extend calc records and expressions to inputs A-U

This commit is contained in:
2025-05-22 16:34:16 +02:00
parent 1804bcef7d
commit 45ea3d5664
11 changed files with 457 additions and 54 deletions

View File

@@ -159,9 +159,9 @@ static long special(DBADDR *paddr, int after)
#define indexof(field) calcRecord##field
static long get_linkNumber(int fieldIndex) {
if (fieldIndex >= indexof(A) && fieldIndex <= indexof(L))
if (fieldIndex >= indexof(A) && fieldIndex < indexof(A) + CALCPERFORM_NARGS)
return fieldIndex - indexof(A);
if (fieldIndex >= indexof(LA) && fieldIndex <= indexof(LL))
if (fieldIndex >= indexof(LA) && fieldIndex < indexof(LA) + CALCPERFORM_NARGS)
return fieldIndex - indexof(LA);
return -1;
}

View File

@@ -34,8 +34,8 @@ These fields are described in L<Scan Fields|dbCommonRecord/Scan Fields>.
=head3 Read Parameters
The read parameters for the Calc record consist of 12 input links INPA,
INPB, ... INPL. The fields can be database links, channel access links, or
The read parameters for the Calc record consist of 21 input links INPA -
INPU. The fields can be database links, channel access links, or
constants. If they are links, they must specify another record's field or a
channel access link. If they are constants, they will be initialized with
the value they are configured with and can be changed via C<dbPuts>. They
@@ -45,7 +45,7 @@ See L<Address
Specification|https://docs.epics-controls.org/en/latest/guides/EPICS_Process_Database_Concepts.html#address-specification>
for information on how to specify database links.
=fields INPA, INPB, INPC, INPD, INPE, INPF, INPG, INPH, INPI, INPJ, INPK, INPL
=fields INPA - INPU
=head3 Expression
@@ -113,7 +113,7 @@ radians to degrees
The expression uses the values retrieved from the INPx links as operands,
though constants can be used as operands too. These values retrieved from
the input links are stored in the A-L fields. The values to be used in the
the input links are stored in the A-U fields. The values to be used in the
expression are simply referenced by the field letter. For instance, the
value obtained from INPA link is stored in the field A, and the value
obtained from INPB is stored in field B. The field names can be included in
@@ -121,7 +121,7 @@ the expression which will operate on their respective values, as in A+B.
Also, the RNDM nullary function can be included as an operand in the
expression in order to generate a random number between 0 and 1.
=fields A, B, C, D, E, F, G, H, I, J, K, L
=fields A - L
The keyword VAL returns the current contents of the VAL field (which can be
written to by a CA put, so it might I<not> be the result from the last time
@@ -492,12 +492,12 @@ modifiable at run-time. They are used to process the record.
The LALM field is used to implement the hysteresis factor for the alarm
limits.
The LA-LL fields are used to decide when to trigger monitors for the
The LA-LU fields are used to decide when to trigger monitors for the
corresponding fields. For instance, if LA does not equal the value A,
monitors for A are triggered. The MLST and ALST fields are used in the same
manner for the VAL field.
=fields LALM, ALST, MLST, LA, LB, LC, LD, LE, LF, LG, LH, LI, LJ, LK, LL
=fields LALM, ALST, MLST, LA - LU
=cut
@@ -575,6 +575,60 @@ manner for the VAL field.
promptgroup("42 - Input G-L")
interest(1)
}
field(INPM,DBF_INLINK) {
prompt("Input M")
special(SPC_MOD)
promptgroup("43 - Input M-R")
interest(1)
}
field(INPN,DBF_INLINK) {
prompt("Input N")
special(SPC_MOD)
promptgroup("43 - Input M-R")
interest(1)
}
field(INPO,DBF_INLINK) {
prompt("Input O")
special(SPC_MOD)
promptgroup("43 - Input M-R")
interest(1)
}
field(INPP,DBF_INLINK) {
prompt("Input P")
special(SPC_MOD)
promptgroup("43 - Input M-R")
interest(1)
}
field(INPQ,DBF_INLINK) {
prompt("Input Q")
special(SPC_MOD)
promptgroup("43 - Input M-R")
interest(1)
}
field(INPR,DBF_INLINK) {
prompt("Input R")
special(SPC_MOD)
promptgroup("43 - Input M-R")
interest(1)
}
field(INPS,DBF_INLINK) {
prompt("Input S")
special(SPC_MOD)
promptgroup("44 - Input S-U")
interest(1)
}
field(INPT,DBF_INLINK) {
prompt("Input T")
special(SPC_MOD)
promptgroup("44 - Input S-U")
interest(1)
}
field(INPU,DBF_INLINK) {
prompt("Input U")
special(SPC_MOD)
promptgroup("44 - Input S-U")
interest(1)
}
field(EGU,DBF_STRING) {
prompt("Engineering Units")
promptgroup("80 - Display")
@@ -733,6 +787,42 @@ manner for the VAL field.
prompt("Value of Input L")
pp(TRUE)
}
field(M,DBF_DOUBLE) {
prompt("Value of Input M")
pp(TRUE)
}
field(N,DBF_DOUBLE) {
prompt("Value of Input N")
pp(TRUE)
}
field(O,DBF_DOUBLE) {
prompt("Value of Input O")
pp(TRUE)
}
field(P,DBF_DOUBLE) {
prompt("Value of Input P")
pp(TRUE)
}
field(Q,DBF_DOUBLE) {
prompt("Value of Input Q")
pp(TRUE)
}
field(R,DBF_DOUBLE) {
prompt("Value of Input R")
pp(TRUE)
}
field(S,DBF_DOUBLE) {
prompt("Value of Input S")
pp(TRUE)
}
field(T,DBF_DOUBLE) {
prompt("Value of Input T")
pp(TRUE)
}
field(U,DBF_DOUBLE) {
prompt("Value of Input U")
pp(TRUE)
}
field(LA,DBF_DOUBLE) {
prompt("Prev Value of A")
special(SPC_NOMOD)
@@ -793,6 +883,51 @@ manner for the VAL field.
special(SPC_NOMOD)
interest(3)
}
field(LM,DBF_DOUBLE) {
prompt("Prev Value of M")
special(SPC_NOMOD)
interest(3)
}
field(LN,DBF_DOUBLE) {
prompt("Prev Value of N")
special(SPC_NOMOD)
interest(3)
}
field(LO,DBF_DOUBLE) {
prompt("Prev Value of O")
special(SPC_NOMOD)
interest(3)
}
field(LP,DBF_DOUBLE) {
prompt("Prev Value of P")
special(SPC_NOMOD)
interest(3)
}
field(LQ,DBF_DOUBLE) {
prompt("Prev Value of Q")
special(SPC_NOMOD)
interest(3)
}
field(LR,DBF_DOUBLE) {
prompt("Prev Value of R")
special(SPC_NOMOD)
interest(3)
}
field(LS,DBF_DOUBLE) {
prompt("Prev Value of S")
special(SPC_NOMOD)
interest(3)
}
field(LT,DBF_DOUBLE) {
prompt("Prev Value of T")
special(SPC_NOMOD)
interest(3)
}
field(LU,DBF_DOUBLE) {
prompt("Prev Value of U")
special(SPC_NOMOD)
interest(3)
}
field(LALM,DBF_DOUBLE) {
prompt("Last Value Alarmed")
special(SPC_NOMOD)
@@ -911,7 +1046,7 @@ Archive and values change monitors are invoked if ADEL and MDEL conditions
are met.
=item *
Monitors for A-L are checked whenever other monitors are invoked.
Monitors for A-U are checked whenever other monitors are invoked.
=item *
NSEV and NSTA are reset to 0.

View File

@@ -355,6 +355,15 @@ static long special(DBADDR *paddr, int after)
case(calcoutRecordINPJ):
case(calcoutRecordINPK):
case(calcoutRecordINPL):
case(calcoutRecordINPM):
case(calcoutRecordINPN):
case(calcoutRecordINPO):
case(calcoutRecordINPP):
case(calcoutRecordINPQ):
case(calcoutRecordINPR):
case(calcoutRecordINPS):
case(calcoutRecordINPT):
case(calcoutRecordINPU):
case(calcoutRecordOUT):
lnkIndex = fieldIndex - calcoutRecordINPA;
plink = &prec->inpa + lnkIndex;
@@ -406,9 +415,9 @@ static long special(DBADDR *paddr, int after)
#define indexof(field) calcoutRecord##field
static long get_linkNumber(int fieldIndex) {
if (fieldIndex >= indexof(A) && fieldIndex <= indexof(L))
if (fieldIndex >= indexof(A) && fieldIndex < indexof(A) + CALCPERFORM_NARGS)
return fieldIndex - indexof(A);
if (fieldIndex >= indexof(LA) && fieldIndex <= indexof(LL))
if (fieldIndex >= indexof(LA) && fieldIndex < indexof(LA) + CALCPERFORM_NARGS)
return fieldIndex - indexof(LA);
return -1;
}

View File

@@ -57,18 +57,18 @@ These fields are listed in L<Scan Fields|dbCommonRecord/Scan Fields>.
=head3 Read Parameters
The read parameters for the Calcout record consists of 12 input links INPA,
INPB, ... INPL. The fields can be database links, channel access links, or
The read parameters for the Calcout record consists of 21 input links INPA -
INPU. The fields can be database links, channel access links, or
constants. If they are links, they must specify another record's field. If
they are constants, they will be initialized with the value they are
configured with and can be changed via C<dbPuts>. These fields cannot be
hardware addresses. In addition, the Calcout record contains the INAV,
INBV, ... INLV fields which indicate the status of the link fields, for
hardware addresses. In addition, the Calcout record contains the INAV -
INUV fields which indicate the status of the link fields, for
example, whether or not the specified PV was found and a link to it
established. See L<Operator Display Parameters> for an explanation of these
fields.
=fields INPA, INPB, INPC, INPD, INPE, INPF, INPG, INPH, INPI, INPJ, INPK, INPL
=fields INPA - INPU
=head3 Expression
@@ -139,14 +139,14 @@ angle from radians to degrees
The expression can use the values retrieved from the INPx links as
operands, though constants can be used as operands too. These values
retrieved from the input links are stored in the A-L fields. The values to
retrieved from the input links are stored in the A-U fields. The values to
be used in the expression are simple references by the field letter. For
instance, the value obtained from the INPA link is stored in field A, and
the values obtained from the INPB link is stored in the field B. The names
can be included in the expression will operate on their respective values,
as in A+B.
=fields A, B, C, D, E, F, G, H, I, J, K, L
=fields A - U
The keyword VAL returns the current contents of the expression's result
field, i.e. the VAL field for the CALC expression and the OVAL field for
@@ -543,8 +543,8 @@ LOW, and LOLO fields. PREC controls the precision of the VAL field.
=head4 Menu calcoutINAV
The INAV-INLV fields indicate the status of the link to the PVs specified
in the INPA-INPL fields respectively. These fields can have four possible
The INAV-INUV fields indicate the status of the link to the PVs specified
in the INPA-INPU fields respectively. These fields can have four possible
values:
=menu calcoutINAV
@@ -568,7 +568,7 @@ C<Constant> -- the corresponding link field is a constant.
=back
The OUTV field indicates the status of the OUT link. If has the same
possible values as the INAV-INLV fields.
possible values as the INAV-INUV fields.
The CLCV and OLCV fields indicate the validity of the expression in the
CALC and OCAL fields respectively. If the expression in invalid, the field
@@ -579,7 +579,7 @@ The DLYA field is set to one during the delay specified in ODLY.
See L<Fields Common to All Record Types|dbCommonRecord/Operator Display
Parameters> for more on the record name (NAME) and description (DESC) fields.
=fields EGU, PREC, HOPR, LOPR, INAV, INBV, INCV, INDV, INEV, INFV, INGV, INHV, INIV, INJV, INKV, INLV, OUTV, CLCV, OCLV, DLYA, NAME, DESC
=fields EGU, PREC, HOPR, LOPR, INAV - INUV, OUTV, CLCV, OCLV, DLYA, NAME, DESC
=head3 Alarm Parameters
@@ -623,12 +623,12 @@ modifiable at run-time. They are used to process the record.
The LALM field is used to implement the hysteresis factor for the alarm
limits.
The LA-LL fields are used to decide when to trigger monitors for the
The LA-LU fields are used to decide when to trigger monitors for the
corresponding fields. For instance, if LA does not equal the value for A,
monitors for A are triggered. The MLST and ALST fields are used in the same
manner for the VAL field.
=fields LALM, ALST, MLST, LA, LB, LC, LD, LE, LF, LG, LH, LI, LJ, LK, LL
=fields LALM, ALST, MLST, LA - LU
=cut
@@ -739,6 +739,60 @@ manner for the VAL field.
promptgroup("42 - Input G-L")
interest(1)
}
field(INPM,DBF_INLINK) {
prompt("Input M")
special(SPC_MOD)
promptgroup("43 - Input M-R")
interest(1)
}
field(INPN,DBF_INLINK) {
prompt("Input N")
special(SPC_MOD)
promptgroup("43 - Input M-R")
interest(1)
}
field(INPO,DBF_INLINK) {
prompt("Input O")
special(SPC_MOD)
promptgroup("43 - Input M-R")
interest(1)
}
field(INPP,DBF_INLINK) {
prompt("Input P")
special(SPC_MOD)
promptgroup("43 - Input M-R")
interest(1)
}
field(INPQ,DBF_INLINK) {
prompt("Input Q")
special(SPC_MOD)
promptgroup("43 - Input M-R")
interest(1)
}
field(INPR,DBF_INLINK) {
prompt("Input R")
special(SPC_MOD)
promptgroup("43 - Input M-R")
interest(1)
}
field(INPS,DBF_INLINK) {
prompt("Input S")
special(SPC_MOD)
promptgroup("44 - Input S-U")
interest(1)
}
field(INPT,DBF_INLINK) {
prompt("Input T")
special(SPC_MOD)
promptgroup("44 - Input S-U")
interest(1)
}
field(INPU,DBF_INLINK) {
prompt("Input U")
special(SPC_MOD)
promptgroup("44 - Input S-U")
interest(1)
}
field(OUT,DBF_OUTLINK) {
prompt("Output Specification")
special(SPC_MOD)
@@ -829,6 +883,69 @@ manner for the VAL field.
menu(calcoutINAV)
initial("1")
}
field(INMV,DBF_MENU) {
prompt("INPM PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INNV,DBF_MENU) {
prompt("INPN PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INOV,DBF_MENU) {
prompt("INPO PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INPV,DBF_MENU) {
prompt("INPP PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INQV,DBF_MENU) {
prompt("INPQ PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INRV,DBF_MENU) {
prompt("INPR PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INSV,DBF_MENU) {
prompt("INPS PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INTV,DBF_MENU) {
prompt("INPT PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(INUV,DBF_MENU) {
prompt("INPU PV Status")
special(SPC_NOMOD)
interest(1)
menu(calcoutINAV)
initial("1")
}
field(OUTV,DBF_MENU) {
prompt("OUT PV Status")
special(SPC_NOMOD)
@@ -1043,6 +1160,42 @@ manner for the VAL field.
prompt("Value of Input L")
pp(TRUE)
}
field(M,DBF_DOUBLE) {
prompt("Value of Input M")
pp(TRUE)
}
field(N,DBF_DOUBLE) {
prompt("Value of Input N")
pp(TRUE)
}
field(O,DBF_DOUBLE) {
prompt("Value of Input O")
pp(TRUE)
}
field(P,DBF_DOUBLE) {
prompt("Value of Input P")
pp(TRUE)
}
field(Q,DBF_DOUBLE) {
prompt("Value of Input Q")
pp(TRUE)
}
field(R,DBF_DOUBLE) {
prompt("Value of Input R")
pp(TRUE)
}
field(S,DBF_DOUBLE) {
prompt("Value of Input S")
pp(TRUE)
}
field(T,DBF_DOUBLE) {
prompt("Value of Input T")
pp(TRUE)
}
field(U,DBF_DOUBLE) {
prompt("Value of Input U")
pp(TRUE)
}
field(OVAL,DBF_DOUBLE) {
prompt("Output Value")
asl(ASL0)
@@ -1107,6 +1260,51 @@ manner for the VAL field.
special(SPC_NOMOD)
interest(3)
}
field(LM,DBF_DOUBLE) {
prompt("Prev Value of M")
special(SPC_NOMOD)
interest(3)
}
field(LN,DBF_DOUBLE) {
prompt("Prev Value of N")
special(SPC_NOMOD)
interest(3)
}
field(LO,DBF_DOUBLE) {
prompt("Prev Value of O")
special(SPC_NOMOD)
interest(3)
}
field(LP,DBF_DOUBLE) {
prompt("Prev Value of P")
special(SPC_NOMOD)
interest(3)
}
field(LQ,DBF_DOUBLE) {
prompt("Prev Value of Q")
special(SPC_NOMOD)
interest(3)
}
field(LR,DBF_DOUBLE) {
prompt("Prev Value of R")
special(SPC_NOMOD)
interest(3)
}
field(LS,DBF_DOUBLE) {
prompt("Prev Value of S")
special(SPC_NOMOD)
interest(3)
}
field(LT,DBF_DOUBLE) {
prompt("Prev Value of T")
special(SPC_NOMOD)
interest(3)
}
field(LU,DBF_DOUBLE) {
prompt("Prev Value of U")
special(SPC_NOMOD)
interest(3)
}
field(POVL,DBF_DOUBLE) {
prompt("Prev Value of OVAL")
asl(ASL0)
@@ -1241,7 +1439,7 @@ Archive and value change monitors are invoked if ADEL and MDEL conditions
are met.
=item *
Monitors for A-L are checked whenever other monitors are invoked.
Monitors for A-U are checked whenever other monitors are invoked.
=item *
NSEV and NSTA are reset to 0