@ -19,15 +19,64 @@ This document describes the differences between v7.0.1 and v7.0.0
|
|||||||
1 Resolved Issues
|
1 Resolved Issues
|
||||||
=================
|
=================
|
||||||
|
|
||||||
- row and col for multi mod junngfrau single interface (gui)
|
Firmware
|
||||||
- jungfrau multi mod sync mode (start, trigger, stop)
|
--------
|
||||||
- set/get timing jungfrau does not give error when syc enabled
|
|
||||||
- switching between 1 and 2 interfaces did not set gui/client zmq port properly. Resulted in dummy streaming forever.
|
|
||||||
- rx_roi in zmq header for external guis
|
|
||||||
- show fix go in expert mode from any tab (not just settings tab)
|
|
||||||
- if synced, setting master to slave would have changed status to running. workaround found in software
|
|
||||||
- new firmware requirement for fix. if acq stopped in sync mode the slave stays running for next acquisition and framesl is stuck from previous acq.
|
|
||||||
|
|
||||||
|
* [Jungfrau] Stopping acquisition in sync mode
|
||||||
|
Previously, stopping acquisition in sync mode would result in the slave
|
||||||
|
status remaining in Running status for next acquisition and framesl (frames
|
||||||
|
left) would be stuck from the previous acquisition. This is fixed in firmware.
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
Detector Server
|
||||||
|
---------------
|
||||||
|
|
||||||
|
* [Jungfrau] Changing master to slave in sync mode
|
||||||
|
When in sync mode, changing from master to slave would change the status
|
||||||
|
to Running in firmware. A workaround in the detector server fixes this.
|
||||||
|
|
||||||
|
* [Jungfrau] Row and column for multi module Jungfrau
|
||||||
|
This mainly affected only the GUI, unless one was using the row and column
|
||||||
|
sent out by the detector. Row and column values were mixed up, but fixed now.
|
||||||
|
|
||||||
|
* [Jungfrau] Timing in sync mode
|
||||||
|
When sync is enabled, setting or getting timing would give an error. This
|
||||||
|
is fixed now.
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
Client
|
||||||
|
------
|
||||||
|
|
||||||
|
* [Jungfrau] Multi module sync mode
|
||||||
|
For start, stop and trigger acquisition, the procedure to start the slaves
|
||||||
|
(or the master for stop acquisition) first had to be obeyed. This is fixed
|
||||||
|
now.
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
ZMQ
|
||||||
|
---
|
||||||
|
|
||||||
|
* [Jungfrau][Gotthard2] Client ZMQ port when using 2 interfaces
|
||||||
|
When switching between 1 and 2 interfaces, the client or gui zmq port
|
||||||
|
was not set properly and resulted in dummy streaming forever. This is
|
||||||
|
fixed now.
|
||||||
|
|
||||||
|
* Rx_roi
|
||||||
|
This parameter is now also streamed in the zmq header to be able to use in
|
||||||
|
external GUIs.
|
||||||
|
|
||||||
|
|
||||||
|
GUI
|
||||||
|
---
|
||||||
|
|
||||||
|
* [Jungfrau] Show Fix_G0 in expert mode
|
||||||
|
Fix_G0 was only shown when expert mode was enabled from Settings Tab. Now,
|
||||||
|
fixed to show when expert mode enabled from any tab.
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
2 On-board Detector Server Compatibility
|
2 On-board Detector Server Compatibility
|
||||||
@ -63,8 +112,8 @@ This document describes the differences between v7.0.1 and v7.0.0
|
|||||||
|
|
||||||
Eiger 20.02.2023 (v31)
|
Eiger 20.02.2023 (v31)
|
||||||
|
|
||||||
Jungfrau 04.11.2022 (v1.4, HW v1.0)
|
Jungfrau 16.05.2023 (v1.4.1, HW v1.0)
|
||||||
03.11.2022 (v2.4, HW v2.0)
|
15.05.2023 (v2.4.1, HW v2.0)
|
||||||
|
|
||||||
Mythen3 24.01.2023 (v1.4)
|
Mythen3 24.01.2023 (v1.4)
|
||||||
|
|
||||||
|
Loading…