diff --git a/documentation/motorRecord.html b/documentation/motorRecord.html
index 9ded5f88..087283de 100644
--- a/documentation/motorRecord.html
+++ b/documentation/motorRecord.html
@@ -35,7 +35,7 @@
-
Overview
This documentation describes version R6-9 of the EPICS motor
+Overview
This documentation describes version R6-10 of the EPICS motor
record, and related EPICS software required to build and use it. Version
R6-9 of the motor record is compatible with EPICS base R3.14.12.2 and above.
@@ -61,7 +61,7 @@ Channel support):
Mclennan models PM304 and PM600.
- Physik Instrumente (PI) GmbH & Co. models; C-630/844/848/862/863, E-662/710/816, micos SMC hydra and all GCS2 (General Command Set) compatible controllers.
+ Physik Instrumente (PI) GmbH & Co. models; C-630/662/663/844/848/862/863, E-516/517/710/816, micos SMC hydra and all GCS2 (General Command Set) compatible controllers.
MicroMo model MVP 2001 B02.
@@ -76,7 +76,7 @@ Channel support):
Parker Hannifin, Compumotor Division, 6K Series controllers.
- New Focus, models; 8750 and 8752.
+ New Focus, models; 8750, 8752, & 874x.
ACS Motion Control, SPiiPlus model.
@@ -533,6 +533,14 @@ below.
|
+
+ | IGSET |
+ R/W |
+ Ignore SET Field |
+ SHORT |
+ (0:Normal operation, 1: SET is ignored)
+ |
+
| INIT |
R/W |
@@ -1336,6 +1344,14 @@ below.
SHORT |
Set Set/Use switch to "Use". |
+
+ | IGSET |
+ R/W |
+ Ignore SET Field |
+ SHORT |
+ (0:Normal operation, 1: SET is ignored)
+ |
+
| SET is a toggle switch used in calibrating the motor's user and
dial positions:
@@ -1356,6 +1372,16 @@ below.
LLM). When the offset is frozen (FOFF=1), writes to any drive field affect both
user and dial values, and also load the hardware position register.
+
+
+ When IGSET = 0, the motor record will obey the SET field and behave as described above.
+
+
+
+ When IGSET = 1, the motor record will behave as though SET = 0. Ignoring the SET
+ field can useful for applications with soft motors (motors with soft-channel device
+ support).
+
|