# Copyright (c) 2002 The University of Chicago, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE Versions 3.13.7
# and higher are distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
menu(calcoutOOPT) {
choice(calcoutOOPT_Every_Time,"Every Time")
choice(calcoutOOPT_On_Change,"On Change")
choice(calcoutOOPT_When_Zero,"When Zero")
choice(calcoutOOPT_When_Non_zero,"When Non-zero")
choice(calcoutOOPT_Transition_To_Zero,"Transition To Zero")
choice(calcoutOOPT_Transition_To_Non_zero,"Transition To Non-zero")
}
menu(calcoutDOPT) {
choice(calcoutDOPT_Use_VAL,"Use CALC")
choice(calcoutDOPT_Use_OVAL,"Use OCAL")
}
menu(calcoutINAP) {
choice(calcoutINAP_No,"No PROC on Change")
choice(calcoutINAP_Yes,"PROC on Change")
}
menu(calcoutINAV) {
choice(calcoutINAV_EXT_NC,"Ext PV NC")
choice(calcoutINAV_EXT,"Ext PV OK")
choice(calcoutINAV_LOC,"Local PV")
choice(calcoutINAV_CON,"Constant")
}
recordtype(calcout) {
include "dbCommon.dbd"
field(VERS,DBF_DOUBLE) {
prompt("Code Version")
special(SPC_NOMOD)
initial("1")
}
field(RPVT,DBF_NOACCESS) {
prompt("Record Private")
special(SPC_NOMOD)
interest(4)
extra("void * rpvt")
}
field(VAL,DBF_DOUBLE) {
prompt("Result")
promptgroup(GUI_OUTPUT)
asl(ASL0)
}
field(PVAL,DBF_DOUBLE) {
prompt("Previous Value")
}
field(CALC,DBF_STRING) {
prompt("Calculation")
promptgroup(GUI_CALC)
special(SPC_CALC)
pp(TRUE)
size(36)
}
field(CLCV,DBF_LONG) {
prompt("CALC Valid")
interest(1)
}
field(INPA,DBF_INLINK) {
prompt("Input A")
special(SPC_MOD)
promptgroup(GUI_CALC)
interest(1)
}
field(INPB,DBF_INLINK) {
prompt("Input B")
special(SPC_MOD)
promptgroup(GUI_CALC)
interest(1)
}
field(INPC,DBF_INLINK) {
prompt("Input C")
special(SPC_MOD)
promptgroup(GUI_CALC)
interest(1)
}
field(INPD,DBF_INLINK) {
prompt("Input D")
special(SPC_MOD)
promptgroup(GUI_CALC)
interest(1)
}
field(INPE,DBF_INLINK) {
prompt("Input E")
special(SPC_MOD)
promptgroup(GUI_CALC)
interest(1)
}
field(INPF,DBF_INLINK) {
prompt("Input F")
special(SPC_MOD)
promptgroup(GUI_CALC)
interest(1)
}
field(INPG,DBF_INLINK) {
prompt("Input G")
special(SPC_MOD)
promptgroup(GUI_CALC)
interest(1)
}
field(INPH,DBF_INLINK) {
prompt("Input H")
special(SPC_MOD)
promptgroup(GUI_CALC)
interest(1)
}
field(INPI,DBF_INLINK) {
prompt("Input I")
special(SPC_MOD)
promptgroup(GUI_CALC)
interest(1)
}
field(INPJ,DBF_INLINK) {
prompt("Input J")
special(SPC_MOD)
promptgroup(GUI_CALC)
interest(1)
}
field(INPK,DBF_INLINK) {
prompt("Input K")
special(SPC_MOD)
promptgroup(GUI_CALC)
interest(1)
}
field(INPL,DBF_INLINK) {
prompt("Input L")
special(SPC_MOD)
promptgroup(GUI_CALC)
interest(1)
}
field(OUT,DBF_OUTLINK) {
prompt("Output Specification")
special(SPC_MOD)
promptgroup(GUI_OUTPUT)
interest(1)
}
field(INAV,DBF_MENU) {
prompt("INPA PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INBV,DBF_MENU) {
prompt("INPB PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INCV,DBF_MENU) {
prompt("INPC PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INDV,DBF_MENU) {
prompt("INPD PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INEV,DBF_MENU) {
prompt("INPE PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INFV,DBF_MENU) {
prompt("INPF PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INGV,DBF_MENU) {
prompt("INPG PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INHV,DBF_MENU) {
prompt("INPH PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INIV,DBF_MENU) {
prompt("INPI PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INJV,DBF_MENU) {
prompt("INPJ PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INKV,DBF_MENU) {
prompt("INPK PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INLV,DBF_MENU) {
prompt("INPL PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(OUTV,DBF_MENU) {
prompt("OUT PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
}
# Haven't figured out how to do this yet ...
# field(INAP,DBF_MENU) {
# prompt("INPA causes PROC")
# promptgroup(GUI_CALC)
# interest(1)
# menu(calcoutINAP)
# initial("0")
# }
# field(INBP,DBF_MENU) {
# prompt("INPB causes PROC")
# promptgroup(GUI_CALC)
# interest(1)
# menu(calcoutINAP)
# initial("0")
# }
# field(INCP,DBF_MENU) {
# prompt("INPC causes PROC")
# promptgroup(GUI_CALC)
# interest(1)
# menu(calcoutINAP)
# initial("0")
# }
# field(INDP,DBF_MENU) {
# prompt("INPD causes PROC")
# promptgroup(GUI_CALC)
# interest(1)
# menu(calcoutINAP)
# initial("0")
# }
# field(INEP,DBF_MENU) {
# prompt("INPE causes PROC")
# promptgroup(GUI_CALC)
# interest(1)
# menu(calcoutINAP)
# initial("0")
# }
# field(INFP,DBF_MENU) {
# prompt("INPF causes PROC")
# promptgroup(GUI_CALC)
# interest(1)
# menu(calcoutINAP)
# initial("0")
# }
# field(INGP,DBF_MENU) {
# prompt("INPG causes PROC")
# promptgroup(GUI_CALC)
# interest(1)
# menu(calcoutINAP)
# initial("0")
# }
# field(INHP,DBF_MENU) {
# prompt("INPH causes PROC")
# promptgroup(GUI_CALC)
# interest(1)
# menu(calcoutINAP)
# initial("0")
# }
# field(INIP,DBF_MENU) {
# prompt("INPI causes PROC")
# promptgroup(GUI_CALC)
# interest(1)
# menu(calcoutINAP)
# initial("0")
# }
# field(INJP,DBF_MENU) {
# prompt("INPJ causes PROC")
# promptgroup(GUI_CALC)
# interest(1)
# menu(calcoutINAP)
# initial("0")
# }
field(OOPT,DBF_MENU) {
prompt("Output Execute Opt")
promptgroup(GUI_CALC)
interest(1)
menu(calcoutOOPT)
}
field(ODLY,DBF_DOUBLE) {
prompt("Output Execute Delay")
promptgroup(GUI_ALARMS)
asl(ASL0)
interest(1)
}
field(DLYA,DBF_USHORT) {
prompt("Output Delay Active")
special(SPC_NOMOD)
asl(ASL0)
}
field(DOPT,DBF_MENU) {
prompt("Output Data Opt")
promptgroup(GUI_CALC)
interest(1)
menu(calcoutDOPT)
}
field(OCAL,DBF_STRING) {
prompt("Output Calculation")
promptgroup(GUI_CALC)
special(SPC_CALC)
pp(TRUE)
size(36)
}
field(OCLV,DBF_LONG) {
prompt("OCAL Valid")
interest(1)
}
field(OEVT,DBF_USHORT) {
prompt("Event To Issue")
promptgroup(GUI_CLOCK)
asl(ASL0)
}
field(IVOA,DBF_MENU) {
prompt("INVALID output action")
promptgroup(GUI_OUTPUT)
interest(2)
menu(menuIvoa)
}
field(IVOV,DBF_DOUBLE) {
prompt("INVALID output value")
promptgroup(GUI_OUTPUT)
interest(2)
}
field(EGU,DBF_STRING) {
prompt("Units Name")
promptgroup(GUI_DISPLAY)
interest(1)
size(16)
}
field(PREC,DBF_SHORT) {
prompt("Display Precision")
promptgroup(GUI_DISPLAY)
interest(1)
}
field(HOPR,DBF_DOUBLE) {
prompt("High Operating Rng")
promptgroup(GUI_DISPLAY)
interest(1)
}
field(LOPR,DBF_DOUBLE) {
prompt("Low Operating Range")
promptgroup(GUI_DISPLAY)
interest(1)
}
field(HIHI,DBF_DOUBLE) {
prompt("Hihi Alarm Limit")
promptgroup(GUI_ALARMS)
pp(TRUE)
interest(1)
}
field(LOLO,DBF_DOUBLE) {
prompt("Lolo Alarm Limit")
promptgroup(GUI_ALARMS)
pp(TRUE)
interest(1)
}
field(HIGH,DBF_DOUBLE) {
prompt("High Alarm Limit")
promptgroup(GUI_ALARMS)
pp(TRUE)
interest(1)
}
field(LOW,DBF_DOUBLE) {
prompt("Low Alarm Limit")
promptgroup(GUI_ALARMS)
pp(TRUE)
interest(1)
}
field(HHSV,DBF_MENU) {
prompt("Hihi Severity")
promptgroup(GUI_ALARMS)
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(LLSV,DBF_MENU) {
prompt("Lolo Severity")
promptgroup(GUI_ALARMS)
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(HSV,DBF_MENU) {
prompt("High Severity")
promptgroup(GUI_ALARMS)
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(LSV,DBF_MENU) {
prompt("Low Severity")
promptgroup(GUI_ALARMS)
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(HYST,DBF_DOUBLE) {
prompt("Alarm Deadband")
promptgroup(GUI_ALARMS)
interest(1)
}
field(ADEL,DBF_DOUBLE) {
prompt("Archive Deadband")
promptgroup(GUI_DISPLAY)
interest(1)
}
field(MDEL,DBF_DOUBLE) {
prompt("Monitor Deadband")
promptgroup(GUI_DISPLAY)
interest(1)
}
field(A,DBF_DOUBLE) {
prompt("Value of Input A")
pp(TRUE)
}
field(B,DBF_DOUBLE) {
prompt("Value of Input B")
pp(TRUE)
}
field(C,DBF_DOUBLE) {
prompt("Value of Input C")
pp(TRUE)
}
field(D,DBF_DOUBLE) {
prompt("Value of Input D")
pp(TRUE)
}
field(E,DBF_DOUBLE) {
prompt("Value of Input E")
pp(TRUE)
}
field(F,DBF_DOUBLE) {
prompt("Value of Input F")
pp(TRUE)
}
field(G,DBF_DOUBLE) {
prompt("Value of Input G")
pp(TRUE)
}
field(H,DBF_DOUBLE) {
prompt("Value of Input H")
pp(TRUE)
}
field(I,DBF_DOUBLE) {
prompt("Value of Input I")
pp(TRUE)
}
field(J,DBF_DOUBLE) {
prompt("Value of Input J")
pp(TRUE)
}
field(K,DBF_DOUBLE) {
prompt("Value of Input K")
pp(TRUE)
}
field(L,DBF_DOUBLE) {
prompt("Value of Input L")
pp(TRUE)
}
field(OVAL,DBF_DOUBLE) {
prompt("Output Value")
asl(ASL0)
}
field(LA,DBF_DOUBLE) {
prompt("Prev Value of A")
special(SPC_NOMOD)
interest(3)
}
field(LB,DBF_DOUBLE) {
prompt("Prev Value of B")
special(SPC_NOMOD)
interest(3)
}
field(LC,DBF_DOUBLE) {
prompt("Prev Value of C")
special(SPC_NOMOD)
interest(3)
}
field(LD,DBF_DOUBLE) {
prompt("Prev Value of D")
special(SPC_NOMOD)
interest(3)
}
field(LE,DBF_DOUBLE) {
prompt("Prev Value of E")
special(SPC_NOMOD)
interest(3)
}
field(LF,DBF_DOUBLE) {
prompt("Prev Value of F")
special(SPC_NOMOD)
interest(3)
}
field(LG,DBF_DOUBLE) {
prompt("Prev Value of G")
special(SPC_NOMOD)
interest(3)
}
field(LH,DBF_DOUBLE) {
prompt("Prev Value of H")
special(SPC_NOMOD)
interest(3)
}
field(LI,DBF_DOUBLE) {
prompt("Prev Value of I")
special(SPC_NOMOD)
interest(3)
}
field(LJ,DBF_DOUBLE) {
prompt("Prev Value of J")
special(SPC_NOMOD)
interest(3)
}
field(LK,DBF_DOUBLE) {
prompt("Prev Value of K")
special(SPC_NOMOD)
interest(3)
}
field(LL,DBF_DOUBLE) {
prompt("Prev Value of L")
special(SPC_NOMOD)
interest(3)
}
field(POVL,DBF_DOUBLE) {
prompt("Prev Value of OVAL")
asl(ASL0)
}
field(LALM,DBF_DOUBLE) {
prompt("Last Value Alarmed")
special(SPC_NOMOD)
interest(3)
}
field(ALST,DBF_DOUBLE) {
prompt("Last Value Archived")
special(SPC_NOMOD)
interest(3)
}
field(MLST,DBF_DOUBLE) {
prompt("Last Val Monitored")
special(SPC_NOMOD)
interest(3)
}
field(RPCL,DBF_NOACCESS) {
prompt("Reverse Polish Calc")
special(SPC_NOMOD)
interest(4)
extra("char rpcl[184]")
}
field(ORPC,DBF_NOACCESS) {
prompt("Reverse Polish OCalc")
special(SPC_NOMOD)
interest(4)
extra("char orpc[184]")
}
}