
-
- | EGU |
- Engineering Units |
-
-
- | RPS |
- Revolutions Per Second |
-
-
-
+
+
+ | Note: In the Access column above: |
+
+
+ | R |
+ Read only |
+
+ |
+
+
+ | R/W |
+ Read and write are allowed |
+
+
+ | R/W* |
+ Read and write are allowed; write triggers record processing if the record's
+ SCAN field is set to "Passive." |
+
+
+ | N |
+ No access allowed |
+
+
+ | Note: In the Prompt column above: |
+
+
+ | EGU |
+ Engineering Units |
+
+
+ | RPS |
+ Revolutions Per Second |
+
+
- |
+
+
-
-
+
+
-
-
+
+
-
-
- Calibration-related fields
-
-
- | Name |
- Access |
- Prompt |
- Data type |
- Comments |
+
+
+
+ Calibration-related fields
+
+
+
+ | Name |
+ Access |
+ Prompt |
+ Data type |
+ Comments |
-
- | DIR |
- R/W* |
- User Direction |
- RECCHOICE |
- (0:"Pos", 1:"Neg") |
+
+ | DIR |
+ R/W* |
+ User Direction |
+ RECCHOICE |
+ (0:"Pos", 1:"Neg") |
-
- User and dial values are related by the equation
-
- userVAL = DialVAL * DIR + OFFset
- This field is the "DIR" in the above equation. |
+
+ User and dial values are related by the equation
+ userVAL = DialVAL * DIR + OFFset
+ This field is the "DIR" in the above equation. |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
- | OFF |
- R/W |
- User Offset (EGU) |
- DOUBLE |
- User and dial coordinates can differ by a sign (the DIR field) and
-an offset (OFF), according to the following equation:
- userVAL = DialVAL * DIR + OFFset
- This field is "OFFset" in the above equation. It is not normally written
-to directly by the user. |
+
+ | OFF |
+ R/W |
+ User Offset (EGU) |
+ DOUBLE |
+ User and dial coordinates can differ by a sign (the DIR field) and an offset
+ (OFF), according to the following equation:
+ userVAL = DialVAL * DIR + OFFset
+ This field is "OFFset" in the above equation. It is not normally written to
+ directly by the user. |
-
- | FOFF |
- R/W |
- Offset-Freeze Switch |
- RECCHOICE |
- (0:"Variable", 1:"Frozen") |
+
+ | FOFF |
+ R/W |
+ Offset-Freeze Switch |
+ RECCHOICE |
+ (0:"Variable", 1:"Frozen") |
-
- | VOF |
- R/W |
- Variable Offset |
- SHORT |
- Set Offset switch (FOFF) to "Variable". |
+
+ | VOF |
+ R/W |
+ Variable Offset |
+ SHORT |
+ Set Offset switch (FOFF) to "Variable". |
-
- | FOF |
- R/W |
- Freeze Offset |
- SHORT |
- Set Offset switch (FOFF) to "Frozen". |
+
+ | FOF |
+ R/W |
+ Freeze Offset |
+ SHORT |
+ Set Offset switch (FOFF) to "Frozen". |
-
- | The user can cause the difference between user and dial
-coordinates to remain fixed (i.e., the record will not change it, although
-the user may) by setting FOFF to "Frozen." The fields VOF and FOF are intended
-for use in backup/restore operations; any write to them will drive the FOFF
-field to "Variable" (VOF) or "Frozen" (FOF). |
+
+ | The user can cause the difference between user and dial
+ coordinates to remain fixed (i.e., the record will not change it, although the
+ user may) by setting FOFF to "Frozen." The fields VOF and FOF are intended for
+ use in backup/restore operations; any write to them will drive the FOFF field to
+ "Variable" (VOF) or "Frozen" (FOF). |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
- | SET |
- R/W |
- Set/Use Switch |
- RECCHOICE |
- (0:"Use", 1:"Set") |
+
+ | SET |
+ R/W |
+ Set/Use Switch |
+ RECCHOICE |
+ (0:"Use", 1:"Set") |
-
- | SSET |
- R/W |
- Set SET Mode |
- SHORT |
- Set Set/Use switch to "Set". |
+
+ | SSET |
+ R/W |
+ Set SET Mode |
+ SHORT |
+ Set Set/Use switch to "Set". |
-
- | SUSE |
- R/W |
- Set USE Mode |
- SHORT |
- Set Set/Use switch to "Use". |
+
+ | SUSE |
+ R/W |
+ Set USE Mode |
+ SHORT |
+ Set Set/Use switch to "Use". |
-
- | SET is a toggle switch used in calibrating the motor's
-user and dial positions:
- When SET = 0 ("Use"), writes to the user-coordinate drive field (VAL)
-cause the dial-coordinate drive field (DVAL) to change, and the motor to
-move. Writes to the dial-coordinate drive field (DVAL) cause the user-coordinate
- drive field (VAL) to change, and the motor to move.
-
- When SET = 1 ("Set"), writes to the dial-coordinate drive field (DVAL)
-and to the raw drive field (RVAL) cause a new raw motor position to be loaded
-into the hardware without any change to the user-coordinate drive field
-(VAL). Writes to other fields that would normally move the motor, change the
-user-coordinate drive field (VAL), and the offset between user and dial coordinates
-(the OFF field), with corresponding changes in the user-coordinate limit
-fields (HLM and LLM). When the offset is frozen (FOFF=1), writes to any drive
-field affect both user and dial values, and also load the hardware position
-register.
- |
+
+ | SET is a toggle switch used in calibrating the motor's user and
+ dial positions:
+
+ When SET = 0 ("Use"), writes to the user-coordinate drive field (VAL) cause the
+ dial-coordinate drive field (DVAL) to change, and the motor to move. Writes to
+ the dial-coordinate drive field (DVAL) cause the user-coordinate drive field (VAL)
+ to change, and the motor to move.
+
+
+
+ When SET = 1 ("Set"), writes to the dial-coordinate drive field (DVAL) and to
+ the raw drive field (RVAL) cause a new raw motor position to be loaded into the
+ hardware without any change to the user-coordinate drive field (VAL). Writes to
+ other fields that would normally move the motor, change the user-coordinate
+ drive field (VAL), and the offset between user and dial coordinates (the OFF
+ field), with corresponding changes in the user-coordinate limit fields (HLM and
+ LLM). When the offset is frozen (FOFF=1), writes to any drive field affect both
+ user and dial values, and also load the hardware position register.
+
+ |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
-
+
+
-
-
+
+
-
-
- Motor-resolution fields
-
-
- | Name |
- Access |
- Prompt |
- Data type |
- Comments |
+
+
+
+ Motor-resolution fields
+
+
+
+ | Name |
+ Access |
+ Prompt |
+ Data type |
+ Comments |
-
- | MRES |
- R/W* |
- Motor Step Size (EGU) |
- FLOAT |
- May be positive or negative |
+
+ | MRES |
+ R/W* |
+ Motor Step Size (EGU) |
+ FLOAT |
+ May be positive or negative |
-
- | SREV |
- R/W* |
- Steps per Revolution |
- LONG |
- Must be strictly positive |
+
+ | SREV |
+ R/W* |
+ Steps per Revolution |
+ LONG |
+ Must be strictly positive |
-
- | UREV |
- R/W* |
- EGU's per Revolution |
- FLOAT |
- May be positive or negative |
+
+ | UREV |
+ R/W* |
+ EGU's per Revolution |
+ FLOAT |
+ May be positive or negative |
-
- | MRES, and (SREV,UREV) represent two ways of specifying
-the motor resolution--the distance or angle, in engineering units (EGU's),
-associated with a single motor step. The equation relating these quantities
-is "MRES = UREV/SREV". Initially, SREV has the value 200, the number of full
-steps per revolution for most stepper motors, and the record never changes
-this field. Only the user can change it.
- When MRES is changed, the motor record sets UREV = MRES*SREV. When
-UREV or SREV is changed, the motor sets MRES = UREV/SREV. In all cases, the
- effect of a motor resolution change on the reported motor position depends
- in a simple way on the value of the SET field:
- If (SET = 1), new user and dial values (VAL, DVAL) are calculated from the
-existing raw value (RVAL).
- If (SET = 0), a new raw value is calculated from the existing dial value.
-
- The motor doesn't move in either case; neither does the actual motor speed
-(in revolutions per second) change.
-
- If either MRES or UREV is changed, motor speeds that are expressed
-in engineering units per second (i.e., those whose names contain the letter
- 'V': VELO, BVEL, VMAX and VBAS) are automatically adjusted by the motor
-record according to the following equations: VELO = UREV * S; BVEL = UREV
-* SBAK; VMAX = UREV * SMAX; VBAS = UREV * SBAS. Motor speeds that are
-expressed in revolutions per second (S, SBAK, and SBAS) are independent of
-changes to MRES or UREV. In contrast, when SREV is changed, only MRES
-is adjusted by the motor record, thus allowing all other fields to remain
-unaffected.
-
- Currently, changes to motor-resolution fields have no effect on the
-values of limit fields (although they should).
-
- MRES or UREV allow negative values so that the user/dial coordinate
- systems can be configured to the opposite polarity of the motor controller's.
- |
+
+ | MRES, and (SREV,UREV) represent two ways of specifying the motor
+ resolution--the distance or angle, in engineering units (EGU's), associated with
+ a single motor step. The equation relating these quantities is "MRES = UREV/SREV
+ ". Initially, SREV has the value 200, the number of full steps per revolution
+ for most stepper motors, and the record never changes this field. Only the user
+ can change it.
+
+ When MRES is changed, the motor record sets UREV = MRES*SREV. When UREV or SREV
+ is changed, the motor sets MRES = UREV/SREV. In all cases, the effect of a motor
+ resolution change on the reported motor position depends in a simple way on the
+ value of the SET field:
+ If (SET = 1), new user and dial values (VAL, DVAL) are calculated from the
+ existing raw value (RVAL).
+ If (SET = 0), a new raw value is calculated from the existing dial value.
+ The motor doesn't move in either case; neither does the actual motor speed (in
+ revolutions per second) change.
+
+
+
+ If either MRES or UREV is changed, motor speeds that are expressed in
+ engineering units per second (i.e., those whose names contain the letter 'V':
+ VELO, BVEL, VMAX and VBAS) are automatically adjusted by the motor record
+ according to the following equations: VELO = UREV * S; BVEL = UREV * SBAK; VMAX
+ = UREV * SMAX; VBAS = UREV * SBAS. Motor speeds that are expressed in
+ revolutions per second (S, SBAK, and SBAS) are independent of changes to MRES or
+ UREV. In contrast, when SREV is changed, only MRES is adjusted by the
+ motor record, thus allowing all other fields to remain unaffected.
+
+
+
+ Currently, changes to motor-resolution fields have no effect on the values of
+ limit fields (although they should).
+
+
+
+ MRES or UREV allow negative values so that the user/dial coordinate systems can
+ be configured to the opposite polarity of the motor controller's.
+
+ |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
- | ERES |
- R/W* |
- Encoder Step Size (EGU) |
- FLOAT |
- Encoder resolution: the distance or angle, in engineering units, associated
- with a single encoder step. ERES may be positive or negative; it must have
- the same sign as MRES; and it must be nonzero. If the user sets ERES
- to zero, the record will overwrite it with MRES. |
+
+ | ERES |
+ R/W* |
+ Encoder Step Size (EGU) |
+ FLOAT |
+ Encoder resolution: the distance or angle, in engineering units, associated
+ with a single encoder step. ERES may be positive or negative; it must have the
+ same sign as MRES; and it must be nonzero. If the user sets ERES to zero,
+ the record will overwrite it with MRES. |
-
- | RRES |
- R/W |
- Readback Step Size (EGU) |
- FLOAT |
- Readback-device resolution: the distance or angle, in engineering
-units, associated with a unit change of the number retrieved via the readback-
-location input link (RDBL). RRES may be either positive or negative. |
+
+ | RRES |
+ R/W |
+ Readback Step Size (EGU) |
+ FLOAT |
+ Readback-device resolution: the distance or angle, in engineering units,
+ associated with a unit change of the number retrieved via the readback- location
+ input link (RDBL). RRES may be either positive or negative. |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
- | UEIP |
- R/W* |
- Use Encoder If Present |
- RECCHOICE (0:"No", 1:"Yes") |
- Switch: nonzero value tells the record to read the encoder (if the
-hardware indicates an encoder is present) and to ignore the value read back
-from the hardware's step-count register.
- The state of the UEIP, together with the MSTA encoder indicator,
-determine:
-
+ |
+ | UEIP |
+ R/W* |
+ Use Encoder If Present |
+ RECCHOICE (0:"No", 1:"Yes") |
+ Switch: nonzero value tells the record to read the encoder (if the hardware
+ indicates an encoder is present) and to ignore the value read back from the
+ hardware's step-count register.
+
+ The state of the UEIP, together with the MSTA encoder indicator, determine:
+
+
- - if the RRBV is set to either the feedback (REP) or the command (RMP)
-position.
- - whether absolute or relative position commands are used.
-
+ -
+ if the RRBV is set to either the feedback (REP) or the command (RMP) position.
+
+ -
+ whether absolute or relative position commands are used.
+
+
- |
+
-
- | URIP |
- R/W* |
- Use RDBL Link If Present |
- RECCHOICE (0:"No", 1:"Yes") |
- Switch: nonzero value tells the record to get the motor position from
- the readback-location link (RDBL) (if it contains valid EPICS link information,
- and if no error occurs in the attempt to read from the link) and to ignore
- values read back from the hardware's step-count and encoder registers. |
+
+ | URIP |
+ R/W* |
+ Use RDBL Link If Present |
+ RECCHOICE (0:"No", 1:"Yes") |
+ Switch: nonzero value tells the record to get the motor position from the
+ readback-location link (RDBL) (if it contains valid EPICS link information, and
+ if no error occurs in the attempt to read from the link) and to ignore values
+ read back from the hardware's step-count and encoder registers. |
-
- | These switches also direct the record to calculate destinations
- in relative, rather than absolute, terms, since the ratio of encoder and
-readback units to motor steps may not actually be constant. |
+
+ | These switches also direct the record to calculate destinations
+ in relative, rather than absolute, terms, since the ratio of encoder and
+ readback units to motor steps may not actually be constant. |
-
-
+
+
-
-
+
+
-
-
- Motion-related fields
-
-
- | Name |
- Access |
- Prompt |
- Data type |
- Comments |
+
+
+
+ Motion-related fields
+
+
+
+ | Name |
+ Access |
+ Prompt |
+ Data type |
+ Comments |
-
- | VMAX |
- R/W |
- Max Velocity (EGU/s) |
- FLOAT |
- Valid range; 0 <= VMAX. VMAX=0 disables maximum velocity
-range checking. |
+
+ | VMAX |
+ R/W |
+ Max Velocity (EGU/s) |
+ FLOAT |
+ Valid range; 0 <= VMAX. VMAX=0 disables maximum velocity range
+ checking. |
-
- | SMAX |
- R/W |
- Max Velocity (RPS) |
- FLOAT |
- Valid range; 0 <= SMAX |
+
+ | SMAX |
+ R/W |
+ Max Velocity (RPS) |
+ FLOAT |
+ Valid range; 0 <= SMAX |
-
- | VBAS |
- R/W |
- Base Velocity (EGU/s) |
- FLOAT |
- Valid range; 0 <= VBAS |
+
+ | VBAS |
+ R/W |
+ Base Velocity (EGU/s) |
+ FLOAT |
+ Valid range; 0 <= VBAS |
-
- | SBAS |
- R/W |
- Base Speed (RPS) |
- FLOAT |
- Valid range; 0 <= SBAS |
+
+ | SBAS |
+ R/W |
+ Base Speed (RPS) |
+ FLOAT |
+ Valid range; 0 <= SBAS |
-
- | Range checking is done in such a way that any
-minimum (i.e., VBAS/SBAS) or maximum (i.e., VMAX/SMAX) value entered is valid.
- For example, if the minimum is entered and it exceeds the maximum, then
-the maximum is set to the new minimum value. A VMAX value of zero disables
-maximum velocity range checking.
- At boot-up, if one field of a field pair (i.e., VMAX/SMAX, VBAS/SBAS,
- VELO/S, BVEL/SBAK) is zero and the other field is nonzero, the nonzero field
-takes precedence. If both fields of a given field pair are nonzero,
-the RPS member of the field pair (i.e., SMAX, SBAS, S, SBAK) takes precedence.
-
-
- Slew (VELO/S) and backup (BVEL/SBAK) velocity fields are silently
-forced by the motor record to be within the range set by VMAX/SMAX and VBAS/SBAS,
- inclusively.
-
- Those who use both BURT and VMAX (i.e., nonzero VMAX) should insure
- that VMAX and VBAS are placed before VELO and BVEL in their BURT request
-files.
-
- The intent of VBAS/SBAS is to prevent the motor from moving at speeds
- slow enough to excite its resonance, which can cause the motor to miss steps.
-The motor is expected to accelerate from a stand-still to VBAS in one motor
-pulse.
- |
+
+ | Range checking is done in such a way that any minimum
+ (i.e., VBAS/SBAS) or maximum (i.e., VMAX/SMAX) value entered is valid. For
+ example, if the minimum is entered and it exceeds the maximum, then the maximum
+ is set to the new minimum value. A VMAX value of zero disables maximum
+ velocity range checking.
+
+ At boot-up, if one field of a field pair (i.e., VMAX/SMAX, VBAS/SBAS, VELO/S,
+ BVEL/SBAK) is zero and the other field is nonzero, the nonzero field takes
+ precedence. If both fields of a given field pair are nonzero, the RPS
+ member of the field pair (i.e., SMAX, SBAS, S, SBAK) takes precedence.
+
+
+
+ Slew (VELO/S) and backup (BVEL/SBAK) velocity fields are silently forced by the
+ motor record to be within the range set by VMAX/SMAX and VBAS/SBAS, inclusively.
+
+
+
+ Those who use both BURT and VMAX (i.e., nonzero VMAX) should insure that VMAX
+ and VBAS are placed before VELO and BVEL in their BURT request files.
+
+
+
+ The intent of VBAS/SBAS is to prevent the motor from moving at speeds slow
+ enough to excite its resonance, which can cause the motor to miss steps. The
+ motor is expected to accelerate from a stand-still to VBAS in one motor pulse.
+
+ |
-
- | VELO |
- R/W |
- Velocity (EGU/s) |
- FLOAT |
- Valid range; VBAS <= VELO <= VMAX |
+
+ | VELO |
+ R/W |
+ Velocity (EGU/s) |
+ FLOAT |
+ Valid range; VBAS <= VELO <= VMAX |
-
- | S |
- R/W |
- Speed (RPS) |
- FLOAT |
- Valid range; SBAS <= S
- <= SMAX |
+
+ | S |
+ R/W |
+ Speed (RPS) |
+ FLOAT |
+ Valid range; SBAS <= S
+ <= SMAX |
-
- | VELO is the speed, in engineering units per second, at
-which the motor is move after the acceleration phase of a motion is finished.
-S is the same speed expressed in revolutions per second. The record makes
-sure that VELO and S are consistent, using the equation S = VELO/UREV. |
+
+ | VELO is the speed, in engineering units per second, at which the
+ motor is move after the acceleration phase of a motion is finished. S is the
+ same speed expressed in revolutions per second. The record makes sure that VELO
+ and S are consistent, using the equation S = VELO/UREV. |
-
- | ACCL |
- R/W |
- Seconds to Velocity |
- FLOAT |
- The length, in seconds, of the acceleration and deceleration phases
- of a motor motion. |
+
+
+ | HVEL |
+ R/W |
+ Velocity (EGU/s) |
+ FLOAT |
+ Homing velocity; valid range; VBAS <= HVEL <= VMAX |
-
- | The motor record expects the hardware to produce a trapezoidal
- speed profile. That is, the motor speed is expected to increase linearly
-with time from the base speed, VBAS, to the full speed, VELO, in ACCL seconds.
- At the end of a motion, the speed is expected to decrease similarly to VBAS. |
+
+
+ | ACCL |
+ R/W |
+ Seconds to Velocity |
+ FLOAT |
+ The length, in seconds, of the acceleration and deceleration phases of a
+ motor motion. |
-
- | JVEL |
- R/W |
- Jog Velocity (EGU/s) |
- FLOAT |
- Valid range; VBAS <= VELO <= VMAX |
+
+ | The motor record expects the hardware to produce a trapezoidal
+ speed profile. That is, the motor speed is expected to increase linearly with
+ time from the base speed, VBAS, to the full speed, VELO, in ACCL seconds. At the
+ end of a motion, the speed is expected to decrease similarly to VBAS. |
-
- | JAR |
- R/W |
- Jog Acceleraton (EGU/s^2) |
- FLOAT |
- Default value: VELO / ACCL |
+
+ | JVEL |
+ R/W |
+ Jog Velocity (EGU/s) |
+ FLOAT |
+ Valid range; VBAS <= VELO <= VMAX |
-
- | With the OMS and IMS device drivers, jog velocity
- can be changed on-the-fly. The velocity will accelerate to the new
-velocity based on the JAR field. |
+
+ | JAR |
+ R/W |
+ Jog Acceleraton (EGU/s^2) |
+ FLOAT |
+ Default value: VELO / ACCL |
-
- | BDST |
- R/W |
- BL Distance (EGU) |
- FLOAT |
- The signed distance, in dial coordinates, used for backlash takeout. |
+
+ | With the OMS and IMS device drivers, jog velocity can
+ be changed on-the-fly. The velocity will accelerate to the new velocity
+ based on the JAR field. |
-
- | The algorithm used in moves to a (dial-coordinate) position
- called "TARGET" follows:
- 1) If the motor is to move a distance greater than the magnitude
-of BDST, or if the motor is to move in a direction opposite to the sign of
- BDST, then the motor will move first to position (TARGET-BDST), at an acceleration
- specified by ACCL and speed VELO, and then to position TARGET, at an acceleration
- specified by BACC and speed BVEL.
-
- 2) If the motor is to move a distance smaller than the magnitude
-of BDST, and if the motor is to move in the same direction as the sign of
- BDST, then backlash is assumed already to have been taken out, and the motor
-will move to position TARGET at an acceleration specified by BACC and speed
-BVEL.
- |
+
+ | BDST |
+ R/W |
+ BL Distance (EGU) |
+ FLOAT |
+ The signed distance, in dial coordinates, used for backlash takeout. |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+ | The algorithm used in moves to a (dial-coordinate) position
+ called "TARGET" follows:
+
+ 1) If the motor is to move a distance greater than the magnitude of BDST, or if
+ the motor is to move in a direction opposite to the sign of BDST, then the motor
+ will move first to position (TARGET-BDST), at an acceleration specified by ACCL
+ and speed VELO, and then to position TARGET, at an acceleration specified by
+ BACC and speed BVEL.
+
+
+
+ 2) If the motor is to move a distance smaller than the magnitude of BDST, and if
+ the motor is to move in the same direction as the sign of BDST, then backlash is
+ assumed already to have been taken out, and the motor will move to position
+ TARGET at an acceleration specified by BACC and speed BVEL.
+
+ |
-
- | BVEL |
- R/W |
- BL Velocity (EGU/s) |
- FLOAT |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
- | SBAK |
- R/W |
- BL Speed (RPS) |
- FLOAT |
+
+ | BVEL |
+ R/W |
+ BL Velocity (EGU/s) |
+ FLOAT |
-
- | BVEL is the speed, in engineering units per second, at
-which the motor is move after the acceleration phase of a backlash-takeout
-motion is finished. SBAK is the same speed expressed in revolutions per second.
-Neither BVEL nor SBAK may be negative or zero. |
+
+ | SBAK |
+ R/W |
+ BL Speed (RPS) |
+ FLOAT |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+ | BVEL is the speed, in engineering units per second, at which the
+ motor is move after the acceleration phase of a backlash-takeout motion is
+ finished. SBAK is the same speed expressed in revolutions per second. Neither
+ BVEL nor SBAK may be negative or zero. |
-
- | BACC |
- R/W |
- BL Seconds to Veloc. |
- FLOAT |
- The length, in seconds, of the acceleration and deceleration phases
- of a backlash-takeout motion. See discussion of the acceleration field ACCL
-for more specific information. |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+ | BACC |
+ R/W |
+ BL Seconds to Veloc. |
+ FLOAT |
+ The length, in seconds, of the acceleration and deceleration phases of a
+ backlash-takeout motion. See discussion of the acceleration field ACCL for more
+ specific information. |
-
- | FRAC |
- R/W |
- Move Fraction |
- FLOAT |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
- | This field supports closed-loop control of pathological
-devices for which drive values are not expected to compare reproducibly with
-readback values. (Inchworms and other friction-driven devices are good examples:
-the number of steps taken by an inchworm motor is a very poor indicator of
-the distance it has traveled.)
- In a move from position CURRENT to position TARGET, the motor record
- will ask hardware to move a distance FRAC*(TARGET-CURRENT). When that motion
- is complete, the record will request a motion of FRAC*(remaining distance),
- and so on until the target position has been reached.
- |
+
+ | FRAC |
+ R/W |
+ Move Fraction |
+ FLOAT |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+ | This field supports closed-loop control of pathological devices
+ for which drive values are not expected to compare reproducibly with readback
+ values. (Inchworms and other friction-driven devices are good examples: the
+ number of steps taken by an inchworm motor is a very poor indicator of the
+ distance it has traveled.)
+
+ In a move from position CURRENT to position TARGET, the motor record will ask
+ hardware to move a distance FRAC*(TARGET-CURRENT). When that motion is complete,
+ the record will request a motion of FRAC*(remaining distance), and so on until
+ the target position has been reached.
+
+ |
-
- | RDBD |
- R/W |
- Retry Deadband (EGU) |
- FLOAT |
- When the motor has finished a complete motion, possibly including
-backlash takeout, the motor record will compare its current position with
-the desired position. If the magnitude of the difference is greater than
-RDBD, the motor will try again, as if the user had requested a move from
-the now current position to the desired position. Only a limited number of
-retries will be performed (see RTRY). |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
- | RTRY |
- R/W |
- Max retry count |
- SHORT |
- The maximum number of times the motor record will try again to move
- to the desired position. When the retry limit is reached, the motor record
- will declare the motion finished. If the desired position was not reached,
- the field MISS will be set to 1. |
+
+ | RDBD |
+ R/W |
+ Retry Deadband (EGU) |
+ FLOAT |
+ When the motor has finished a complete motion, possibly including backlash
+ takeout, the motor record will compare its current position with the desired
+ position. If the magnitude of the difference is greater than RDBD, the motor
+ will try again, as if the user had requested a move from the now current
+ position to the desired position. Only a limited number of retries will be
+ performed (see RTRY). |
-
-
+
+ | RTRY |
+ R/W |
+ Max retry count |
+ SHORT |
+ The maximum number of times the motor record will try again to move to the
+ desired position. When the retry limit is reached, the motor record will declare
+ the motion finished. If the desired position was not reached, the field MISS
+ will be set to 1. |
+
+
+
-
-
+
+
-
-
- Link-related fields
-
-
- | Name |
- Access |
- Prompt |
- Data type |
- Comments |
+
+
+
+ Link-related fields
+
+
+
+ | Name |
+ Access |
+ Prompt |
+ Data type |
+ Comments |
-
- | OUT |
- R/W |
- Output Specification |
- OUTLINK |
- If Soft Channel device support is specified, this field is an EPICS
- link; each time DVAL is changed, device support puts DVAL to this link.
- Otherwise, this field specifies the hardware to be controlled. |
+
+ | OUT |
+ R/W |
+ Output Specification |
+ OUTLINK |
+ If Soft Channel device support is specified, this field is an EPICS link;
+ each time DVAL is changed, device support puts DVAL to this link.
+ Otherwise, this field specifies the hardware to be controlled. |
-
- | RDBL |
- R |
- Readback Location |
- INLINK |
- This field specifies the field (of this or any other EPICS record)
-from which the motor's current position is to be read when the field URIP
-(Use Readback If Present) has the value "Yes" (1). If this field does not
-contain a valid EPICS link, the URIP may as well have the value "No" (0).
-If Soft Channel device support is specified, this field is monitored for
-value changes by a CA event task. |
+
+ | RDBL |
+ R |
+ Readback Location |
+ INLINK |
+ This field specifies the field (of this or any other EPICS record) from
+ which the motor's current position is to be read when the field URIP (Use
+ Readback If Present) has the value "Yes" (1). If this field does not contain a
+ valid EPICS link, the URIP may as well have the value "No" (0). If Soft
+ Channel device support is specified, this field is monitored for value changes
+ by a CA event task. |
-
- | DOL |
- R |
- Desired Output Loc |
- INLINK |
- If this field contains a valid EPICS link, and the OMSL field has
-the value "closed_loop" (1), then every time the the motor record is processed,
- it will get a value for the VAL field from the link and move to that location,
- ignoring all other drive fields. Closed-loop mode has not been tested extensively. |
+
+ | DOL |
+ R |
+ Desired Output Loc |
+ INLINK |
+ If this field contains a valid EPICS link, and the OMSL field has the value
+ "closed_loop" (1), then every time the the motor record is processed, it will
+ get a value for the VAL field from the link and move to that location, ignoring
+ all other drive fields. Closed-loop mode has not been tested extensively. |
-
- | OMSL |
- R/W |
- Output Mode Select |
- GBLCHOICE |
- (0:"supervisory", 1:"closed_loop")
- If this field has the value "closed_loop" (1), and the field DOL contains
- a valid EPICS link, then every time the the motor record is processed, it
-will get a value for the VAL field from the link and move to that location,
- ignoring all other drive fields. Closed-loop mode has not been tested extensively. |
+
+ | OMSL |
+ R/W |
+ Output Mode Select |
+ GBLCHOICE |
+ (0:"supervisory", 1:"closed_loop")
+ If this field has the value "closed_loop" (1), and the field DOL contains a
+ valid EPICS link, then every time the the motor record is processed, it will get
+ a value for the VAL field from the link and move to that location, ignoring all
+ other drive fields. Closed-loop mode has not been tested extensively. |
-
- | RLNK |
- R |
- Readback OutLink |
- OUTLINK |
- If this field contains a valid EPICS link, then every time the motor
- record is processed, it will put the (engineering-unit) readback value RBV
-to that link. |
+
+ | RLNK |
+ R |
+ Readback OutLink |
+ OUTLINK |
+ If this field contains a valid EPICS link, then every time the motor record
+ is processed, it will put the (engineering-unit) readback value RBV to that link. |
-
- | DINP |
- R/W |
- DMOV Input Link |
- INLINK |
- If Soft Channel device support is specified, the value specified by
- this link is used to set the DONE bit in the MSTA field; which in turn sets
-the DMOV field. |
+
+ | DINP |
+ R/W |
+ DMOV Input Link |
+ INLINK |
+ If Soft Channel device support is specified, the value specified by this
+ link is used to set the DONE bit in the MSTA field; which in turn sets the DMOV
+ field. |
-
- | RINP |
- R/W |
- RMP Input Link |
- INLINK |
- If Soft Channel device support is specified, the value specified by
- this link is used to set the RMP field. |
+
+ | RINP |
+ R/W |
+ RMP Input Link |
+ INLINK |
+ If Soft Channel device support is specified, the value specified by this
+ link is used to set the RMP field. |
-
- | STOO |
- R/W |
- STOP OutLink |
- OUTLINK |
- If Soft Channel device support is specified, a one is written to the
- specified link each time the STOP_AXIS motor command is issued. |
+
+ | STOO |
+ R/W |
+ STOP OutLink |
+ OUTLINK |
+ If Soft Channel device support is specified, a one is written to the
+ specified link each time the STOP_AXIS motor command is issued. |
-
-
- Soft Channel Device Driver
- The Soft Channel database links (i.e., DINP, RINP and STOO) are only processed
- when the Soft Channel device driver is selected. These links are ignored
-when using any other Motor Record device driver.
- The input links (i.e., DINP, RDBL and RINP) are monitored for value changes
-by a CA event task. Users must choose either a dial input link (RDBL)
-or a raw input link (RINP), but not both. At this time, the above links are
- not dynamically retargetable.
- Note that JOG[F/R] does not work with the Soft Channel device driver. |
+
+ Soft Channel Device Driver The Soft Channel
+ database links (i.e., DINP, RINP and STOO) are only processed when the Soft
+ Channel device driver is selected. These links are ignored when using any
+ other Motor Record device driver.
+ The input links (i.e., DINP, RDBL and RINP) are monitored for value changes by a
+ CA event task. Users must choose either a dial input link (RDBL) or a raw
+ input link (RINP), but not both. At this time, the above links are not
+ dynamically retargetable.
+ Note that JOG[F/R] does not work with the Soft Channel device driver. |
-
-
+
+
-
-
+
+
-
-
- Limit-related fields
-
-
- | Name |
- Access |
- Prompt |
- Data type |
- Comments |
+
+
+
+ Limit-related fields
+
+
+
+ | Name |
+ Access |
+ Prompt |
+ Data type |
+ Comments |
-
- | HLM |
- R/W* |
- User High Limit |
- FLOAT |
- The maximum allowed value of the VAL field. If HLM changes so that
-VAL is no longer less than HLM, then the record will set the field LVIO to
-1. If the DIR field has the value "Pos", then HLM will always be consistent
-with DHLM, otherwise HLM will always be consistent with DLLM. |
+
+ | HLM |
+ R/W* |
+ User High Limit |
+ FLOAT |
+ The maximum allowed value of the VAL field. If HLM changes so that VAL is no
+ longer less than HLM, then the record will set the field LVIO to 1. If the DIR
+ field has the value "Pos", then HLM will always be consistent with DHLM,
+ otherwise HLM will always be consistent with DLLM. |
-
- | LLM |
- R/W* |
- User Low Limit |
- FLOAT |
- The minimum allowed value of the VAL field. If LLM changes so that
-VAL is no longer greater than LLM, then the record will set the field LVIO
-to 1. If the DIR field has the value "Pos", then LLM will always be consistent
- with DLLM, otherwise LLM will always be consistent with DHLM. |
+
+ | LLM |
+ R/W* |
+ User Low Limit |
+ FLOAT |
+ The minimum allowed value of the VAL field. If LLM changes so that VAL is no
+ longer greater than LLM, then the record will set the field LVIO to 1. If the
+ DIR field has the value "Pos", then LLM will always be consistent with DLLM,
+ otherwise LLM will always be consistent with DHLM. |
-
- | DHLM |
- R/W* |
- Dial High Limit |
- FLOAT |
- The maximum allowed value of the DVAL field. If DHLM changes so that
- DVAL is no longer less than DHLM, then the record will set the field LVIO
- to 1.. If the DIR field has the value "Pos", then DHLM will always be consistent
- with HLM, otherwise DHLM will always be consistent with LLM. |
+
+ | DHLM |
+ R/W* |
+ Dial High Limit |
+ FLOAT |
+ The maximum allowed value of the DVAL field. If DHLM changes so that DVAL is
+ no longer less than DHLM, then the record will set the field LVIO to 1.. If the
+ DIR field has the value "Pos", then DHLM will always be consistent with HLM,
+ otherwise DHLM will always be consistent with LLM. |
-
- | DLLM |
- R/W* |
- Dial Low Limit |
- FLOAT |
- The minimum allowed value of the DVAL field. If DLLM changes so that
- DVAL is no longer greater than DLLM, then the record will set the field
-LVIO to 1. If the DIR field has the value "Pos", then DLLM will always be
-consistent with LLM, otherwise DLLM will always be consistent with HLM. |
+
+ | DLLM |
+ R/W* |
+ Dial Low Limit |
+ FLOAT |
+ The minimum allowed value of the DVAL field. If DLLM changes so that DVAL is
+ no longer greater than DLLM, then the record will set the field LVIO to 1. If
+ the DIR field has the value "Pos", then DLLM will always be consistent with LLM,
+ otherwise DLLM will always be consistent with HLM. |
-
- | LVIO |
- R |
- Limit violation |
- SHORT |
- A value of 1 indicates that the dial-value drive field, DVAL, or the
- dial-value readback field, DRBV, is outside of the limits (DHLM, DLLM),
-and this prevents the motor from moving. If the backlash distance, BDST,
-is non-zero, it further restricts the allowable range of DVAL. When a JOG
-button is hit, LVIO goes to 1 and stops the motor if/when DVAL gets to within
-one second's travel time of either limit. |
+
+ | LVIO |
+ R |
+ Limit violation |
+ SHORT |
+ A value of 1 indicates that the dial-value drive field, DVAL, or the dial-value
+ readback field, DRBV, is outside of the limits (DHLM, DLLM), and this prevents
+ the motor from moving. If the backlash distance, BDST, is non-zero, it further
+ restricts the allowable range of DVAL. When a JOG button is hit, LVIO goes to 1
+ and stops the motor if/when DVAL gets to within one second's travel time of
+ either limit. |
-
- | PERL |
- R/W |
- Periodic Limits |
- RECCHOICE |
- (0:"No", 1:"Yes")
- Not implemented. Originally intended to support periodic "limits" on the
-VAL field (such as those associated with a rotation stage--e.g., [0...360]
- or [-180...180]) independently of the actual soft limits HLM and LLM. |
+
+ | PERL |
+ R/W |
+ Periodic Limits |
+ RECCHOICE |
+ (0:"No", 1:"Yes")
+ Not implemented. Originally intended to support periodic "limits" on the VAL
+ field (such as those associated with a rotation stage--e.g., [0...360] or [-180...180])
+ independently of the actual soft limits HLM and LLM. |
-
- | HOPR |
- R/W |
- High Operating Range |
- FLOAT |
- Not used. See HLM and DHLM. |
+
+ | HOPR |
+ R/W |
+ High Operating Range |
+ FLOAT |
+ Not used. See HLM and DHLM. |
-
- | LOPR |
- R/W |
- Low Operating Range |
- FLOAT |
- Not used. See LLM and DLLM. |
+
+ | LOPR |
+ R/W |
+ Low Operating Range |
+ FLOAT |
+ Not used. See LLM and DLLM. |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
- | HLS |
- R |
- At High Limit Switch |
- SHORT |
+
+ | HLS |
+ R |
+ At High Limit Switch |
+ SHORT |
-
- | RHLS |
- R |
- Raw High Limit Switch |
- SHORT |
+
+ | RHLS |
+ R |
+ Raw High Limit Switch |
+ SHORT |
-
- | If either of these fields is nonzero, then the motor is
-at the positive-limit switch, where the positive sense is that of the user-coordinate
- system for HLS, and that of the raw (step-number) coordinate system for
-RHLS. |
+
+ | If either of these fields is nonzero, then the motor is at the
+ positive-limit switch, where the positive sense is that of the user-coordinate
+ system for HLS, and that of the raw (step-number) coordinate system for RHLS. |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
- | LLS |
- R |
- At Low Limit Switch |
- SHORT |
+
+ | LLS |
+ R |
+ At Low Limit Switch |
+ SHORT |
-
- | RLLS |
- R |
- Raw Low Limit Switch |
- SHORT |
+
+ | RLLS |
+ R |
+ Raw Low Limit Switch |
+ SHORT |
-
- | If either of these fields is nonzero, then the motor is
-at the negative-limit switch, where the positive sense is that of the user-coordinate
- system for LLS, and that of the raw (step-number) coordinate system for
-RLLS. |
+
+ | If either of these fields is nonzero, then the motor is at the
+ negative-limit switch, where the positive sense is that of the user-coordinate
+ system for LLS, and that of the raw (step-number) coordinate system for RLLS. |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
-
+
+
-
-
+
+
-
-
- Command-button fields
-
-
- | Name |
- Access |
- Prompt |
- Data type |
- Comments |
+
+
+
+ Command-button fields
+
+
+
+ | Name |
+ Access |
+ Prompt |
+ Data type |
+ Comments |
-
- | SPMG |
- R/W* |
- Stop/Pause/Move/Go |
- RECCHOICE |
- (0:"Stop", 1:"Pause", 2:"Move", 3:"Go") |
+
+ | SPMG |
+ R/W* |
+ Stop/Pause/Move/Go |
+ RECCHOICE |
+ (0:"Stop", 1:"Pause", 2:"Move", 3:"Go") |
-
- | This field is intended primarily for interactive use, and
- normally has the value "Go."
- If the user sets this field to "Stop," the motor will decelerate
-to a stop, the VAL field will be set equal to the RBV field, and the DVAL
- field will be set equal to the DRBV field. (These actions ensure that the
- motor will not start moving again until a drive field is changed.) In any
- case, the motor will not move while SPMG has the value "Stop" or "Pause."
-
-
- If "SPMG" has the value "Move," the motor record will reset SPMG
-to "Pause" when a motion completes. This behavior supports users who want
- a motor to sit still until they say "Move", no matter what changes occur
-in the drive fields.
- |
+
+ | This field is intended primarily for interactive use, and
+ normally has the value "Go."
+
+ If the user sets this field to "Stop," the motor will decelerate to a stop, the
+ VAL field will be set equal to the RBV field, and the DVAL field will be set
+ equal to the DRBV field. (These actions ensure that the motor will not start
+ moving again until a drive field is changed.) In any case, the motor will not
+ move while SPMG has the value "Stop" or "Pause."
+
+
+
+ If "SPMG" has the value "Move," the motor record will reset SPMG to "Pause" when
+ a motion completes. This behavior supports users who want a motor to sit still
+ until they say "Move", no matter what changes occur in the drive fields.
+
+ |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
- | STOP |
- R/W* |
- Stop |
- SHORT |
+
+ | STOP |
+ R/W* |
+ Stop |
+ SHORT |
-
- | When this field is set to 1, the record will immediately
- reset it to 0, and the motor will decelerate to a stop. When the motor has
-stopped, VAL will be set equal to RBV, and DVAL will be set equal to DRBV.
-(This ensures that the motor will not start moving the next time the record
-is processed, unless a drive field is explicitly changed. If you want the
-motor to pause, use the SPMG field.) |
+
+ | When this field is set to 1, the record will immediately reset
+ it to 0, and the motor will decelerate to a stop. When the motor has stopped,
+ VAL will be set equal to RBV, and DVAL will be set equal to DRBV. (This ensures
+ that the motor will not start moving the next time the record is processed,
+ unless a drive field is explicitly changed. If you want the motor to pause, use
+ the SPMG field.) |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
- | HOMF |
- R/W* |
- Home Forward |
- SHORT |
+
+ | HOMF |
+ R/W* |
+ Home Forward |
+ SHORT |
-
- | HOMR |
- R/W* |
- Home Reverse |
- SHORT |
+
+ | HOMR |
+ R/W* |
+ Home Reverse |
+ SHORT |
-
- | When one of these fields is set to 1, the motor will decelerate
- to a stop if already moving, move in the indicated direction (in dial
- coordinates) at the acceleration specified by ACCL and a speed of 1000
-motor pulses per second, until the hardware detects the "home" switch has
-become active. Then the hardware will do something hardware dependent in
-response to its "home" command, if any. (The OMS hardware causes the motor
-to decelerate to a stop.) When the motor stops, the VAL field will be set
-equal to the RBV field, and the DVAL field will be set equal to the DRBV
-field. These fields can be set to 1, but setting either field to 0
-results in an error. The record sets HOM[F/R] to zero when the homing
-procedure is either completed or aborted. |
+
+ | When one of these fields is set to 1, the motor will decelerate
+ to a stop if already moving, move in the indicated direction (in dial
+ coordinates) at the acceleration specified by ACCL and a speed spedified by HVEL,
+ until the hardware detects the "home" switch has become active. Then the
+ hardware will do something hardware dependent in response to its "home" command,
+ if any. (The OMS hardware causes the motor to decelerate to a stop.) When the
+ motor stops, the VAL field will be set equal to the RBV field, and the DVAL
+ field will be set equal to the DRBV field. These fields can be set to 1,
+ but setting either field to 0 results in an error. The record sets HOM[F/R]
+ to zero when the homing procedure is either completed or aborted. |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
- | JOGF |
- R/W* |
- Jog motor Forward |
- SHORT |
+
+ | JOGF |
+ R/W* |
+ Jog motor Forward |
+ SHORT |
-
- | JOGR |
- R/W* |
- Jog motor Reverse |
- SHORT |
+
+ | JOGR |
+ R/W* |
+ Jog motor Reverse |
+ SHORT |
-
- | When one of these fields is set to 1, the motor will decelerate
- to a stop if already moving, and move in the indicated direction (in user
- coordinates) at an acceleration specified by ACCL and speed VELO, until
-the field goes to 0. Then the motor will set VAL to RBV and DVAL to DRBV,
-decelerate to a stop, and execute a (backlash-corrected, if BDST is nonzero)
-move to the position at which the field went to 0.
- These fields are dangerous when used over channel access, because
-the motor does not stop moving until a second message is received. If a very
- busy network should cause that second message to be lost, the motor will
-travel to its limit switch or hard stop.
- |
+
+ | When one of these fields is set to 1, the motor will decelerate
+ to a stop if already moving, and move in the indicated direction (in user
+ coordinates) at an acceleration specified by ACCL and speed VELO, until the
+ field goes to 0. Then the motor will set VAL to RBV and DVAL to DRBV, decelerate
+ to a stop, and execute a (backlash-corrected, if BDST is nonzero) move to the
+ position at which the field went to 0.
+
+ These fields are dangerous when used over channel access, because the motor does
+ not stop moving until a second message is received. If a very busy network
+ should cause that second message to be lost, the motor will travel to its limit
+ switch or hard stop.
+
+ |
-
-
- |
-
- |
-
- |
-
- |
-
- |
+
+
+ |
+
+ |
+
+ |
+
+ |
+
+ |
-
- | TWF |
- R/W* |
- Tweak motor Forward |
- SHORT |
+
+ | TWF |
+ R/W* |
+ Tweak motor Forward |
+ SHORT |
-
- | TWR |
- R/W* |
- Tweak motor Reverse |
- SHORT |
+
+ | TWR |
+ R/W* |
+ Tweak motor Reverse |
+ SHORT |
-
- | When one of these fields is set to 1, the record will immediately
- reset it to 0, and the motor will move (with backlash takeout if BDST is
-nonzero) by a distance TWV (in user coordinates) at the acceleration specified
-by ACCL and at speed VELO. |
+
+ | When one of these fields is set to 1, the record will
+ immediately reset it to 0, and the motor will move (with backlash takeout if
+ BDST is nonzero) by a distance TWV (in user coordinates) at the acceleration
+ specified by ACCL and at speed VELO. |
-
- | TWV |
- R/W* |
- Tweak Step Size (EGU) |
- FLOAT |
- This field contains the distance the motor is to move in response
-to the TWF and TWR buttons. |
+
+ | TWV |
+ R/W* |
+ Tweak Step Size (EGU) |
+ FLOAT |
+ This field contains the distance the motor is to move in response to the
+ TWF and TWR buttons. |
-
-
+
+
-
-
+
+
-
-
- Drive fields
-
-
- | Name |
- Access |
- Prompt |
- Data type |
- Comments |
+
+
+
+ Drive fields
+
+
+
+ | Name |
+ Access |
+ Prompt |
+ Data type |
+ Comments |
-
- | VAL |
- R/W* |
- User Desired Value |
- DOUBLE |
- This is the desired position in user coordinates. When this field
-is written to, DVAL and RVAL will be changed correspondingly, and the motor
-will move (with backlash takeout if BDST is nonzero) to the newly written
-position. |
+
+ | VAL |
+ R/W* |
+ User Desired Value |
+ DOUBLE |
+ This is the desired position in user coordinates. When this field is written
+ to, DVAL and RVAL will be changed correspondingly, and the motor will move (with
+ backlash takeout if BDST is nonzero) to the newly written position. |
-
- | DVAL |
- R/W* |
- Dial Desired Value |
- DOUBLE |
- This is the desired position in dial coordinates. When this field
-is written to, VAL and RVAL will be changed correspondingly, and the motor
-will move (with backlash takeout if BDST is nonzero) to the newly written
-position. |
+
+ | DVAL |
+ R/W* |
+ Dial Desired Value |
+ DOUBLE |
+ This is the desired position in dial coordinates. When this field is written
+ to, VAL and RVAL will be changed correspondingly, and the motor will move (with
+ backlash takeout if BDST is nonzero) to the newly written position. |
-
- | RVAL |
- R/W* |
- Raw Desired Value |
- DOUBLE |
- This is the desired position in raw coordinates. When this field is
- written to, VAL and DVAL will be changed correspondingly, and the motor
-will move (with backlash takeout if BDST is nonzero) to the newly written
-position. |
+
+ | RVAL |
+ R/W* |
+ Raw Desired Value |
+ DOUBLE |
+ This is the desired position in raw coordinates. When this field is written
+ to, VAL and DVAL will be changed correspondingly, and the motor will move (with
+ backlash takeout if BDST is nonzero) to the newly written position. |
-
- | RLV |
- R/W* |
- Relative Value |
- DOUBLE |
- When this field is changed, its value will be added to VAL, the field
- itself will immediately be reset to 0, and the motor record will behave
-as though the VAL field had been changed directly. |
+
+ | RLV |
+ R/W* |
+ Relative Value |
+ DOUBLE |
+ When this field is changed, its value will be added to VAL, the field itself
+ will immediately be reset to 0, and the motor record will behave as though the
+ VAL field had been changed directly. |
-
-
+
+
-
-
+
+
-
-
- Status/readback fields
-
-
- | Name |
- Access |
- Prompt |
- Data type |
- Comments |
-
-
- | RBV |
- R |
- User Readback Value |
- DOUBLE |
- The current motor position, in user coordinates, from the motor hardware
- (default), or from the encoder supported by the motor-controller hardware
- (if UEIP is nonzero), or from the readback link RDBL (if URIP is nonzero). |
-
-
- | DRBV |
- R |
- Dial Readback Value |
- DOUBLE |
- The current motor position, in dial coordinates, from the motor hardware
- (default), or from the encoder supported by the motor-controller hardware
- (if UEIP is nonzero), or from the readback link RDBL (if URIP is nonzero). |
-
-
- | DMOV |
- R |
- Done moving to value |
- SHORT |
-
-
- | This field is set to 0 when the motor record begins a motion,
- and remains 0 through any retries and backlash corrections that may be required
-until the motor record has completely finished that motion, whereupon the
-field is set to 1. DMOV is guaranteed to execute and post a 1/0/1 pulse when
-the motor is commanded to move--even if no motion actually occurs because
-the motor was commanded to move to its current position. |
-
-
- | MOVN |
- R |
- Motor is moving |
- SHORT |
- This field is set to 1 while the record believes that the motor actually
- is moving. This field is not the inverse of DMOV, since it may go to zero
- during a complex motion, if that motion includes a momentary stop. |
-
-
- | DLY |
- R/W |
- Readback settle time (s) |
- FLOAT |
- Delay (in seconds) the time between motor controller done and motor
- record done (i.e., DMOV). |
-
-
- | DIFF |
- R |
- Difference dval-drbv |
- DOUBLE |
- DIFF is the difference, in engineering units, between
-the desired motor position, and the readback device's report of the current
-position. RDIF is the same difference in "raw" units (normally, steps). |
-
-
- | RDIF |
- R |
- Difference rval-rrbv |
- LONG |
-
-
- | RRBV |
- R |
- Raw Readback Value |
- DOUBLE |
- The current position of the motor, encoder, or readback link, as received
- from whatever source has been selected to provide position information.
-The units associated with this field depend on the source. |
-
-
- | RMP |
- R |
- Raw Motor Position |
- DOUBLE |
- The contents of the hardware's step-count register. This field contains
- the same information as the dial value, but in steps, rather than in engineering
- units. |
-
-
- | REP |
- R |
- Raw Encoder Position |
- DOUBLE |
- The contents of the hardware's encoder-count register. Ideally, this
- field contains the same information as the dial value, but in encoder counts,
- rather than in engineering units. |
-
-
- | MSTA |
- R |
- Motor Status |
- ULONG |
- The motor status as received from the hardware. The MSTA bits
- are defined as follows:
-
-
- - DIRECTION: (0:Negative, 1:Positive)
- - DONE: motion is complete.
- - PLUS_LS: plus limit switch has been hit.
- - HOMELS: state of the home limit switch.
- - Unused
- - POSITION: closed-loop position control is enabled.
- - Unused
- - HOME: if at home position.
- - PRESENT: encoder is present.
- - PROBLEM: driver stopped polling.
- - MOVING: non-zero velocity present.
- - GAIN_SUPPORT: motor supports closed-loop position control.
- - COMM_ERR: Controller communication error.
- - MINUS_LS: minus limit switch has been hit.
-
-
-
-
- |
-
-
- | TDIR |
- R |
- Direction of Travel |
- SHORT |
- The direction in which the motor is currently traveling (or was most
- recently traveling), as received from the hardware. If 0, the raw readback
- value should be decreasing. |
-
-
- | ATHM |
- R |
- At HOME |
- SHORT |
- The state of the hardware's "home" switch. If 1, the motor has hit
-the switch. |
-
-
- | RCNT |
- R |
- Retry count |
- SHORT |
- The number of times the motor record has detected failure of the motor
- to land within the retry-deadband distance of the desired position. |
-
-
- | MISS |
- R |
- Ran out of retries |
- SHORT |
- If 1, the motor has failed to land on the desired position more than
- the allowed number of times. This field will be reset the next time the
-motor succeeds in reaching the desired position. |
-
-
- | RVEL |
- R |
- Raw Velocity |
- LONG |
- Speed in steps per second that the motor actually is moving. |
-
-
-
-
-
-
-
-
-
-
- Servo fields
-
-
-
-
-
- | PID related record fields accept only normalized
- values (i.e., 0.0 <= value <= 1.0). Before sending them to the
-motor controller, device support scales the record fields to valid motor controller
-parameters,. Let the motor controller PID parameters be represented
-by CKP, CKI and CKD; then the PID coefficients are converted from motor record
-fields to controller parameters as follows:
- For the MM4000; CKP = PCOF, CKI = ICOF and CKD = DCOF.
- For all OMS controllers; CKP = 1999.9 * PCOF, CKI = 1999.9 * ICOF,
-CKD = 1999.9 * DCOF.
-
- Note the following:
-
-
- - When commanded to move the OMS control law is a PD loop, when it is
-holding a position it is a PID loop.
- - The Proportional Gain cannot be turned off (i.e., set to zero) in
-an OMS controller. The minimum value is PCOF = 0.00005 (CKP = 0.1).
- If the user sets PCOF < 0.00005 for an OMS controller, device support
-silently resets it to it's minimum value of 0.00005.
-
-
- |
-
-
- |
- Name
- |
-
- Access
- |
-
- Prompt
- |
-
- Data type
- |
-
- Comments
- |
-
-
- | CNEN |
- R/W |
- Enable control |
- RECCHOICE |
- (0:"Disable", 1:"Enable") Enable/Disable closed-loop position
- control. This field is active only if the GAIN_SUPPORT bit in the
-MSTA is true. This field is set by both the user and device support.
- CNEN is set to Disable by device support when it detects a motion
-controller error; e.g. maximum following error exceeded. |
-
-
- | PCOF |
- R/W |
- Proportional Gain |
- FLOAT |
- Valid range; 0.0 <= PCOF <= 1.0 |
-
-
- | ICOF |
- R/W |
- Integral Gain |
- FLOAT |
- Valid range; 0.0 <= ICOF <= 1.0 |
-
-
- | DCOF |
- R/W |
- Derivative Gain |
- FLOAT |
- Valid range; 0.0 <= DCOF <= 1.0 |
-
-
-
-
-
-
-
-
-
-
-
-
- Alarm fields
-
-
-
- | Name |
- Access |
- Prompt |
- Data type |
- Comments |
-
-
- | HIHI |
- R/W* |
- Hihi Alarm Limit |
- FLOAT |
-
-
- | LOLO |
- R/W* |
- Lolo Alarm Limit |
- FLOAT |
-
-
- | HIGH |
- R/W* |
- High Alarm Limit |
- FLOAT |
-
-
- | LOW |
- R/W* |
- Low Alarm Limit |
- FLOAT |
-
-
- | HHSV |
- R/W* |
- Hihi Severity |
- GBLCHOICE |
- Not used. |
-
-
- | LLSV |
- R/W* |
- Lolo Severity |
- GBLCHOICE |
- Not used. |
-
-
- | HSV |
- R/W* |
- High Severity |
- GBLCHOICE |
- Not used. |
-
-
- | LSV |
- R/W* |
- Low Severity |
- GBLCHOICE |
- Not used. |
-
-
- | HLSV |
- R/W* |
- HW Limit Switch Violation Severity |
- GBLCHOICE |
-
-
-
-
-
-
-
-
-
- Miscellaneous fields
-
-
- | Name |
- Access |
- Prompt |
- Data type |
- Comments |
-
-
- | PREC |
- R/W |
- Display Precision |
- SHORT |
- The number of digits to the right of the decimal that are to be displayed
- by MEDM and other channel-access clients. |
-
-
- | EGU |
- R/W |
- Engineering Units |
- STRING |
- String sent to channel-access clients who ask for engineering units. |
-
-
- | VERS |
- R |
- Code Version |
- FLOAT |
- Version number of the recMotor.c code. |
-
-
- | CARD |
- R |
- Card Number |
- SHORT |
- For VME based devices (i.e., OMS VME8/44, OMS VME58 and V544) this
-is the VME card number, derived from the output link. Cards are numbered
-from zero according to their VME addresses. Oregon Micro Systems series
-VME8 and VME44 cards occur in the same series, since they are handled by the
-same driver. Oregon Micro Systems VME58 cards are numbered separately,
-as are Highland Technology V540 cards. This field is set to -1 for non-VME
-based device/drivers. |
-
-
-
- Command Primitives
- The following three fields comprise the Command Primitives feature.
- The command primitive record fields are available to the user to send ASCII
- command primitives to the motor control board at fixed, predefined, times.
- Each of the fields is defined as a character string. Consult the motor
-controller manual for command protocols. No error checking is done by
-the motor record or the device driver to insure that the command strings are
-valid. Each field is terminated by the device driver according
-to the command protocol. Command primitives that result in a response
-from the motion control board are valid, but the response is not processed.
-This feature is currently only available with OMS VME8/44/58 or Newport MM4000
-device support.
- Device Directives
-
-
- - Valid only in the INIT field.
- - Must be identified by the following;
-
- - First character of INIT string must be a '@'.
- - One or more characters followed by a terminating '@'; i.e., device
-directives must have nonzero length.
- - A valid device directive; currently, only "DPM_ON".
-
- - INIT strings are stripped of valid device directives (including @'s)
-and tested for nonzero length before being sent to the controller. For
-example, given the INIT string, "@DPM_ON@HE", the device directive @DPM_ON@
- is stripped out before HE is sent to the controller.
-
-
- Driver Power Monitoring
-
- - This feature is only available with the OMS VME58 device support.
- - The 8 User I/O signals are assigned to the 8 possible VME58 axes
-as follows:
-
-
- User I/O #0 <> X axis
-
- " "
-1 <> Y "
- ........................................
-
- " "
-7 <> S "
-
- - Drive-power monitoring defaults to disabled at boot-up. Request
-enabling drive-power monitoring by entering the device directive "@DPM_ON@"
-command into the motor record initialization field (i.e., INIT). The
-INIT field is processed at record initialization (i.e., bootup), hence if
-there are no errors, drive-power monitoring will be enabled after the next
-bootup.
- - Whenever a request is made to enable drive-power status monitoring,
-an error check is made (using the VME58 "RB" command) to verify that the User
-I/O has been configured as an input. The following message will appear
-in the error log if a configuration error is detected; "Invalid VME58 configuration;
-RB = 0x####", where "####" is the VME58's response to the RB command.
- - When drive-power status monitoring is enabled and a power failure
-is detected, the device driver will respond by activating the the RA_OVERTRAVEL
-bit in the MSTA. This results in either HLS or LLS being activated depending
-on the DIR field. In addition, the following message will appear in the error
-log; "Drive power failure at VME58 card#?? motor#??".
-
-
- |
-
-
- | INIT |
- R/W |
- Startup commands |
- STRING |
- Sent at record initialization. |
-
-
- | PREM |
- R/W |
- Pre-move commands |
- STRING |
- Sent before every command string that causes motion. |
-
-
- | POST |
- R/W |
- Post-move commands |
- STRING |
- Sent after a complete motion is finished or when an overtravel limit
- switch is detected. |
-
-
-
-
-
-
-
-
-
- Private fields
-
-
- | Name |
- Access |
- Prompt |
- Data type |
- Comments |
-
-
- | CBAK |
- None |
- Callback structure |
- NOACCESS |
-
- |
-
-
- | LVAL |
- R |
- Last User Des Val |
- DOUBLE |
-
-
- | LDVL |
- R |
- Last Dial Des Val |
- DOUBLE |
-
-
- | LRVL |
- R |
- Last Raw Des Val |
- DOUBLE |
-
-
- | LRLV |
- R |
- Last Rel Value |
- DOUBLE |
-
-
- CDIR
- |
- R |
- Command direction
- |
- SHORT
- |
-
-
- | PP |
- R |
- Post process command |
- SHORT |
-
-
- | MIP |
- R |
- Motion In Progress |
- SHORT |
-
-
- | MMAP |
- R |
- Monitor Mask |
- ULONG |
-
-
- | NMAP |
- R |
- Monitor Mask |
- ULONG |
-
-
- | LSPG |
- R |
- Last SPMG |
- RECCHOICE |
- (see SPMG) |
-
-
-
-
-
-
-
-
-
- Files, device support
- The following table briefly describes all of the files required to implement
- and use the motor record. The reader is assumed to be familiar with the
-
- EPICS Application Source/Release Control document
- which describes how to build an EPICS application tree into which these
-files are to be placed, and how to run "makesdr" and "gnumake" to build the
-record support. These files can all be obtained from the
- EPICS Software Distribution
- (in the
- custom-software section
- ).
-
+
+
+
+ Status/readback fields
+
-
- SOURCE CODE
- files to be placed in <top>/<app>App/src/ |
+
+ | Name |
+ Access |
+ Prompt |
+ Data type |
+ Comments |
-
- | motorRecord.dbd |
- Database Definition file for motor record. |
+
+ | RBV |
+ R |
+ User Readback Value |
+ DOUBLE |
+ The current motor position, in user coordinates, from the motor hardware (default),
+ or from the encoder supported by the motor-controller hardware (if UEIP is
+ nonzero), or from the readback link RDBL (if URIP is nonzero). |
-
- | motorRecord.c |
- Record support for the motor record |
+
+ | DRBV |
+ R |
+ Dial Readback Value |
+ DOUBLE |
+ The current motor position, in dial coordinates, from the motor hardware (default),
+ or from the encoder supported by the motor-controller hardware (if UEIP is
+ nonzero), or from the readback link RDBL (if URIP is nonzero). |
-
- | motor.h |
- Header included by all .c files |
+
+ | DMOV |
+ R |
+ Done moving to value |
+ SHORT |
-
-
- |
-
- |
+
+ | This field is set to 0 when the motor record begins a motion,
+ and remains 0 through any retries and backlash corrections that may be required
+ until the motor record has completely finished that motion, whereupon the field
+ is set to 1. DMOV is guaranteed to execute and post a 1/0/1 pulse when the motor
+ is commanded to move--even if no motion actually occurs because the motor was
+ commanded to move to its current position. |
-
- | motordevCom.c |
- Device support common to all motor Record device drivers. |
+
+ | MOVN |
+ R |
+ Motor is moving |
+ SHORT |
+ This field is set to 1 while the record believes that the motor actually is
+ moving. This field is not the inverse of DMOV, since it may go to zero during a
+ complex motion, if that motion includes a momentary stop. |
-
- | motordevCom.h |
- Device support header file. |
+
+ | DLY |
+ R/W |
+ Readback settle time (s) |
+ FLOAT |
+ Delay (in seconds) the time between motor controller done and motor record
+ done (i.e., DMOV). |
-
- | motordrvCom.c |
- Driver support common to all motor Record device drivers. |
+
+ | DIFF |
+ R |
+ Difference dval-drbv |
+ DOUBLE |
+ DIFF is the difference, in engineering units, between the
+ desired motor position, and the readback device's report of the current position.
+ RDIF is the same difference in "raw" units (normally, steps). |
-
- | motordrvCom.h |
- Driver support header file. |
+
+ | RDIF |
+ R |
+ Difference rval-rrbv |
+ LONG |
-
- | motordrvComCode.h |
- Local variables common to all motor Record drivers. |
+
+ | RRBV |
+ R |
+ Raw Readback Value |
+ DOUBLE |
+ The current position of the motor, encoder, or readback link, as received
+ from whatever source has been selected to provide position information. The
+ units associated with this field depend on the source. |
-
-
- |
- NOTE: All of the above files are required for any and all motor Record
- device drivers. |
+
+ | RMP |
+ R |
+ Raw Motor Position |
+ DOUBLE |
+ The contents of the hardware's step-count register. This field contains the
+ same information as the dial value, but in steps, rather than in engineering
+ units. |
-
-
- |
-
- |
+
+ | REP |
+ R |
+ Raw Encoder Position |
+ DOUBLE |
+ The contents of the hardware's encoder-count register. Ideally, this field
+ contains the same information as the dial value, but in encoder counts, rather
+ than in engineering units. |
-
- | devOmsCom.c |
- Device support common to all Oregon Micro Systems device drivers. |
+
+ | MSTA |
+ R |
+ Motor Status |
+ ULONG |
+ The motor status as received from the hardware. The MSTA bits are
+ defined as follows:
+
+
+ -
+ DIRECTION: (0:Negative, 1:Positive)
+
+ -
+ DONE: motion is complete.
+
+ -
+ PLUS_LS: plus limit switch has been hit.
+
+ -
+ HOMELS: state of the home limit switch.
+
+ -
+ Unused
+
+ -
+ POSITION: closed-loop position control is enabled.
+
+ -
+ Unused
+
+ -
+ HOME: if at home position.
+
+ -
+ PRESENT: encoder is present.
+
+ -
+ PROBLEM: driver stopped polling.
+
+ -
+ MOVING: non-zero velocity present.
+
+ -
+ GAIN_SUPPORT: motor supports closed-loop position control.
+
+ -
+ COMM_ERR: Controller communication error.
+
+ -
+ MINUS_LS: minus limit switch has been hit.
+
+
+
+
+ |
-
- | devOmsCom.h |
- Device support header file common to all Oregon Micro Systems device
- drivers. |
+
+ | TDIR |
+ R |
+ Direction of Travel |
+ SHORT |
+ The direction in which the motor is currently traveling (or was most
+ recently traveling), as received from the hardware. If 0, the raw readback value
+ should be decreasing. |
-
- | drvOmsCom.h |
- Driver support header file common to all Oregon Micro Systems device
- drivers. |
+
+ | ATHM |
+ R |
+ At HOME |
+ SHORT |
+ The state of the hardware's "home" switch. If 1, the motor has hit the
+ switch. |
-
-
- |
- NOTE: The above files are required for any and all Oregon Micro Systems
- device drivers. |
+
+ | RCNT |
+ R |
+ Retry count |
+ SHORT |
+ The number of times the motor record has detected failure of the motor to
+ land within the retry-deadband distance of the desired position. |
-
-
- |
-
- |
+
+ | MISS |
+ R |
+ Ran out of retries |
+ SHORT |
+ If 1, the motor has failed to land on the desired position more than the
+ allowed number of times. This field will be reset the next time the motor
+ succeeds in reaching the desired position. |
-
- | devOms.c |
- Device support for Oregon Micro Systems VME8 and VME44 series boards |
+
+ | RVEL |
+ R |
+ Raw Velocity |
+ LONG |
+ Speed in steps per second that the motor actually is moving. |
-
- | drvOms.c |
- Driver for Oregon Micro Systems VME8 and VME44 series boards |
-
-
- | drvOms.h |
- Header included by devOms.c and drvOms.c |
-
-
-
- |
-
- |
-
-
- | devOms58.c |
- Device support for Oregon Micro Systems VME58 series boards |
-
-
- | drvOms58.c |
- Driver for Oregon Micro Systems VME58 series boards |
-
-
- | drvOms58.h |
- Header included by devOms58.c and drvOms58.c |
-
-
-
- |
-
- |
-
-
- | devV544.c |
- Device support for Highland Technology boards. |
-
-
- | drvV544.c |
- Driver for Highland Technology boards. |
-
-
- | drvV544.h |
- Header included by devV544.c and drvV544.c |
-
-
-
- |
-
- |
-
-
- | drvMMCom.h |
- Common header included by all Newport Motion Master device drivers. |
-
-
-
- |
- NOTE: The above files are required for any and all Newport Motion
-Master device drivers. |
-
-
- | devMM3000.c |
- Device support for Newport MM3000. |
-
-
- | drvMM3000.c |
- Driver for Newport MM3000. |
-
-
- | devMM4000.c |
- Device support for Newport MM4000. |
-
-
- | drvMM4000.c |
- Driver for Newport MM4000. |
-
-
- | devPM500.c |
- Device support for Newport PM500. |
-
-
- | drvPM500.c |
- Driver for Newport PM500. |
-
-
-
- |
-
- |
-
-
- | devSoft.c |
- Soft Channel device support. |
-
-
- | devSoftAux.c |
- Soft Channel device support (Note: CA and record access code cannot
- both reside in the same file; each defines (redefines) the DBR's.
-Hence, functions are split between this and the above file base on whether
-they are record oriented (devSoft.c) or CA oriented (devSoftAux.c). |
-
-
- | devSoft.h |
- Header included by devSoft.c and devSoftAux.c |
-
-
-
- |
-
- |
-
-
- | gpibIO.h |
- GPIB communication include file. |
-
-
- | gpibIO.c |
- GPIB interface via Hideos. |
-
-
- | serialIO.h |
- Serial communication include file. |
-
-
- | serialIOMPF.cc |
- Serial communication interface via MPF. |
-
-
-
- |
-
- |
-
-
- | drvIM483.h |
- Common header included by all IMS device drivers. |
-
-
- | dev483PL.c |
- Device support for IM483 in party line communication mode. |
-
-
- | dev483SM.c |
- Device support for IM483 in single mode communication mode. |
-
-
- | drv483PL.c |
- Driver for IM483 in party line communication mode. |
-
-
- | drv483SM.c |
- Driver for IM483 in single mode communication mode. |
-
-
-
- |
-
- |
-
-
-
- |
-
- |
-
-
- | Makefile.Vx |
- This file is not included in the distribution. However, the user must
- edit this file and add lines similar to the following:
- MOTOR_OBJS = motorRecord.o devOms.o drvOms.o devOms58.o drvOms58.o LIBNAME = mylib.o LIBOBJS = $(MOTOR_OBJS) $(other objects here)
- |
-
-
-
-
-
-
+
+
+
+
+
+
+
+ Servo fields
+
+
+
+
+
+
-
- ASCII FILES
- files to be placed in <top>/cat_ascii/ |
+
+ | PID related record fields accept only normalized
+ values (i.e., 0.0 <= value <= 1.0). Before sending them to the motor
+ controller, device support scales the record fields to valid motor controller
+ parameters,. Let the motor controller PID parameters be represented by CKP,
+ CKI and CKD; then the PID coefficients are converted from motor record fields to
+ controller parameters as follows:
+
+ For the MM4000; CKP = PCOF, CKI = ICOF and CKD = DCOF.
+ For all OMS controllers; CKP = 1999.9 * PCOF, CKI = 1999.9 * ICOF, CKD =
+ 1999.9 * DCOF.
+
+
+
+ Note the following:
+
+
+
+ -
+ When commanded to move the OMS control law is a PD loop, when it is holding a
+ position it is a PID loop.
+
+ -
+ The Proportional Gain cannot be turned off (i.e., set to zero) in an OMS
+ controller. The minimum value is PCOF = 0.00005 (CKP = 0.1). If the
+ user sets PCOF < 0.00005 for an OMS controller, device support silently
+ resets it to it's minimum value of 0.00005.
+
+
+
+ |
-
- | motorRecord.ascii |
- This file defines all of the fields for the motor record. |
+
+ |
+
+ Name
+
+ |
+
+
+ Access
+
+ |
+
+
+ Prompt
+
+ |
+
+
+ Data type
+
+ |
+
+
+ Comments
+
+ |
-
- | choiceRecMotor.ascii |
- This file defines all of the choice values for the motor record. |
+
+ | CNEN |
+ R/W |
+ Enable control |
+ RECCHOICE |
+ (0:"Disable", 1:"Enable") Enable/Disable closed-loop position control.
+ This field is active only if the GAIN_SUPPORT bit in the MSTA is true.
+ This field is set by both the user and device support. CNEN is set to Disable
+ by device support when it detects a motion controller error; e.g. maximum
+ following error exceeded. |
-
- | choiceMotor.h |
- This file is included by choiceRecMotor.ascii and by recMotor.c. |
+
+ | PCOF |
+ R/W |
+ Proportional Gain |
+ FLOAT |
+ Valid range; 0.0 <= PCOF <= 1.0 |
-
- | choiceRec.ascii |
- This file is not included in the distribution. However, the user must
- edit this file and add the line:
- #include <choiceRecMotor.ascii>
- |
+
+ | ICOF |
+ R/W |
+ Integral Gain |
+ FLOAT |
+ Valid range; 0.0 <= ICOF <= 1.0 |
-
- | dbRecType.ascii |
- This file is not included in the distribution. However, the user must
- edit this file and add the line:
- "motor"
- |
+
+ | DCOF |
+ R/W |
+ Derivative Gain |
+ FLOAT |
+ Valid range; 0.0 <= DCOF <= 1.0 |
-
- | devSup.ascii |
- This file is not included in the distribution. However, the user must
- edit this file and add the following lines:
- ! Device Support for motor record "motor" VME_IO "devOMS" "OMS VME8, VME44" "motor" VME_IO "devOms58" "OMS VME58" "motor" VME_IO "devV544" "Highland V544"
- |
-
-
- | drvSup.ascii |
- This file is not included in the distribution. However, the user must
- edit or create this file and add the following lines:
- ! Driver support for the OME VME58 motor controller "drvOms58"
- |
-
-
-
-
-
-
+
+
+
+
+
+
+
+
+
+ Alarm fields
+
+
-
- MEDM DISPLAY SCREENS
- files to be placed in <top>/<app>App/op/adl/ |
+
+ | Name |
+ Access |
+ Prompt |
+ Data type |
+ Comments |
-
- | motorx.adl |
- Small motor-control screen |
+
+ | HIHI |
+ R/W* |
+ Hihi Alarm Limit |
+ FLOAT |
-
- | motorx_tiny.adl |
- Tiny motor-control screen |
+
+ | LOLO |
+ R/W* |
+ Lolo Alarm Limit |
+ FLOAT |
-
- | motorx_more.adl |
- Medium motor-control screen |
+
+ | HIGH |
+ R/W* |
+ High Alarm Limit |
+ FLOAT |
-
- | motorx_setup.adl |
- Setup screen for a single motor |
+
+ | LOW |
+ R/W* |
+ Low Alarm Limit |
+ FLOAT |
-
- | motorx_all.adl |
- Debug screen for a single motor |
+
+ | HHSV |
+ R/W* |
+ Hihi Severity |
+ GBLCHOICE |
+ Not used. |
-
- These files build medm screens to access the motor
- record. To use one of them from the command line, type, for example
-
- medm -x -macro "P=XXX:,M=m1" motorx.adl
- where XXX:m1 is the name of a motor record in an IOC.
-
- These files can also be used as related displays from other
- medm screens by passing the argument "P=XXX:,M=m1"
- .
- |
+
+ | LLSV |
+ R/W* |
+ Lolo Severity |
+ GBLCHOICE |
+ Not used. |
-
-
-
-
-
+
+ | HSV |
+ R/W* |
+ High Severity |
+ GBLCHOICE |
+ Not used. |
+
+
+ | LSV |
+ R/W* |
+ Low Severity |
+ GBLCHOICE |
+ Not used. |
+
+
+ | HLSV |
+ R/W* |
+ HW Limit Switch Violation Severity |
+ GBLCHOICE |
+
+
+
+
+
+
+
+
+
+
+ Miscellaneous fields
+
-
-
- EPICS STARTUP FILES
- files to be placed in <top>/ioc/ioc<name>/ |
+
+ | Name |
+ Access |
+ Prompt |
+ Data type |
+ Comments |
-
- | st.cmdmv167 |
- Startup script |
+
+ | PREC |
+ R/W |
+ Display Precision |
+ SHORT |
+ The number of digits to the right of the decimal that are to be displayed by
+ MEDM and other channel-access clients. |
-
- A sample startup script, containing excerpts relevant to
- motors, is included in the distribution. Here is an annotated copy:
-
- ####################################################################### # vxWorks startup script to load and execute system (iocCore) software.
- Load standard EPICS software
-
- # the following should be loaded first - BEGIN ld < targetmv167/iocCore ld < targetmv167/drvSup ld < targetmv167/devSup ld < targetmv167/recSup # the following should be loaded first - END
- Load custom EPICS software (including motor support)
-
- ld < ../../stdApp/src/O.mv167/stdlib.o
- Motor-related debug switches
-
- recMotordebug = 0
#OMS vme8/vme44 debug switches devOMSdebug = 0 drvOMSdebug = 0
#OMS vme58 debug switches devOms58debug = 0 drvOms58debug = 0
#Highland Technology V544 debug switches devV544ebug = 0 drvV544debug = 0
- Motor-related databases
-
- # load this before loading any databases dbLoad "../../default.dctsdr"
#allstop dbLoadRecords("../../stdApp/gDb/allstop.db","P=tmm:") #motors dbLoadRecords("../../stdApp/gDb/m16.db","P=tmm:")
- Specify motor-controller board address, interrupt
- vector, etc.
-
+
+ | EGU |
+ R/W |
+ Engineering Units |
+ STRING |
+ String sent to channel-access clients who ask for engineering units. |
+
+
+ | VERS |
+ R |
+ Code Version |
+ FLOAT |
+ Version number of the recMotor.c code. |
+
+
+ | CARD |
+ R |
+ Card Number |
+ SHORT |
+ For VME based devices (i.e., OMS VME8/44, OMS VME58 and V544) this is the
+ VME card number, derived from the output link. Cards are numbered from zero
+ according to their VME addresses. Oregon Micro Systems series VME8 and
+ VME44 cards occur in the same series, since they are handled by the same driver.
+ Oregon Micro Systems VME58 cards are numbered separately, as are Highland
+ Technology V540 cards. This field is set to -1 for non-VME based device/drivers. |
+
+
+ Command Primitives The following three fields
+ comprise the Command Primitives feature. The command primitive record
+ fields are available to the user to send ASCII command primitives to the motor
+ control board at fixed, predefined, times. Each of the fields is defined
+ as a character string. Consult the motor controller manual for command
+ protocols. No error checking is done by the motor record or the device
+ driver to insure that the command strings are valid. Each field is terminated
+ by the device driver according to the command protocol. Command primitives
+ that result in a response from the motion control board are valid, but the
+ response is not processed. This feature is currently only available with
+ OMS VME8/44/58 or Newport MM4000 device support.
+
+ Device Directives
+
+
+
+ -
+ Valid only in the INIT, PREM and POST fields.
+
+ -
+ Must be identified by the following;
+
+
+
+ -
+ First character of a device directive string must be a '@'.
+
+ -
+ One or more characters followed by a terminating '@'; i.e., device directives
+ must have nonzero length.
+
+ -
+ Valid device directives:
+
+
+ -
+ In the INIT field; only "DPM_ON".
+
+ -
+ In the PREM field;, only "PUT(pvname, pv-value, delay in
+ seconds)".
+
+ -
+ In the POST field; only "PUT(pvname, pv-value)".
+
+
+ See Driver Power Monitoring below for the DPM_ON directive. The PUT
+ directive supports changing the value of a database variable. Note that
+ the PREM supports a delay argument, but that POST does not. The Readback
+ settle time field (DLY) should be used to create a time delay after the PV
+ specified in the POST field is written.
+
+
+ -
+ A valid device directive; currently, only "DPM_ON".
+
+
+ -
+ Device directive strings are stripped of valid device directives (including @'s)
+ and tested for nonzero length before being sent to the controller. For
+ example, given the INIT string, "@DPM_ON@HE", the device directive @DPM_ON@ is
+ stripped out before HE is sent to the controller.
+
+
+
+ Driver Power Monitoring
+
+ -
+ This feature is only available with the OMS VME58 device support.
+
+ -
+ The 8 User I/O signals are assigned to the 8 possible VME58 axes as follows:
+
+
+
+ User I/O #0 <> X axis
+ " " 1 <> Y "
+
+ ........................................
+ " " 7 <> S "
+
+ -
+ Drive-power monitoring defaults to disabled at boot-up. Request enabling
+ drive-power monitoring by entering the device directive "@DPM_ON@" command into
+ the motor record initialization field (i.e., INIT). The INIT field is
+ processed at record initialization (i.e., bootup), hence if there are no errors,
+ drive-power monitoring will be enabled after the next bootup.
+
+ -
+ Whenever a request is made to enable drive-power status monitoring, an error
+ check is made (using the VME58 "RB" command) to verify that the User I/O has
+ been configured as an input. The following message will appear in the
+ error log if a configuration error is detected; "Invalid VME58 configuration; RB
+ = 0x####", where "####" is the VME58's response to the RB command.
+
+ -
+ When drive-power status monitoring is enabled and a power failure is detected,
+ the device driver will respond by activating the the RA_OVERTRAVEL bit in the
+ MSTA. This results in either HLS or LLS being activated depending on the
+ DIR field. In addition, the following message will appear in the error log; "Drive
+ power failure at VME58 card#?? motor#??".
+
+
+
+ |
+
+
+ | INIT |
+ R/W |
+ Startup commands |
+ STRING |
+ Sent at record initialization. |
+
+
+ | PREM |
+ R/W |
+ Pre-move commands |
+ STRING |
+ Sent before every command string that causes motion. |
+
+
+ | POST |
+ R/W |
+ Post-move commands |
+ STRING |
+ Sent after a complete motion is finished or when an overtravel limit switch
+ is detected. |
+
+
+
+ | |
+ |
+ |
+ |
+ |
+
+
+
+ | LOCK |
+ R/W |
+ Soft Channel Position Lock |
+ RECCHOICE |
+ After a "hard" motor initiated move, Soft Channel device support
+ automatically synchronizes a "soft" motor's target position with a "hard" motor's
+ readback position. Soft Channel device support detects that the "hard" motor
+ has initiated the move when it sees the PV pointed to by DINP go false, while
+ the "soft" record's DMOV is true. Automatic synchronization is undesirable in a
+ multi-axis application. Hence, setting the LOCK field to "Yes" disables this
+ automatic synchronization. |
+
+
+
+ | NTM |
+ R/W |
+ New Target Monitor |
+ RECCHOICE |
+ The requirements on how the motor record processes a new target position
+ while the motor is in motion are as follows;
+ Case #1: The motor record is given a new position, which is in the opposite
+ direction from the current motor motion. If NTM is "Yes", the motor is
+ immediately stopped and given a motion command to the new position. If NTM is "No
+ ", the motor completes the previous move before it is given a motion command to
+ the new position.
+ Case #2: The motor record is given a new position, which is in the same
+ direction as the current motor motion, but the new position is closer to the
+ motor's current position than the original target position. If NTM is "Yes",
+ the motor is stopped after it has gone past the new position; then a command is
+ given to return to the new position. If NTM is "No", the motor completes the
+ previous move before it is given a motion command to the new position.
+ Case #3: The motor record is given a new position, which is in the same
+ direction as the current motor motion, but the new position is further from the
+ motor's current position than the original position. After the motor reaches
+ the original target position and stops, a command is given to the new target
+ position. This case is independent of NTM.
+ NTM defaults to "Yes". It should be set to "No" only for soft motors. Soft
+ motors should be configured with NTM set to "No" to prevent Case #1 above from
+ interfering with "hard" motors using backlash correction. |
+
+
+
+
+
+
+
+
+
+
+ Private fields
+
-
- omsSetup(nCards, Unused, baseAddress,
-intVectBase, intLevel, pollRate)
- oms58Setup(nCards, Unused, baseAddress, intVectBase,
-intLevel, pollRate)
- v544Setup(nCards, nAxes, baseAddress, intVectBase,
- intLevel, pollRate)
- MM3000Setup(nCards, Unused,
- pollRate)
- MM3000Config(card#, portType, GPIB link or hideos_card#,
-GPIB address or hideos_task name)
-
- MM4000Setup(nCards, Unused,
- pollRate)
- MM4000Config(card#, portType, GPIB link or hideos_card#,
-GPIB address or hideos_task name)
-
- IM483SMSetup(nCards, Unused,
- pollRate)
- IM483SMConfig(card#, portType, GPIB link or hideos_card#,
-GPIB address or hideos_task name)
-
- IM483[PL/SM]Setup(nCommNet, Unused,
- pollRate)
- IM483[PL/sm]Config(CommNet#, portType, GPIB link or
-hideos_card#, GPIB address or hideos_task name)
-
- |
+
+ | Name |
+ Access |
+ Prompt |
+ Data type |
+ Comments |
-
- | nCards |
- the actual number of cards may be less, but not greater than this |
+
+ | CBAK |
+ None |
+ Callback structure |
+ NOACCESS |
+
+ |
-
- | nCommNet |
- the number of Communication networks (e.g., the number of RS-422
- networks for a IM483PL device). |
+
+ | LVAL |
+ R |
+ Last User Des Val |
+ DOUBLE |
-
- | nAxes |
- the maximum number of motor axes controlled by any one card |
+
+ | LDVL |
+ R |
+ Last Dial Des Val |
+ DOUBLE |
-
- | baseAddress |
- the base address of the first card of a series. This must agree with
- address jumpers on the actual card(s).
- OMS VME8, VME44, and VMEX cards are all of one series,
-with a base address in the short address space, on a 16-byte (0x10) boundary.
-(I.e., these cards require 16 bytes each, and must all be addressed contiguously
-as, e.g., 0xFC00, 0xFC10).
-
- OMS VME58-x cards are in their own series, also in the
-short address space, on a 4k-byte (0x1000) boundary.
-
- Highland Technology V544 cards are in their own series,
-in the short address space, on a 128-byte (0x80) boundary.
- |
+
+ | LRVL |
+ R |
+ Last Raw Des Val |
+ DOUBLE |
-
- | intVectBase |
- the interrupt vector that will be loaded into the first card of a
-series. Succeeding cards will be loaded with intVectBase+1, intVectBase+2,
-etc. Set to "0" to disable interrupt generation; otherwise, stay in the range
-[64..255]. |
+
+ | LRLV |
+ R |
+ Last Rel Value |
+ DOUBLE |
-
- | intLevel |
- the VME-interrupt level (in [1..6]) the cards will use. This must
-agree with jumper settings on the cards. |
+
+ CDIR
+ |
+ R |
+ Command direction
+ |
+ SHORT
+ |
-
- | pollRate |
- the rate (in Hz.) at which the driver will interrogate a card when
-one of its motors is moving. This is also the rate at which channel-access
-monitors will be posted; to avoid saturating the network with motor-readback
-information, don't set pollRate much higher than 10 Hz. pollRate must be
-in the range [1..60]. |
+
+ | PP |
+ R |
+ Post process command |
+ SHORT |
-
- | portType |
- 0 - GPIB_PORT or 1 - RS232_PORT |
+
+ | MIP |
+ R |
+ Motion In Progress |
+ SHORT |
-
-
-
-
- # OMS VME8, VME44, VMEX driver setup parameters: omsSetup(5, 8, 0xFC00, 180, 5, 10)
# OMS VME58 driver setup parameters: oms58Setup(5, 8, 0x2000, 190, 5, 10)
# Highland Technology V544 driver setup parameters: v544Setup(5, 4, 0xDD00, 200, 5, 10)
- Start EPICS
- iocInit
- |
+
+ | MMAP |
+ R |
+ Monitor Mask |
+ ULONG |
-
-
-
-
-
+
+ | NMAP |
+ R |
+ Monitor Mask |
+ ULONG |
+
+
+ | LSPG |
+ R |
+ Last SPMG |
+ RECCHOICE |
+ (see SPMG) |
+
+
+
+
+
+
+
+
+
+
+Files, device support
The following table briefly describes all of the
+files required to implement and use the motor record. The reader is assumed to
+be familiar with the EPICS
+Application Source/Release Control document which describes how to build an
+EPICS application tree into which these files are to be placed, and how to run "makesdr
+" and "gnumake" to build the record support. These files can all be obtained
+from the EPICS
+Software Distribution (in the custom-software
+section ).
+
-
- BACKUP/RESTORE (BURT) REQUEST FILES
- files to be placed in <top>/<app>App/op/burt/ |
+
+ SOURCE CODE
+ files to be placed in <top>/<app>App/src/ |
-
- | settings.req |
- sample request file to save settings of all motors. Edit this file,
- supplying names of the motor records whose settings you want saved. (The
-sample file also saves the states of other records in the sample database,
-m16.db, that enable or disable the motor records.) |
+
+ | motorRecord.dbd |
+ Database Definition file for motor record. |
-
- | yyMotorSettings.req |
- save settings of a specified motor. This file is #include
-'d (once for each motor) by settings.req. |
+
+ | motorRecord.c |
+ Record support for the motor record |
-
- | positions.req |
- sample request file to save positions of all motors. Edit this file,
- supplying names of the motor records whose positions you want saved. |
+
+ | motor.h |
+ Header included by all .c files |
-
- | yyMotorPositions.req |
- save position of a specified motor, This file is #include
-'d (once for each motor) by positions.req. |
+
+
+ |
+
+ |
-
- These files tell the backup/restore tool how to save motor
- settings and positions. To use them from the command line, type, for example
-
- burtrb -f settings.req -o myMotorSettings.snap
burtrb -f positions.req -o myMotorPositions.snap
- To restore the motor settings and positions saved by the above commands,
- type
- burtwb -f myMotorSettings.snap
burtwb -f myMotorPositions.snap
- |
+
+ | motordevCom.c |
+ Device support common to all motor Record device drivers. |
-
-
-
-
-
-
- Restrictions
- You must not change the motor resolution while the motor is moving,
- but the record currently does not defend itself against this.
- There is no way to ask for a reading of the motor's position register,
- encoder, or limit switches. These are read only while the motor is moving.
-
-
- Because of the way limit-switch information is conveyed by the OMS
-hardware, the motor record cannot know the states of both limit switches at
-the same time. It only knows the state of the switch toward which the motor
-is moving.
-
- If a move is requested while the motor already is in motion, the original
- move will still receive a (useless) backlash correction.
-
- Changing MRES (the motor resolution) should change VELO (the speed
-in engineering units per second), and leave S (the speed in revolutions per
- second) unchanged. Currently, neither VELO nor S appears to change, but
-the record behaves as though S had been changed to agree with VELO. A similar
- thing happens with SBAK and SBAS.
-
-
-
-
-
- Examples
-
- Command Primitives
- This example assumes the controller is an MM4000 and that only one motor
- in the controller is moved at a time (MM4000 power on/off effects all motors).
- If the user wishes the system to perform as follows:
-
- - Boot-up with motor power off.
- - Turn motor power on before motor motion.
- - Turn motor power off after motor motion.
-
-
- Then set fields as follows:
-
- - INIT = "MF"
- - PREM = "MO"
- - POST = "MF"
-
-
-
- Soft Channel
- The following is a simple example of using soft channel device support
-to allow the user to transform rotary position commands into linear moves.
- This example assumes the system consist of a linear stage driving a tangent
- arm. The user commands the system in terms of the angle the arm makes
- with the vertical. The database converts this angle into a linear
-position along an axis that is one meter perpendicular to the center of rotation.
-
- The following database implements the system described above.
- The database consist of four records:
-
-
- - rotary - a soft motor record where the user issues angular
- position commands in degrees.
- - convertDriveValue - a calcout record that converts
-the commanded position from degrees to mm.
- - linear - a hard motor record using Oms58 device
-support that accepts linear position commands in mm.
- - convertReadbackValue - calcout record that converts
-the feedback position from mm to degrees.
-
-
- Note the following concerning the example database and Soft Channel device
- support:
-
- - Jogging a soft channel motor record is not supported.
- - In the convertReadbackValue record, CP is required in the
-INPA field to get continuous readback updates to the rotary record.
-Otherwise, the rotary record will only update at the end of a move.
- - The convertDriveValue record converts rotary's DVAL
-field from degrees to radians, takes the tangent, converts from meters to
-millimeters and finally, sends this value to linear's DVAL field
- .
- - The convertReadbackValue record converts linear's DRBV
-field from millimeters to meters, takes the inverse tangent and finally, converts
-from radians to degrees.
-
-
-
-
+
+ | motordevCom.h |
+ Device support header file. |
+
+
+ | motordrvCom.c |
+ Driver support common to all motor Record device drivers. |
+
+
+ | motordrvCom.h |
+ Driver support header file. |
+
+
+ | motordrvComCode.h |
+ Local variables common to all motor Record drivers. |
+
+
+
+ |
+ NOTE: All of the above files are required for any and all motor Record
+ device drivers. |
+
+
+
+ |
+
+ |
+
+
+ | devOmsCom.c |
+ Device support common to all Oregon Micro Systems device drivers. |
+
+
+ | devOmsCom.h |
+ Device support header file common to all Oregon Micro Systems device drivers. |
+
+
+ | drvOmsCom.h |
+ Driver support header file common to all Oregon Micro Systems device drivers. |
+
+
+
+ |
+ NOTE: The above files are required for any and all Oregon Micro Systems
+ device drivers. |
+
+
+
+ |
+
+ |
+
+
+ | devOms.c |
+ Device support for Oregon Micro Systems VME8 and VME44 series boards |
+
+
+ | drvOms.c |
+ Driver for Oregon Micro Systems VME8 and VME44 series boards |
+
+
+ | drvOms.h |
+ Header included by devOms.c and drvOms.c |
+
+
+
+ |
+
+ |
+
+
+ | devOms58.c |
+ Device support for Oregon Micro Systems VME58 series boards |
+
+
+ | drvOms58.c |
+ Driver for Oregon Micro Systems VME58 series boards |
+
+
+ | drvOms58.h |
+ Header included by devOms58.c and drvOms58.c |
+
+
+
+ |
+
+ |
+
+
+ | devV544.c |
+ Device support for Highland Technology boards. |
+
+
+ | drvV544.c |
+ Driver for Highland Technology boards. |
+
+
+ | drvV544.h |
+ Header included by devV544.c and drvV544.c |
+
+
+
+ |
+
+ |
+
+
+ | drvMMCom.h |
+ Common header included by all Newport Motion Master device drivers. |
+
+
+
+ |
+ NOTE: The above files are required for any and all Newport Motion Master
+ device drivers. |
+
+
+ | devMM3000.c |
+ Device support for Newport MM3000. |
+
+
+ | drvMM3000.c |
+ Driver for Newport MM3000. |
+
+
+ | devMM4000.c |
+ Device support for Newport MM4000. |
+
+
+ | drvMM4000.c |
+ Driver for Newport MM4000. |
+
+
+ | devPM500.c |
+ Device support for Newport PM500. |
+
+
+ | drvPM500.c |
+ Driver for Newport PM500. |
+
+
+
+ |
+
+ |
+
+
+ | devSoft.c |
+ Soft Channel device support. |
+
+
+ | devSoftAux.c |
+ Soft Channel device support (Note: CA and record access code cannot both
+ reside in the same file; each defines (redefines) the DBR's. Hence,
+ functions are split between this and the above file base on whether they are
+ record oriented (devSoft.c) or CA oriented (devSoftAux.c). |
+
+
+ | devSoft.h |
+ Header included by devSoft.c and devSoftAux.c |
+
+
+
+ |
+
+ |
+
+
+ | gpibIO.h |
+ GPIB communication include file. |
+
+
+ | gpibIO.c |
+ GPIB interface via Hideos. |
+
+
+ | serialIO.h |
+ Serial communication include file. |
+
+
+ | serialIOMPF.cc |
+ Serial communication interface via MPF. |
+
+
+
+ |
+
+ |
+
+
+ | drvIM483.h |
+ Common header included by all IMS device drivers. |
+
+
+ | devIM483PL.c |
+ Device support for IM483 in party line communication mode. |
+
+
+ | devIM483SM.c |
+ Device support for IM483 in single mode communication mode. |
+
+
+ | drvIM483PL.c |
+ Driver for IM483 in party line communication mode. |
+
+
+ | drvIM483SM.c |
+ Driver for IM483 in single mode communication mode. |
+
+
+
+ |
+
+ |
+
+
+
+ |
+
+ |
+
+
+ | Makefile.Vx |
+ This file is not included in the distribution. However, the user must edit
+ this file and add lines similar to the following:
+ MOTOR_OBJS = motorRecord.o devOms.o
+ drvOms.o devOms58.o drvOms58.o LIBNAME = mylib.o LIBOBJS = $(MOTOR_OBJS) $
+ (other objects here)
+ |
+
+
+
+
+
+
-
- grecord(motor,"$(user):rotary")
- {
- field(DTYP,"Soft Channel")
- field(OUT,"$(user):convertDriveValue.A PP MS")
-
- field(RDBL,"$(user):convertReadbackValue.VAL NPP
-MS")
- field(URIP,"Yes")
- field(STOO,"$(user):linear.STOP PP MS")
- field(DINP,"$(user):linear.DMOV NPP MS")
- field(MRES,"0.001")
- field(RRES,"1.000")
- field(PREC,"3")
- field(DHLM,"45")
- field(DLLM,"-45")
- field(TWV,"5")
- field(RTRY,"0")
- field(EGU,"deg.")
- } |
- grecord(motor,"$(user):linear")
- {
- field(DTYP,"OMS VME58")
- field(VBAS,"1.0")
- field(VELO,"25.0")
- field(OUT,"#C0 S0 @")
- field(MRES,"0.001")
- field(PREC,"3")
- field(DHLM,"1000")
- field(DLLM,"-1000")
- field(RTRY,"0")
- field(TWV,"1")
- field(EGU,"mm.")
- } |
+
+ ASCII FILES
+ files to be placed in <top>/cat_ascii/ |
-
- grecord(calcout,"$(user):convertDriveValue")
- {
- field(DESC,"Convert rotary to linear")
- field(CALC,"TAN(A / 57.296) * 1000")
- field(OUT,"$(user):linear.DVAL PP MS")
- } |
- grecord(calcout,"$(user):convertReadbackValue")
- {
- field(DESC,"Convert linear to rotary")
- field(CALC,"ATAN(A / 1000) * 57.296")
- field(INPA,"$(user):linear.DRBV CP MS")
- } |
+
+ | motorRecord.ascii |
+ This file defines all of the fields for the motor record. |
-
-
-
-
-
-
-
- Design Decisions
- This section of the document is an attempt to record the reasoning behind
- recent motor record design decisions.
- Motor Controller Travel Limits
- For those motor controllers that provide their own internal software travel
- limits (e.g., MM4000), the motor record will only allow the user to set
-dial travel limits (i.e., D[H/L]LM) that are within the controller's travel
-limit range, inclusively. In making this design decision it was assumed
-that an expert user would enter the controller travel limits (possibly,
- through a front panel user interface) that would protect other users from
- reaching the hard travel limits. Controllers with their own travel
-limits that are commanded to move outside their valid range respond with
-an error. Hence, there is no utility in allowing the dial travel limits
-outside the controller's range.
- Separate EGU's and MRES's between Controller and Motor Record
- Device driver support for controllers that have characteristics different
- from the OMS controllers, such as the Newport MM4000, has raised new issues.
- One of these issues is whether or not the motor record should set it's EGU
-and MRES fields from the controller's values. We think it should not.
-
- Background: The MM4000 is a stand-alone controller with it's own front
- panel, non-volatile memory and power supply. The user can configure
- the MM4000 entirely from the front panel; including which engineering units
- will be displayed on the front panel. Once engineering units are selected,
-these same units will be used by the MM4000 when communicating with a host
-system (i.e., EPICS). Since a host can query the MM4000 for both the
-controller's engineering units and it's positioning resolution, it is possible
-to have the motor record's EGU and MRES fields automatically set based on
-values stored in the MM4000 controller, but we decided not to do this.
-
- To maximize flexibility, we decided to keep these characteristics separate
-between the motor record and the controller. This decision allows the
-motor record EGU field (and consequently, MRES) to be set to an application
-specific value (e.g., kV) that is not supported by the motor controller.
-
-
-
-
-
-
-
- Suggestions and comments to:
-
- Ron Sluiter
- : (sluiter@aps.anl.gov)
- Tim Mooney
- : (mooney@aps.anl.gov)
- Joe Sullivan
- : (sullivan@aps.anl.gov)
- Last modified: July 12, 1999
-
-
+
+ | choiceRecMotor.ascii |
+ This file defines all of the choice values for the motor record. |
+
+
+ | choiceMotor.h |
+ This file is included by choiceRecMotor.ascii and by recMotor.c. |
+
+
+ | choiceRec.ascii |
+ This file is not included in the distribution. However, the user must edit
+ this file and add the line:
+ #include <choiceRecMotor.ascii>
+ |
+
+
+ | dbRecType.ascii |
+ This file is not included in the distribution. However, the user must edit
+ this file and add the line:
+ "motor"
+ |
+
+
+ | devSup.ascii |
+ This file is not included in the distribution. However, the user must edit
+ this file and add the following lines:
+ ! Device Support for motor record "motor" VME_IO
+ "devOMS" "OMS VME8, VME44" "motor"
+ VME_IO "devOms58" "OMS VME58" "motor"
+ VME_IO "devV544" "Highland V544"
+ |
+
+
+ | drvSup.ascii |
+ This file is not included in the distribution. However, the user must edit
+ or create this file and add the following lines:
+ ! Driver support for the OME VME58 motor controller "drvOms58"
+ |
+
+
+
+
+
+
+
+
+ MEDM DISPLAY SCREENS
+ files to be placed in <top>/<app>App/op/adl/ |
+
+
+ | motorx.adl |
+ Small motor-control screen |
+
+
+ | motorx_tiny.adl |
+ Tiny motor-control screen |
+
+
+ | motorx_more.adl |
+ Medium motor-control screen |
+
+
+ | motorx_setup.adl |
+ Setup screen for a single motor |
+
+
+ | motorx_all.adl |
+ Debug screen for a single motor |
+
+
+ These files build medm screens to access the motor
+ record. To use one of them from the command line, type, for example
+
+ medm -x -macro "P=XXX:,M=m1" motorx.adl
+ where XXX:m1 is the name of a motor record in an IOC.
+
+
+ These files can also be used as related displays from other medm
+ screens by passing the argument "P=XXX:,M=m1" .
+
+ |
+
+
+
+
+
+
+
+
+
+ EPICS STARTUP FILES
+ files to be placed in <top>/ioc/ioc<name>/ |
+
+
+ | st.cmdmv167 |
+ Startup script |
+
+
+ A sample startup script, containing excerpts relevant to motors,
+ is included in the distribution. Here is an annotated copy:
+
+ #######################################################################
+ # vxWorks startup script to load and execute system (iocCore) software.
+ Load standard EPICS software
+
+ # the following should be loaded first - BEGIN ld < targetmv167/
+ iocCore ld < targetmv167/drvSup ld < targetmv167/devSup ld <
+ targetmv167/recSup # the following should be loaded first - END
+ Load custom EPICS software (including motor support)
+
+ ld < ../../stdApp/src/O.mv167/stdlib.o
+ Motor-related debug switches
+
+ recMotordebug = 0
#OMS vme8/vme44 debug switches devOMSdebug = 0
+ drvOMSdebug = 0
#OMS vme58 debug switches devOms58debug = 0
+ drvOms58debug = 0
#Highland Technology V544 debug switches devV544ebug
+ = 0 drvV544debug = 0
+ Motor-related databases
+
+ # load this before loading any databases dbLoad "../../default.dctsdr"
+ #allstop dbLoadRecords("../../stdApp/gDb/allstop.db","P=tmm:") #motors
+ dbLoadRecords("../../stdApp/gDb/m16.db","P=tmm:")
+ Specify motor-controller board address, interrupt
+ vector, etc.
+
+
+
+ omsSetup(nCards, Unused, baseAddress,
+ intVectBase, intLevel, pollRate)
+ oms58Setup(nCards, Unused, baseAddress, intVectBase, intLevel,
+ pollRate)
+ v544Setup(nCards, nAxes, baseAddress, intVectBase, intLevel,
+ pollRate)
+
+ MM3000Setup(nCards, Unused,
+ pollRate)
+ MM3000Config(card#, portType, GPIB link or hideos_card#, GPIB address or
+ hideos_task name)
+
+
+
+ MM4000Setup(nCards, Unused,
+ pollRate)
+ MM4000Config(card#, portType, GPIB link or hideos_card#, GPIB address or
+ hideos_task name)
+
+
+
+ IM483SMSetup(nCards, Unused,
+ pollRate)
+ IM483SMConfig(card#, portType, GPIB link or hideos_card#, GPIB address or
+ hideos_task name)
+
+
+
+ IM483[PL/SM]Setup(nCommNet, Unused,
+ pollRate)
+ IM483[PL/sm]Config(CommNet#, portType, GPIB link or hideos_card#, GPIB
+ address or hideos_task name)
+
+
+ |
+
+
+ | nCards |
+ the actual number of cards may be less, but not greater than this |
+
+
+ | nCommNet |
+ the number of Communication networks (e.g., the number of RS-422
+ networks for a IM483PL device). |
+
+
+ | nAxes |
+ the maximum number of motor axes controlled by any one card |
+
+
+ | baseAddress |
+ the base address of the first card of a series. This must agree with address
+ jumpers on the actual card(s).
+
+ OMS VME8, VME44, and VMEX cards are all of one series, with a base address in
+ the short address space, on a 16-byte (0x10) boundary. (I.e., these cards
+ require 16 bytes each, and must all be addressed contiguously as, e.g., 0xFC00,
+ 0xFC10).
+
+
+
+ OMS VME58-x cards are in their own series, also in the short address space, on a
+ 4k-byte (0x1000) boundary.
+
+
+
+ Highland Technology V544 cards are in their own series, in the short address
+ space, on a 128-byte (0x80) boundary.
+
+ |
+
+
+ | intVectBase |
+ the interrupt vector that will be loaded into the first card of a series.
+ Succeeding cards will be loaded with intVectBase+1, intVectBase+2, etc. Set to "0
+ " to disable interrupt generation; otherwise, stay in the range [64..255]. |
+
+
+ | intLevel |
+ the VME-interrupt level (in [1..6]) the cards will use. This must agree with
+ jumper settings on the cards. |
+
+
+ | pollRate |
+ the rate (in Hz.) at which the driver will interrogate a card when one of
+ its motors is moving. This is also the rate at which channel-access monitors
+ will be posted; to avoid saturating the network with motor-readback information,
+ don't set pollRate much higher than 10 Hz. pollRate must be in the range [1..60]. |
+
+
+ | portType |
+ 0 - GPIB_PORT or 1 - RS232_PORT |
+
+
+
+
+
+ # OMS VME8, VME44, VMEX driver setup parameters: omsSetup(5, 8, 0xFC00,
+ 180, 5, 10)
# OMS VME58 driver setup parameters: oms58Setup(5, 8,
+ 0x2000, 190, 5, 10)
# Highland Technology V544 driver setup parameters:
+ v544Setup(5, 4, 0xDD00, 200, 5, 10)
+ Start EPICS
+ iocInit
+ |
+
+
+
+
+
+
+
+
+ BACKUP/RESTORE (BURT) REQUEST FILES
+ files to be placed in <top>/<app>App/op/burt/ |
+
+
+ | settings.req |
+ sample request file to save settings of all motors. Edit this file,
+ supplying names of the motor records whose settings you want saved. (The sample
+ file also saves the states of other records in the sample database, m16.db, that
+ enable or disable the motor records.) |
+
+
+ | yyMotorSettings.req |
+ save settings of a specified motor. This file is #include 'd (once
+ for each motor) by settings.req. |
+
+
+ | positions.req |
+ sample request file to save positions of all motors. Edit this file,
+ supplying names of the motor records whose positions you want saved. |
+
+
+ | yyMotorPositions.req |
+ save position of a specified motor, This file is #include 'd (once
+ for each motor) by positions.req. |
+
+
+ These files tell the backup/restore tool how to save motor
+ settings and positions. To use them from the command line, type, for example
+
+ burtrb -f settings.req -o myMotorSettings.snap
burtrb -f positions.
+ req -o myMotorPositions.snap
+ To restore the motor settings and positions saved by the above commands, type
+ burtwb -f myMotorSettings.snap
burtwb -f myMotorPositions.snap
+ |
+
+
+
+
+
+
+
+
+Restrictions
You must not change the motor resolution while the
+motor is moving, but the record currently does not defend itself against this.
+
+There is no way to ask for a reading of the motor's position register, encoder,
+or limit switches. These are read only while the motor is moving.
+
+
+
+Because of the way limit-switch information is conveyed by the OMS hardware, the
+motor record cannot know the states of both limit switches at the same time. It
+only knows the state of the switch toward which the motor is moving.
+
+
+
+If a move is requested while the motor already is in motion, the original move
+will still receive a (useless) backlash correction.
+
+
+
+Changing MRES (the motor resolution) should change VELO (the speed in
+engineering units per second), and leave S (the speed in revolutions per second)
+unchanged. Currently, neither VELO nor S appears to change, but the record
+behaves as though S had been changed to agree with VELO. A similar thing happens
+with SBAK and SBAS.
+
+
+
+
+
+
+Examples
+
+Command Primitives
This example assumes the controller is an MM4000 and
+that only one motor in the controller is moved at a time (MM4000 power on/off
+effects all motors). If the user wishes the system to perform as follows:
+
+ -
+ Boot-up with motor power off.
+
+ -
+ Turn motor power on before motor motion.
+
+ -
+ Turn motor power off after motor motion.
+
+
+
+Then set fields as follows:
+
+ -
+ INIT = "MF"
+
+ -
+ PREM = "MO"
+
+ -
+ POST = "MF"
+
+
+
+
+Soft Channel
The following is a simple example of using soft channel
+device support to allow the user to transform rotary position commands into
+linear moves. This example assumes the system consist of a linear stage
+driving a tangent arm. The user commands the system in terms of the angle
+the arm makes with the vertical. The database converts this angle into a
+linear position along an axis that is one meter perpendicular to the center of
+rotation.
+
+
+The following database implements the system described above. The database
+consist of four records:
+
+
+
+ -
+ rotary - a soft motor record where the user issues angular
+ position commands in degrees.
+
+ -
+ convertDriveValue - a calcout record that converts the commanded
+ position from degrees to mm.
+
+ -
+ linear - a hard motor record using Oms58 device support that
+ accepts linear position commands in mm.
+
+ -
+ convertReadbackValue - calcout record that converts the feedback
+ position from mm to degrees.
+
+
+
+Note the following concerning the example database and Soft Channel device
+support:
+
+ -
+ Jogging a soft channel motor record is not supported.
+
+ -
+ In the convertReadbackValue record, CP is required in the INPA field to
+ get continuous readback updates to the rotary record. Otherwise,
+ the rotary record will only update at the end of a move.
+
+ -
+ The convertDriveValue record converts rotary's DVAL field from
+ degrees to radians, takes the tangent, converts from meters to millimeters and
+ finally, sends this value to linear's DVAL field.
+
+ -
+ The convertReadbackValue record converts linear's DRBV field from
+ millimeters to meters, takes the inverse tangent and finally, converts from
+ radians to degrees.
+
+
+
+
+
+
+
+ grecord(motor,"$(user):rotary")
+ {
+ field(DTYP,"Soft Channel")
+ field(OUT,"$(user):convertDriveValue.A PP MS")
+ field(RDBL,"$(user):convertReadbackValue.VAL NPP MS")
+ field(URIP,"Yes")
+ field(STOO,"$(user):linear.STOP PP MS")
+ field(DINP,"$(user):linear.DMOV NPP MS")
+ field(MRES,"0.001")
+ field(RRES,"1.000")
+ field(PREC,"3")
+ field(DHLM,"45")
+ field(DLLM,"-45")
+ field(TWV,"5")
+ field(RTRY,"0")
+ field(EGU,"deg.")
+ } |
+ grecord(motor,"$(user):linear")
+ {
+ field(DTYP,"OMS VME58")
+ field(VBAS,"1.0")
+ field(VELO,"25.0")
+ field(OUT,"#C0 S0 @")
+ field(MRES,"0.001")
+ field(PREC,"3")
+ field(DHLM,"1000")
+ field(DLLM,"-1000")
+ field(RTRY,"0")
+ field(TWV,"1")
+ field(EGU,"mm.")
+ } |
+
+
+ grecord(calcout,"$(user):convertDriveValue")
+ {
+ field(DESC,"Convert rotary to linear")
+ field(CALC,"TAN(A / 57.296) * 1000")
+ field(OUT,"$(user):linear.DVAL PP MS")
+ } |
+ grecord(calcout,"$(user):convertReadbackValue")
+ {
+ field(DESC,"Convert linear to rotary")
+ field(CALC,"ATAN(A / 1000) * 57.296")
+ field(INPA,"$(user):linear.DRBV CP MS")
+ } |
+
+
+
+
+
+
+
+
+
+Design Decisions
+
+This section of the document is an attempt to record the reasoning behind recent
+motor record design decisions. Motor Controller Travel Limits
For those
+motor controllers that provide their own internal software travel limits (e.g.,
+MM4000), the motor record will only allow the user to set dial travel limits (i.e.,
+D[H/L]LM) that are within the controller's travel limit range, inclusively.
+In making this design decision it was assumed that an expert user would
+enter the controller travel limits (possibly, through a front panel user
+interface) that would protect other users from reaching the hard travel limits.
+Controllers with their own travel limits that are commanded to move outside
+their valid range respond with an error. Hence, there is no utility in
+allowing the dial travel limits outside the controller's range. Separate EGU's
+and MRES's between Controller and Motor Record
Device driver support for
+controllers that have characteristics different from the OMS controllers, such
+as the Newport MM4000, has raised new issues. One of these issues is
+whether or not the motor record should set it's EGU and MRES fields from the
+controller's values. We think it should not.
+
+
+Background: The MM4000 is a stand-alone controller with it's own front panel,
+non-volatile memory and power supply. The user can configure the MM4000
+entirely from the front panel; including which engineering units will be
+displayed on the front panel. Once engineering units are selected, these
+same units will be used by the MM4000 when communicating with a host system (i.e.,
+EPICS). Since a host can query the MM4000 for both the controller's
+engineering units and it's positioning resolution, it is possible to have the
+motor record's EGU and MRES fields automatically set based on values stored in
+the MM4000 controller, but we decided not to do this.
+
+
+
+To maximize flexibility, we decided to keep these characteristics separate
+between the motor record and the controller. This decision allows the
+motor record EGU field (and consequently, MRES) to be set to an application
+specific value (e.g., kV) that is not supported by the motor controller.
+
+
+
+
+
+
+
+
+Suggestions and comments to:
+Ron Sluiter : (sluiter@aps.anl.gov)
+Tim Mooney : (mooney@aps.anl.gov)
+Joe Sullivan : (sullivan@aps.anl.gov)
+Last modified: June 9, 2003
+
+