Merge branch '3.15' into 7.0

* 3.15: (28 commits)
  update RELEASE_NOTES
  add option EPICS_NO_CALLBACK
  replace CALLBACK -> epicsCallback
  Update dbTest.c
  Remove links to wiki-ext
  Add POD annotations from Wiki to subArrayRecord and menuAlarmStat
  Rename subArrayRecord.dbd and menuAlarmStat.dbd to .pod
  Add POD annotations to longoutRecord from Wiki
  Rename longoutRecord.dbd longoutRecord.dbd.pod
  Add POD annotations to longinRecord from Wiki
  Rename longinRecord.dbd longinRecord.dbd.pod
  Add POD annotations to subRecord from Wiki
  Rename subRecord.dbd subRecord.dbd.pod
  Add POD annotations to selRecord from Wiki
  Rename selRecord.dbd selRecord.dbd.pod
  Add POD annotations to seqRecord from Wiki
  Rename seqRecord.dbd seqRecord.dbd.pod
  Fix menu declaration test too
  Add redefinition guard to menu-generated typedefs
  Updates to existing .dbd.pod texts, add event and fanout from wiki
  ...

# Conflicts:
#	documentation/README.1st
#	documentation/README.html
#	modules/database/src/ioc/db/callback.h
#	modules/database/src/ioc/db/dbNotify.c
#	modules/database/src/ioc/db/menuAlarmStat.dbd
#	modules/database/src/ioc/db/menuFtype.dbd
#	modules/database/src/std/rec/compressRecord.dbd.pod
#	modules/database/src/std/rec/eventRecord.dbd
#	modules/database/src/std/rec/fanoutRecord.dbd
#	modules/database/src/std/rec/longinRecord.dbd
#	modules/database/src/std/rec/longoutRecord.dbd
#	modules/database/src/std/rec/selRecord.dbd
#	modules/database/src/std/rec/seqRecord.dbd
#	modules/database/src/std/rec/subArrayRecord.dbd
#	modules/database/src/std/rec/subRecord.dbd
#	modules/libcom/src/iocsh/menuAlarmStat.dbd.pod
#	modules/libcom/src/iocsh/menuFtype.dbd.pod
#	src/ioc/db/menuAlarmStat.dbd
#	src/ioc/db/menuFtype.dbd

Manually fix some move+rename
Make additional CALLBACK -> epicsCallback
preserve INT64 in menuFtype
preserve OLDSIM et al
This commit is contained in:
Michael Davidsaver
2019-09-09 18:13:37 -07:00
88 changed files with 5812 additions and 2702 deletions

View File

@@ -34,7 +34,7 @@
/* The following is provided for access security*/
/*It allows a CA client to force access security initialization*/
static void myCallback(CALLBACK *pcallback)
static void myCallback(epicsCallback *pcallback)
{
ASDBCALLBACK *pasdbcallback = (ASDBCALLBACK *)pcallback;
subRecord *precord;

View File

@@ -36,7 +36,7 @@
typedef struct devPvt {
processNotify pn;
CALLBACK callback;
epicsCallback callback;
long options;
int status;
int smooth;

View File

@@ -35,7 +35,7 @@
typedef struct devPvt {
processNotify pn;
CALLBACK callback;
epicsCallback callback;
long options;
int status;
struct {

View File

@@ -35,7 +35,7 @@
typedef struct devPvt {
processNotify pn;
CALLBACK callback;
epicsCallback callback;
long options;
int status;
struct {

View File

@@ -35,7 +35,7 @@
typedef struct devPvt {
processNotify pn;
CALLBACK callback;
epicsCallback callback;
long options;
int status;
struct {

View File

@@ -35,7 +35,7 @@
typedef struct devPvt {
processNotify pn;
CALLBACK callback;
epicsCallback callback;
long options;
int status;
struct {

View File

@@ -37,7 +37,7 @@
typedef struct devPvt {
DBADDR dbaddr;
processNotify pn;
CALLBACK callback;
epicsCallback callback;
long options;
int status;
struct {

View File

@@ -55,3 +55,7 @@ stdRecords_DBD = $(patsubst %,%.dbd,$(stdRecords))
dbRecStd_SRCS += $(patsubst %,%.c,$(stdRecords))
HTMLS += $(patsubst %.dbd.pod,%.html,$(notdir $(wildcard ../rec/*Record.dbd.pod)))
vpath %.png $(SRC_DIRS)
HTMLS += image/compress-1.png
HTMLS += image/compress-2.png

View File

@@ -356,10 +356,10 @@ static long readValue(aaiRecord *prec)
recGblSetSevr(prec, SIMM_ALARM, prec->sims);
if (prec->sdly >= 0) {
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) { /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(CALLBACK));
pvt = calloc(1, sizeof(epicsCallback));
prec->simpvt = pvt;
}
if (pvt)

View File

@@ -122,7 +122,7 @@ recordtype(aai) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
field(MPST,DBF_MENU) {
prompt("Post Value Monitors")

View File

@@ -367,9 +367,9 @@ static long writeValue(aaoRecord *prec)
status = pdset->write_aao(prec);
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -122,7 +122,7 @@ recordtype(aao) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
field(MPST,DBF_MENU) {
prompt("Post Value Monitors")

View File

@@ -508,9 +508,9 @@ static long readValue(aiRecord *prec)
}
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -516,7 +516,7 @@ simulation mode.
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
}

View File

@@ -574,9 +574,9 @@ static long writeValue(aoRecord *prec)
status = dbPutLink(&prec->siol, DBR_DOUBLE, &prec->oval, 1);
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -70,7 +70,7 @@ output value PVAL is added to it.
=head4 Drive Limits
The output value is now clipped to the range DRVL to DRVH inclusive, provided
that DRVH > DRVL.
that DRVH E<gt> DRVL.
The result is copied into both the VAL and PVAL fields.
=head4 Limit Rate of Change
@@ -164,9 +164,7 @@ OUT field must specify the address of the I/O card. In addition, the
DTYP field must contain the name of the device support module. Be aware
that the address format differs according to the I/O bus used. See
Address Specification for information on the format of hardware
addresses. The user can see a list of the device support modules
currently supported at the user's local site by using the dbst utility
in R3.13.
addresses.
For soft records the output link can be a database link, a channel
access link, or a constant value. If the link is a constant, no output
@@ -573,7 +571,7 @@ information on these fields.
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
field(IVOA,DBF_MENU) {
prompt("INVALID output action")
@@ -620,7 +618,7 @@ terminated.
For compatibility with old device supports that don't know EOFF, if
both EOFF and ESLO have their default value, EOFF is set to EGUL.
If device support includes init_record, it is called.
If device support includes C<init_record()>, it is called.
INIT is set TRUE. This causes PBRK, LBRK, and smoothing to be
re-initialized. If "backwards" linear conversion is requested, then VAL
@@ -647,10 +645,6 @@ called.
INIT is set TRUE. This causes PBRK, LBRK, and smoothing to be
re-initialized.
=item get_value
Fills in the values of struct valueDes so that they refer to VAL.
=item get_alarm_double
Sets the following values:
@@ -930,7 +924,7 @@ OUT link type must be either a CONSTANT, DB_LINK, or CA_LINK.
This module writes the current value of OVAL.
If the OUT link type is PV_LINK, then dbCaAddInlink is called by
init_record. init_record always returns a value of 2, which means that
C<init_record()>. C<init_record()> always returns a value of 2, which means that
no conversion will ever be attempted.
write_ao calls recGblPutLinkValue to write the current value of VAL.

View File

@@ -304,9 +304,9 @@ static long readValue(biRecord *prec)
}
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -69,9 +69,7 @@ If the binary input record gets its value from hardware, the address of the
card must be entered in the INP field, and the name of the device support
module must be entered in the DTYP field. See L<Address Specification> for
information on the format of the hardware address. Be aware that the format
differs between types of cards. You can see a list of device support
modules currently supported at the user's local site by using C<dbst>
utility (R3.13).
differs between types of cards.
For records that specify C<Soft Channel> or C<Raw Soft Channel> device
support routines, the INP field can be a channel or a database link, or a
@@ -94,18 +92,18 @@ the device support module reads a value directly into VAL or the
C<Soft Channel> device support is used. The value can also be fetched as one of
the strings specified in the ZNAM or ONAM fields. The ZNAM field has a
string that corresponds to the 0 state, so when the value is fetched as
this string, C<put_enum_str> will return a 0. The ONAM field hold the
this string, C<put_enum_str()> will return a 0. The ONAM field hold the
string that corresponds to the 1 state, so when the value is fetched as
this string, C<put_enum_str> returns a 1.
this string, C<put_enum_str()> returns a 1.
=fields ZNAM, ONAM
=head3 Operator Display Parameters
These parameters are used to present meaningful data to the operator. The
C<get_enum_str> record support routine can retrieve the state string
corresponding to the VAL's state. If the value is 1, C<get_enum_str> will
return the string in the ONAM field; and if 0, C<get_enum_str> will return
C<get_enum_str()> record support routine can retrieve the state string
corresponding to the VAL's state. If the value is 1, C<get_enum_str()> will
return the string in the ONAM field; and if 0, C<get_enum_str()> will return
the ZNAM string.
See L<Fields Common to All Record Types> for more on the record name (NAME)
@@ -149,7 +147,7 @@ The LALM fields holds the value of the last occurence of the change of
state alarm. It is used to implement the change of state alarm, and thus
only has meaning if COSV is MAJOR or MINOR.
The MSLT field is used by the C<process> record support routine to
The MSLT field is used by the C<process()> record support routine to
determine if archive and value change monitors are invoked. They are if MSLT
is not equal to VAL.
@@ -286,7 +284,7 @@ these fields.
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
=head2 Record Support
@@ -303,16 +301,12 @@ This routine next checks to see that device support is available and a
device support routine is defined. If neither exist, an error is issued and
processing is terminated.
If device support includes C<init_record>, it is called.
If device support includes C<init_record()>, it is called.
=head2 C<process>
See next section.
=head2 C<get_value>
Fills in the values of struct valueDes so that they refer to VAL.
=head2 C<get_enum_str>
Retrieves ASCII string corresponding to VAL.
@@ -338,7 +332,7 @@ the PACT field still set to TRUE. This ensures that processes will no
longer be called for this record. Thus error storms will not occur.
=item 2.
C<readValue> is called. See L<Input Records> for details.
C<readValue()> is called. See L<Input Records> for details.
=item 3.
If PACT has been changed to TRUE, the device support read routine has
@@ -359,7 +353,7 @@ status = read_bi
PACT = TRUE
=item *
TIME = tslocaltime
C<recGblGetTimeStamp()> is called.
=item *
if status is 0, then set VAL=(0,1) if RVAL is (0, not 0) and UDF = False.
@@ -410,7 +404,7 @@ Scan forward link if necessary, set PACT FALSE, and return.
Each binary input record must have an associated set of device support
routines. The primary resposibility of the device support routines is to
obtain a new raw input value whenever C<read_bi> is called. The device
obtain a new raw input value whenever C<read_bi()> is called. The device
support routines are primarily interested in the following fields:
=fields PACT, DPVT, UDF, NSEV, NSTA, VAL, INP, RVAL, MASK
@@ -419,22 +413,32 @@ support routines are primarily interested in the following fields:
Device support consists of the following routines:
=head2 C<report(FILE fp, paddr)>
=head4 long report(int level)
Not currently used.
This optional routine is called by the IOC command C<dbior> and is passed the
report level that was requested by the user.
It should print a report on the state of the device support to stdout.
The C<level> parameter may be used to output increasingly more detailed
information at higher levels, or to select different types of information with
different levels.
Level zero should print no more than a small summary.
=head2 C<init()>
=head4 long init(int after)
This routine is called once during IOC initialization.
This optional routine is called twice at IOC initialization time.
The first call happens before any of the C<init_record()> calls are made, with
the integer parameter C<after> set to 0.
The second call happens after all of the C<init_record()> calls have been made,
with C<after> set to 1.
=head2 C<init_record(precord)>
This routine is optional. If provided, it is called by the record support
C<init_record> routine.
C<init_record()> routine.
=head2 C<get_ioint_info(int cmd, struct dbCommon *precord, IOSCANPVT *ppvt)>
This routine is called by the C<ioEventScan> system each time the record is
This routine is called by the ioEventScan system each time the record is
added or deleted from an I/O event scan list. C<cmd> has the value (0,1) if
the record is being (added to, deleted from) and I/O event list. It must be
provided for any device type that can use the ioEvent scanner.
@@ -466,25 +470,25 @@ link type must be either CONSTANT, DB_LINK, or CA_LINK.
=head3 Soft Channel
C<read_bi> always returns a value of 2, which means that no conversion is
C<read_bi()> always returns a value of 2, which means that no conversion is
performed.
If the INP link type is CONSTANT, then the constant value is stored in VAL
by C<init_record>, and the UDF is set to FALSE. VAL can be changed via
C<dbPut> requests. If the INP link type is PV_LINK, the C<dbCaAddInlink> is
called by C<init_record>.
by C<init_record()>, and the UDF is set to FALSE. VAL can be changed via
C<dbPut()> requests. If the INP link type is PV_LINK, the C<dbCaAddInlink()> is
called by C<init_record()>.
C<read_bi> calls C<recGbleGetLinkValue> to read the current value of VAL.
C<read_bi()> calls C<dbGetLinkValue> to read the current value of VAL.
See L<Soft Input> for details.
If the return status of C<recGblGetLinkValue> is zero, then C<read_bi> sets
UDF to FALSE. The status of C<recGblGetLinkValue> is returned.
If the return status of C<dbGetLinkValue()> is zero, then C<read_bi()> sets
UDF to FALSE. The status of C<dbGetLinkValue()> is returned.
=head3 Raw Soft Channel
This module is like the previous except that values are read into RVAL.
C<read_bi> returns a value of 0. Thus the record processing routine will
C<read_bi()> returns a value of 0. Thus the record processing routine will
force VAL to be 0 or 1.
=cut

View File

@@ -98,7 +98,7 @@ struct bodset { /* binary output dset */
/* control block for callback*/
typedef struct myCallback {
CALLBACK callback;
epicsCallback callback;
struct dbCommon *precord;
}myCallback;
@@ -106,7 +106,7 @@ static void checkAlarms(boRecord *);
static void monitor(boRecord *);
static long writeValue(boRecord *);
static void myCallbackFunc(CALLBACK *arg)
static void myCallbackFunc(epicsCallback *arg)
{
myCallback *pcallback;
boRecord *prec;
@@ -439,9 +439,9 @@ static long writeValue(boRecord *prec)
status = dbPutLink(&prec->siol, DBR_USHORT, &prec->val, 1);
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -130,8 +130,7 @@ It must specify the address of an I/O card if the record sends its output
to hardware, and the DTYP field must contain the corresponding device
support module. Be aware that the address format differs according to the
I/O bus used. See L<Address Specification> for information on the format of
hardware addresses. You can see a list of device support modules currently
supported at the user's local site by using the C<dbst> utility in R3.13.
hardware addresses.
Otherwise, if the record is configured to use the soft device support
modules, then it can be either a database link, a channel access link, or a
@@ -143,9 +142,9 @@ this chapter for more on output to other records.
=head3 Operator Display Parameters
These parameters are used to present meaningful data to the operator, The
C<get_enum_str> record support routine can retrieve the state string
corresponding to the VAL's state. So, if the value is 1, C<get_enum_str>
will return the string in the ONAM field: and if 0, C<get_enum_str> will
C<get_enum_str()> record support routine can retrieve the state string
corresponding to the VAL's state. So, if the value is 1, C<get_enum_str()>
will return the string in the ONAM field: and if 0, C<get_enum_str()> will
return the ZNAM string.
See L<Fields Common to All Record Types> for more on the record name (NAME)
@@ -194,7 +193,7 @@ The LALM field holds the value of the last occurrence of the change of
state alarm. It is used to implement the change of state alarm, and thus
only has meaning if COSV is MINOR or MAJOR.
The MLST is used by the C<process> record support routine to determine if
The MLST is used by the C<process()> record support routine to determine if
archive and value change monitors are invoked. They are if MLST is not
equal to VAL.
@@ -366,7 +365,7 @@ information on these fields.
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
field(IVOA,DBF_MENU) {
prompt("INVALID outpt action")
@@ -400,17 +399,13 @@ exist, and error message is issued and processing is terminated.
If DOL is a constant, then VAL is initialized to 1 if its value is nonzero
or initialzed to 0 if DOL is zero, and UDF is set to FALSE.
If device support includes C<init_record>, it is called. VAL is set using
If device support includes C<init_record()>, it is called. VAL is set using
RVAL, and UDF is set to FALSE.
=head2 C<process>
See next section.
=head2 C<get_value>
Fills in the values of struct valueDes so that they refer to VAL.
=head2 C<get_enum_str>
Retrieves ASCII string corresponding to VAL.
@@ -443,7 +438,7 @@ If PACT is FALSE
=over
=item *
If DOL is DB_LINK and OMSL is CLOSED_LOOP
If DOL holds a link and OMSL is C<closed_loop>
=over
@@ -527,27 +522,37 @@ Scan forward link if necessary, set PACT FALSE, and return
Each binary output record must have an associated set of device support
routines. The primary responsibility of the device support routines is to
write a new value whenever C<write_bo> is called. The device support routines
write a new value whenever C<write_bo()> is called. The device support routines
are primarily interested in the following fields:
=fields PACT, DPVT, NSEV, NSTA, VAL, OUT, RVAL, MASK, RBV
=head3 Decive Support Routines
=head3 Device Support Routines
Device support consists of the following routines:
=head2 C<report(FILE fp, paddr)>
=head4 long report(int level)
Not currently used.
This optional routine is called by the IOC command C<dbior> and is passed the
report level that was requested by the user.
It should print a report on the state of the device support to stdout.
The C<level> parameter may be used to output increasingly more detailed
information at higher levels, or to select different types of information with
different levels.
Level zero should print no more than a small summary.
=head2 C<init()>
=head4 long init(int after)
This routine is called once during IOC initialization.
This optional routine is called twice at IOC initialization time.
The first call happens before any of the C<init_record()> calls are made, with
the integer parameter C<after> set to 0.
The second call happens after all of the C<init_record()> calls have been made,
with C<after> set to 1.
=head2 C<init_record(precord)>
This routine is optional. If provided, it is called by record support
C<init_record> routine. It should determine MASK if it is needed.
C<init_record()> routine. It should determine MASK if it is needed.
=over
@@ -593,10 +598,10 @@ link type must be either CONSTANT, DB_LINK, or CA_LINK.
This module writes the current value of VAL.
If the OUT link type is PV_LINK, then C<dbCaAddInlink> is called by
C<init_record>. C<init_record> always returns a value of 2, which means
that no conversion will ever be attempted. C<write_bo> calls
C<recGblPutLinkValue> to write the current value of VAL. See L<Soft Output>
If the OUT link type is PV_LINK, then C<dbCaAddInlink()> is called by
C<init_record()>. C<init_record()> always returns a value of 2, which means
that no conversion will ever be attempted. C<write_bo()> calls
C<recGblPutLinkValue()> to write the current value of VAL. See L<Soft Output>
for details.
=head3 Raw Soft Channel

View File

@@ -261,22 +261,22 @@ ATAN: Arc tangent
=over 1
=item *
>= : Greater than or equal to
C<<< >= >>> : Greater than or equal to
=item *
> : Greater than
C<<< > >>> : Greater than
=item *
<= : Less than or equal to
C<<< <= >>> : Less than or equal to
=item *
< : Less than
C<<< < >>> : Less than
=item *
# : Not equal to
C<<< # >>> : Not equal to
=item *
= : Equal to
C<<< = >>> : Equal to
=back
@@ -285,13 +285,13 @@ ATAN: Arc tangent
=over 1
=item *
&& : And
C<&&> : And
=item *
|| : Or
C<||> : Or
=item *
! : Not
C<!> : Not
=back
@@ -300,10 +300,10 @@ ATAN: Arc tangent
=over 1
=item *
| : Bitwise Or
C<|> : Bitwise Or
=item *
& : Bitwise And
C<&> : Bitwise And
=item *
OR : Bitwise Or
@@ -315,13 +315,13 @@ AND : Bitwise And
XOR : Bitwise Exclusive Or
=item *
~ : One's Complement
C<~> : One's Complement
=item *
<< : Left shift
C<<< << >>> : Left shift
=item *
>> : Right shift
C<<< >> >>> : Right shift
=back
@@ -330,7 +330,7 @@ XOR : Bitwise Exclusive Or
=over 1
=item *
:= : assigns a value (right hand side) to a variable (i.e. field)
C<:=> : assigns a value (right hand side) to a variable (i.e. field)
=back
@@ -360,35 +360,35 @@ C<A + B + 10>
=over 1
=item *
Result is A + B + 10
Result is C<A + B + 10>
=back
=head3 Relational
C<(A + B) < (C + D)>
C<<< (A + B) < (C + D) >>>
=over 1
=item *
Result is 1 if (A + B) < (C + D)
Result is 1 if C<<< (A + B) < (C + D) >>>
=item *
Result is 0 if (A + B) >= (C + D)
Result is 0 if C<<< (A + B) >= (C + D) >>>
=back
=head3 Question Mark
C<(A + B) < (C + D) ? E : F + L + 10>
C<<< (A + B) < (C + D) ? E : F + L + 10 >>>
=over 1
=item *
Result is E if (A + B) < (C + D)
Result is C<E> if C<<< (A + B) < (C + D) >>>
=item *
Result is F + L + 10 if (A + B) >= (C + D)
Result is C<F + L + 10> if C<<< (A + B) >= (C + D) >>>
=back
@@ -412,7 +412,7 @@ C<(A + B) < (C + D) ? E : VAL>
=head3 Logical
C<A&B>
C<A & B>
=over 1
@@ -851,10 +851,6 @@ See next section.
This is called if CALC is changed. C<special> calls postfix.
=head2 C<get_value>
Fills in the values of struct valueDes so that the refer to VAL.
=head2 C<get_units>
Retrieves EGU.

View File

@@ -117,8 +117,8 @@ typedef struct calcoutDSET {
#define CA_LINKS_NOT_OK 2
typedef struct rpvtStruct {
CALLBACK doOutCb;
CALLBACK checkLinkCb;
epicsCallback doOutCb;
epicsCallback checkLinkCb;
short cbScheduled;
short caLinkStat; /* NO_CA_LINKS, CA_LINKS_ALL_OK, CA_LINKS_NOT_OK */
} rpvtStruct;
@@ -128,7 +128,7 @@ static void monitor(calcoutRecord *prec);
static int fetch_values(calcoutRecord *prec);
static void execOutput(calcoutRecord *prec);
static void checkLinks(calcoutRecord *prec);
static void checkLinksCallback(CALLBACK *arg);
static void checkLinksCallback(epicsCallback *arg);
static long writeValue(calcoutRecord *prec);
int calcoutRecDebug;
@@ -702,7 +702,7 @@ static int fetch_values(calcoutRecord *prec)
return(status);
}
static void checkLinksCallback(CALLBACK *arg)
static void checkLinksCallback(epicsCallback *arg)
{
calcoutRecord *prec;
@@ -760,7 +760,7 @@ static void checkLinks(calcoutRecord *prec)
prpvt->caLinkStat = NO_CA_LINKS;
if (!prpvt->cbScheduled && caLinkNc) {
/* Schedule another CALLBACK */
/* Schedule another epicsCallback */
prpvt->cbScheduled = 1;
callbackRequestDelayed(&prpvt->checkLinkCb, .5);
}

View File

@@ -293,22 +293,22 @@ ATAN: Arc tangent
=over 1
=item *
>= : Greater than or equal to
C<<< >= >>> : Greater than or equal to
=item *
> : Greater than
C<<< > >>> : Greater than
=item *
<= : Less than or equal to
C<<< <= >>> : Less than or equal to
=item *
< : Less than
C<<< < >>> : Less than
=item *
# : Not equal to
C<<< # >>> : Not equal to
=item *
= : Equal to
C<<< = >>> : Equal to
=back
@@ -332,10 +332,10 @@ ATAN: Arc tangent
=over 1
=item *
| : Bitwise Or
C<|> : Bitwise Or
=item *
& : Bitwise And
C<&> : Bitwise And
=item *
OR : Bitwise Or
@@ -347,13 +347,13 @@ AND : Bitwise And
XOR : Bitwise Exclusive Or
=item *
~ : One's Complement
C<~> : One's Complement
=item *
<< : Left shift
C<<< << >>> : Left shift
=item *
>> : Right shift
C<<< >> >>> : Right shift
=back
@@ -362,11 +362,11 @@ XOR : Bitwise Exclusive Or
=over 1
=item *
:= : assigns a value (right hand side) to a variable (i.e. field)
C<:=> : assigns a value (right hand side) to a variable (i.e. field)
=back
=head3 Parentheses and Comma
=head3 Parantheses, Comma, and Semicolon
The open and close parentheses are supported. Nested parentheses are
supported.
@@ -374,6 +374,10 @@ supported.
The comma is supported when used to separate the arguments of a binary
function.
The semicolon is used to separate expressions. Although only one
traditional calculation expression is allowed, multiple assignment
expressions are allowed.
=head3 Conditional Expression
The C language's question mark operator is supported. The format is:
@@ -388,41 +392,59 @@ C<A + B + 10>
=over 1
=item *
Result is A + B + 10
Result is C<A + B + 10>
=back
=head3 Relational
C<(A + B) < (C + D)>
C<<< (A + B) < (C + D) >>>
=over 1
=item *
Result is 1 if (A + B) < (C + D)
Result is 1 if C<<< (A + B) < (C + D) >>>
=item *
Result is 0 if (A + B) >= (C + D)
Result is 0 if C<<< (A + B) >= (C + D) >>>
=back
=head3 Question Mark
C<(A + B) < (C + D) ? E : F + L + 10>
C<<< (A + B) < (C + D) ? E : F + L + 10 >>>
=over 1
=item *
Result is E if (A + B) < (C + D)
Result is C<E> if C<<< (A + B) < (C + D) >>>
=item *
Result is F + L + 10 if (A + B) >= (C + D)
Result is C<F + L + 10> if C<<< (A + B) >= (C + D) >>>
=back
Prior to Base 3.14.9 it was legal to omit the : and the second (else) part
of the conditional, like this:
C<(A + B)<(C + D) ? E>
=over 1
=item
Result is E if (A + B)<(C + D)
=item
Result is unchanged if (A + B)>=(C + D)
From 3.14.9 onwards, this expresion must be written as
C<(A + B) < (C + D) ? E : VAL>
=back
=head3 Logical
C<A&B>
C<A & B>
=over 1
@@ -447,6 +469,18 @@ Convert result to floating point
=back
=head3 Assignment
C<sin(a); a:=a+D2R>
=over 1
=item *
Causes the Calc record to output the successive values of a sine curve in
1 degree intervals.
=back
=head3 Output Parameters
These parameters specify and control the output capabilities of the Calcout
@@ -529,7 +563,7 @@ are also meant to represent the status of the record at run-time.
The EGU field contains a string of up to 16 characters which is supplied by
the user and which describes the values being operated upon. The string is
retrieved whenever the routine C<get_units> is called. The EGU string is
retrieved whenever the routine C<get_units()> is called. The EGU string is
solely for an operator's sake and does not have to be used.
The HOPR and LOPR fields on;y refer to the limits if the VAL, HIHI, HIGH,
@@ -1146,10 +1180,6 @@ See next section.
This is called id CALC or OCAL is changed. C<special> calls postfix.
=head2 C<get_value>
Fills in the values of struct valueDes so that they refer to VAL.
=head2 C<get_units>
Retrieves EGU.

View File

@@ -7,7 +7,7 @@
# in file LICENSE that is included with this distribution.
#*************************************************************************
=title Compress Record (compress)
=title Compression Record (compress)
The data compression record is used to collect and compress data from arrays.
When the INP field references a data array field, it immediately compresses the
@@ -62,7 +62,359 @@ menu(bufferingALG) {
}
recordtype(compress) {
=fields VAL
=head2 Contents
=over
=item * L<Parameter Fields>
=over
=item * L<Scanning Parameters>
=item * L<Algorithms and Related Parameters>
=item * L<Operator Display Parameters>
=item * L<Run-time Parameters>
=back
=item * L<Record Support>
=over
=item * L<Record Support Routines>
=item * L<Record Processing>
=back
=back
=begin html
<br>
<hr>
<br>
=end html
=head2 Parameter Fields
=head3 Scanning Parameters
The compression record has the standard fields for specifying under what
circumstances the record will be processed. These fields are listed in
L<Scan Fields>. In addition, L<Scanning Specification>
explains how these fields are used. Since the compression record supports no
direct interfaces to hardware, its SCAN field cannot specify C<<< I/O Intr >>>.
=head3 Algorithms and Related Parameters
The user specifies the algorithm to be used in the ALG field. There are six possible
algorithms which can be specified as follows:
=head4 Menu compressALG
=menu compressALG
The following fields determine what channel to read and how to compress the data:
=fields ALG, INP, NSAM, N, ILIL, IHIL, OFF, RES
As stated above, the ALG field specifies which algorithm to be performed on the data.
The INP should be a database or channel access link. Though INP can be a constant,
the data compression algorithms are supported only when INP is a database link. See
L<Address Specification> for information on specifying links.
IHIL and ILIL can be set to provide an initial value filter on the input array.
If ILIL E<lt> IHIL, the input elements will be skipped until a value is found
that is in the range of ILIL to IHIL. Note that ILIL and IHIL are used only in
C<<< N to 1 >>> algorithms.
OFF provides the offset to the current beginning of the array data.
Note that OFF is used only in C<<< N to 1 >>> algorithms.
The RES field can be accessed at run time to cause the algorithm to reset
itself before the maximum number of samples are reached.
=head4 Algorithms
B<Circular Buffer> algorithm keeps a circular buffer of length NSAM.
Each time the record is processed, it gets the data referenced by INP and puts
it into the circular buffer referenced by VAL. The INP can refer to both scalar or
array data and VAL is just a time ordered circular buffer of values obtained
from INP.
Note that N, ILIL, IHIL and OFF are not used in C<<< Circular Buffer >>> algorithm.
B<Average> takes an average of every element of the array obtained from
INP over time; that is, the entire array referenced by INP is retrieved, and for
each element, the new average is calculated and placed in the corresponding
element of the value buffer. The retrieved array is truncated to be of length
NSAM. N successive arrays are averaged and placed in the buffer. Thus, VAL[0]
holds the average of the first element of INP over N samples, VAL[1] holds the
average of the next element of INP over N samples, and so on. The following
shows the equation:
=for comment Latex form of equation bellow : VAL[i] \leftarrow \frac{1}{N}\sum_{n=1}^NINP_{n}[i]
=begin html
<img src="image/compress-1.png">
=end html
B<N to 1> If any of the C<<< N to 1 >>> algorithms are chosen, then VAL is a circular
buffer of NSAM samples.
The actual algorithm depends on whether INP references a scalar or an array.
If INP refers to a scalar, then N successive time ordered samples of INP are taken.
After the Nth sample is obtained, a new value determined by the algorithm
(Lowest, Highest, or Average), is written to the circular buffer referenced by
VAL. If C<<< Low Value >>> the lowest value of all the samples is written; if
C<<< High Value >>> the highest value is written; and if C<<< Average >>>, the
average of all the samples are written. The C<<< Median >>> setting behaves
like C<<< Average >>> with scalar input data.
If INP refers to an array, then the following applies:
=over
=item C<<< N to 1 Low Value >>>
Compress N to 1 samples, keeping the lowest value.
=item C<<< N to 1 High Value >>>
Compress N to 1 samples, keeping the highest value.
=item C<<< N to 1 Average >>>
Compress N to 1 samples, taking the average value.
=item C<<< N to 1 Median >>>
Compress N to 1 samples, taking the median value.
=back
The compression record keeps NSAM data samples.
The field N determines the number of elements to compress into each result.
Thus, if NSAM was 3, and N was also equal to 3, then the algorithms would work
as in the following diagram:
=begin html
<img src="image/compress-2.png">
=end html
=head3 Operator Display Parameters
These parameters are used to present meaningful data to the operator. They
display the value and other parameters of the record either textually or
graphically.
=fields EGU, HOPR, LOPR, PREC, NAME, DESC
The EGU field should be given a string that describes the value of VAL, but is
used whenever the C<<< get_units >>> record support routine is called.
The HOPR and LOPR fields only specify the upper and lower display limits for
VAL, HIHI, HIGH, LOLO and LOW fields.
PREC controls the floating-point precision whenever C<<< get_precision >>> is
called, and the field being referenced is the VAL field (i.e., one of the values
contained in the circular buffer).
See L<Fields Common to All Record Types>
for more on the record name (NAME) and description (DESC) fields.
=head3 Alarm Parameters
The compression record has the alarm parameters common to all record types
described in L<Alarm Fields>.
=head3 Run-time Parameters
These parameters are used by the run-time code for processing the data
compression algorithm. They are not configurable by the user, though some are
accessible at run-time. They can represent the current state of the waveform or
of the record whose field is referenced by the INP field.
=fields NUSE, OUSE, BPTR, SPTR, WPTR, CVB, INPN, INX
NUSE and OUSE hold the current and previous number of elements stored in VAL.
BPTR is a pointer that refers to the buffer referenced by VAL.
SPTR points to an array that is used for array averages.
WPTR is used by the dbGetlinks routines.
=begin html
<br>
<hr>
<br>
=end html
=head2 Record Support
=head3 Record Support Routines (compressRecord.c)
=head4 init_record
long (*init_record)(struct dbCommon *precord, int pass)
Space for all necessary arrays is allocated. The addresses are stored in the
appropriate fields in the record.
=head4 process
long (*process)(struct dbCommon *precord)
See L<Record Processing>
=head4 special
long (*special)(struct dbAddr *paddr, int after)
This routine is called when RSET, ALG, or N are set. It performs a reset.
=head4 cvt_dbaddr
long (*cvt_dbaddr)(struct dbAddr *paddr)
This is called by dbNameToAddr. It makes the dbAddr structure refer to the
actual buffer holding the result.
=head4 get_array_info
long (*get_array_info)(struct dbAddr *paddr, long *no_elements, long *offset)
Obtains values from the circular buffer referenced by VAL.
=head4 put_array_info
long (*put_array_info)(struct dbAddr *paddr, long nNew);
Writes values into the circular buffer referenced by VAL.
=head4 get_units
long (*get_units)(struct dbAddr *paddr, char *units);
Retrieves EGU.
=head4 get_precision
long (*get_precision)(const struct dbAddr *paddr, long *precision);
Retrieves PREC.
=head4 get_graphic_double
long (*get_graphic_double)(struct dbAddr *paddr, struct dbr_grDouble *p);
Sets the upper display and lower display limits for a field. If the field is
VAL, the limits are set to HOPR and LOPR, else if the field has upper and lower
limits defined they will be used, else the upper and lower maximum values for
the field type will be used.
=head4 get_control_double
long (*get_control_double)(struct dbAddr *paddr, struct dbr_ctrlDouble *p);
Sets the upper control and the lower control limits for a field. If the field is
VAL, the limits are set to HOPR and LOPR, else if the field has upper and lower
limits defined they will be used, else the upper and lower maximum values for
the field type will be used.
=head3 Record Processing
Routine process implements the following algorithm:
=over
=item 1.
If INP is not a database link, check monitors and the forward link and return.
=item 2.
Get the current data referenced by INP.
=item 3.
Perform the appropriate algorithm:
=over
=item *
Average: Read N successive instances of INP and perform an element by element
average. Until N instances have been obtained it just return without checking
monitors or the forward link. When N instances have been obtained complete the
algorithm, store the result in the VAL array, check monitors and the forward
link, and return.
=item *
Circular Buffer: Write the values obtained from INP into the VAL array as a
circular buffer, check monitors and the forward link, and return.
=item *
N to 1 xxx when INP refers to a scalar: Obtain N successive values from INP and
apply the N to 1 xxx algorithm to these values. Until N values are obtained
monitors and forward links are not triggered. When N successive values have been
obtained, complete the algorithm, check monitors and trigger the forward link,
and return.
=item *
N to 1 xxx when INP refers to an array: The ILIL and IHIL are honored if ILIL
E<lt> IHIL. The input array is divided into subarrays of length N. The specified
N to 1 xxx compression algorithm is applied to each sub-array and the result
stored in the array referenced by VAL. The monitors and forward link are
checked.
=back
=item 4.
If success, set UDF to FALSE.
=item 5.
Check to see if monitors should be invoked:
=over
=item *
Alarm monitors are invoked if the alarm status or severity has changed.
=item *
NSEV and NSTA are reset to 0.
=back
=item 6.
Scan forward link if necessary, set PACT FALSE, and return.
=back
=cut
@@ -197,3 +549,4 @@ recordtype(compress) {
interest(3)
}
}

View File

@@ -379,11 +379,6 @@ and the DOL link, a non-zero value is returned if an error occurs.
See next section.
=head2 C<get_value()>
This routine fills in the members of C<struct valueDes> with the VAL fields
value and characteristics.
=head2 C<get_units()>
The routine copies the string specified in the EGU field to the location

View File

@@ -199,9 +199,9 @@ static long readValue(eventRecord *prec)
}
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -1,82 +0,0 @@
#*************************************************************************
# Copyright (c) 2002 The University of Chicago, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE is distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
recordtype(event) {
include "dbCommon.dbd"
field(VAL,DBF_STRING) {
prompt("Event Name To Post")
promptgroup("40 - Input")
special(SPC_MOD)
asl(ASL0)
size(40)
}
%#include "dbScan.h"
field(EPVT, DBF_NOACCESS) {
prompt("Event private")
special(SPC_NOMOD)
interest(4)
extra("EVENTPVT epvt")
}
field(INP,DBF_INLINK) {
prompt("Input Specification")
promptgroup("40 - Input")
interest(1)
}
field(SIOL,DBF_INLINK) {
prompt("Simulation Input Link")
promptgroup("90 - Simulate")
interest(1)
}
field(SVAL,DBF_STRING) {
prompt("Simulation Value")
size(40)
}
field(SIML,DBF_INLINK) {
prompt("Simulation Mode Link")
promptgroup("90 - Simulate")
interest(1)
}
field(SIMM,DBF_MENU) {
prompt("Simulation Mode")
special(SPC_MOD)
interest(1)
menu(menuYesNo)
}
field(SIMS,DBF_MENU) {
prompt("Simulation Mode Severity")
promptgroup("90 - Simulate")
interest(2)
menu(menuAlarmSevr)
}
field(OLDSIMM,DBF_MENU) {
prompt("Prev. Simulation Mode")
special(SPC_NOMOD)
interest(4)
menu(menuSimm)
}
field(SSCN,DBF_MENU) {
prompt("Sim. Mode Scan")
promptgroup("90 - Simulate")
interest(1)
menu(menuScan)
initial("65535")
}
field(SDLY,DBF_DOUBLE) {
prompt("Sim. Mode Async Delay")
promptgroup("90 - Simulate")
interest(2)
initial("-1.0")
}
%#include "callback.h"
field(SIMPVT,DBF_NOACCESS) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
}
}

View File

@@ -0,0 +1,305 @@
#*************************************************************************
# Copyright (c) 2002 The University of Chicago, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE is distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
=title Event Record (event)
The normal use for this record type is to post an event and/or process a
forward link. Device support for this record can provide a hardware interrupt
handler routine for I/O Event-scanned records.
=head2 Parameter Fields
The records in this field fall into the following groups of parameters:
=over
=item *
scan parameters
=item *
read parameters
=item *
event number parameters
=item *
simulation mode parameters
=back
=recordtype event
=cut
recordtype(event) {
include "dbCommon.dbd"
=head3 Scan Parameters
The event record has the standard fields for specifying under what circumstances
it will be processed. If the SCAN field specifies C<I/O Intr>, then device
support will provide an interrupt handler, posting an event number when an I/O
interrupt occurs. These fields are listed in L<Scan Fields>. In addition,
L<Scanning Specification> explains how the scanning fields work. Note that I/O
event scanning is only supported for those card types that interrupt.
=head3 Event Number Parameters
The VAL field contains the event number read by the device support routines. It
is this number which is posted. For records that use C<Soft Channel> device
support, it can be configured before run-time or set via dbPuts.
=fields VAL
=cut
field(VAL,DBF_STRING) {
prompt("Event Name To Post")
promptgroup("40 - Input")
special(SPC_MOD)
asl(ASL0)
size(40)
}
%#include "dbScan.h"
field(EPVT, DBF_NOACCESS) {
prompt("Event private")
special(SPC_NOMOD)
interest(4)
extra("EVENTPVT epvt")
}
=head3 Input Specification
The device support routines use the address in this record to obtain input. For
records that provide an interrupt handler, the INP field should specify the
address of the I/O card, and the DTYP field should specify a valid device
support module. Be aware that the address format differs according to the card
type used. See L<Address Specification> for information on the format of
hardware addresses and specifying links.
For soft records, the INP field can be a constant, a database link, or a channel
access link. For soft records, the DTYP field should specify C<Soft Channel>.
=fields INP, DTYP
=cut
field(INP,DBF_INLINK) {
prompt("Input Specification")
promptgroup("40 - Input")
interest(1)
}
=head3 Operator Display Parameters
See L<Fields Common to All Record Types> for more on the record name (NAME) and
description (DESC) fields.
=fields NAME, DESC
=head3 Alarm Parameters
The Event record has the alarm parameters common to all record types. L<Alarm
Fields> lists other fields related to alarms that are common to all record
types.
=head3 Simulation Mode Parameters
The following fields are used to operate the event record in the simulation
mode. See L<Fields Common to Many Record Types> for more information on these
fields.
=fields SIOL, SVAL, SIML, SIMM, SIMS
=cut
field(SIOL,DBF_INLINK) {
prompt("Sim Input Specifctn")
promptgroup("90 - Simulate")
interest(1)
}
field(SVAL,DBF_STRING) {
prompt("Simulation Value")
size(40)
}
field(SIML,DBF_INLINK) {
prompt("Sim Mode Location")
promptgroup("90 - Simulate")
interest(1)
}
field(SIMM,DBF_MENU) {
prompt("Simulation Mode")
special(SPC_MOD)
interest(1)
menu(menuYesNo)
}
field(SIMS,DBF_MENU) {
prompt("Sim mode Alarm Svrty")
promptgroup("90 - Simulate")
interest(2)
menu(menuAlarmSevr)
}
field(OLDSIMM,DBF_MENU) {
prompt("Prev. Simulation Mode")
special(SPC_NOMOD)
interest(4)
menu(menuSimm)
}
field(SSCN,DBF_MENU) {
prompt("Sim. Mode Scan")
promptgroup("90 - Simulate")
interest(1)
menu(menuScan)
initial("65535")
}
field(SDLY,DBF_DOUBLE) {
prompt("Sim. Mode Async Delay")
promptgroup("90 - Simulate")
interest(2)
initial("-1.0")
}
%#include "callback.h"
field(SIMPVT,DBF_NOACCESS) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("epicsCallback *simpvt")
}
=head2 Record Support
=head3 Record Support Routines
=head4 init_record
This routine initializes SIMM with the value of SIML if SIML type is a CONSTANT
link or creates a channel access link if SIML type is PV_LINK. SVAL is likewise
initialized if SIOL is CONSTANT or PV_LINK.
If device support includes C<init_record()>, it is called.
=head4 process
See next section.
=head3 Record Processing
Routine process implements the following algorithm:
=over
=item 1.
readValue is called. See L<Input Records> for more information.
=item 2.
If PACT has been changed to TRUE, the device support read routine has started
but has not completed reading a new input value. In this case, the processing
routine merely returns, leaving PACT TRUE.
=item 3.
If VAL E<gt> 0, post event number VAL.
=item 4.
Check to see if monitors should be invoked. Alarm monitors are invoked if the
alarm status or severity has chanet to 0.
=item 5.
Scan forward link if necessary, set PACT FALSE, and return.
=back
=head2 Device Support
=head3 Fields of Interest To Device Support
Each record must have an associated set of device support routines. The device
support routines are primarily interested in the following fields:
=fields PACT, DPVT, UDF, NSEV, NSTA, INP, PRIO
=head3 Device Support Routines
Device support consists of the following routines:
=head4 long report(int level)
This optional routine is called by the IOC command C<dbior> and is passed the
report level that was requested by the user.
It should print a report on the state of the device support to stdout.
The C<level> parameter may be used to output increasingly more detailed
information at higher levels, or to select different types of information with
different levels.
Level zero should print no more than a small summary.
=head4 long init(int after)
This optional routine is called twice at IOC initialization time.
The first call happens before any of the C<init_record()> calls are made, with
the integer parameter C<after> set to 0.
The second call happens after all of the C<init_record()> calls have been made,
with C<after> set to 1.
=head4 init_record
init_record(precord)
This routine is optional. If provided, it is called by the record support
C<init_record()> routine.
=head4 get_ioint_info
get_ioint_info(int cmd, struct dbCommon *precord, IOSCANPVT *ppvt)
This routine is called by the ioEventScan system each time the record is added
or deleted from an I/O event scan list. cmd has the value (0,1) if the record is
being (added to, deleted from) an I/O event list. It must be provided for any
device type that can use the ioEvent scanner.
=head4 read_event
read_event(precord)
This routine returns the following values:
=over
=item *
0: Success.
=item *
Other: Error.
=back
=head3 Device Support For Soft Records
The C<Soft Channel> device support module is available. The INP link type must
be either CONSTANT, DB_LINK, or CA_LINK.
If the INP link type is CONSTANT, then the constant value is stored into VAL by
C<init_record()>, and UDF is set to FALSE. If the INP link type is PV_LINK, then
dbCaAddInlink is called by C<init_record()>.
C<read_event> calls recGblGetLinkValue to read the current value of VAL. See
L<Input Records> for details on soft input.
=cut
}

View File

@@ -1,129 +0,0 @@
#*************************************************************************
# Copyright (c) 2012 UChicago Argonne LLC, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE is distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
menu(fanoutSELM) {
choice(fanoutSELM_All,"All")
choice(fanoutSELM_Specified,"Specified")
choice(fanoutSELM_Mask,"Mask")
}
recordtype(fanout) {
include "dbCommon.dbd"
field(VAL,DBF_LONG) {
prompt("Used to trigger")
asl(ASL0)
pp(TRUE)
}
field(SELM,DBF_MENU) {
prompt("Select Mechanism")
promptgroup("30 - Action")
interest(1)
menu(fanoutSELM)
}
field(SELN,DBF_USHORT) {
prompt("Link Selection")
interest(1)
initial("1")
}
field(SELL,DBF_INLINK) {
prompt("Link Selection Loc")
promptgroup("30 - Action")
interest(1)
}
field(OFFS,DBF_SHORT) {
prompt("Offset for Specified")
promptgroup("30 - Action")
interest(1)
initial("0")
}
field(SHFT,DBF_SHORT) {
prompt("Shift for Mask mode")
promptgroup("30 - Action")
interest(1)
initial("-1")
}
field(LNK0,DBF_FWDLINK) {
prompt("Forward Link 0")
promptgroup("51 - Output 0-7")
interest(1)
}
field(LNK1,DBF_FWDLINK) {
prompt("Forward Link 1")
promptgroup("51 - Output 0-7")
interest(1)
}
field(LNK2,DBF_FWDLINK) {
prompt("Forward Link 2")
promptgroup("51 - Output 0-7")
interest(1)
}
field(LNK3,DBF_FWDLINK) {
prompt("Forward Link 3")
promptgroup("51 - Output 0-7")
interest(1)
}
field(LNK4,DBF_FWDLINK) {
prompt("Forward Link 4")
promptgroup("51 - Output 0-7")
interest(1)
}
field(LNK5,DBF_FWDLINK) {
prompt("Forward Link 5")
promptgroup("51 - Output 0-7")
interest(1)
}
field(LNK6,DBF_FWDLINK) {
prompt("Forward Link 6")
promptgroup("51 - Output 0-7")
interest(1)
}
field(LNK7,DBF_FWDLINK) {
prompt("Forward Link 7")
promptgroup("51 - Output 0-7")
interest(1)
}
field(LNK8,DBF_FWDLINK) {
prompt("Forward Link 8")
promptgroup("52 - Output 8-F")
interest(1)
}
field(LNK9,DBF_FWDLINK) {
prompt("Forward Link 9")
promptgroup("52 - Output 8-F")
interest(1)
}
field(LNKA,DBF_FWDLINK) {
prompt("Forward Link 10")
promptgroup("52 - Output 8-F")
interest(1)
}
field(LNKB,DBF_FWDLINK) {
prompt("Forward Link 11")
promptgroup("52 - Output 8-F")
interest(1)
}
field(LNKC,DBF_FWDLINK) {
prompt("Forward Link 12")
promptgroup("52 - Output 8-F")
interest(1)
}
field(LNKD,DBF_FWDLINK) {
prompt("Forward Link 13")
promptgroup("52 - Output 8-F")
interest(1)
}
field(LNKE,DBF_FWDLINK) {
prompt("Forward Link 14")
promptgroup("52 - Output 8-F")
interest(1)
}
field(LNKF,DBF_FWDLINK) {
prompt("Forward Link 15")
promptgroup("52 - Output 8-F")
interest(1)
}
}

View File

@@ -0,0 +1,314 @@
#*************************************************************************
# Copyright (c) 2012 UChicago Argonne LLC, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE is distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
=title Fanout Record (fanout)
The fanout record uses several forward processing links to force multiple
passive records to scan. When more than one record needs to be scanned as the
result of a record being processed, the forward link of that record can specify
a fanout record. The fanout record can specify up to sixteen other records to
process. If more than sixteen are needed, one of the forward links in the fanout
record (or its FLNK field) can point to another fanout record.
B<NOTE: Fanout records only propagate processing, not data.> The dfanout or
data fanout record can, on the other hand, send data to other records.
=head2 Parameter Fields
The fanout record's fields fall into the following categories:
=over
=item *
scan parameters
=item *
operator display parameters
=item *
run-time parameters.
=back
=recordtype fanout
=cut
menu(fanoutSELM) {
choice(fanoutSELM_All,"All")
choice(fanoutSELM_Specified,"Specified")
choice(fanoutSELM_Mask,"Mask")
}
recordtype(fanout) {
include "dbCommon.dbd"
=head3 Scan Parameters
The forward link fields of the fanout record (LNK0-LNK9, LNKA-LNKF) specify
records to be scanned. The records to be processed must specify C<Passive> in
their SCAN fields; otherwise the forward link will not cause them to process.
Also when specifying database links for the fanout record, the user needs only
to specify the record name. As no value is being sent or retrieved, a field name
is only required when the link will be over Channel Access, in which case the
field PROC must be named.
The SELM, SELN, and SELL fields specify the order of processing for the forward
links. The select mechanism menu field (SELM) has three choices:
=menu fanoutSELM
How the SELM value affects which links to process and in which order is as
follows:
=over
=item *
B<All>
Links are processed in numerical order - LNK0, LNK1, etc.
=item *
B<Specified> The sum of the values in the SELN and OFFS fields is used as the
specifier of which link to process. For instance, with OFFS=0 and SELN=1, the
record targeted by LNK1 will be processed.
=item *
B<Mask> The individual bits in SELN are shifted by SHFT bits (negative means
shift left) and the result used to select which links to process as follows:
=over
=item *
If bit 0 (LSB) is set, LNK0 is processed.
=item *
If bit 1 is set, LNK2 is processed.
=item *
If bit 2 is set, LNK3 is processed, etc.
=back
=back
SELN reads its value from SELL. SELL can be a constant, a database link, or a
channel access link. If a constant, SELN is initialized with the constant value
and can be changed via dbPuts. For database/channel access links, SELN is
retrieved from SELL each time the record is processed and can also be changed
via dbPuts.
The Fanout record also has the standard scanning fields common to all records.
These fields are listed in L<Scan Fields>. In addition,
L<Scanning Specification> explains in more detail how forward links and the
scanning algorithms work.
=fields SELM, SELN, SELL, OFFS, SHFT, LNK0, LNK1, LNK2, LNK3, LNK4, LNK5, LNK6, LNK7, LNK8, LNK9, LNKA, LNKB, LNKC, LNKD, LNKE, LNKF
=cut
field(VAL,DBF_LONG) {
prompt("Used to trigger")
asl(ASL0)
pp(TRUE)
}
field(SELM,DBF_MENU) {
prompt("Select Mechanism")
promptgroup("30 - Action")
interest(1)
menu(fanoutSELM)
}
field(SELN,DBF_USHORT) {
prompt("Link Selection")
interest(1)
initial("1")
}
field(SELL,DBF_INLINK) {
prompt("Link Selection Loc")
promptgroup("30 - Action")
interest(1)
}
field(OFFS,DBF_SHORT) {
prompt("Offset for Specified")
promptgroup("30 - Action")
interest(1)
initial("0")
}
field(SHFT,DBF_SHORT) {
prompt("Shift for Mask mode")
promptgroup("30 - Action")
interest(1)
initial("-1")
}
field(LNK0,DBF_FWDLINK) {
prompt("Forward Link 0")
promptgroup("51 - Output 0-7")
interest(1)
}
field(LNK1,DBF_FWDLINK) {
prompt("Forward Link 1")
promptgroup("51 - Output 0-7")
interest(1)
}
field(LNK2,DBF_FWDLINK) {
prompt("Forward Link 2")
promptgroup("51 - Output 0-7")
interest(1)
}
field(LNK3,DBF_FWDLINK) {
prompt("Forward Link 3")
promptgroup("51 - Output 0-7")
interest(1)
}
field(LNK4,DBF_FWDLINK) {
prompt("Forward Link 4")
promptgroup("51 - Output 0-7")
interest(1)
}
field(LNK5,DBF_FWDLINK) {
prompt("Forward Link 5")
promptgroup("51 - Output 0-7")
interest(1)
}
field(LNK6,DBF_FWDLINK) {
prompt("Forward Link 6")
promptgroup("51 - Output 0-7")
interest(1)
}
field(LNK7,DBF_FWDLINK) {
prompt("Forward Link 7")
promptgroup("51 - Output 0-7")
interest(1)
}
field(LNK8,DBF_FWDLINK) {
prompt("Forward Link 8")
promptgroup("52 - Output 8-F")
interest(1)
}
field(LNK9,DBF_FWDLINK) {
prompt("Forward Link 9")
promptgroup("52 - Output 8-F")
interest(1)
}
field(LNKA,DBF_FWDLINK) {
prompt("Forward Link 10")
promptgroup("52 - Output 8-F")
interest(1)
}
field(LNKB,DBF_FWDLINK) {
prompt("Forward Link 11")
promptgroup("52 - Output 8-F")
interest(1)
}
field(LNKC,DBF_FWDLINK) {
prompt("Forward Link 12")
promptgroup("52 - Output 8-F")
interest(1)
}
field(LNKD,DBF_FWDLINK) {
prompt("Forward Link 13")
promptgroup("52 - Output 8-F")
interest(1)
}
field(LNKE,DBF_FWDLINK) {
prompt("Forward Link 14")
promptgroup("52 - Output 8-F")
interest(1)
}
field(LNKF,DBF_FWDLINK) {
prompt("Forward Link 15")
promptgroup("52 - Output 8-F")
interest(1)
}
=head3 Operator Display Parameters
These parameters are used to present meaningful data to the operator. See
L<Fields Common to All Record Types> for more on these fields.
=fields NAME, DESC
=head3 Alarm Parameters
The Fanout record has the alarm parameters common to all record types.
L<Alarm Fields> lists other fields related to a alarms that are common to all
record types.
=head3 Run-time Parameters
The VAL field performs no specific function, but a Channel Access put to it will
cause the record to process.
=fields VAL
=head2 Record Support
=head3 Record Support Routines
=head4 init_record
This routine initializes SELN with the value of SELL, if SELL type is CONSTANT
link, or creates a channel access link if SELL type is PV_LINK.
=head4 process
See next section.
=head3 Record Processing
Routine process implements the following algorithm:
=over
=item 1.
PACT is set to TRUE.
=item 2.
The link selection SELN is fetched.
=item 3.
Depending on the selection mechanism, the link selection forward links are
processed, and UDF is set to FALSE.
=item 4.
Check to see if monitors should be invoked:
=over
=item *
Alarm monitors are invoked if the alarm status or severity has changed.
=item *
NSEV and NSTA are reset to 0.
=back
=item 5.
Scan forward link field FLNK if used, set PACT FALSE, and return.
=back
=cut
}

View File

@@ -100,7 +100,7 @@ struct histogramdset { /* histogram input dset */
/* control block for callback*/
typedef struct myCallback {
CALLBACK callback;
epicsCallback callback;
histogramRecord *prec;
} myCallback;
@@ -110,7 +110,7 @@ static void monitor(histogramRecord *);
static long readValue(histogramRecord *);
static void wdogCallback(CALLBACK *arg)
static void wdogCallback(epicsCallback *arg)
{
myCallback *pcallback;
histogramRecord *prec;
@@ -403,9 +403,9 @@ static long readValue(histogramRecord *prec)
}
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -154,7 +154,7 @@ recordtype(histogram) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
field(HOPR,DBF_ULONG) {
prompt("High Operating Range")

Binary file not shown.

After

Width:  |  Height:  |  Size: 2.1 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 7.4 KiB

View File

@@ -420,9 +420,9 @@ static long readValue(int64inRecord *prec)
}
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -313,7 +313,7 @@ simulation mode.
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
}

View File

@@ -396,9 +396,9 @@ static long writeValue(int64outRecord *prec)
status = dbPutLink(&prec->siol, DBR_INT64, &prec->val, 1);
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -350,7 +350,7 @@ simulation mode.
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
=head3 Invalid Alarm Output Action

View File

@@ -428,9 +428,9 @@ static long readValue(longinRecord *prec)
}
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -1,188 +0,0 @@
#*************************************************************************
# Copyright (c) 2002 The University of Chicago, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE is distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
recordtype(longin) {
include "dbCommon.dbd"
field(VAL,DBF_LONG) {
prompt("Current value")
promptgroup("40 - Input")
asl(ASL0)
pp(TRUE)
}
field(INP,DBF_INLINK) {
prompt("Input Specification")
promptgroup("40 - Input")
interest(1)
}
field(EGU,DBF_STRING) {
prompt("Engineering Units")
promptgroup("80 - Display")
interest(1)
size(16)
prop(YES)
}
field(HOPR,DBF_LONG) {
prompt("High Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(LOPR,DBF_LONG) {
prompt("Low Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(HIHI,DBF_LONG) {
prompt("Hihi Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(LOLO,DBF_LONG) {
prompt("Lolo Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(HIGH,DBF_LONG) {
prompt("High Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(LOW,DBF_LONG) {
prompt("Low Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(HHSV,DBF_MENU) {
prompt("Hihi Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(LLSV,DBF_MENU) {
prompt("Lolo Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(HSV,DBF_MENU) {
prompt("High Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(LSV,DBF_MENU) {
prompt("Low Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(HYST,DBF_LONG) {
prompt("Alarm Deadband")
promptgroup("70 - Alarm")
interest(1)
}
field(AFTC, DBF_DOUBLE) {
prompt("Alarm Filter Time Constant")
promptgroup("70 - Alarm")
interest(1)
}
field(AFVL, DBF_DOUBLE) {
prompt("Alarm Filter Value")
special(SPC_NOMOD)
interest(3)
}
field(ADEL,DBF_LONG) {
prompt("Archive Deadband")
promptgroup("80 - Display")
interest(1)
}
field(MDEL,DBF_LONG) {
prompt("Monitor Deadband")
promptgroup("80 - Display")
interest(1)
}
field(LALM,DBF_LONG) {
prompt("Last Value Alarmed")
special(SPC_NOMOD)
interest(3)
}
field(ALST,DBF_LONG) {
prompt("Last Value Archived")
special(SPC_NOMOD)
interest(3)
}
field(MLST,DBF_LONG) {
prompt("Last Val Monitored")
special(SPC_NOMOD)
interest(3)
}
field(SIOL,DBF_INLINK) {
prompt("Simulation Input Link")
promptgroup("90 - Simulate")
interest(1)
}
field(SVAL,DBF_LONG) {
prompt("Simulation Value")
}
field(SIML,DBF_INLINK) {
prompt("Simulation Mode Link")
promptgroup("90 - Simulate")
interest(1)
}
field(SIMM,DBF_MENU) {
prompt("Simulation Mode")
special(SPC_MOD)
interest(1)
menu(menuYesNo)
}
field(SIMS,DBF_MENU) {
prompt("Simulation Mode Severity")
promptgroup("90 - Simulate")
interest(2)
menu(menuAlarmSevr)
}
field(OLDSIMM,DBF_MENU) {
prompt("Prev. Simulation Mode")
special(SPC_NOMOD)
interest(4)
menu(menuSimm)
}
field(SSCN,DBF_MENU) {
prompt("Sim. Mode Scan")
promptgroup("90 - Simulate")
interest(1)
menu(menuScan)
initial("65535")
}
field(SDLY,DBF_DOUBLE) {
prompt("Sim. Mode Async Delay")
promptgroup("90 - Simulate")
interest(2)
initial("-1.0")
}
%#include "callback.h"
field(SIMPVT,DBF_NOACCESS) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
}
}

View File

@@ -0,0 +1,555 @@
#*************************************************************************
# Copyright (c) 2002 The University of Chicago, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE is distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
=head1 Long Input Record (longin)
The normal use for the long input record or "longin" record is to retrieve a
long integer value of up to 32 bits. Device support routines are provided to
support direct interfaces to hardware. In addition, the C<<< Soft Channel >>>
device module is provided to obtain input via database or channel access links
or via dbPutField or dbPutLink requests.
=head1 Contents
=over
=item * L<Parameter Fields>
=over
=item * L<Scan Parameters>
=item * L<Read Parameters>
=item * L<Operator Display Parameters>
=item * L<Alarm Parameters>
=item * L<Run-time and Simulation Mode Parameters>
=back
=item * L<Record Support>
=over
=item * L<Record Support Routines>
=item * L<Record Processing>
=back
=item * L<Device Support>
=over
=item * L<Fields Of Interest To Device Support>
=item * L<Device Support Routines>
=item * L<Device Support For Soft Records>
=back
=back
=begin html
<br><hr><br>
=end html
=recordtype longin
=cut
recordtype(longin) {
=head2 Parameter Fields
The fields in this record fall into the following categories:
=over
=item * L<Scan Parameters>
=item * L<Read Parameters>
=item * L<Operator Display Parameters>
=item * L<Alarm Parameters>
=item * L<Run-time and Simulation Mode Parameters>
=back
=head3 Scan Parameters
The long input record has the standard fields for specifying under what
circumstances the record will be processed. These fields are listed in L<Scan
Fields>. In addition, L<Scanning Specification> explains how these fields are
used. Note that I/O event scanning is only supported for those card types
that interrupt.
=head3 Read Parameters
The device support routines use the INP field to obtain the record's input. For
records that obtain their input from devices, the INP field must contain the
address of the I/O card, and the DTYP field must specify the proper device
support module. Be aware that the address format differs according to the
I/O bus used.
For soft records, the INP can be a constant, a database link, or a channel
access link. The value is read directly into VAL. The C<<< Soft Channel >>>
device support module is available for longin records. See L<Address
Specification> for information on the format of hardware addresses and a
database links.
=fields VAL, INP, DTYP
=head3 Operator Display Parameters
These parameters are used to present meaningful data to the operator. These
fields are used to display the value and other parameters of the long input
either textually or graphically.
EGU is a string of up to 16 characters describing the units that the long input
measures. It is retrieved by the C<<< get_units >>> record support routine.
The HOPR and LOPR fields set the upper and lower display limits for the VAL,
HIHI, HIGH, LOW, and LOLO fields. Both the C<<< get_graphic_double >>> and C<<<
get_control_double >>> record support routines retrieve these fields.
See L<Fields Common to All Record Types> for more on the record name (NAME) and
description (DESC) fields.
=fields EGU, HOPR, LOPR, NAME, DESC
=head3 Alarm Parameters
The possible alarm conditions for long inputs are the SCAN, READ, and limit
alarms. The SCAN and READ alarms are called by the record or device support
routines.
The limit alarms are configured by the user in the HIHI, LOLO, HIGH, and LOW
fields using numerical values. For each of these fields, there is a
corresponding severity field which can be either NO_ALARM, MINOR, or MAJOR. The
HYST field can be used to specify a deadband around each limit. See L<Alarm
Specification> for a complete explanation of alarms and these fields. L<Alarm
Fields> lists other fields related to a alarms that are common to all record
types.
=fields HIHI, HIGH, LOW, LOLO, HHSV, HSV, LSV, LLSV, HYST
=head3 Monitor Parameters
These parameters are used to determine when to send monitors placed on the value
field. The monitors are sent when the value field exceeds the last monitored
field (see the next section) by the appropriate deadband. If these fields have a
value of zero, everytime the value changes, a monitor will be triggered; if they
have a value of -1, everytime the record is scanned, monitors are triggered. The
ADEL field is used by archive monitors and the MDEL field for all other types of
monitors. See L<Monitor Specification> for a complete explanation of monitors.
=fields ADEL, MDEL
=head3 Run-time and Simulation Mode Parameters
The LALM, MLST, and ALST fields are used to implement the hysteresis factors for
monitor callbacks. Only if the difference between these fields and the
corresponding value field is greater than the appropriate delta (MDEL, ADEL,
HYST)--only then are monitors triggered. For instance, only if the difference
between VAL and MLST is greater than MDEL are the monitors triggered for VAL.
=fields LALM, ALST, MLST
The following fields are used to operate the long input in the simulation mode.
See L<Fields Common to Many Record Types> for more information on these fields.
=fields SIOL, SVAL, SIML, SIMM, SIMS
=begin html
<br><hr><br>
=end html
=head2 Record Support
=head3 Record Support Routines
=head4 init_record
This routine initializes SIMM with the value of SIML if SIML type is CONSTANT
link or creates a channel access link if SIML type is PV_LINK. SVAL is likewise
initialized if SIOL is CONSTANT or PV_LINK.
This routine next checks to see that device support is available and a device
support read routine is defined. If either does not exist, an error message is
issued and processing is terminated.
If device support includes C<init_record()>, it is called.
=head4 process
See next section.
=head4 get_units
Retrieves EGU.
=head4 get_graphic_double
Sets the upper display and lower display limits for a field. If the field is
VAL, HIHI, HIGH, LOW, or LOLO, the limits are set to HOPR and LOPR, else if the
field has upper and lower limits defined they will be used, else the upper and
lower maximum values for the field type will be used.
=head4 get_control_double
Sets the upper control and the lower control limits for a field. If the field is
VAL, HIHI, HIGH, LOW, or LOLO, the limits are set to HOPR and LOPR, else if the
field has upper and lower limits defined they will be used, else the upper and
lower maximum values for the field type will be used.
=head4 get_alarm_double
Sets the following values:
upper_alarm_limit = HIHI
upper_warning_limit = HIGH
lower_warning_limit = LOW
lower_alarm_limit = LOLO
=head3 Record Processing
Routine process implements the following algorithm:
=over
=item 1.
Check to see that the appropriate device support module exists. If it doesn't,
an error message is issued and processing is terminated with the PACT field
still set to TRUE. This ensures that processes will no longer be called for this
record. Thus error storms will not occur.
=item 2.
readValue is called. See L<Input Records> for more information.
=item 3.
If PACT has been changed to TRUE, the device support read routine has started
but has not completed reading a new input value. In this case, the processing
routine merely returns, leaving PACT TRUE.
=item 4.
Check alarms. This routine checks to see if the new VAL causes the alarm status
and severity to change. If so, NSEV, NSTA and LALM are set. It also honors the
alarm hysteresis factor (HYST). Thus the value must change by more than HYST
before the alarm status and severity is lowered.
=item 5.
Check to see if monitors should be invoked:
=over
=item *
Alarm monitors are invoked if the alarm status or severity has changed.
=item *
Archive and value change monitors are invoked if ADEL and MDEL conditions are
met.
=item *
NSEV and NSTA are reset to 0.
=back
=item 6.
Scan forward link if necessary, set PACT FALSE, and return.
=back
=begin html
<br><hr><br>
=end html
=head2 Device Support
=head3 Fields Of Interest To Device Support
Each long input record must have an associated set of device support routines.
The primary responsibility of the device support routines is to obtain a new
input value whenever read_longin is called. The device support routines are
primarily interested in the following fields:
=fields PACT, DPVT, UDF, NSEV, NSTA, VAL, INP
=head3 Device Support Routines
Device support consists of the following routines:
=head4 long report(int level)
This optional routine is called by the IOC command C<dbior> and is passed the
report level that was requested by the user.
It should print a report on the state of the device support to stdout.
The C<level> parameter may be used to output increasingly more detailed
information at higher levels, or to select different types of information with
different levels.
Level zero should print no more than a small summary.
=head4 long init(int after)
This optional routine is called twice at IOC initialization time.
The first call happens before any of the C<init_record()> calls are made, with
the integer parameter C<after> set to 0.
The second call happens after all of the C<init_record()> calls have been made,
with C<after> set to 1.
=head4 init_record
init_record(precord)
This routine is optional. If provided, it is called by the record support
C<init_record()> routine.
=head4 get_ioint_info
get_ioint_info(int cmd,struct dbCommon *precord,IOSCANPVT *ppvt)
This routine is called by the ioEventScan system each time the record is added
or deleted from an I/O event scan list. cmd has the value (0,1) if the
record is being (added to, deleted from) an I/O event list. It must be
provided for any device type that can use the ioEvent scanner.
=head4 read_longin
read_longin(precord)
This routine must provide a new input value. It returns the following values:
=over
=item *
0: Success. A new value is placed in VAL.
=item *
Other: Error.
=back
=head3 Device Support For Soft Records
The C<<< Soft Channel >>> device support module places a value directly in VAL.
If the INP link type is constant, then the constant value is stored into VAL by
C<init_record()>, and UDF is set to FALSE. If the INP link type is PV_LINK, then
dbCaAddInlink is called by C<init_record()>.
C<<< read_longin >>> calls recGblGetLinkValue to read the current value of VAL.
See L<Soft Input> for more information
If the return status of C<<< recGblGetLinkValue >>> is zero then read_longin
sets UDF to FALSE. read_longin returns the status of C<recGblGetLinkValue>.
=cut
include "dbCommon.dbd"
field(VAL,DBF_LONG) {
prompt("Current value")
promptgroup("40 - Input")
asl(ASL0)
pp(TRUE)
}
field(INP,DBF_INLINK) {
prompt("Input Specification")
promptgroup("40 - Input")
interest(1)
}
field(EGU,DBF_STRING) {
prompt("Engineering Units")
promptgroup("80 - Display")
interest(1)
size(16)
prop(YES)
}
field(HOPR,DBF_LONG) {
prompt("High Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(LOPR,DBF_LONG) {
prompt("Low Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(HIHI,DBF_LONG) {
prompt("Hihi Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(LOLO,DBF_LONG) {
prompt("Lolo Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(HIGH,DBF_LONG) {
prompt("High Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(LOW,DBF_LONG) {
prompt("Low Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(HHSV,DBF_MENU) {
prompt("Hihi Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(LLSV,DBF_MENU) {
prompt("Lolo Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(HSV,DBF_MENU) {
prompt("High Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(LSV,DBF_MENU) {
prompt("Low Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(HYST,DBF_LONG) {
prompt("Alarm Deadband")
promptgroup("70 - Alarm")
interest(1)
}
field(AFTC, DBF_DOUBLE) {
prompt("Alarm Filter Time Constant")
promptgroup("70 - Alarm")
interest(1)
}
field(AFVL, DBF_DOUBLE) {
prompt("Alarm Filter Value")
special(SPC_NOMOD)
interest(3)
}
field(ADEL,DBF_LONG) {
prompt("Archive Deadband")
promptgroup("80 - Display")
interest(1)
}
field(MDEL,DBF_LONG) {
prompt("Monitor Deadband")
promptgroup("80 - Display")
interest(1)
}
field(LALM,DBF_LONG) {
prompt("Last Value Alarmed")
special(SPC_NOMOD)
interest(3)
}
field(ALST,DBF_LONG) {
prompt("Last Value Archived")
special(SPC_NOMOD)
interest(3)
}
field(MLST,DBF_LONG) {
prompt("Last Val Monitored")
special(SPC_NOMOD)
interest(3)
}
field(SIOL,DBF_INLINK) {
prompt("Sim Input Specifctn")
promptgroup("90 - Simulate")
interest(1)
}
field(SVAL,DBF_LONG) {
prompt("Simulation Value")
}
field(SIML,DBF_INLINK) {
prompt("Sim Mode Location")
promptgroup("90 - Simulate")
interest(1)
}
field(SIMM,DBF_MENU) {
prompt("Simulation Mode")
special(SPC_MOD)
interest(1)
menu(menuYesNo)
}
field(SIMS,DBF_MENU) {
prompt("Sim mode Alarm Svrty")
promptgroup("90 - Simulate")
interest(2)
menu(menuAlarmSevr)
}
field(OLDSIMM,DBF_MENU) {
prompt("Prev. Simulation Mode")
special(SPC_NOMOD)
interest(4)
menu(menuSimm)
}
field(SSCN,DBF_MENU) {
prompt("Sim. Mode Scan")
promptgroup("90 - Simulate")
interest(1)
menu(menuScan)
initial("65535")
}
field(SDLY,DBF_DOUBLE) {
prompt("Sim. Mode Async Delay")
promptgroup("90 - Simulate")
interest(2)
initial("-1.0")
}
%#include "callback.h"
field(SIMPVT,DBF_NOACCESS) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("epicsCallback *simpvt")
}
}

View File

@@ -401,9 +401,9 @@ static long writeValue(longoutRecord *prec)
status = dbPutLink(&prec->siol, DBR_LONG, &prec->val, 1);
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -1,211 +0,0 @@
#*************************************************************************
# Copyright (c) 2002 The University of Chicago, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE is distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
recordtype(longout) {
include "dbCommon.dbd"
field(VAL,DBF_LONG) {
prompt("Desired Output")
promptgroup("50 - Output")
asl(ASL0)
pp(TRUE)
}
field(OUT,DBF_OUTLINK) {
prompt("Output Specification")
promptgroup("50 - Output")
interest(1)
}
field(DOL,DBF_INLINK) {
prompt("Desired Output Loc")
promptgroup("40 - Input")
interest(1)
}
field(OMSL,DBF_MENU) {
prompt("Output Mode Select")
promptgroup("50 - Output")
interest(1)
menu(menuOmsl)
}
field(EGU,DBF_STRING) {
prompt("Engineering Units")
promptgroup("80 - Display")
interest(1)
size(16)
prop(YES)
}
field(DRVH,DBF_LONG) {
prompt("Drive High Limit")
promptgroup("30 - Action")
pp(TRUE)
interest(1)
prop(YES)
}
field(DRVL,DBF_LONG) {
prompt("Drive Low Limit")
promptgroup("30 - Action")
pp(TRUE)
interest(1)
prop(YES)
}
field(HOPR,DBF_LONG) {
prompt("High Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(LOPR,DBF_LONG) {
prompt("Low Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(HIHI,DBF_LONG) {
prompt("Hihi Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(LOLO,DBF_LONG) {
prompt("Lolo Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(HIGH,DBF_LONG) {
prompt("High Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(LOW,DBF_LONG) {
prompt("Low Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(HHSV,DBF_MENU) {
prompt("Hihi Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(LLSV,DBF_MENU) {
prompt("Lolo Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(HSV,DBF_MENU) {
prompt("High Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(LSV,DBF_MENU) {
prompt("Low Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(HYST,DBF_LONG) {
prompt("Alarm Deadband")
promptgroup("70 - Alarm")
interest(1)
}
field(ADEL,DBF_LONG) {
prompt("Archive Deadband")
promptgroup("80 - Display")
interest(1)
}
field(MDEL,DBF_LONG) {
prompt("Monitor Deadband")
promptgroup("80 - Display")
interest(1)
}
field(LALM,DBF_LONG) {
prompt("Last Value Alarmed")
special(SPC_NOMOD)
interest(3)
}
field(ALST,DBF_LONG) {
prompt("Last Value Archived")
special(SPC_NOMOD)
interest(3)
}
field(MLST,DBF_LONG) {
prompt("Last Val Monitored")
special(SPC_NOMOD)
interest(3)
}
field(SIOL,DBF_OUTLINK) {
prompt("Simulation Output Link")
promptgroup("90 - Simulate")
interest(1)
}
field(SIML,DBF_INLINK) {
prompt("Simulation Mode Link")
promptgroup("90 - Simulate")
interest(1)
}
field(SIMM,DBF_MENU) {
prompt("Simulation Mode")
special(SPC_MOD)
interest(1)
menu(menuYesNo)
}
field(SIMS,DBF_MENU) {
prompt("Simulation Mode Severity")
promptgroup("90 - Simulate")
interest(2)
menu(menuAlarmSevr)
}
field(OLDSIMM,DBF_MENU) {
prompt("Prev. Simulation Mode")
special(SPC_NOMOD)
interest(4)
menu(menuSimm)
}
field(SSCN,DBF_MENU) {
prompt("Sim. Mode Scan")
promptgroup("90 - Simulate")
interest(1)
menu(menuScan)
initial("65535")
}
field(SDLY,DBF_DOUBLE) {
prompt("Sim. Mode Async Delay")
promptgroup("90 - Simulate")
interest(2)
initial("-1.0")
}
%#include "callback.h"
field(SIMPVT,DBF_NOACCESS) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
}
field(IVOA,DBF_MENU) {
prompt("INVALID output action")
promptgroup("50 - Output")
interest(2)
menu(menuIvoa)
}
field(IVOV,DBF_LONG) {
prompt("INVALID output value")
promptgroup("50 - Output")
interest(2)
}
}

View File

@@ -0,0 +1,643 @@
#*************************************************************************
# Copyright (c) 2002 The University of Chicago, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE is distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
=head1 B<Long Output Record (longout)>
The normal use for the long output or "longout" record type is to store long
integer values of up to 32 bits and write them to hardware devices. The C<<<
Soft Channel >>> device support routine can also be used to write values to
other records via database or channel access links. The OUT field determines how
the record is used. The record supports alarm limits and graphics and control
limits.
=head1 L<Contents>
=over
=item * L<Parameter Fields>
=over
=item * L<Scan Parameters>
=item * L<Desired Output Parameters>
=item * L<Write Parameters>
=item * L<Operator Display Parameters>
=item * L<Alarm Parameters>
=item * L<Monitor Parameters>
=item * L<Simulation Mode Parameters>
=back
=item * L<Record Support>
=over
=item * L<Record Support Routines>
=item * L<Record Processing>
=back
=item * L<Device Support>
=over
=item * L<Fields Of Interest To Device Support>
=item * L<Device Support Routines>
=item * L<Device Support For Soft Records>
=back
=back
=begin html
<br><hr><br>
=end html
=recordtype longout
=cut
recordtype(longout) {
=head2 Parameter Fields
The fields in this record fall into the following categories:
=over
=item * L<Scan Parameters>
=item * L<Desired Output Parameters>
=item * L<Write Parameters>
=item * L<Operator Display Parameters>
=item * L<Alarm Parameters>
=item * L<Monitor Parameters>
=item * L<Simulation Mode Parameters>
=back
=head3 Scan Parameters
The longout record has the standard fields for specifying under what
circumstances it will be processed. These fields are listed in L<Scan Fields>.
In addition, L<Scanning Specification> explains how these fields are used. Note
that I/O event scanning is only supported for those card types that
interrupt.
=head3 Desired Output Parameters
The record must specify where the desired output originates, i.e., the 32 bit
integer value it is to write. The output mode select (OMSL) field determines
whether the output originates from another record or from database access. When
set to C<<< closed_loop >>>, the desired output is retrieved from the link
specified in the desired output (DOL) field (which can specify either a database
or channel access link) and placed into the VAL field. When set to C<<<
supervisory >>>, the desired output can be written into the VAL field via dpPuts
at run-time.
A third type of value for the DOL field is a constant in which case, when the
record is initialized, the VAL field will be initialized with this constant
value.
The VAL field's value will be clipped within limits specified in the fields DRVH
and DRVL if these have been configured by the database designer:
DRVL <= VAL <= DRVH
Note: These limits are only enforced as long as DRVH E<gt> DRVL. If they are not
set or DRVH E<lt>= DRVL they will not be used.
=fields DOL, OMSL, DRVH, DRVL, VAL
=head3 Write Parameters
The OUT link field determines where the record is to send its output. For
records that write values to hardware devices, the OUT output link field must
specify the address of the I/O card, and the DTYP field must specify the
name of the corresponding device support module.
For soft records, the OUT output link can be a constant, a database link, or a
channel access link. If the link is a constant, the result is no output. The
DTYP field must then specify the C<<< Soft Channel >>> device support routine.
See L<Address Specification> for information on the format of hardware addresses
and database links.
=fields OUT, DTYP
=cut
include "dbCommon.dbd"
field(VAL,DBF_LONG) {
prompt("Desired Output")
promptgroup("50 - Output")
asl(ASL0)
pp(TRUE)
}
field(OUT,DBF_OUTLINK) {
prompt("Output Specification")
promptgroup("50 - Output")
interest(1)
}
field(DOL,DBF_INLINK) {
prompt("Desired Output Loc")
promptgroup("40 - Input")
interest(1)
}
field(OMSL,DBF_MENU) {
prompt("Output Mode Select")
promptgroup("50 - Output")
interest(1)
menu(menuOmsl)
}
=head3 Operator Display Parameters
These parameters are used to present meaningful data to the operator. They
display the value and other parameters of the long output either textually or
graphically.
EGU is a string of up to 16 characters describing the units that the long output
measures. It is retrieved by the C<<< get_units >>> record support routine.
The HOPR and LOPR fields set the upper and lower display limits for the VAL,
HIHI, HIGH, LOW, and LOLO fields. Both the C<<< get_graphic_double >>> and C<<<
get_control_double >>> record support routines retrieve these fields.
See L<Fields Common to All Record Types> for more on the record name (NAME) and
description (DESC) fields.
=fields EGU, HOPR, LOPR, NAME, DESC
=cut
field(EGU,DBF_STRING) {
prompt("Engineering Units")
promptgroup("80 - Display")
interest(1)
size(16)
prop(YES)
}
field(DRVH,DBF_LONG) {
prompt("Drive High Limit")
promptgroup("30 - Action")
pp(TRUE)
interest(1)
prop(YES)
}
field(DRVL,DBF_LONG) {
prompt("Drive Low Limit")
promptgroup("30 - Action")
pp(TRUE)
interest(1)
prop(YES)
}
field(HOPR,DBF_LONG) {
prompt("High Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(LOPR,DBF_LONG) {
prompt("Low Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
=head3 Alarm Parameters
The possible alarm conditions for long inputs are the SCAN, READ, INVALID, and
limit alarms. The SCAN and READ alarms are not configurable by the user because
their severity is always MAJOR. The INVALID alarm is called by the record
support routine when the record or device support routines cannot write the
record's output. The IVOA field specifies the action to take in this case.
The limit alarms are configured by the user in the HIHI, LOLO, HIGH, and LOW
fields using floating-point values. For each of these fields, there is a
corresponding severity field which can be either NO_ALARM, MINOR, or MAJOR. The
HYST field contains the alarm deadband around each limit alarm.
See the See L<Alarm Specification> for a complete explanation of alarms and
these fields. For an explanation of the IVOA and IVOV fields, see L<Output
Records>. L<Alarm Fields> lists other fields related to a alarms that are common
to all record types.
=fields HIHI, HIGH, LOW, LOLO, HHSV, HSV, LSV, LLSV, HYST, IVOA, IVOV
=cut
field(HIHI,DBF_LONG) {
prompt("Hihi Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(LOLO,DBF_LONG) {
prompt("Lolo Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(HIGH,DBF_LONG) {
prompt("High Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(LOW,DBF_LONG) {
prompt("Low Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(HHSV,DBF_MENU) {
prompt("Hihi Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(LLSV,DBF_MENU) {
prompt("Lolo Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(HSV,DBF_MENU) {
prompt("High Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(LSV,DBF_MENU) {
prompt("Low Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(HYST,DBF_LONG) {
prompt("Alarm Deadband")
promptgroup("70 - Alarm")
interest(1)
}
=head3 Monitor Parameters
These parameters are used to determine when to send monitors placed on the value
field. The monitors are sent when the value field exceeds the last monitored
field by the appropriate delta. If these fields have a value of zero, everytime
the value changes, a monitor will be triggered; if they have a value of -1,
everytime the record is scanned, monitors are triggered. The ADEL field is the
delta for archive monitors, and the MDEL field is the delta for all other types
of monitors. See L<Monitor Specification> for a complete explanation of
monitors.
=fields ADEL, MDEL
=cut
field(ADEL,DBF_LONG) {
prompt("Archive Deadband")
promptgroup("80 - Display")
interest(1)
}
field(MDEL,DBF_LONG) {
prompt("Monitor Deadband")
promptgroup("80 - Display")
interest(1)
}
field(LALM,DBF_LONG) {
prompt("Last Value Alarmed")
special(SPC_NOMOD)
interest(3)
}
field(ALST,DBF_LONG) {
prompt("Last Value Archived")
special(SPC_NOMOD)
interest(3)
}
field(MLST,DBF_LONG) {
prompt("Last Val Monitored")
special(SPC_NOMOD)
interest(3)
}
=head3 Run-time and Simulation Mode Parameters
The LALM, MLST, and ALST fields are used to implement the hysteresis factors for
monitor callbacks. Only if the difference between these fields and the
corresponding value field is greater than the appropriate delta (MDEL, ADEL,
HYST)--only then are monitors triggered. For instance, only if the difference
between VAL and MLST is greater than MDEL are the monitors triggered for VAL.
=fields LALM, ALST, MLST
The following fields are used to operate the long output in the simulation mode.
See L<Fields Common to Many Record Types> for more information on the simulation
mode fields
=fields SIOL, SIML, SIMM, SIMS
=cut
field(SIOL,DBF_OUTLINK) {
prompt("Sim Output Specifctn")
promptgroup("90 - Simulate")
interest(1)
}
field(SIML,DBF_INLINK) {
prompt("Sim Mode Location")
promptgroup("90 - Simulate")
interest(1)
}
field(SIMM,DBF_MENU) {
prompt("Simulation Mode")
special(SPC_MOD)
interest(1)
menu(menuYesNo)
}
field(SIMS,DBF_MENU) {
prompt("Sim mode Alarm Svrty")
promptgroup("90 - Simulate")
interest(2)
menu(menuAlarmSevr)
}
field(OLDSIMM,DBF_MENU) {
prompt("Prev. Simulation Mode")
special(SPC_NOMOD)
interest(4)
menu(menuSimm)
}
field(SSCN,DBF_MENU) {
prompt("Sim. Mode Scan")
promptgroup("90 - Simulate")
interest(1)
menu(menuScan)
initial("65535")
}
field(SDLY,DBF_DOUBLE) {
prompt("Sim. Mode Async Delay")
promptgroup("90 - Simulate")
interest(2)
initial("-1.0")
}
%#include "callback.h"
field(SIMPVT,DBF_NOACCESS) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("epicsCallback *simpvt")
}
field(IVOA,DBF_MENU) {
prompt("INVALID output action")
promptgroup("50 - Output")
interest(2)
menu(menuIvoa)
}
field(IVOV,DBF_LONG) {
prompt("INVALID output value")
promptgroup("50 - Output")
interest(2)
}
=begin html
<br><hr><br>
=end html
=head2 Record Support
=head3 Record Support Routines
=head4 init_record
This routine initializes SIMM if SIML is a constant or creates a channel access
link if SIML is PV_LINK. If SIOL is PV_LINK a channel access link is created.
This routine next checks to see that device support is available. The routine
next checks to see if the device support write routine is defined.
If either device support or the device support write routine does not exist, an
error message is issued and processing is terminated.
If DOL is a constant, then VAL is initialized to its value and UDF is set to
FALSE. If DOL type is a PV_LINK then dbCaAddInlink is called to create a channel
access link.
If device support includes C<init_record()>, it is called.
=head4 process
See next section.
=head4 get_units
Retrieves EGU.
=head4 get_graphic_double
Sets the upper display and lower display limits for a field. If the field is
VAL, HIHI, HIGH, LOW, or LOLO, the limits are set to HOPR and LOPR, else if the
field has upper and lower limits defined they will be used, else the upper and
lower maximum values for the field type will be used.
=head4 get_control_double
Sets the upper control and the lower control limits for a field. If the field is
VAL, HIHI, HIGH, LOW, or LOLO, the limits are set to HOPR and LOPR, else if the
field has upper and lower limits defined they will be used, else the upper and
lower maximum values for the field type will be used.
=head4 get_alarm_double
Sets the following values:
upper_alarm_limit = HIHI
upper_warning_limit = HIGH
lower_warning_limit = LOW
lower_alarm_limit = LOLO
=head3 Record Processing
Routine process implements the following algorithm:
=over
=item 1.
Check to see that the appropriate device support module exists. If it doesn't,
an error message is issued and processing is terminated with the PACT field
still set to TRUE. This ensures that processes will no longer be called for this
record. Thus error storms will not occur.
=item 2.
If PACT is FALSE and OMSL is CLOSED_LOOP recGblGetLinkValue is called to read
the current value of VAL. See L<Output Records> for more information. If the
return status of recGblGetLinkValue is zero then UDF is set to FALSE.
=item 3.
Check alarms. This routine checks to see if the new VAL causes the alarm status
and severity to change. If so, NSEV, NSTA and LALM are set. It also honors the
alarm hysteresis factor (HYST). Thus the value must change by more than HYST
before the alarm status and severity is lowered.
=item 4.
Check severity and write the new value. See L<Invalid Alarm Output Action> for
information on how INVALID alarms affect output records.
=item 5.
If PACT has been changed to TRUE, the device support write output routine has
started but has not completed writing the new value. In this case, the
processing routine merely returns, leaving PACT TRUE.
=item 6.
Check to see if monitors should be invoked:
=over
=item *
Alarm monitors are invoked if the alarm status or severity has changed.
=item *
Archive and value change monitors are invoked if ADEL and MDEL conditions are
met.
=item *
NSEV and NSTA are reset to 0.
=back
=item 7.
Scan forward link if necessary, set PACT FALSE, and return.
=back
=begin html
<br><hr><br>
=end html
=head2 Device Support
=head3 Fields Of Interest To Device Support
Each long output record must have an associated set of device support routines.
The primary responsibility of the device support routines is to output a new
value whenever write_longout is called. The device support routines are
primarily interested in the following fields:
=fields PACT, DPVT, NSEV, NSTA, OUT
=head3 Device Support Routines
Device support consists of the following routines:
=head4 long report(int level)
This optional routine is called by the IOC command C<dbior> and is passed the
report level that was requested by the user.
It should print a report on the state of the device support to stdout.
The C<level> parameter may be used to output increasingly more detailed
information at higher levels, or to select different types of information with
different levels.
Level zero should print no more than a small summary.
=head4 long init(int after)
This optional routine is called twice at IOC initialization time.
The first call happens before any of the C<init_record()> calls are made, with
the integer parameter C<after> set to 0.
The second call happens after all of the C<init_record()> calls have been made,
with C<after> set to 1.
=head4 init_record
init_record(precord)
This routine is optional. If provided, it is called by the record support
C<init_record()> routine.
=head4 get_ioint_info
get_ioint_info(int cmd,struct dbCommon *precord,IOSCANPVT *ppvt)
This routine is called by the ioEventScan system each time the record is added
or deleted from an I/O event scan list. cmd has the value (0,1) if the
record is being (added to, deleted from) an I/O event list. It must be
provided for any device type that can use the ioEvent scanner.
=head4 write_longout
write_longout(precord)
This routine must output a new value. It returns the following values:
=over
=item *
0: Success.
=item *
Other: Error.
=back
=head3 Device Support For Soft Records
The C<<< Soft Channel >>> module writes the current value of VAL.
If the OUT link type is PV_LINK, then dbCaAddInlink is called by
C<init_record()>.
write_longout calls recGblPutLinkValue to write the current value of VAL.
See L<Soft Output> for a further explanation.
=cut
} #end of the DBD file

View File

@@ -241,9 +241,9 @@ static long readValue(lsiRecord *prec)
if (status == 0) prec->udf = FALSE;
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -110,6 +110,6 @@ recordtype(lsi) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
}

View File

@@ -282,9 +282,9 @@ static long writeValue(lsoRecord *prec)
status = dbPutLinkLS(&prec->siol, prec->val, prec->len);
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -134,6 +134,6 @@ recordtype(lso) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
}

View File

@@ -277,9 +277,9 @@ static long readValue(mbbiDirectRecord *prec)
}
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -98,7 +98,7 @@ recordtype(mbbiDirect) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
field(B0,DBF_UCHAR) {
prompt("Bit 0")

View File

@@ -409,9 +409,9 @@ static long readValue(mbbiRecord *prec)
}
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -500,6 +500,6 @@ recordtype(mbbi) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
}

View File

@@ -375,9 +375,9 @@ static long writeValue(mbboDirectRecord *prec)
status = dbPutLink(&prec->siol, DBR_ULONG, &prec->val, 1);
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -118,7 +118,7 @@ recordtype(mbboDirect) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
field(IVOA,DBF_MENU) {
prompt("INVALID outpt action")

View File

@@ -458,9 +458,9 @@ static long writeValue(mbboRecord *prec)
status = dbPutLink(&prec->siol, DBR_USHORT, &prec->val, 1);
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -510,7 +510,7 @@ recordtype(mbbo) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
field(IVOA,DBF_MENU) {
prompt("INVALID outpt action")

View File

@@ -1,323 +0,0 @@
#*************************************************************************
# Copyright (c) 2002 The University of Chicago, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE is distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
menu(selSELM) {
choice(selSELM_Specified,"Specified")
choice(selSELM_High_Signal,"High Signal")
choice(selSELM_Low_Signal,"Low Signal")
choice(selSELM_Median_Signal,"Median Signal")
}
recordtype(sel) {
include "dbCommon.dbd"
field(VAL,DBF_DOUBLE) {
prompt("Result")
promptgroup("40 - Input")
asl(ASL0)
special(SPC_NOMOD)
}
field(SELM,DBF_MENU) {
prompt("Select Mechanism")
promptgroup("30 - Action")
menu(selSELM)
}
field(SELN,DBF_USHORT) {
prompt("Index value")
}
field(PREC,DBF_SHORT) {
prompt("Display Precision")
promptgroup("80 - Display")
interest(1)
}
field(NVL,DBF_INLINK) {
prompt("Index Value Location")
promptgroup("30 - Action")
interest(1)
}
field(INPA,DBF_INLINK) {
prompt("Input A")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPB,DBF_INLINK) {
prompt("Input B")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPC,DBF_INLINK) {
prompt("Input C")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPD,DBF_INLINK) {
prompt("Input D")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPE,DBF_INLINK) {
prompt("Input E")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPF,DBF_INLINK) {
prompt("Input F")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPG,DBF_INLINK) {
prompt("Input G")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPH,DBF_INLINK) {
prompt("Input H")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPI,DBF_INLINK) {
prompt("Input I")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPJ,DBF_INLINK) {
prompt("Input J")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPK,DBF_INLINK) {
prompt("Input K")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPL,DBF_INLINK) {
prompt("Input L")
promptgroup("42 - Input G-L")
interest(1)
}
field(EGU,DBF_STRING) {
prompt("Engineering Units")
promptgroup("80 - Display")
interest(1)
size(16)
prop(YES)
}
field(HOPR,DBF_DOUBLE) {
prompt("High Operating Rng")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(LOPR,DBF_DOUBLE) {
prompt("Low Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(HIHI,DBF_DOUBLE) {
prompt("Hihi Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(LOLO,DBF_DOUBLE) {
prompt("Lolo Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(HIGH,DBF_DOUBLE) {
prompt("High Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(LOW,DBF_DOUBLE) {
prompt("Low Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(HHSV,DBF_MENU) {
prompt("Hihi Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
menu(menuAlarmSevr)
}
field(LLSV,DBF_MENU) {
prompt("Lolo Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
menu(menuAlarmSevr)
}
field(HSV,DBF_MENU) {
prompt("High Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
menu(menuAlarmSevr)
}
field(LSV,DBF_MENU) {
prompt("Low Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
menu(menuAlarmSevr)
}
field(HYST,DBF_DOUBLE) {
prompt("Alarm Deadband")
promptgroup("70 - Alarm")
interest(1)
}
field(ADEL,DBF_DOUBLE) {
prompt("Archive Deadband")
promptgroup("80 - Display")
interest(1)
}
field(MDEL,DBF_DOUBLE) {
prompt("Monitor Deadband")
promptgroup("80 - Display")
interest(1)
}
field(A,DBF_DOUBLE) {
prompt("Value of Input A")
pp(TRUE)
}
field(B,DBF_DOUBLE) {
prompt("Value of Input B")
pp(TRUE)
}
field(C,DBF_DOUBLE) {
prompt("Value of Input C")
pp(TRUE)
}
field(D,DBF_DOUBLE) {
prompt("Value of Input D")
pp(TRUE)
}
field(E,DBF_DOUBLE) {
prompt("Value of Input E")
pp(TRUE)
}
field(F,DBF_DOUBLE) {
prompt("Value of Input F")
pp(TRUE)
}
field(G,DBF_DOUBLE) {
prompt("Value of Input G")
pp(TRUE)
}
field(H,DBF_DOUBLE) {
prompt("Value of Input H")
pp(TRUE)
}
field(I,DBF_DOUBLE) {
prompt("Value of Input I")
pp(TRUE)
}
field(J,DBF_DOUBLE) {
prompt("Value of Input J")
pp(TRUE)
}
field(K,DBF_DOUBLE) {
prompt("Value of Input K")
pp(TRUE)
}
field(L,DBF_DOUBLE) {
prompt("Value of Input L")
pp(TRUE)
}
field(LA,DBF_DOUBLE) {
prompt("Prev Value of A")
special(SPC_NOMOD)
interest(3)
}
field(LB,DBF_DOUBLE) {
prompt("Prev Value of B")
special(SPC_NOMOD)
interest(3)
}
field(LC,DBF_DOUBLE) {
prompt("Prev Value of C")
special(SPC_NOMOD)
interest(3)
}
field(LD,DBF_DOUBLE) {
prompt("Prev Value of D")
special(SPC_NOMOD)
interest(3)
}
field(LE,DBF_DOUBLE) {
prompt("Prev Value of E")
special(SPC_NOMOD)
interest(3)
}
field(LF,DBF_DOUBLE) {
prompt("Prev Value of F")
special(SPC_NOMOD)
interest(3)
}
field(LG,DBF_DOUBLE) {
prompt("Prev Value of G")
special(SPC_NOMOD)
interest(3)
}
field(LH,DBF_DOUBLE) {
prompt("Prev Value of H")
special(SPC_NOMOD)
interest(3)
}
field(LI,DBF_DOUBLE) {
prompt("Prev Value of I")
special(SPC_NOMOD)
interest(3)
}
field(LJ,DBF_DOUBLE) {
prompt("Prev Value of J")
special(SPC_NOMOD)
interest(3)
}
field(LK,DBF_DOUBLE) {
prompt("Prev Value of K")
special(SPC_NOMOD)
interest(3)
}
field(LL,DBF_DOUBLE) {
prompt("Prev Value of L")
special(SPC_NOMOD)
interest(3)
}
field(LALM,DBF_DOUBLE) {
prompt("Last Value Alarmed")
special(SPC_NOMOD)
interest(3)
}
field(ALST,DBF_DOUBLE) {
prompt("Last Value Archived")
special(SPC_NOMOD)
interest(3)
}
field(MLST,DBF_DOUBLE) {
prompt("Last Val Monitored")
special(SPC_NOMOD)
interest(3)
}
field(NLST,DBF_USHORT) {
prompt("Last Index Monitored")
special(SPC_NOMOD)
interest(3)
}
}

View File

@@ -0,0 +1,647 @@
#*************************************************************************
# Copyright (c) 2002 The University of Chicago, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE is distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
=pod
=head1 Select Record (sel)
The select record computes a value based on input obtained from up to 12
locations. The selection algorithm can be one of the following: C<<< Specified
>>>, C<<< High Signal >>>, C<<< Low Signal >>>, C<<< Median Signal >>>. Each
input can be a constant, a database link, or a channel access link.
=head2 Contents
=over
=item * L<Parameter Fields>
=over
=item * L<Scan Parameters>
=item * L<Read Parameters>
=item * L<Select Parameters>
=item * L<Operator Display Parameters>
=item * L<Alarm Parameters>
=item * L<Monitor Parameters>
=item * L<Run-time Parameters>
=back
=item * L<Record Support>
=over
=item * L<Record Support Routines (selRecord.c)>
=item * L<Record Processing>
=back
=back
=begin html
<br>
<hr>
<br>
=end html
=recordtype sel
=cut
menu(selSELM) {
choice(selSELM_Specified,"Specified")
choice(selSELM_High_Signal,"High Signal")
choice(selSELM_Low_Signal,"Low Signal")
choice(selSELM_Median_Signal,"Median Signal")
}
recordtype(sel) {
=head2 Parameter Fields
=head3 Scan Parameters
The select record has the standard fields for specifying under what
circumstances the record will be processed. These fields are listed in
L<Scan Fields>. In addition, L<Scanning Specification>
explains how these fields work.
=head3 Read Parameters
The INPA-L links determine where the selection record retrieves the values from
which it is to select or compute its final value. The INPA-L links are input
links configured by the user to be either constants, channel access links, or
database links. If channel access or database links, a value is retrieved for
each link and placed in the corresponding value field, A-L. If any input link is
a constant, the value field for that link will be initialized with the constant
value given to it and can be modified via dbPuts. See L<Address Specification>
for information on how to specify database links.
Any links not defined are ignored by the selection record and its algorithm. An
undefined link is any constant link whose value is 0. At initialization time,
the corresponding value links for such fields are set to NaN, which means
MISSING. The value field of an undefined link can be changed at run-time from
NaN to another value in order to define the link and its field. Note that all
undefined links must be recognized as such if the selection algorithm is to work
as expected.
=fields INPA, INPB, INPC, INPD, INPE, INPF, INPG, INPH, INPI, INPJ, INPK, INPL, A, B, C, D, E, F, G, H, I, J, K, L
=head3 Select Parameters
The selection algorithm is determined by three fields configurable by the user:
the select mechanism (SELM) field, the select number (SELN) field, and the index
value location (NVL) field.
The SELM field has four choices, i.e., four algorithms as follows:
=head4 Menu selSELM
=menu selSELM
The selection record's VAL field is determined differently for each algorithm.
For C<<< Specified >>>, the VAL field is set equal to the value field (A, B, C,
D, E, F, G, H, I, J, K, or L) specified by the SELN field. The SELN field
contains a
number from 0-11 which corresponds to the value field to be used (0 means use A;
1 means use B, etc.). How the NVL field is configured determines, in turn,
SELN's value. NVL is an input link from which a value for SELN can be retrieved,
Like most other input links NVL can be a constant, or a channel access or
database link. If NVL is a link, SELN is retrieved from the location in NVL. If
a constant, SELN is initialized to the value given to the constant and can be
changed via dbPuts. See L<Address Specification> for information on how to
specify database links.
The C<<< High Signal >>>, C<<< Low Signal >>>, and C<<< Median Signal >>>
algorithms do not use SELN or NVL. If C<<< High Signal >>> is chosen, VAL is set
equal to the highest value out of all the defined value fields (A-L). If C<<<
Low Signal >>> is chosen, VAL is set equal to lowest value of all the defined
fields (A-L). And if C<<< Median Signal >>> is chosen, VAL is set equal to the
median value of the defined value fields (A-L). (Note that these algorithms
select from the value fields; they do not select from the value field index. For
instance, C<<< Low Signal >>> will not select the A field's value unless the
value itself is the lowest of all the defined values.)
=fields SELM, SELN, NVL
=head3 Operator Display Parameters
These parameters are used to present meaningful data to the operator. They
display the value and other parameters of the select record either textually or
graphically.
EGU is a string of up to 16 characters describing the units that the selection
record manipulates. It is retrieved by the C<<< get_units >>> record support
routine.
The HOPR and LOPR fields set the upper and lower display limits for the VAL,
HIHI, HIGH, LOW, and LOLO fields. Both the C<<< get_graphic_double >>> and C<<<
get_control_double >>> record support routines retrieve these fields.
The PREC field determines the floating point precision with which to display
VAL. It is used whenever the C<<< get_precision >>> record support routine is
called.
See L<Fields Common to All Record Types> for more on the record name (NAME)
and description (DESC) fields.
=fields EGU, HOPR, LOPR, PREC, NAME, DESC
=head3 Alarm Parameters
The possible alarm conditions for select records are the SCAN, READ, and limit
alarms. The SCAN and READ alarms are called by the record or device support
routines. The limit alarms are configured by the user in the HIHI, LOLO, HIGH,
and LOW fields using numerical values. They specify conditions for the VAL
field. For each of these fields, there is a corresponding severity field which
can be either NO_ALARM, MINOR, or MAJOR. See L<Alarm Specification>
for a complete explanation of alarms and these fields. L<Alarm Fields>
lists other fields related to a alarms that are common to all record types.
=fields HIHI, HIGH, LOW, LOLO, HHSV, HSV, LSV, LLSV, HYST
=head3 Monitor Parameters
These fields are configurable by the user. They are used as deadbands for the
archiver and monitor calls for the VAL field. Unless, VAL changes by more than
the value specified by each, then the respective monitors will not be called. If
these fields have a value of zero, everytime the VAL changes, monitors are
triggered; if they have a value of -1, everytime the record is processed,
monitors are triggered. L<Monitor Specification>
gives a complete explanation of alarms and deadbands.
=fields ADEL, MDEL
=head3 Run-time Parameters
These parameters are used by the run-time code for processing the selection
record. They are not configurable prior to run-time, nor are they modifiable at
run-time. They represent the current state of the record. The record support
routines use some of them for more efficient processing.
The VAL field is the result of the selection record's processing. It can be
accessed in the normal way by another record or through database access, but is
not modifiable except by the record itself. The LALM, ALST, and the MLST are
used to implement the HYST, ADEL, and MDEL hysteresis factors for the alarms,
archiver, and monitors, respectively.
The LA-LL fields are used to implement the monitors for each of the value
fields, A-L. They represent previous input values. For example, unless LA is not
equal to A, no monitor is invoked for A.
=fields VAL, LALM, ALST, MLST, LA, LB, LC, LD, LE, LF, LG, LH, LI, LJ, LK, LL
=begin html
<br>
<hr>
<br>
=end html
=head2 Record Support
=head3 Record Support Routines (selRecord.c)
=head4 init_record
long (*init_record)(struct dbCommon *precord, int pass)
IF NVL is a constant, SELN is set to its value. If NVL is a PV_LINK a channel
access link is created.
For each constant input link, the corresponding value field is initialized with
the constant value (or NaN if the constant has the value 0).
For each input link that is of type PV_LINK, a database or channel access link
is created.
=head4 process
long (*process)(struct dbCommon *precord)
See L<Record Processing>.
=head4 get_units
long (*get_units)(struct dbAddr *paddr, char *units)
Retrieves EGU.
=head4 get_precision
long (*get_precision)(const struct dbAddr *paddr, long *precision)
Retrieves PREC.
=head4 get_graphic_double
long (*get_graphic_double)(struct dbAddr *paddr, struct dbr_grDouble *p)
Sets the upper display and lower display limits for a field. If the field is
VAL, HIHI, HIGH, LOW, or LOLO, the limits are set to HOPR and LOPR, else if the
field has upper and lower limits defined they will be used, else the upper and
lower maximum values for the field type will be used.
=head4 get_control_double
long (*get_control_double)(struct dbAddr *paddr, struct dbr_ctrlDouble *p)
Sets the upper control and the lower control limits for a field. If the field is
VAL, HIHI, HIGH, LOW, or LOLO, the limits are set to HOPR and LOPR, else if the
field has upper and lower limits defined they will be used, else the upper and
lower maximum values for the field type will be used.
=head4 get_alarm_double
long (*get_alarm_double)(struct dbAddr *paddr, struct dbr_alDouble *p)
Sets the following values:
upper_alarm_limit = HIHI
upper_warning_limit = HIGH
lower_warning_limit = LOW
lower_alarm_limit = LOLO
=head3 Record Processing
Routine process implements the following algorithm:
=over
=item 1.
If NVL is a database or channel access link, SELN is obtained from NVL. Fetch
all values if database or channel access links. If SELM is SELECTED, then only
the selected link is fetched.
=item 2.
Implement the appropriate selection algorithm. For SELECT_HIGH, SELECT_LOW, and
SELECT_MEDIAN, input fields are ignored if they are undefined. If success, UDF
is set to FALSE.
=item 3.
Check alarms. This routine checks to see if the new VAL causes the alarm status
and severity to change. If so, NSEV, NSTA, and LALM are set. It also honors the
alarm hysteresis factor (HYST). Thus the value must change by more than HYST
before the alarm status and severity is lowered.
=item 4.
Check to see if monitors should be invoked.
=over
=item *
Alarm monitors are invoked if the alarm status or severity has changed.
=item *
Archive and value change monitors are invoked if ADEL and MDEL conditions are
met
=item *
Monitors for A-L are checked whenever other monitors are invoked
=item *
NSEV and NSTA are reset to 0.
=back
=item 5.
Scan forward link if necessary, set PACT FALSE, and return.
=back
=cut
include "dbCommon.dbd"
field(VAL,DBF_DOUBLE) {
prompt("Result")
promptgroup("40 - Input")
asl(ASL0)
special(SPC_NOMOD)
}
field(SELM,DBF_MENU) {
prompt("Select Mechanism")
promptgroup("30 - Action")
menu(selSELM)
}
field(SELN,DBF_USHORT) {
prompt("Index value")
}
field(PREC,DBF_SHORT) {
prompt("Display Precision")
promptgroup("80 - Display")
interest(1)
}
field(NVL,DBF_INLINK) {
prompt("Index Value Location")
promptgroup("30 - Action")
interest(1)
}
field(INPA,DBF_INLINK) {
prompt("Input A")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPB,DBF_INLINK) {
prompt("Input B")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPC,DBF_INLINK) {
prompt("Input C")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPD,DBF_INLINK) {
prompt("Input D")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPE,DBF_INLINK) {
prompt("Input E")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPF,DBF_INLINK) {
prompt("Input F")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPG,DBF_INLINK) {
prompt("Input G")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPH,DBF_INLINK) {
prompt("Input H")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPI,DBF_INLINK) {
prompt("Input I")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPJ,DBF_INLINK) {
prompt("Input J")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPK,DBF_INLINK) {
prompt("Input K")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPL,DBF_INLINK) {
prompt("Input L")
promptgroup("42 - Input G-L")
interest(1)
}
field(EGU,DBF_STRING) {
prompt("Engineering Units")
promptgroup("80 - Display")
interest(1)
size(16)
prop(YES)
}
field(HOPR,DBF_DOUBLE) {
prompt("High Operating Rng")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(LOPR,DBF_DOUBLE) {
prompt("Low Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(HIHI,DBF_DOUBLE) {
prompt("Hihi Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(LOLO,DBF_DOUBLE) {
prompt("Lolo Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(HIGH,DBF_DOUBLE) {
prompt("High Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(LOW,DBF_DOUBLE) {
prompt("Low Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(HHSV,DBF_MENU) {
prompt("Hihi Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
menu(menuAlarmSevr)
}
field(LLSV,DBF_MENU) {
prompt("Lolo Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
menu(menuAlarmSevr)
}
field(HSV,DBF_MENU) {
prompt("High Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
menu(menuAlarmSevr)
}
field(LSV,DBF_MENU) {
prompt("Low Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
menu(menuAlarmSevr)
}
field(HYST,DBF_DOUBLE) {
prompt("Alarm Deadband")
promptgroup("70 - Alarm")
interest(1)
}
field(ADEL,DBF_DOUBLE) {
prompt("Archive Deadband")
promptgroup("80 - Display")
interest(1)
}
field(MDEL,DBF_DOUBLE) {
prompt("Monitor Deadband")
promptgroup("80 - Display")
interest(1)
}
field(A,DBF_DOUBLE) {
prompt("Value of Input A")
pp(TRUE)
}
field(B,DBF_DOUBLE) {
prompt("Value of Input B")
pp(TRUE)
}
field(C,DBF_DOUBLE) {
prompt("Value of Input C")
pp(TRUE)
}
field(D,DBF_DOUBLE) {
prompt("Value of Input D")
pp(TRUE)
}
field(E,DBF_DOUBLE) {
prompt("Value of Input E")
pp(TRUE)
}
field(F,DBF_DOUBLE) {
prompt("Value of Input F")
pp(TRUE)
}
field(G,DBF_DOUBLE) {
prompt("Value of Input G")
pp(TRUE)
}
field(H,DBF_DOUBLE) {
prompt("Value of Input H")
pp(TRUE)
}
field(I,DBF_DOUBLE) {
prompt("Value of Input I")
pp(TRUE)
}
field(J,DBF_DOUBLE) {
prompt("Value of Input J")
pp(TRUE)
}
field(K,DBF_DOUBLE) {
prompt("Value of Input K")
pp(TRUE)
}
field(L,DBF_DOUBLE) {
prompt("Value of Input L")
pp(TRUE)
}
field(LA,DBF_DOUBLE) {
prompt("Prev Value of A")
special(SPC_NOMOD)
interest(3)
}
field(LB,DBF_DOUBLE) {
prompt("Prev Value of B")
special(SPC_NOMOD)
interest(3)
}
field(LC,DBF_DOUBLE) {
prompt("Prev Value of C")
special(SPC_NOMOD)
interest(3)
}
field(LD,DBF_DOUBLE) {
prompt("Prev Value of D")
special(SPC_NOMOD)
interest(3)
}
field(LE,DBF_DOUBLE) {
prompt("Prev Value of E")
special(SPC_NOMOD)
interest(3)
}
field(LF,DBF_DOUBLE) {
prompt("Prev Value of F")
special(SPC_NOMOD)
interest(3)
}
field(LG,DBF_DOUBLE) {
prompt("Prev Value of G")
special(SPC_NOMOD)
interest(3)
}
field(LH,DBF_DOUBLE) {
prompt("Prev Value of H")
special(SPC_NOMOD)
interest(3)
}
field(LI,DBF_DOUBLE) {
prompt("Prev Value of I")
special(SPC_NOMOD)
interest(3)
}
field(LJ,DBF_DOUBLE) {
prompt("Prev Value of J")
special(SPC_NOMOD)
interest(3)
}
field(LK,DBF_DOUBLE) {
prompt("Prev Value of K")
special(SPC_NOMOD)
interest(3)
}
field(LL,DBF_DOUBLE) {
prompt("Prev Value of L")
special(SPC_NOMOD)
interest(3)
}
field(LALM,DBF_DOUBLE) {
prompt("Last Value Alarmed")
special(SPC_NOMOD)
interest(3)
}
field(ALST,DBF_DOUBLE) {
prompt("Last Value Archived")
special(SPC_NOMOD)
interest(3)
}
field(MLST,DBF_DOUBLE) {
prompt("Last Val Monitored")
special(SPC_NOMOD)
interest(3)
}
field(NLST,DBF_USHORT) {
prompt("Last Index Monitored")
special(SPC_NOMOD)
interest(3)
}
}

View File

@@ -31,7 +31,7 @@
static void processNextLink(seqRecord *prec);
static long asyncFinish(seqRecord *prec);
static void processCallback(CALLBACK *arg);
static void processCallback(epicsCallback *arg);
/* Create RSET - Record Support Entry Table*/
#define report NULL
@@ -94,7 +94,7 @@ typedef struct linkGrp {
/* The list of link-groups for processing */
typedef struct seqRecPvt {
CALLBACK callback;
epicsCallback callback;
seqRecord *prec;
linkGrp *grps[NUM_LINKS + 1]; /* List of link-groups */
int index; /* Where we are now */
@@ -241,7 +241,7 @@ static long asyncFinish(seqRecord *prec)
}
static void processCallback(CALLBACK *arg)
static void processCallback(epicsCallback *arg)
{
seqRecPvt *pcb;
seqRecord *prec;

View File

@@ -1,365 +0,0 @@
#*************************************************************************
# Copyright (c) 2012 UChicago Argonne LLC, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE is distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
menu(seqSELM) {
choice(seqSELM_All,"All")
choice(seqSELM_Specified,"Specified")
choice(seqSELM_Mask,"Mask")
}
recordtype(seq) {
include "dbCommon.dbd"
field(VAL,DBF_LONG) {
prompt("Used to trigger")
asl(ASL0)
pp(TRUE)
}
field(SELM,DBF_MENU) {
prompt("Select Mechanism")
promptgroup("30 - Action")
interest(1)
menu(seqSELM)
}
field(SELN,DBF_USHORT) {
prompt("Link Selection")
interest(1)
initial("1")
}
field(SELL,DBF_INLINK) {
prompt("Link Selection Loc")
promptgroup("30 - Action")
interest(1)
}
field(OFFS,DBF_SHORT) {
prompt("Offset for Specified")
promptgroup("30 - Action")
interest(1)
initial("0")
}
field(SHFT,DBF_SHORT) {
prompt("Shift for Mask mode")
promptgroup("30 - Action")
interest(1)
initial("-1")
}
field(OLDN,DBF_USHORT) {
prompt("Old Selection")
interest(4)
}
field(PREC,DBF_SHORT) {
prompt("Display Precision")
promptgroup("80 - Display")
interest(1)
}
field(DLY0,DBF_DOUBLE) {
prompt("Delay 0")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DOL0,DBF_INLINK) {
prompt("Input link 0")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DO0,DBF_DOUBLE) {
prompt("Value 0")
interest(1)
}
field(LNK0,DBF_OUTLINK) {
prompt("Output Link 0")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DLY1,DBF_DOUBLE) {
prompt("Delay 1")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DOL1,DBF_INLINK) {
prompt("Input link1")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DO1,DBF_DOUBLE) {
prompt("Value 1")
interest(1)
}
field(LNK1,DBF_OUTLINK) {
prompt("Output Link 1")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DLY2,DBF_DOUBLE) {
prompt("Delay 2")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DOL2,DBF_INLINK) {
prompt("Input link 2")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DO2,DBF_DOUBLE) {
prompt("Value 2")
interest(1)
}
field(LNK2,DBF_OUTLINK) {
prompt("Output Link 2")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DLY3,DBF_DOUBLE) {
prompt("Delay 3")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DOL3,DBF_INLINK) {
prompt("Input link 3")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DO3,DBF_DOUBLE) {
prompt("Value 3")
interest(1)
}
field(LNK3,DBF_OUTLINK) {
prompt("Output Link 3")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DLY4,DBF_DOUBLE) {
prompt("Delay 4")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DOL4,DBF_INLINK) {
prompt("Input link 4")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DO4,DBF_DOUBLE) {
prompt("Value 4")
interest(1)
}
field(LNK4,DBF_OUTLINK) {
prompt("Output Link 4")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DLY5,DBF_DOUBLE) {
prompt("Delay 5")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DOL5,DBF_INLINK) {
prompt("Input link 5")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DO5,DBF_DOUBLE) {
prompt("Value 5")
interest(1)
}
field(LNK5,DBF_OUTLINK) {
prompt("Output Link 5")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DLY6,DBF_DOUBLE) {
prompt("Delay 6")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DOL6,DBF_INLINK) {
prompt("Input link 6")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DO6,DBF_DOUBLE) {
prompt("Value 6")
interest(1)
}
field(LNK6,DBF_OUTLINK) {
prompt("Output Link 6")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DLY7,DBF_DOUBLE) {
prompt("Delay 7")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DOL7,DBF_INLINK) {
prompt("Input link 7")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DO7,DBF_DOUBLE) {
prompt("Value 7")
interest(1)
}
field(LNK7,DBF_OUTLINK) {
prompt("Output Link 7")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DLY8,DBF_DOUBLE) {
prompt("Delay 8")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOL8,DBF_INLINK) {
prompt("Input link 8")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DO8,DBF_DOUBLE) {
prompt("Value 8")
interest(1)
}
field(LNK8,DBF_OUTLINK) {
prompt("Output Link 8")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DLY9,DBF_DOUBLE) {
prompt("Delay 9")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOL9,DBF_INLINK) {
prompt("Input link 9")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DO9,DBF_DOUBLE) {
prompt("Value 9")
interest(1)
}
field(LNK9,DBF_OUTLINK) {
prompt("Output Link 9")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DLYA,DBF_DOUBLE) {
prompt("Delay 10")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOLA,DBF_INLINK) {
prompt("Input link 10")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOA,DBF_DOUBLE) {
prompt("Value 10")
interest(1)
}
field(LNKA,DBF_OUTLINK) {
prompt("Output Link 10")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DLYB,DBF_DOUBLE) {
prompt("Delay 11")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOLB,DBF_INLINK) {
prompt("Input link 11")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOB,DBF_DOUBLE) {
prompt("Value 11")
interest(1)
}
field(LNKB,DBF_OUTLINK) {
prompt("Output Link 11")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DLYC,DBF_DOUBLE) {
prompt("Delay 12")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOLC,DBF_INLINK) {
prompt("Input link 12")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOC,DBF_DOUBLE) {
prompt("Value 12")
interest(1)
}
field(LNKC,DBF_OUTLINK) {
prompt("Output Link 12")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DLYD,DBF_DOUBLE) {
prompt("Delay 13")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOLD,DBF_INLINK) {
prompt("Input link 13")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOD,DBF_DOUBLE) {
prompt("Value 13")
interest(1)
}
field(LNKD,DBF_OUTLINK) {
prompt("Output Link 13")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DLYE,DBF_DOUBLE) {
prompt("Delay 14")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOLE,DBF_INLINK) {
prompt("Input link 14")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOE,DBF_DOUBLE) {
prompt("Value 14")
interest(1)
}
field(LNKE,DBF_OUTLINK) {
prompt("Output Link 14")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DLYF,DBF_DOUBLE) {
prompt("Delay 15")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOLF,DBF_INLINK) {
prompt("Input link 15")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOF,DBF_DOUBLE) {
prompt("Value 15")
interest(1)
}
field(LNKF,DBF_OUTLINK) {
prompt("Output Link 15")
promptgroup("42 - Link 8-F")
interest(1)
}
}
variable(seqDLYprecision, int)
variable(seqDLYlimit, double)

View File

@@ -0,0 +1,647 @@
#*************************************************************************
# Copyright (c) 2012 UChicago Argonne LLC, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE is distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
=title Sequence Record (seq)
The Sequence record is used to trigger the processing of up to ten other records
and send values to those records. It is similar to the fanout record, except
that it will fetch an input value and write an output value instead of simply
processing a collection of forward links. It can also specify one of several
selection algorithms that determine which values to write. It has no associated
device support.
=recordtype seq
=cut
menu(seqSELM) {
choice(seqSELM_All,"All")
choice(seqSELM_Specified,"Specified")
choice(seqSELM_Mask,"Mask")
}
recordtype(seq) {
=pod
=head1 Contents
=over
=item * L<Parameter Fields>
=over
=item * L<Scan Parameters>
=item * L<Desired Output Parameters>
=item * L<Output Parameters>
=item * L<Selection Algorithm Parameters>
=item * L<Delay Parameters>
=item * L<Operator Display Parameters>
=item * L<Alarm Parameters>
=back
=item * L<Record Support>
=back
=begin html
<br><hr><br>
=end html
=head2 Parameter Fields
The fields fall into the following categories:
=over
=item * L<Scan Parameters>
=item * L<Desired Output Parameters>
=item * L<Output Parameters>
=item * L<Selection Algorithm Parameters>
=item * L<Delay Parameters>
=item * L<Operator Display Parameters>
=item * L<Alarm Parameters>
=back
=head3 Scan Parameters
The sequence record has the standard fields for specifying under what
circumstances it will be processed. These fields are listed in L<Scan Fields>.
In addition, L<Scanning Specification> explains how these fields are used.
=head3 Desired Output Parameters
These fields determine where the record retrieves the values it is to write to
other records. All of these values are not necessarily used, depending on the
selection algorithm.
The sequence record can retrieve up to 16 values from 16 locations. The user
specifies the locations in the Desired Output Link fields (DOL0-DOLF), which can
be either constants, database links, or channel access links. If a Desired
Output Link is a constant, the corresponding value field for that link is
initialized to the constant value and ''cannot'' be changed via dbputs.
Otherwise, if the Desired Output Link is a database or channel access link, a
value is fetched from the link each time the record is processed (provided that
the output link is part of the record's selection algorithm). See L<Address
Specification> for information on how to specify database links.
The value fetched from the Desired Output Links are stored in the corresponding
Desired Output Value fields (DO0-DOF). These fields can be initialized to a
constant value, but they cannot be changed via dbPuts.
=head4 Desired Output Link Fields
=fields DOL0, DOL1, DOL2, DOL3, DOL4, DOL5, DOL6, DOL7, DOL8, DOL9, DOLA, DOLB, DOLC, DOLD, DOLE, DOLF
=head4 Desired Output Value Fields
=fields DO0, DO1, DO2, DO3, DO4, DO5, DO6, DO7, DO8, DO9, DOA, DOB, DOC, DOD, DOE, DOF
=head3 Output Parameters
When the record is processed, the desired output values are retrieved for the
links in the record's selection algorithm and are written to the corresponding
output link (LNK0-LNKF). These output links can be database links or channel
access links; they cannot be device addresses. There are sixteen output links, one
for each desired output link. Only those that are defined are used.
=fields LNK0, LNK1, LNK2, LNK3, LNK4, LNK5, LNK6, LNK7, LNK8, LNK9, LNKA, LNKB, LNKC, LNKD, LNKE, LNKF
=head3 Selection Algorithm Parameters
When the sequence record is processed, it uses a selection algorithm similar to
that of the selection record to decide which links to process.The select
mechanism field (SELM) has three algorithms to choose from: C<<< All >>>,
C<<<Specified >>> or C<<< Mask >>>.
=head4 Record fields related to the Selection Algorithm
=fields SELM, SELN, SELL, SHFT, OFFS
=head4 Fields Description
B<SELM - Selection Mode>
=menu seqSELM
See L<Selection Algorithms Description> below;
B<SELL - Link Selection Location>
This field can be initialized as a CONSTANT or as a LINK to any other record. SELN will fetch its value from this field when the seq record is processed.
Thus, when using I<Mask> or I<Specified> modes, the links that seq will process can be dinamically changed by the record pointed by SELL.
B<SELN - Link Selection>
When B<C<SELM = Specified>> this is the index number of the link that will be processed, used in combination with the C<OFFS> field:
SELN = SELN + OFFS
I<(By default, the OFFS is initalized to ZERO)>
When B<C<SELM = Mask>> this field is the bitmask that will be used to determine which links will be processed by the seq record,
in combination with the C<SHFT> field:
if (SHFT >= 0)
SELN = SELN << -SHFT
else
SELN = SELN >> SHFT
I<(By default, the SHFT is initalized to -1)>
=head4 B<Note about SHFT and OFFS fields>
The first versions of seq record had DO, DOL, LNK and DLY fields starting with index ONE (DO1, DOL1, LNK1 and DLY1).
New version of the seq record now supports 16 links, starting by index ZERO (DO0, DOL0, LNK0 and DLY0). The SHFT and OFFS fields
were introduced to keep compatibility of old databases that used seq record with its links indexed from one onwards.
B<If one wants to use DO0, DOL0, LNK0, DLY0 fields when SELM = Mask, SHFT field must be set to ZERO>
=head4 Selection Algorithms Description
B<All>
The C<<< All >>> algorithm causes the record to process each input and output
link each time the record is processed, in order from 0 to 15. So when SELM is
C<<< All >>>, the desired output value from DOL0 will fetched and sent to LNK0,
then the desired output value from DOL1 will be fetched and sent to the location
in LNK1, and so on until the last input and output link DOF and LNKF. (Note that
undefined links are not used.) If DOLI<x> is a constant, the current value
field is simply used and the desired output link is ignored. The SELN field is
not used when C<<< All >>> is the algorithm.
B<Specified>
When the C<<< Specified >>> algorithm is chosen, each time the record is
processed it gets the integer value in the Link Selection (SELN) field and uses
that as the index of the link to process. For instance, if SELN is 4, the
desired output value from DO4 will be retrieved and sent to LNK4. If DOLI<x> is
a constant, DOI<x> is simply used without the value being fetched from the
input link.
B<Mask>
When C<<< Mask >>> is chosen, the record uses the individual bits of the SELN
field to determine the links to process. When bit 0 of SELN is set, the value
from DO0 will be written to the location in LNK0; when bit 1 is set, the valud
from DO1 will be written to the location in LNK1 etc. Thus for example if SELN
is 3, the record will retrieve the values from DO0 and DO1 and write them to the
locations in LNK0 and LNK1, respectively. If SELN is 63, DO0...DO5 will be
written to LNK0...LNK5.
=head3 Delay Parameters
The delay parameters consist of 16 fields, one for each I/O link discussed
above. These fields can be configured to cause the record to delay processing
the link. For instance, if the user gives the DLY1 field a value of 3.0, each
time the record is processed at run-time, the record will delay processing the
DOL1, DOV1, and LNK1 fields for three seconds. That is, the desired output value
will not be fetched and written to the output link until three seconds have
lapsed.
=fields DLY0, DLY1, DLY2, DLY3, DLY4, DLY5, DLY6, DLY7, DLY8, DLY9, DLYA, DLYB, DLYC, DLYD, DLYE, DLYF
=head3 Operator Display Parameters
These parameters are used to present meaningful data to the operator. The
Precision field (PREC) determines the decimal precision for the VAL field when
it is displayed. It is used when the C<<< get_precision >>> record routine is
called.
See L<Fields Common to All Record Types> for more on the record name (NAME) and
description (DESC) fields.
=fields PREC, NAME, DESC
=head3 Alarm Parameters
The sequence record has the alarm parameters common to all record types.
L<Alarm Fields> lists other fields related to a alarms that are common to all
record types.
=head2 Record Support
=head3 Record Processing
Routine process implements the following algorithm:
=over
=item 1.
First, PACT is set to TRUE, and the link selection is fetched. Depending on the
selection mechanism, the link selection output links are processed in order from
LNK0 to LNKF. When LNKI<x> is processed, the corresponding DLYI<x> value is
used to generate a delay via watchdog timer.
=item 2.
After DLYI<x> seconds have expired, the input value is fetched from DOI<x> (if
DOLI<x> is constant) or DOLI<x> (if DOLI<x> is a database link or channel
access link) and written to LNKI<x>.
=item 3.
When all links are completed, an asynchronous completion call back to dbProcess
is made (see the Application Developer's Guide for more information on
asynchronous processing.)
=item 4.
Then UDF is set to FALSE.
=item 5.
Monitors are checked.
=item 6.
The forward link is scanned, PACT is set FALSE, and the process routine returns.
=back
For the delay mechanism to operate properly, the record is processed
asynchronously. The only time the record will not be processed asynchronously is
when there are no non-NULL output links selected (i.e. when it has nothing to
do.) The processing of the links is done via callback tasks at the priority set
in the PRIO field in dbCommon (see the Application Developer's Guide for more
information on call
=cut
include "dbCommon.dbd"
field(VAL,DBF_LONG) {
prompt("Used to trigger")
asl(ASL0)
pp(TRUE)
}
field(SELM,DBF_MENU) {
prompt("Select Mechanism")
promptgroup("30 - Action")
interest(1)
menu(seqSELM)
}
field(SELN,DBF_USHORT) {
prompt("Link Selection")
interest(1)
initial("1")
}
field(SELL,DBF_INLINK) {
prompt("Link Selection Loc")
promptgroup("30 - Action")
interest(1)
}
field(OFFS,DBF_SHORT) {
prompt("Offset for Specified")
promptgroup("30 - Action")
interest(1)
initial("0")
}
field(SHFT,DBF_SHORT) {
prompt("Shift for Mask mode")
promptgroup("30 - Action")
interest(1)
initial("-1")
}
field(OLDN,DBF_USHORT) {
prompt("Old Selection")
interest(4)
}
field(PREC,DBF_SHORT) {
prompt("Display Precision")
promptgroup("80 - Display")
interest(1)
}
field(DLY0,DBF_DOUBLE) {
prompt("Delay 0")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DOL0,DBF_INLINK) {
prompt("Input link 0")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DO0,DBF_DOUBLE) {
prompt("Value 0")
interest(1)
}
field(LNK0,DBF_OUTLINK) {
prompt("Output Link 0")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DLY1,DBF_DOUBLE) {
prompt("Delay 1")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DOL1,DBF_INLINK) {
prompt("Input link1")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DO1,DBF_DOUBLE) {
prompt("Value 1")
interest(1)
}
field(LNK1,DBF_OUTLINK) {
prompt("Output Link 1")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DLY2,DBF_DOUBLE) {
prompt("Delay 2")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DOL2,DBF_INLINK) {
prompt("Input link 2")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DO2,DBF_DOUBLE) {
prompt("Value 2")
interest(1)
}
field(LNK2,DBF_OUTLINK) {
prompt("Output Link 2")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DLY3,DBF_DOUBLE) {
prompt("Delay 3")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DOL3,DBF_INLINK) {
prompt("Input link 3")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DO3,DBF_DOUBLE) {
prompt("Value 3")
interest(1)
}
field(LNK3,DBF_OUTLINK) {
prompt("Output Link 3")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DLY4,DBF_DOUBLE) {
prompt("Delay 4")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DOL4,DBF_INLINK) {
prompt("Input link 4")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DO4,DBF_DOUBLE) {
prompt("Value 4")
interest(1)
}
field(LNK4,DBF_OUTLINK) {
prompt("Output Link 4")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DLY5,DBF_DOUBLE) {
prompt("Delay 5")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DOL5,DBF_INLINK) {
prompt("Input link 5")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DO5,DBF_DOUBLE) {
prompt("Value 5")
interest(1)
}
field(LNK5,DBF_OUTLINK) {
prompt("Output Link 5")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DLY6,DBF_DOUBLE) {
prompt("Delay 6")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DOL6,DBF_INLINK) {
prompt("Input link 6")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DO6,DBF_DOUBLE) {
prompt("Value 6")
interest(1)
}
field(LNK6,DBF_OUTLINK) {
prompt("Output Link 6")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DLY7,DBF_DOUBLE) {
prompt("Delay 7")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DOL7,DBF_INLINK) {
prompt("Input link 7")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DO7,DBF_DOUBLE) {
prompt("Value 7")
interest(1)
}
field(LNK7,DBF_OUTLINK) {
prompt("Output Link 7")
promptgroup("41 - Link 0-7")
interest(1)
}
field(DLY8,DBF_DOUBLE) {
prompt("Delay 8")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOL8,DBF_INLINK) {
prompt("Input link 8")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DO8,DBF_DOUBLE) {
prompt("Value 8")
interest(1)
}
field(LNK8,DBF_OUTLINK) {
prompt("Output Link 8")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DLY9,DBF_DOUBLE) {
prompt("Delay 9")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOL9,DBF_INLINK) {
prompt("Input link 9")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DO9,DBF_DOUBLE) {
prompt("Value 9")
interest(1)
}
field(LNK9,DBF_OUTLINK) {
prompt("Output Link 9")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DLYA,DBF_DOUBLE) {
prompt("Delay 10")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOLA,DBF_INLINK) {
prompt("Input link 10")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOA,DBF_DOUBLE) {
prompt("Value 10")
interest(1)
}
field(LNKA,DBF_OUTLINK) {
prompt("Output Link 10")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DLYB,DBF_DOUBLE) {
prompt("Delay 11")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOLB,DBF_INLINK) {
prompt("Input link 11")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOB,DBF_DOUBLE) {
prompt("Value 11")
interest(1)
}
field(LNKB,DBF_OUTLINK) {
prompt("Output Link 11")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DLYC,DBF_DOUBLE) {
prompt("Delay 12")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOLC,DBF_INLINK) {
prompt("Input link 12")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOC,DBF_DOUBLE) {
prompt("Value 12")
interest(1)
}
field(LNKC,DBF_OUTLINK) {
prompt("Output Link 12")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DLYD,DBF_DOUBLE) {
prompt("Delay 13")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOLD,DBF_INLINK) {
prompt("Input link 13")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOD,DBF_DOUBLE) {
prompt("Value 13")
interest(1)
}
field(LNKD,DBF_OUTLINK) {
prompt("Output Link 13")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DLYE,DBF_DOUBLE) {
prompt("Delay 14")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOLE,DBF_INLINK) {
prompt("Input link 14")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOE,DBF_DOUBLE) {
prompt("Value 14")
interest(1)
}
field(LNKE,DBF_OUTLINK) {
prompt("Output Link 14")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DLYF,DBF_DOUBLE) {
prompt("Delay 15")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOLF,DBF_INLINK) {
prompt("Input link 15")
promptgroup("42 - Link 8-F")
interest(1)
}
field(DOF,DBF_DOUBLE) {
prompt("Value 15")
interest(1)
}
field(LNKF,DBF_OUTLINK) {
prompt("Output Link 15")
promptgroup("42 - Link 8-F")
interest(1)
}
}
variable(seqDLYprecision, int)
variable(seqDLYlimit, double)

View File

@@ -219,9 +219,9 @@ static long readValue(stringinRecord *prec)
}
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -93,6 +93,6 @@ recordtype(stringin) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
}

View File

@@ -247,9 +247,9 @@ static long writeValue(stringoutRecord *prec)
status = dbPutLink(&prec->siol, DBR_STRING, &prec->val, 1);
prec->pact = FALSE;
} else { /* !prec->pact && delay >= 0. */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) {
pvt = calloc(1, sizeof(CALLBACK)); /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(epicsCallback)); /* very lazy allocation of callback structure */
prec->simpvt = pvt;
}
if (pvt) callbackRequestProcessCallbackDelayed(pvt, prec->prio, prec, prec->sdly);

View File

@@ -99,7 +99,7 @@ recordtype(stringout) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
field(IVOA,DBF_MENU) {
prompt("INVALID output action")

View File

@@ -1,90 +0,0 @@
#*************************************************************************
# Copyright (c) 2002 The University of Chicago, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE is distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
recordtype(subArray) {
include "dbCommon.dbd"
field(VAL,DBF_NOACCESS) {
prompt("Value")
asl(ASL0)
special(SPC_DBADDR)
pp(TRUE)
extra("void * val")
#=type Set by FTVL
#=read Yes
#=write Yes
}
field(PREC,DBF_SHORT) {
prompt("Display Precision")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(FTVL,DBF_MENU) {
prompt("Field Type of Value")
promptgroup("30 - Action")
special(SPC_NOMOD)
interest(1)
menu(menuFtype)
}
field(INP,DBF_INLINK) {
prompt("Input Specification")
promptgroup("40 - Input")
interest(1)
}
field(EGU,DBF_STRING) {
prompt("Engineering Units")
promptgroup("80 - Display")
interest(1)
size(16)
prop(YES)
}
field(HOPR,DBF_DOUBLE) {
prompt("High Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(LOPR,DBF_DOUBLE) {
prompt("Low Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(MALM,DBF_ULONG) {
prompt("Maximum Elements")
promptgroup("30 - Action")
special(SPC_NOMOD)
interest(1)
initial("1")
}
field(NELM,DBF_ULONG) {
prompt("Number of Elements")
promptgroup("30 - Action")
pp(TRUE)
initial("1")
}
field(INDX,DBF_ULONG) {
prompt("Substring Index")
promptgroup("30 - Action")
pp(TRUE)
}
field(BUSY,DBF_SHORT) {
prompt("Busy Indicator")
special(SPC_NOMOD)
}
field(NORD,DBF_LONG) {
prompt("Number elements read")
special(SPC_NOMOD)
}
field(BPTR,DBF_NOACCESS) {
prompt("Buffer Pointer")
special(SPC_NOMOD)
interest(4)
extra("void * bptr")
}
}

View File

@@ -0,0 +1,455 @@
#*************************************************************************
# Copyright (c) 2002 The University of Chicago, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE is distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
=head1 Sub-Array Record (subArray)
The normal use for the subArray record type is to obtain sub-arrays from
waveform records. Setting either the number of elements (NELM) or index (INDX)
fields causes the record to be processed anew so that applications in which the
length and position of a sub-array in a waveform record vary dynamically can be
implemented using standard EPICS operator interface tools.
The first element of the sub-array, that at location INDX in the referenced
waveform record, can be displayed as a scalar, or the entire subarray (of length
NELM) can be displayed in the same way as a waveform record. If there are fewer
than NELM elements in the referenced waveform after the INDX, only the number of
elements actually available are returned, and the number of elements read field
(NORD) is set to reflect this. This record type does not support writing new
values into waveform records.
=head2 Contents
=over
=item * L<Parameter Fields>
=over
=item * L<Scan Parameters>
=item * L<Read Parameters>
=item * L<Array Parameters>
=item * L<Operator Display Parameters>
=item * L<Alarm Parameters>
=item * L<Run-time Parameters>
=back
=item * L<Record Support>
=over
=item * L<Record Support Routines (subArrayRecord.c)>
=item * L<Record Processing>
=item * L<Example Synchronous Subroutine>
=item * L<Example Asynchronous Subroutine>
=back
=item * L<Device Support>
=over
=item * L<Fields Of Interest To Device Support>
=item * L<Device Support Routines (devSASoft.c)>
=item * L<Device Support For Soft Records>
=back
=back
=begin html
<br>
<hr>
<br>
=end html
=recordtype subArray
=cut
recordtype(subArray) {
=head2 Parameter Fields
=head3 Scan Parameters
The subArray record has the standard fields for specifying under what
circumstances the record will be processed. These fields are listed in
L<Scan Fields>.
In addition,
L<Scanning Specification>
explains how these fields are used.
=head3 Read Parameters
The subArray's input link (INP) should be configured to reference the Waveform
record. It should specify the VAL field of a Waveform record. The INP field can
be a channel access link, in addition to a database link. See
L<Address Specification>
for information on specifying links.
In addition, the DTYP field must specify a device support module. Currently, the
only device support module is C<<< Soft Channel >>>.
=fields INP, DTYP
=head3 Array Parameters
These parameters determine the number of array elements (the array length) and
the data type of those elements. The Field Type of Value (FTVL) field determines
the data type of the array.
The user specifies the maximum number of elements allowed in the subarray in the
MALM field. Generally, the number should be equal to the number of elements of
the Waveform array (found in the Waveform's NELM field). The MALM field is used
to allocate memory. The subArray's Number of Elements (NELM) field is where the
user specifies the actual number of elements that the subArray will contain. It
should of course be no greater than MALM; if it is, the record processing
routine sets it equal to MALM.
The INDX field determines the offset of the subArray record's array in relation
to the Waveform's. For instance, if INDX is 2, then the subArray will read NELM
elements starting with the third element of the Waveform's array. Thus, it
equals the index number of the Waveform's array.
The actual sub-array is referenced by the VAL field.
=fields FTVL, VAL, MALM, NELM, INDX
=head3 Operator Display Parameters
These parameters are used to present meaningful data to the operator. They
display the value and other parameters of the subarray record either textually
or graphically.
EGU is a string of up to 16 characters describing the engineering units (if any)
of the values which the subArray holds. It is retrieved by the C<<< get_units
>>> record support routine.
The HOPR and LOPR fields set the upper and lower display limits for the
sub-array elements. Both the C<<< get_graphic_double >>> and C<<<
get_control_double >>> record support routines retrieve these fields.
The PREC field determines the floating point precision with which to display
VAL. It is used whenever the C<<< get_precision >>> record support routine is
called.
See L<Fields Common to All Record Types>
for more on the record name (NAME) and description (DESC) fields.
=fields EGU, HOPR, LOPR, PREC, NAME, DESC
=head3 Alarm Parameters
The subarray record has the alarm parameters common to all record types.
L<Alarm Fields> lists other fields related to a alarms that are common to all
record types.
=head3 Run-time Parameters
These fields are not configurable by the user. They are used for the record's
internal processing or to represent the current state of the record.
The NORD field holds a counter of the number of elements read into the array. It
can be less than NELM even after the array is full if NELM exceeds the number of
existing elements in the referenced array, i.e., the Waveform's array.
BPTR contains a pointer to the record's array.
=fields NORD, BPTR
=begin html
<br>
<hr>
<br>
=end html
=head2 Record Support
=head3 Record Support Routines (subArrayRecord.c)
=head4 init_record
long (*init_record)(struct dbCommon *precord, int pass)
Using MALM and FTVL, space for the array is allocated. The array address is
stored in BPTR. This routine checks to see that device support is available and
a device support read routine is defined. If either does not exist, an error
message is issued and processing is terminated. If device support includes
C<init_record()>, it is called.
=head4 process
long (*process)(struct dbCommon *precord)
See L<Record Processing>.
=head4 cvt_dbaddr
long (*cvt_dbaddr)(struct dbAddr *paddr)
This is called by dbNameToAddr. It makes the dbAddr structure refer to the
actual buffer holding the result.
=head4 get_array_info
long (*get_array_info)(struct dbAddr *paddr, long *no_elements, long *offset)
Retrieves NELM.
=head4 put_array_info
long (*put_array_info)(struct dbAddr *paddr, long nNew)
Sets NORD.
=head4 get_graphic_double
long (*get_graphic_double)(struct dbAddr *paddr, struct dbr_grDouble *p)
For the elements in the array, this routine routines HOPR and LOPR. For the INDX
field, this routine returns MALM - 1 and 0. For NELM, it returns MALM and 1. For
other fields, it calls C<<< recGblGetGraphicDouble() >>>.
=head4 get_control_double
long (*get_control_double)(struct dbAddr *paddr, struct dbr_ctrlDouble *p)
For array elements, this routine retrieves HOPR and LOPR. Otherwise, C<<<
recGblGetControlDouble() >>> is called.
=head4 get_units
long (*get_units)(struct dbAddr *paddr, char *units)
Retrieves EGU.
=head4 get_precision
long (*get_precision)(const struct dbAddr *paddr, long *precision)
Retrieves PREC.
=head3 Record Processing
Routine process implements the following algorithm:
=over
=item 1.
Check to see that the appropriate device support module exists. If it doesn't,
an error message is issued and processing is terminated with the PACT field
still set to TRUE. This ensures that processes will no longer be called for this
record. Thus error storms will not occur.
=item 2.
Sanity check NELM and INDX. If NELM is greater than MALM it is set to MALM. If
INDX is greater than or equal to MALM it is set to MALM-1.
=item 3.
Call device support read routine. This routine is expected to place the desired
sub-array at the beginning of the buffer and set NORD to the number of elements
of the sub-array that were read.
=item 4.
If PACT has been changed to TRUE, the device support read routine has started
but has not completed writing the new value. In this case, the processing
routine merely returns, leaving PACT TRUE. Otherwise, process sets PACT TRUE at
this time. This asynchronous processing logic is not currently used but has been
left in place.
=item 5.
Check to see if monitors should be invoked.
=over
=item *
Alarm monitors are invoked if the alarm status or severity has changed.
=item *
Archive and value change monitors are always invoked.
=item *
NSEV and NSTA are reset to 0.
=back
=item 6.
Scan forward link if necessary, set PACT FALSE, and return.
=back
=begin html
<br>
<hr>
<br>
=end html
=head2 Device Support
=head3 Fields Of Interest To Device Support
The device support routines are primarily interested in the following fields:
=fields PACT, DPVT, UDF, NSEV, NSTA, INP, FTVL, MALM, NELM, INDX, BPTR, NORD
=head3 Device Support Routines (devSASoft.c)
Device support consists of the following routines:
=head4 long report(int level)
This optional routine is called by the IOC command C<dbior> and is passed the
report level that was requested by the user.
It should print a report on the state of the device support to stdout.
The C<level> parameter may be used to output increasingly more detailed
information at higher levels, or to select different types of information with
different levels.
Level zero should print no more than a small summary.
=head4 long init(int after)
This optional routine is called twice at IOC initialization time.
The first call happens before any of the C<init_record()> calls are made, with
the integer parameter C<after> set to 0.
The second call happens after all of the C<init_record()> calls have been made,
with C<after> set to 1.
=head4 init_record
long init_record(subArrayRecord *prec)
This routine is called by the record support C<init_record()> routine.
=head4 read_sa
long read_sa(subArrayRecord *prec)
Enough of the source waveform is read into BPTR, from the beginning of the
source, to include the requested sub-array. The sub-array is then copied to the
beginning of the buffer. NORD is set to indicate how many elements of the
sub-array were acquired.
=head3 Device Support For Soft Records
Only the device support module C<<< Soft Channel >>> is currently provided. The
INP link type must be either DB_LINK or CA_LINK.
=head4 Soft Channel
INP is expected to point to a waveform record.
=cut
include "dbCommon.dbd"
field(VAL,DBF_NOACCESS) {
prompt("Value")
asl(ASL0)
special(SPC_DBADDR)
pp(TRUE)
extra("void * val")
#=type Set by FTVL
#=read Yes
#=write Yes
}
field(PREC,DBF_SHORT) {
prompt("Display Precision")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(FTVL,DBF_MENU) {
prompt("Field Type of Value")
promptgroup("30 - Action")
special(SPC_NOMOD)
interest(1)
menu(menuFtype)
}
field(INP,DBF_INLINK) {
prompt("Input Specification")
promptgroup("40 - Input")
interest(1)
}
field(EGU,DBF_STRING) {
prompt("Engineering Units")
promptgroup("80 - Display")
interest(1)
size(16)
prop(YES)
}
field(HOPR,DBF_DOUBLE) {
prompt("High Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(LOPR,DBF_DOUBLE) {
prompt("Low Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(MALM,DBF_ULONG) {
prompt("Maximum Elements")
promptgroup("30 - Action")
special(SPC_NOMOD)
interest(1)
initial("1")
}
field(NELM,DBF_ULONG) {
prompt("Number of Elements")
promptgroup("30 - Action")
pp(TRUE)
initial("1")
}
field(INDX,DBF_ULONG) {
prompt("Substring Index")
promptgroup("30 - Action")
pp(TRUE)
}
field(BUSY,DBF_SHORT) {
prompt("Busy Indicator")
special(SPC_NOMOD)
}
field(NORD,DBF_LONG) {
prompt("Number elements read")
special(SPC_NOMOD)
}
field(BPTR,DBF_NOACCESS) {
prompt("Buffer Pointer")
special(SPC_NOMOD)
interest(4)
extra("void * bptr")
}
}

View File

@@ -1,328 +0,0 @@
#*************************************************************************
# Copyright (c) 2008 UChicago Argonne LLC, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE is distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
recordtype(sub) {
include "dbCommon.dbd"
field(VAL,DBF_DOUBLE) {
prompt("Result")
asl(ASL0)
pp(TRUE)
}
field(INAM,DBF_STRING) {
prompt("Init Routine Name")
promptgroup("30 - Action")
special(SPC_NOMOD)
interest(1)
size(40)
}
field(SNAM,DBF_STRING) {
prompt("Subroutine Name")
promptgroup("30 - Action")
special(SPC_MOD)
interest(1)
size(40)
}
%struct subRecord;
%typedef long (*SUBFUNCPTR)(struct subRecord *);
field(SADR,DBF_NOACCESS) {
prompt("Subroutine Address")
special(SPC_NOMOD)
interest(4)
extra("SUBFUNCPTR sadr")
}
field(INPA,DBF_INLINK) {
prompt("Input A")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPB,DBF_INLINK) {
prompt("Input B")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPC,DBF_INLINK) {
prompt("Input C")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPD,DBF_INLINK) {
prompt("Input D")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPE,DBF_INLINK) {
prompt("Input E")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPF,DBF_INLINK) {
prompt("Input F")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPG,DBF_INLINK) {
prompt("Input G")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPH,DBF_INLINK) {
prompt("Input H")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPI,DBF_INLINK) {
prompt("Input I")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPJ,DBF_INLINK) {
prompt("Input J")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPK,DBF_INLINK) {
prompt("Input K")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPL,DBF_INLINK) {
prompt("Input L")
promptgroup("42 - Input G-L")
interest(1)
}
field(EGU,DBF_STRING) {
prompt("Engineering Units")
promptgroup("80 - Display")
interest(1)
size(16)
prop(YES)
}
field(HOPR,DBF_DOUBLE) {
prompt("High Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(LOPR,DBF_DOUBLE) {
prompt("Low Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(HIHI,DBF_DOUBLE) {
prompt("Hihi Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(LOLO,DBF_DOUBLE) {
prompt("Lolo Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(HIGH,DBF_DOUBLE) {
prompt("High Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(LOW,DBF_DOUBLE) {
prompt("Low Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(PREC,DBF_SHORT) {
prompt("Display Precision")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(BRSV,DBF_MENU) {
prompt("Bad Return Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(HHSV,DBF_MENU) {
prompt("Hihi Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
menu(menuAlarmSevr)
}
field(LLSV,DBF_MENU) {
prompt("Lolo Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
menu(menuAlarmSevr)
}
field(HSV,DBF_MENU) {
prompt("High Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
menu(menuAlarmSevr)
}
field(LSV,DBF_MENU) {
prompt("Low Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
menu(menuAlarmSevr)
}
field(HYST,DBF_DOUBLE) {
prompt("Alarm Deadband")
promptgroup("70 - Alarm")
interest(1)
}
field(ADEL,DBF_DOUBLE) {
prompt("Archive Deadband")
promptgroup("80 - Display")
interest(1)
}
field(MDEL,DBF_DOUBLE) {
prompt("Monitor Deadband")
promptgroup("80 - Display")
interest(1)
}
field(A,DBF_DOUBLE) {
prompt("Value of Input A")
pp(TRUE)
}
field(B,DBF_DOUBLE) {
prompt("Value of Input B")
pp(TRUE)
}
field(C,DBF_DOUBLE) {
prompt("Value of Input C")
pp(TRUE)
}
field(D,DBF_DOUBLE) {
prompt("Value of Input D")
pp(TRUE)
}
field(E,DBF_DOUBLE) {
prompt("Value of Input E")
pp(TRUE)
}
field(F,DBF_DOUBLE) {
prompt("Value of Input F")
pp(TRUE)
}
field(G,DBF_DOUBLE) {
prompt("Value of Input G")
pp(TRUE)
}
field(H,DBF_DOUBLE) {
prompt("Value of Input H")
pp(TRUE)
}
field(I,DBF_DOUBLE) {
prompt("Value of Input I")
pp(TRUE)
}
field(J,DBF_DOUBLE) {
prompt("Value of Input J")
pp(TRUE)
}
field(K,DBF_DOUBLE) {
prompt("Value of Input K")
pp(TRUE)
}
field(L,DBF_DOUBLE) {
prompt("Value of Input L")
pp(TRUE)
}
field(LA,DBF_DOUBLE) {
prompt("Prev Value of A")
special(SPC_NOMOD)
interest(3)
}
field(LB,DBF_DOUBLE) {
prompt("Prev Value of B")
special(SPC_NOMOD)
interest(3)
}
field(LC,DBF_DOUBLE) {
prompt("Prev Value of C")
special(SPC_NOMOD)
interest(3)
}
field(LD,DBF_DOUBLE) {
prompt("Prev Value of D")
special(SPC_NOMOD)
interest(3)
}
field(LE,DBF_DOUBLE) {
prompt("Prev Value of E")
special(SPC_NOMOD)
interest(3)
}
field(LF,DBF_DOUBLE) {
prompt("Prev Value of F")
special(SPC_NOMOD)
interest(3)
}
field(LG,DBF_DOUBLE) {
prompt("Prev Value of G")
special(SPC_NOMOD)
interest(3)
}
field(LH,DBF_DOUBLE) {
prompt("Prev Value of H")
special(SPC_NOMOD)
interest(3)
}
field(LI,DBF_DOUBLE) {
prompt("Prev Value of I")
special(SPC_NOMOD)
interest(3)
}
field(LJ,DBF_DOUBLE) {
prompt("Prev Value of J")
special(SPC_NOMOD)
interest(3)
}
field(LK,DBF_DOUBLE) {
prompt("Prev Value of K")
special(SPC_NOMOD)
interest(3)
}
field(LL,DBF_DOUBLE) {
prompt("Prev Value of L")
special(SPC_NOMOD)
interest(3)
}
field(LALM,DBF_DOUBLE) {
prompt("Last Value Alarmed")
special(SPC_NOMOD)
interest(3)
}
field(ALST,DBF_DOUBLE) {
prompt("Last Value Archived")
special(SPC_NOMOD)
interest(3)
}
field(MLST,DBF_DOUBLE) {
prompt("Last Value Monitored")
special(SPC_NOMOD)
interest(3)
}
}

View File

@@ -0,0 +1,776 @@
#*************************************************************************
# Copyright (c) 2008 UChicago Argonne LLC, as Operator of Argonne
# National Laboratory.
# Copyright (c) 2002 The Regents of the University of California, as
# Operator of Los Alamos National Laboratory.
# EPICS BASE is distributed subject to a Software License Agreement found
# in file LICENSE that is included with this distribution.
#*************************************************************************
=head1 Subroutine Record (sub)
The subroutine record is used to call a C initialization routine and a recurring
scan routine. There is no device support for this record.
=head2 Contents
=over
=item * L<Parameter Fields>
=over
=item * L<Scan Parameters>
=item * L<Read Parameters>
=item * L<Subroutine Connection>
=item * L<Operator Display Parameters>
=item * L<Alarm Parameters>
=item * L<Monitor Parameters>
=item * L<Run-time Parameters>
=back
=item * L<Record Support>
=over
=item * L<Record Support Routines (subRecord.c)>
=item * L<Record Processing>
=item * L<Example Synchronous Subroutine>
=item * L<Example Asynchronous Subroutine>
=back
=back
=begin html
<br>
<hr>
<br>
=end html
=recordtype sub
=cut
recordtype(sub) {
=head2 Parameter Fields
=head3 Scan Parameters
The subroutine record has the standard fields for specifying under what
circumstances it will be processed. These fields are listed in
L<Scan Fields>. In addition, L<Scanning Specification>
explains how these fields are used.
=head3 Read Parameters
The subroutine record has twelve input links (INPA-INPL), each of which has a
corresponding value field (A-L). These fields are used to retrieve and store
values that can be passed to the subroutine that the record calls.
The input links can be either channel access or database links, or constants.
When constants, the corresponding value field for the link is initialized with
the constant value and the field's value can be changed at run-time via dbPuts.
Otherwise, the values for (A-F) are fetched from the input links when the record
is processed. See L<Address Specification> for information on specifying links.
=fields INPA, INPB, INPC, INPD, INPE, INPF, INPG, INPH, INPI, INPJ, INPK, INPL, A, B, C, D, E, F, G, H, I, J, K, L
=head3 Subroutine Connection
These fields are used to connect to the C subroutine. The name of the subroutine
should be entered in the SNAM field.
=fields INAM, SNAM
=head3 Operator Display Parameters
These parameters are used to present meaningful data to the operator. They
display the value and other parameters of the subroutine either textually or
graphically.
EGU is a string of up to 16 characters that could describe any units used by the
subroutine record. It is retrieved by the C<<< get_units >>> record support
routine.
The HOPR and LOPR fields set the upper and lower display limits for the VAL,
A-L, LA-LL, HIHI, LOLO, LOW, and HIGH fields. Both the C<<< get_graphic_double
>>> and C<<< get_control_double >>> record support routines retrieve these
fields.
The PREC field determines the floating point precision with which to display
VAL. It is used whenever the C<<< get_precision >>> record support routine is
called.
See L<Fields Common to All Record Types>
for more on the record name (NAME) and description (DESC) fields.
=fields EGU, HOPR, LOPR, PREC, NAME, DESC
=head3 Alarm Parameters
The possible alarm conditions for subroutine records are the SCAN, READ, limit
alarms, and an alarm that can be triggered if the subroutine returns a negative
value. The SCAN and READ alarms are called by the record or device support
routines. The limit alarms are configured by the user in the HIHI, LOLO, HIGH,
and LOW fields using numerical values. They apply to the VAL field. For each of
these fields, there is a corresponding severity field which can be either
NO_ALARM, MINOR, or MAJOR.
The BRSV field is where the user can set the alarm severity in case the
subroutine returns a negative value. See L<Alarm Specification>
for a complete explanation of alarms and these fields. L<Alarm Fields>
lists other fields related to a alarms that are common to all record types.
=fields HIHI, HIGH, LOW, LOLO, HHSV, HSV, LSV, LLSV, BRSV, HYST
=head3 Monitor Parameters
These parameters are used to determine when to send monitors placed on the VAL
field. The appropriate monitors are invoked when VAL differs from the values in
the ALST and MLST run-time fields, i.e., when the value of VAL changes by more
than the deadband specified in these fields. The ADEL and MDEL fields specify a
minimum delta which the change must surpass before the value-change monitors are
invoked. If these fields have a value of zero, everytime the value changes, a
monitor will be triggered; if they have a value of -1, everytime the record is
processed, monitors are triggered. The ADEL field is used by archive monitors
and the MDEL field for all other types of monitors. See L<Monitor Specification>
for a complete explanation of monitors and deadbands.
=fields ADEL, MDEL
=head3 Run-time Parameters
These parameters are used by the run-time code for processing the subroutine
record. They are not configured using a database configuration tool. They
represent the current state of the record. Many of them are used by the record
processing routines or the monitors.
VAL should be set by the subroutine. SADR holds the subroutine address and is
set by the record processing routine.
The rest of these fields--LALM, ALST, MLST, and the LA-LL fields--are used to
implement the monitors. For example, when LA is not equal to A, the value-change
monitors are called for that field.
=fields VAL, SADR, LALM, ALST, MLST, LA, LB, LC, LD, LE, LF, LG, LH, LI, LJ, LK, LL
=head2 Record Support
=head3 Record Support Routines (subRecord.c)
=head4 init_record
long (*init_record)(struct dbCommon *precord, int pass)
For each constant input link, the corresponding value field is initialized with
the constant value. For each input link that is of type PV_LINK, a channel
access link is created.
If an initialization subroutine is defined, it is located and called.
The processing subroutine is located and its address stored in SADR.
=head4 process
long (*process)(struct dbCommon *precord)
See L<Record Processing>.
=head4 get_units
long (*get_units)(struct dbAddr *paddr, char *units)
Retrieves EGU.
=head4 get_precision
long (*get_precision)(const struct dbAddr *paddr, long *precision)
Retrieves PREC when VAL is the field being referenced. Otherwise, calls C<<<
recGblGetPrec() >>>.
=head4 get_graphic_double
long (*get_graphic_double)(struct dbAddr *paddr, struct dbr_grDouble *p)
Sets the upper display and lower display limits for a field. If the field is
VAL, A-L, LA-LL, HIHI, HIGH, LOW, or LOLO, the limits are set to HOPR and LOPR,
else if the field has upper and lower limits defined they will be used, else the
upper and lower maximum values for the field type will be used.
=head4 get_control_double
long (*get_control_double)(struct dbAddr *paddr, struct dbr_ctrlDouble *p)
Sets the upper control and the lower control limits for a field. If the field is
VAL, A-L, LA-LL, HIHI, HIGH, LOW, or LOLO, the limits are set to HOPR and LOPR,
else if the field has upper and lower limits defined they will be used, else the
upper and lower maximum values for the field type will be used.
=head4 get_alarm_double
long (*get_alarm_double)(struct dbAddr *paddr, struct dbr_alDouble *p)
Sets the following values:
upper_alarm_limit = HIHI
upper_warning_limit = HIGH
lower_warning_limit = LOW
lower_alarm_limit = LOLO
=head3 Record Processing
Routine process implements the following algorithm:
=over
=item 1.
If PACT is FALSE then fetch all arguments.
=item 2.
Call the subroutine and check return value.
=over
=item *
Call subroutine
=item *
Set PACT TRUE
=item *
If return value is 1, return
=back
=item 3.
Check alarms. This routine checks to see if the new VAL causes the alarm status and severity to change. If so, NSEV, NSTA and LALM are set. It also honors the alarm hysteresis factor (HYST). Thus the value must change by more than HYST before the alarm status and severity is lowered.
=item 4.
Check to see if monitors should be invoked.
=over
=item *
Alarm monitors are invoked if the alarm status or severity has changed.
=item *
Archive and value change monitors are invoked if ADEL and MDEL conditions are
met.
=item *
Monitors for A-L are invoked if value has changed.
=item *
NSEV and NSTA are reset to 0.
=back
=item 5.
Scan forward link if necessary, set PACT FALSE, and return.
=back
=head3 Example Synchronous Subroutine
This is an example subroutine that merely increments VAL each time process is
called.
#include <stdio.h>
#include <dbDefs.h>
#include <subRecord.h>
#include <registryFunction.h>
#include <epicsExport.h>
static long subInit(struct subRecord *psub)
{
printf("subInit was called\n");
return 0;
}
static long subProcess(struct subRecord *psub)
{
psub->val++;
return 0;
}
epicsRegisterFunction(subInit);
epicsRegisterFunction(subProcess);
=head3 Example Asynchronous Subroutine
This example for a VxWorks IOC shows an asynchronous subroutine. It uses
(actually misuses) fields A and B. Field A is taken as the number of seconds
until asynchronous completion. Field B is a flag to decide if messages should be
printed. Lets assume A E<gt> 0 and B = 1. The following sequence of actions will
occcur:
=over
=item 1.
subProcess is called with pact FALSE. It performs the following steps.
=over
=item *
Computes, from A, the number of ticks until asynchronous completion should
occur.
=item *
Prints a message stating that it is requesting an asynchronous callback.
=item *
Calls the vxWorks watchdog start routine.
=item *
Sets pact TRUE and returns a value of 0. This tells record support to complete
without checking alarms, monitors, or the forward link.
=back
=item 2.
When the time expires, the system wide callback task calls myCallback.
myCallback locks the record, calls process, and unlocks the record.
=item 3.
Process again calls subProcess, but now pact is TRUE. Thus the following is
done:
=over
=item *
VAL is incremented.
=item *
A completion message is printed.
=item *
subProcess returns 0. The record processing routine will complete record
processing.
=back
=back
#include <types.h>
#include <stdio.h>
#include <wdLib.h>
#include <callback.h>
#include <dbDefs.h>
#include <dbAccess.h>
#include <subRecord.h>
/* control block for callback*/
struct callback {
epicsCallback callback;
struct dbCommon *precord;
WDOG_ID wd_id;
};
void myCallback(struct callback *pcallback)
{
struct dbCommon *precord=pcallback->precord;
struct rset *prset=(struct rset *)(precord->rset);
dbScanLock(precord);
(*prset->process)(precord);
dbScanUnlock(precord);
}
long subInit(struct subRecord *psub)
{
struct callback *pcallback;
pcallback = (struct callback *)(calloc(1,sizeof(struct callback)));
psub->dpvt = (void *)pcallback;
callbackSetCallback(myCallback,pcallback);
pcallback->precord = (struct dbCommon *)psub;
pcallback->wd_id = wdCreate();
printf("subInit was called\n");
return 0;
}
long subProcess(struct subRecord *psub)
{
struct callback *pcallback=(struct callback *)(psub->dpvt);
/* sub.inp must be a CONSTANT*/
if (psub->pact) {
psub->val++;
if (psub->b)
printf("%s subProcess Completed\n", psub->name);
return 0;
} else {
int wait_time = (long)(psub->a * vxTicksPerSecond);
if (wait_time <= 0){
if (psub->b)
printf("%s subProcess sync processing\n", psub->name);
psub->pact = TRUE;
return 0;
}
if (psub->b){
callbackSetPriority(psub->prio, pcallback);
printf("%s Starting async processing\n", psub->name);
wdStart(pcallback->wd_id, wait_time, callbackRequest, (int)pcallback);
return 1;
}
}
return 0;
}
=cut
include "dbCommon.dbd"
field(VAL,DBF_DOUBLE) {
prompt("Result")
asl(ASL0)
pp(TRUE)
}
field(INAM,DBF_STRING) {
prompt("Init Routine Name")
promptgroup("30 - Action")
special(SPC_NOMOD)
interest(1)
size(40)
}
field(SNAM,DBF_STRING) {
prompt("Subroutine Name")
promptgroup("30 - Action")
special(SPC_MOD)
interest(1)
size(40)
}
%struct subRecord;
%typedef long (*SUBFUNCPTR)(struct subRecord *);
field(SADR,DBF_NOACCESS) {
prompt("Subroutine Address")
special(SPC_NOMOD)
interest(4)
extra("SUBFUNCPTR sadr")
}
field(INPA,DBF_INLINK) {
prompt("Input A")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPB,DBF_INLINK) {
prompt("Input B")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPC,DBF_INLINK) {
prompt("Input C")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPD,DBF_INLINK) {
prompt("Input D")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPE,DBF_INLINK) {
prompt("Input E")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPF,DBF_INLINK) {
prompt("Input F")
promptgroup("41 - Input A-F")
interest(1)
}
field(INPG,DBF_INLINK) {
prompt("Input G")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPH,DBF_INLINK) {
prompt("Input H")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPI,DBF_INLINK) {
prompt("Input I")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPJ,DBF_INLINK) {
prompt("Input J")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPK,DBF_INLINK) {
prompt("Input K")
promptgroup("42 - Input G-L")
interest(1)
}
field(INPL,DBF_INLINK) {
prompt("Input L")
promptgroup("42 - Input G-L")
interest(1)
}
field(EGU,DBF_STRING) {
prompt("Engineering Units")
promptgroup("80 - Display")
interest(1)
size(16)
prop(YES)
}
field(HOPR,DBF_DOUBLE) {
prompt("High Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(LOPR,DBF_DOUBLE) {
prompt("Low Operating Range")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(HIHI,DBF_DOUBLE) {
prompt("Hihi Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(LOLO,DBF_DOUBLE) {
prompt("Lolo Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(HIGH,DBF_DOUBLE) {
prompt("High Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(LOW,DBF_DOUBLE) {
prompt("Low Alarm Limit")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
}
field(PREC,DBF_SHORT) {
prompt("Display Precision")
promptgroup("80 - Display")
interest(1)
prop(YES)
}
field(BRSV,DBF_MENU) {
prompt("Bad Return Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
menu(menuAlarmSevr)
}
field(HHSV,DBF_MENU) {
prompt("Hihi Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
menu(menuAlarmSevr)
}
field(LLSV,DBF_MENU) {
prompt("Lolo Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
menu(menuAlarmSevr)
}
field(HSV,DBF_MENU) {
prompt("High Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
menu(menuAlarmSevr)
}
field(LSV,DBF_MENU) {
prompt("Low Severity")
promptgroup("70 - Alarm")
pp(TRUE)
interest(1)
prop(YES)
menu(menuAlarmSevr)
}
field(HYST,DBF_DOUBLE) {
prompt("Alarm Deadband")
promptgroup("70 - Alarm")
interest(1)
}
field(ADEL,DBF_DOUBLE) {
prompt("Archive Deadband")
promptgroup("80 - Display")
interest(1)
}
field(MDEL,DBF_DOUBLE) {
prompt("Monitor Deadband")
promptgroup("80 - Display")
interest(1)
}
field(A,DBF_DOUBLE) {
prompt("Value of Input A")
pp(TRUE)
}
field(B,DBF_DOUBLE) {
prompt("Value of Input B")
pp(TRUE)
}
field(C,DBF_DOUBLE) {
prompt("Value of Input C")
pp(TRUE)
}
field(D,DBF_DOUBLE) {
prompt("Value of Input D")
pp(TRUE)
}
field(E,DBF_DOUBLE) {
prompt("Value of Input E")
pp(TRUE)
}
field(F,DBF_DOUBLE) {
prompt("Value of Input F")
pp(TRUE)
}
field(G,DBF_DOUBLE) {
prompt("Value of Input G")
pp(TRUE)
}
field(H,DBF_DOUBLE) {
prompt("Value of Input H")
pp(TRUE)
}
field(I,DBF_DOUBLE) {
prompt("Value of Input I")
pp(TRUE)
}
field(J,DBF_DOUBLE) {
prompt("Value of Input J")
pp(TRUE)
}
field(K,DBF_DOUBLE) {
prompt("Value of Input K")
pp(TRUE)
}
field(L,DBF_DOUBLE) {
prompt("Value of Input L")
pp(TRUE)
}
field(LA,DBF_DOUBLE) {
prompt("Prev Value of A")
special(SPC_NOMOD)
interest(3)
}
field(LB,DBF_DOUBLE) {
prompt("Prev Value of B")
special(SPC_NOMOD)
interest(3)
}
field(LC,DBF_DOUBLE) {
prompt("Prev Value of C")
special(SPC_NOMOD)
interest(3)
}
field(LD,DBF_DOUBLE) {
prompt("Prev Value of D")
special(SPC_NOMOD)
interest(3)
}
field(LE,DBF_DOUBLE) {
prompt("Prev Value of E")
special(SPC_NOMOD)
interest(3)
}
field(LF,DBF_DOUBLE) {
prompt("Prev Value of F")
special(SPC_NOMOD)
interest(3)
}
field(LG,DBF_DOUBLE) {
prompt("Prev Value of G")
special(SPC_NOMOD)
interest(3)
}
field(LH,DBF_DOUBLE) {
prompt("Prev Value of H")
special(SPC_NOMOD)
interest(3)
}
field(LI,DBF_DOUBLE) {
prompt("Prev Value of I")
special(SPC_NOMOD)
interest(3)
}
field(LJ,DBF_DOUBLE) {
prompt("Prev Value of J")
special(SPC_NOMOD)
interest(3)
}
field(LK,DBF_DOUBLE) {
prompt("Prev Value of K")
special(SPC_NOMOD)
interest(3)
}
field(LL,DBF_DOUBLE) {
prompt("Prev Value of L")
special(SPC_NOMOD)
interest(3)
}
field(LALM,DBF_DOUBLE) {
prompt("Last Value Alarmed")
special(SPC_NOMOD)
interest(3)
}
field(ALST,DBF_DOUBLE) {
prompt("Last Value Archived")
special(SPC_NOMOD)
interest(3)
}
field(MLST,DBF_DOUBLE) {
prompt("Last Value Monitored")
special(SPC_NOMOD)
interest(3)
}
}

View File

@@ -364,10 +364,10 @@ static long readValue(waveformRecord *prec)
prec->pact = FALSE;
}
else { /* !prec->pact && delay >= 0 */
CALLBACK *pvt = prec->simpvt;
epicsCallback *pvt = prec->simpvt;
if (!pvt) { /* very lazy allocation of callback structure */
pvt = calloc(1, sizeof(CALLBACK));
pvt = calloc(1, sizeof(epicsCallback));
prec->simpvt = pvt;
}
if (pvt)

View File

@@ -9,29 +9,16 @@
=title Waveform Record (waveform)
...
=head2 Record-specific Menus
=head3 Menu waveformPOST
The MPST and APST fields use this menu to determine when to post new value
and archive monitors respectively.
=menu waveformPOST
...
=head2 Parameter Fields
The record-specific fields are described below.
The waveform record type is used to interface waveform digitizers. The record
stores its data in arrays. The array can contain any of the supported data
types.
=recordtype waveform
...
=cut
include "menuFtype.dbd"
menu(waveformPOST) {
choice(waveformPOST_Always,"Always")
choice(waveformPOST_OnChange,"On Change")
@@ -39,7 +26,435 @@ menu(waveformPOST) {
recordtype(waveform) {
=fields VAL, FTVL, MPST, APST
=pod
=head1 Contents
=over
=item * L<Parameter Fields>
=over
=item * L<Scan Parameters>
=item * L<Read Parameters>
=item * L<Operator Display Parameters>
=item * L<Run-time Parameters>
=back
=item * L<Record Support>
=over
=item * L<Record Support Routines>
=item * L<Record Processing>
=back
=item * L<Device Support>
=over
=item * L<Fields Of Interest To Device Support>
=item * L<Device Support Routines>
=item * L<Device Support For Soft Records>
=back
=back
=begin html
<hr>
=end html
=head2 Parameter Fields
The waveform's fields fall into the following categories:
=over
=item * L<Scan Parameters>;
=item * L<Read Parameters>;
=item * L<Operator Display Parameters>;
=item * L<Run-time Parameters>;
=back
=head3 Scan Parameters
The waveform record has the standard fields for specifying under what
circumstances the record will be processed. These fields are listed in L<Scan
Fields>. In addition, L<Scanning Specification> explains how these fields are
used. Note that I/O event scanning is only supported for those card types that
interrupt.
=head3 Read Parameters
These fields are configurable by the user to specify how and from where the
record reads its data. How the INP field is configured determines where the
waveform gets its input. It can be a hardware address, a channel access or
database link, or a constant. Only in records that use soft device support can
the INP field be a channel access link, a database link, or a constant.
Otherwise, the INP field must be a hardware address. See L<Address
Specification> for information on the format of hardware addresses and database
links.
=head4 Fields related to waveform reading
=fields DTYP, INP, NELM, FTVL, RARM
The DTYP field must contain the name of the appropriate device support module.
The values retrieved from the input link are placed in an array referenced by
VAL. (If the INP link is a constant, elements can be placed in the array via
dbPuts.) NELM specifies the number of elements that the array will hold, while
FTVL specifies the data type of the elements.
The RARM field causes the device to re-arm when this field is set to 1.
=head4 Possible data types for FTVL
=menu menuFtype
=head3 Operator Display Parameters
These parameters are used to present meaningful data to the operator. They
display the value and other parameters of the waveform either textually or
graphically.
=head4 Fields related to I<Operator Display>
=fields EGU, HOPR, LOPR, PREC, NAME, DESC
EGU is a string of up to 16 characters describing the units that the waveform
measures. It is retrieved by the C<<< get_units >>> record support routine.
The HOPR and LOPR fields set the upper and lower display limits for array
elements referenced by the VAL field. Both the C<<< get_graphic_double >>> and
C<<< get_control_double >>> record support routines retrieve these fields.
The PREC field determines the floating point precision with which to display the
array values. It is used whenever the C<<< get_precision >>> record support
routine is called.
See L<Fields Common to All Record Types> for more on the record name (NAME) and
description (DESC) fields.
=head3 Alarm Parameters
The waveform record has the alarm parameters common to all record types. L<Alarm
Fields> lists other fields related to a alarms that are common to all record
types.
=head3 Monitor Parameters
These parameters are used to determine when to send monitors placed on the VAL
field. The APST and MPST fields are a menu with choices "Always" and "On
Change". The default is "Always", thus monitors will normally be sent every time
the record processes. Selecting "On Change" causes a 32-bit hash of the VAL
field buffer to be calculated and compared with the previous hash value every
time the record processes; the monitor will only be sent if the hash is
different, indicating that the buffer has changed. Note that there is a small
chance that two different value buffers might result in the same hash value, so
for critical systems "Always" may be a better choice, even though it re-sends
duplicate data.
=head4 Record fields related to I<Monitor Parameters>
=fields APST, MPST, HASH
=head4 Menu choices for C<APST> and C<MPST> fields
=menu waveformPOST
=head3 Run-time Parameters
These parameters are used by the run-time code for processing the waveform. They
are not configured using a configuration tool. Only the VAL field is modifiable
at run-time.
VAL references the array where the waveform stores its data. The BPTR field
holds the address of the array.
The NORD field holds a counter of the number of elements that have been read
into the array. It is reset to 0 when the device is rearmed. The BUSY field
indicates if the device is armed but has not yet been digitized.
=fields VAL, BPTR, NORD, BUSY
The following fields are used to operate the waveform in the simulation mode.
See L<Simulation Mode> for more information on the simulation mode fields.
=fields SIOL, SIML, SIMM, SIMS
=begin html
<br>
<hr>
<br>
=end html
=head2 Record Support
=head3 Record Support Routines
=head4 init_record
static long init_record(waveformRecord *prec, int pass)
Using NELM and FTVL space for the array is allocated. The array address is
stored in the record.
This routine initializes SIMM with the value of SIML if SIML type is CONSTANT
link or creates a channel access link if SIML type is PV_LINK. VAL is likewise
initialized if SIOL is CONSTANT or PV_LINK.
This routine next checks to see that device support is available and a device
support read routine is defined. If either does not exist, an error message is
issued and processing is terminated
If device support includes C<init_record()>, it is called.
=head4 process
static long process(waveformRecord *prec)
See L</"Record Processing"> section below.
=head4 cvt_dbaddr
static long cvt_dbaddr(DBADDR *paddr)
This is called by dbNameToAddr. It makes the dbAddr structure refer to the
actual buffer holding the result.
=head4 get_array_info
static long get_array_info(DBADDR *paddr, long *no_elements, long *offset)
Obtains values from the array referenced by VAL.
=head4 put_array_info
static long put_array_info(DBADDR *paddr, long nNew)
Writes values into the array referenced by VAL.
=head4 get_units
static long get_units(DBADDR *paddr, char *units)
Retrieves EGU.
=head4 get_prec
static long get_precision(DBADDR *paddr, long *precision)
Retrieves PREC if field is VAL field. Otherwise, calls C<<< recGblGetPrec() >>>.
=head4 get_graphic_double
static long get_graphic_double(DBADDR *paddr, struct dbr_grDouble *pgd)
Sets the upper display and lower display limits for a field. If the field is VAL
the limits are set to HOPR and LOPR, else if the field has upper and lower
limits defined they will be used, else the upper and lower maximum values for
the field type will be used.
Sets the following values:
upper_disp_limit = HOPR
lower_disp_limit = LOPR
=head4 get_control_double
static long get_control_double(DBADDR *paddr, struct dbr_ctrlDouble *pcd)
Sets the upper control and the lower control limits for a field. If the field is
VAL the limits are set to HOPR and LOPR, else if the field has upper and lower
limits defined they will be used, else the upper and lower maximum values for
the field type will be used.
Sets the following values
upper_ctrl_limit = HOPR
lower_ctrl_limit = LOPR
=head3 Record Processing
Routine process implements the following algorithm:
=over
=item 1.
Check to see that the appropriate device support module exists. If it doesn't,
an error message is issued and processing is terminated with the PACT field
still set to TRUE. This ensures that processes will no longer be called for this
record. Thus error storms will not occur.
=item 2.
Call device support read routine.
=item 3.
If PACT has been changed to TRUE, the device support read routine has started
but has not completed writing the new value. In this case, the processing
routine merely returns, leaving PACT TRUE.
=item 4.
Check to see if monitors should be invoked.
=over
=item *
Alarm monitors are invoked if the alarm status or severity has changed.
=item *
Archive and value change monitors are invoked if APST or MPST are Always or if
the result of the hash calculation is different.
=item *
NSEV and NSTA are reset to 0.
=back
=item 5.
Scan forward link if necessary, set PACT FALSE, and return.
=back
=begin html
<br>
<hr>
<br>
=end html
=head2 Device Support
=head3 Fields Of Interest To Device Support
Each waveform record must have an associated set of device support routines. The
primary responsibility of the device support routines is to obtain a new array
value whenever read_wf is called. The device support routines are primarily
interested in the following fields:
=fields PACT, DPVT, NSEV, NSTA, INP, NELM, FTVL, RARM, BPTR, NORD, BUSY
=head3 Device Support Routines
Device support consists of the following routines:
=head4 long report(int level)
This optional routine is called by the IOC command C<dbior> and is passed the
report level that was requested by the user.
It should print a report on the state of the device support to stdout.
The C<level> parameter may be used to output increasingly more detailed
information at higher levels, or to select different types of information with
different levels.
Level zero should print no more than a small summary.
=head4 long init(int after)
This optional routine is called twice at IOC initialization time.
The first call happens before any of the C<init_record()> calls are made, with
the integer parameter C<after> set to 0.
The second call happens after all of the C<init_record()> calls have been made,
with C<after> set to 1.
=head4 init_record
init_record(precord)
This routine is optional. If provided, it is called by the record support
C<init_record()> routine.
=head4 get_ioint_info
get_ioint_info(int cmd,struct dbCommon *precord,IOSCANPVT *ppvt)
This routine is called by the ioEventScan system each time the record is added
or deleted from an I/O event scan list. cmd has the value (0,1) if the
record is being (added to, deleted from) an I/O event list. It must be
provided for any device type that can use the ioEvent scanner.
=head4 read_wf
read_wf(precord)
This routine must provide a new input value. It returns the following values:
=over
=item *
0: Success.
=item *
Other: Error.
=back
=head3 Device Support For Soft Records
The C<<< Soft Channel >>> device support module is provided to read values from
other records and store them in arrays. If INP is a constant link, then read_wf
does nothing. In this case, the record can be used to hold arrays written via
dbPuts. If INP is a database or channel access link, the new array value is read
from the link. NORD is set.
This module places a value directly in VAL.
If the INP link type is constant, then NORD is set to zero. If the INP link type
is PV_LINK, then dbCaAddInlink is called by C<init_record()>.
read_wf calls recGblGetLinkValue which performs the following steps:
=over
=item *
If the INP link type is CONSTANT recGblGetLinkValue does nothing.
=item *
If the INP link type is DB_LINK, then dbGetLink is called to obtain a new input
value. If dbGetLink returns an error, a LINK_ALARM with a severity of
INVALID_ALARM is raised.
=item *
If the INP link type is CA_LINK, then dbCaGetLink is called to obtain a new
input value. If dbCaGetLink returns an error, a LINK_ALARM with a severity of
INVALID_ALARM is raised.
=item *
NORD is set to the number of values returned and read_wf returns.
=back
=cut
@@ -164,7 +579,7 @@ recordtype(waveform) {
prompt("Sim. Mode Private")
special(SPC_NOMOD)
interest(4)
extra("CALLBACK *simpvt")
extra("epicsCallback *simpvt")
}
field(MPST,DBF_MENU) {
prompt("Post Value Monitors")