<TITLE>Which detector settings should I choose?</TITLE>
<META NAME="description" CONTENT="Which detector settings should I choose?">
<META NAME="keywords" CONTENT="slsDetectors-FAQ">
<META NAME="resource-type" CONTENT="document">
<META NAME="distribution" CONTENT="global">
<META NAME="Generator" CONTENT="LaTeX2HTML v2012">
<META HTTP-EQUIV="Content-Style-Type" CONTENT="text/css">
<LINK REL="STYLESHEET" HREF="slsDetectors-FAQ.css">
<LINK REL="next" HREF="node28.html">
<LINK REL="previous" HREF="node25.html">
<LINK REL="up" HREF="node25.html">
<LINK REL="next" HREF="node27.html">
</HEAD>
<BODY >
<!--Navigation Panel-->
<A NAME="tex2html483"
HREF="node27.html">
<IMG WIDTH="37" HEIGHT="24" ALIGN="BOTTOM" BORDER="0" ALT="next"
SRC="file:/usr/share/latex2html/icons/next.png"></A>
<A NAME="tex2html479"
HREF="node25.html">
<IMG WIDTH="26" HEIGHT="24" ALIGN="BOTTOM" BORDER="0" ALT="up"
SRC="file:/usr/share/latex2html/icons/up.png"></A>
<A NAME="tex2html473"
HREF="node25.html">
<IMG WIDTH="63" HEIGHT="24" ALIGN="BOTTOM" BORDER="0" ALT="previous"
SRC="file:/usr/share/latex2html/icons/prev.png"></A>
<A NAME="tex2html481"
HREF="node1.html">
<IMG WIDTH="65" HEIGHT="24" ALIGN="BOTTOM" BORDER="0" ALT="contents"
SRC="file:/usr/share/latex2html/icons/contents.png"></A>
<BR>
<B> Next:</B> <A NAME="tex2html484"
HREF="node27.html">MYTHEN</A>
<B> Up:</B> <A NAME="tex2html480"
HREF="node25.html">Single photon counting detectors</A>
<B> Previous:</B> <A NAME="tex2html474"
HREF="node25.html">Single photon counting detectors</A>
&nbsp; <B> <A NAME="tex2html482"
HREF="node1.html">Contents</A></B>
<BR>
<BR>
<!--End of Navigation Panel-->
<H1><A NAME="SECTION00410000000000000000">
Which detector settings should I choose?</A>
</H1>
<P>
The choice of the operation settings is very important in order to obtain good quality data.
<BR>
Normally slower settings will reduce the electronics noise and therefore it is possible to work at lower energies, but will saturate for high photon fluxes.
<BR>
On the other hand, faster settings will allow to work with higher photon intensities without pileup, but not to access lower energies because of an higher electronics noise.
<BR>
Therefore it is extremely important to chose adequate settings for the detector depending on the X-ray energy and expected maximum count rate.
In the following is a description of the energy and intensity range coverd by the different settings for each detector.