Added analog input support for temperature

This commit is contained in:
John Winans
1995-01-09 20:52:02 +00:00
parent 8bbe24525b
commit e7e77e415f

View File

@@ -59,6 +59,9 @@
* ...
*
* $Log$
* Revision 1.7 1995/01/09 20:28:42 winans
* Added AI support for temperature input
*
* Revision 1.6 1995/01/06 16:55:04 winans
* enabled irq services and rearranged the parm names and meanings.
*
@@ -261,13 +264,24 @@ struct dset_sysmon {
};
typedef struct dset_sysmon DSET_SYSMON;
DSET_SYSMON devAiSysmon={
5,
struct{
long number;
DEVSUPFUN report; /* used by dbior */
DEVSUPFUN init; /* called 1 time before & after all records */
DEVSUPFUN init_record; /* called 1 time for each record */
DEVSUPFUN get_ioint_info; /* used for COS processing */
DEVSUPFUN read_write; /* output command goes here */
DEVSUPFUN dumb_lincov_thing;
}
devAiSysmon=
{
6,
NULL,
SysmonInit,
SysmonInitAiRec,
NULL,
SysmonReadAi
SysmonReadAi,
NULL
};
DSET_SYSMON devBoSysmon={